Abstract
Physiological parameters are altered in rheumatoid arthritis (RA). We evaluated whether changes in physiological metrics, collected from wearable devices, identify and precede the development of both symptomatic and inflammatory RA flares. Participants with RA answered daily disease activity surveys and provided laboratory assessments of inflammatory activity. They wore an Apple Watch (n = 35), Fitbit (n = 17), or Oura Ring (n = 3) collecting heart rate (HR), resting heart rate (RHR), heart rate variability (HRV), and steps. Linear mixed effect models were used to associate HR, RHR and steps with flare and remission periods. Cosinor mixed effect models assessed circadian features of HRV. Mixed effect logistic regression models evaluated changes in physiological metrics prior to the onset of flares. The study enrolled 53 participants (88.7% female) with a mean age of 51.1 (SD 15.2) years. Each contributed a mean of 105 (SD 97) days of data. Mean steps were lower, while mean nighttime HR was higher during symptomatic periods, compared to periods of symptomatic remission. Means daily HR, daytime HR, nighttime HR, and RHR were higher during periods of inflammatory flares, compared to inflammatory remission. Circadian features of HRV differentiated inflammatory and symptomatic flares from remission. All metrics were altered up to 4 weeks prior to inflammatory and symptomatic flare development. This suggests the potential use of wearable devices for disease monitoring and flare prediction.
Supplementary Information
The online version contains supplementary material available at 10.1038/s41598-025-29748-y.
Keywords: Wearable device, Rheumatoid arthritis, Inflammation, Prediction
Subject terms: Biomarkers, Rheumatology
Introduction
Rheumatoid arthritis (RA) is a chronic immune mediated inflammatory disease characterized by inflammation of the joints and symptoms such as joint pain, swelling, stiffness and reduced mobility1. Its management is challenging due to the unpredictable nature of disease flares. Furthermore, there can be discordance between inflammation and symptoms, and between physician assessed and patient reported RA activity2. Monitoring modalities are currently limited to single time point infrequent clinical visits, laboratory testing and clinician-dependent or patient reported assessments3,4.
Wearable devices are widely adopted by the general population and provide a novel means to passively and continuously assess physiological parameters outside the clinical setting. Through remote patient monitoring, these devices are increasingly utilized in the management of chronic conditions such as diabetes and heart failure, where their use has been associated with improved disease outcomes5,6. There is growing interest in the use of wearable devices to monitor inflammatory diseases7. However, in RA few studies have examined their utility for tracking disease activity, with most focusing on physical activity metrics. One study of 155 participants with either RA or axial spondyloarthritis demonstrated that patient reported flares were associated with reduced physical activity as measured by activity trackers, and that changes in physical activity patterns associated with flare episodes8. Another study of 85 participants with RA who wore an activity tracker for 7 days found that those with moderate to high symptomatic disease activity had lower total daily exercise and step counts9. Furthermore, it has been shown that digital health measures can augment patient reported outcomes. In a study of 30 participants with moderate-to-severe RA compared to 30 healthy controls a machine learning framework incorporating symptoms derived from an iPhone guided test, actigraphy and heart sensor data successfully distinguished RA status and disease severity10.
Chronic inflammatory diseases like RA are characterized by alterations in autonomic nervous system function. Heart rate variability (HRV), a measure of the variation in time between heartbeats, serves as an indirect indicator of autonomic balance, with lower HRV generally reflecting increased sympathetic tone11. Individuals with active RA have been shown to exhibit lower HRV compared to those with inactive disease12. Similarly, higher heart rate (HR) and resting heart rate (RHR) values have been reported in RA relative to healthy controls, reflecting this autonomic dysfunction13,14. However, prior studies largely relied on single timepoint or short-term assessments of physiological markers rather than continuous longitudinal monitoring. Wearable devices now enable near-continuous measurement of physiological parameters such as HR, RHR, HRV, and physical activity, offering the potential to capture dynamic changes that correspond to underlying RA inflammatory status. The aim of our present study is to evaluate whether longitudinally collected physiological metrics from wearable devices can identify both inflammatory and symptomatic RA activity. In addition, we examined whether these metrics change prior to the onset of inflammatory and symptomatic RA flares, exploring their potential utility for early flare detection and disease monitoring.
Results
A total of 53 participants enrolled in the study and contributed wearable and either laboratory or survey data across 6 U.S. states (Table 1). Of these, 50 participants had at least one day of overlapping wearable and flare data (symptomatic or inflammatory). The mean age was 51.09 (SD 15.22) years and 47 (88.7%) participants were female. The mean disease duration was 9.50 (SD 7.02) years.
Table 1.
Demographic information for study participants.
| Overall Cohort (N = 53) | |
|---|---|
| Age, mean (SD) | 51.1 (15.2) |
| Sex, female (%) | 47 (88.7) |
| BMI, mean (SD) | 29.0 (7.8) |
| Race | |
| Asian | 2 (3.8%) |
| Black | 12 (22.6%) |
| White | 31 (58.5%) |
| Missing Variable | 8 (15.1%) |
| Ethnicity | |
| Hispanic | 15 (28.3%) |
| Not Hispanic | 36 (67.9%) |
| Missing Variable | 2 (3.8%) |
| Smoking Status | |
| Current | 1 (1.9%) |
| Never | 36 (67.9%) |
| Past Smoker | 16 (30.2%) |
| Reported Medical Conditions | |
| Asthma | 11 (20.8%) |
| Hypertension | 6 (11.3%) |
| Fibromyalgia | 2 (3.8%) |
| Cancer | 2 (3.8%) |
| Diabetes | 2 (3.8%) |
| Thyroid Disease | 2 (3.8%) |
| Autoimmune hepatitis | 1 (1.9%) |
| Lupus | 1 (1.9%) |
| Sjogren’s Disease | 1 (1.9%) |
| Multiple Sclerosis | 1 (1.9%) |
| Sarcoidosis | 1 (1.9%) |
| RA Medications Use at Enrollment | |
| Corticosteroids | 5 (9.4%) |
| Biologic Agents | 20 (37.7%) |
| Small Molecules | 4 (7.5%) |
| Immunomodulators | 41 (77.4%) |
| NSAIDs | 10 (18.9%) |
Thirty-five participants used an Apple Watch, 17 used a Fitbit and 3 used an Oura Ring, with one participant using both a Fitbit and Apple Watch, and another using both an Apple Watch and Oura Ring. Participants contributed a mean of 154 (SD 93) days of wearable data and wore their devices an average of 16.4 (SD 4.6) hours per day. Mean device adherence was 66.8% (SD 34.8) for the Apple Watch, 53.3% (SD 28.3) for the Fitbit, and 72.8% (SD 22.5) for the Oura Ring, resulting in a total of 8,183 days (142,985 h) of wearable data across all participants. Supplementary Table 1 summarizes study duration, device compliance, survey and CRP laboratory records, flare prevalence and the missingness of data. A representative participant’s longitudinal wearable, survey, and laboratory data are shown in Fig. 1. There was no significant difference in the proportion of missing wearable data between flare and remission periods for either symptomatic or inflammatory flare categories (p = 0.49 and p = 0.23, respectively), supporting the assumption that missingness was random and not related to disease activity.
Fig. 1.
An exemplary participant’s daily trajectories are shown over the entire study duration including physiological metrics (RHR, HR, HRV RMSSD and Steps), CRP lab values and RAPID-3 daily survey scores. Detected inflammatory and symptomatic flares are shown with shaded bands in the bottom two panels. Note, an isolated RAPID-3 survey > 3 is not taken as a flare, rather, at least 3 positive out of 4 surveys in a 7-day window is classified as a symptomatic flare. CRP lab values are augmented to ± 7 days for inflammatory flare detection.
Wearable data overlapping with inflammatory flare assessments were available in 38 participants and with symptom flare assessments in 47 individuals. Fourteen of 38 participants reported elevated CRP levels (inflammatory flares), and 36 out of 47 participants had symptomatic flares. Participants contributed a mean of 105 (SD 97) days with overlapping wearable and flare data.
Identification of inflammatory flares
An overview of inflammatory flare trajectories is shown in Supplementary Fig. 1. There were 270 days of inflammatory flares and 754 days of inflammatory remission over the follow up period. Physiological metrics collected from wearable devices differentiated inflammatory from non-inflammatory periods. The mean daily, mean daytime, and mean nighttime HR were all higher during inflammatory flares (mean HR 81.42 ± 3.03, day HR 84.26 ± 3.10, night HR 78.63 ± 3.43) compared to periods of inflammatory remission (mean HR 75.44 ± 2.86, p < 0.001; day HR 77.81 ± 2.93, p < 0.001; night HR 73.16 ± 3.26, p < 0.004). Similarly, RHR was higher during inflammatory flares (63.21 ± 2.22) than during periods of inflammatory remission (58.24 ± 2.15; p < 0.0001). Mean daily steps did not differ significantly between periods of inflammatory flare (7,737 ± 1,296 steps) and inflammatory remission (8,730 ± 1,265 steps, p = 0.09) (Fig. 2a). Supplementary Table 2 shows detailed flare-remission contrasts, standard error (SE) and p-values for each physiological metric and flare type.
Fig. 2.
The relationship between physiological metrics measured by wearable devices and inflammatory flares. (A) The marginal means and 95% confidence intervals for resting heart rate, daily heart rate, daytime heart rate, nighttime heart rate, and steps comparing periods of inflammatory flare to inflammatory remission as well as symptomatic flare to symptomatic remission. The x-axis represents the difference between each flare and remission state, in either beats per minute or steps. (B) Circadian parameters of heart rate variability comparing periods of inflammatory flare with inflammatory remission. Stars indicate significant differences, with (+: p < 0.1; *: p < 0.05; **: p < 0.01; ***: p < 0.001, ****: p < 0.0001).
Significant differences in HRV were observed between inflammatory flare and inflammatory remission periods. The circadian pattern of HRV can be described using the following parameters (1) MESOR: a rhythm-adjusted mean of the circadian pattern; (2) Amplitude: difference between the peak and the mean value giving a measure of half the extent of variation within a day; and (3) Acrophase and peak time: measures of the time when peak values occur each day. The MESOR of the circadian pattern of the HRV metric root mean square of successive differences between normal heartbeats (RMSSD) was significantly lower during inflammatory activity (21.47ms 95% CI 13.28–32.74) compared to remission (28.72ms 95% CI 18.17–43.83; p < 0.001). The amplitude is significantly lower during periods of inflammatory activity (1.05ms 95% CI 0.19–4.12) compared to periods of inflammatory remission (3.66ms 95% CI 1.70–7.54, p = 0.04). Acrophase and peak time did not differ significantly (p = 0.98). Similarly, there were differences in the HRV metric the standard deviation of the interbeat intervals of normal sinus beats (SDNN) based on the presence or absence of underlying inflammation. There were significant differences in the amplitude of the circadian pattern of SDNN between periods of inflammation (4.46ms 95% CI 2.25–7.98) and inflammatory remission (1.73 95% CI 0.82–3.21, p = 0.006), but not in the MESOR (p = 0.39) and acrophase or peak time (p = 0.35) (Fig. 2b). Cosinor mixed-effect model flare-remission contrasts for MESOR, amplitude, acrophase and peak time, along with p-values are shown in Supplementary Tables 3 and 4 for both RMSSD and SDNN HRV metrics, respectively.
Identification of symptomatic flares
An overview of symptomatic flare trajectories is presented in Supplementary Fig. 2. Across the cohort, there were 1,985 days of symptomatic flare and 3,353 days of symptomatic remission. Physiologic metrics again distinguished between symptomatic flare and symptomatic remission periods. Mean daily and nighttime HR were higher during symptomatic flares (mean HR 81.03 ± 2.30, night HR 76.91 ± 2.33) compared to periods of symptomatic remission (mean HR 79.77 ± 2.28, p = 0.04; night HR 74.01 ± 2.30, p < 0.0001), whereas daytime HR and RHR did not differ significantly (day HR 81.22 ± 2.32 vs. 80.72 ± 2.31, p = 0.44; 61.50 ± 1.88 vs. 61.62 ± 1.88, p = 0.66). During periods of symptomatic activity participants walked significantly less steps compared to periods of symptomatic remission (7,282 ± 954 steps vs. 7,797 ± 954 steps, p = 0.004) (Fig. 2a) (Supplementary Table 2).
Circadian HRV patterns also differed between symptomatic flare and symptomatic remission periods. There were significant differences in the circadian pattern of RMSSD during symptomatic flares (MESOR 28.82ms 95% CI 21.36–38.60; acrophase − 1.68 95% CI −1.93- −1.42; peak time 6.41 h 95% CI 5.41–7.37) compared to remission (MESOR 31.06ms 95% CI 23.12–41.38, p < 0.001; acrophase − 2.16 95% CI −2.28- −2.03, p = 0.002; peak time 8.25 h 95%CI 7.77–8.71, p = 0.002). Similar findings were observed for SDNN. The amplitude, acrophase and peak time were significantly different during symptomatic flares (2.47ms 95% CI 1.72–3.44; −1.85 95% CI −2.02- −1.67; 7.05 h 95% CI 6.37–7.71) compared to symptomatic remission periods (3.02 95% CI 2.31–3.91, p = 0.042; −1.26 95% CI −1.35- −1.17, p < 0.001; 4.81 95% CI 4.48–5.17, p < 0.001) (Fig. 3) (Supplementary Tables 3 and 4).
Fig. 3.
Comparison of circadian parameters of heart rate variability between periods of symptomatic flare with symptomatic remission. Stars indicate significant differences, with (+: p < 0.1; *: p < 0.05; **: p < 0.01; ***: p < 0.001, ****: p < 0.0001).
Changes preceding inflammatory and symptomatic flares
Changes in the physiological metrics RHR, daily HR, daytime HR, nighttime HR, steps and HRV (RMSSD) were evaluated on the day of the flare and at 7, 14, 21, and 28 days prior to both inflammatory and symptomatic flare onset. Because of class imbalance, model performance was primarily assessed using the F1 score, which balances precision and recall. When all physiological metrics were included, predictive performance remained high throughout the 28-days preceding inflammatory flares (28 days before flare; AUC 1.00 [0.99–1.00]; F1 0.95; AUPRC 0.98; Sensitivity 0.97; Specificity 0.97) (Fig. 4a). Similar results were observed for symptomatic flares (28 days before flare; AUC 0.99 [0.99–1.00]; F1 0.93; AUPRC 0.97; Sensitivity 0.96; Specificity 0.97). High F1 scores were also maintained when evaluating individual physiological metrics across the 28-day pre-flare period (Fig. 4b). These findings demonstrate that physiological alterations preceded both symptomatic and inflammatory flare onset by up to four weeks, supporting the potential of wearable derived signals for early flare prediction and proactive clinical management. Complete model performance metrics are provided in Supplementary Tables 5 and 6.
Fig. 4.
Change in physiological metrics preceding flare. (A) The association between models that include all physiological metrics, taken 7, 14, 21, and 28 days prior to the development of inflammatory and symptomatic flares, with the development of those respective flares. F1 scores summarize the performance of a model including all reported physiological metrics at each time point preceding flare development. (B) The F1 score at 7, 14, 21, and 28 days prior to inflammatory and symptomatic flare for each physiological metric measured by wearable devices.
Discussion
The RA Forecast study demonstrates the feasibility of leveraging commercially available wearable devices to identify and potentially predict both symptomatic and inflammatory RA flares. To our knowledge, this is the first study to show that multiple physiological metrics collected from wearables can differentiate these two flare types and that measurable physiological changes occur several weeks before flare onset.
There are currently limited modalities available to monitor RA and no means to predict future flares. Traditional approaches rely on cross-sectional clinical or laboratory assessments, which are infrequent, reactive, and often performed after symptoms have already developed. In contrast, wearable technologies enable passive, continuous monitoring of physiological signals in real-world settings, offering an opportunity to capture early biological changes that precede clinical worsening.
Prior studies using wearable sensors in RA have largely focused on actigraphy and physical activity, showing that symptomatic flares are associated with reduced movement8–10. While symptom tracking provides valuable insight into patient experience, it may not fully capture subclinical inflammation, which drives long-term joint damage. Although physical activity monitoring holds promise, its accuracy can be compromised by device non-compliance. Moreover the known discordance between symptoms and inflammation in RA15 underscores the need for monitoring approaches that capture both states. Active RA is characterized by autonomic nervous system dysfunction, reflected by elevated HR and RHR and reduced HRV, indicating diminished parasympathetic nervous system activity16. These physiological signals can be captured by wearable devices, offering a means to monitor RA activity through objective, biologically grounded measures. Our group has previously demonstrated that changes in these parameters can detect and predict disease activity in infectious and chronic inflammatory conditions, including COVID-19 and inflammatory bowel disease17–21.
In this study, longitudinally collected wearable data distinguished both symptomatic and inflammatory flares. Consistent with prior findings, step counts declined during symptomatic flares, accompanied by significant alterations in mean daily and nightly HR and HRV patterns. Symptomatic activity in RA may, reflect non-inflammatory mechanisms such as osteoarthritis or sensory nerve–mediated pain. The observed associations between wearable-derived physiological metrics and patient-reported symptoms suggest a promising avenue for objectively quantifying symptom burden and linking subjective experiences to underlying physiological changes. When distinguishing inflammatory flares from remission, all physiological metrics differed significantly except step count, either reflecting the lack of concurrent symptoms or localization of inflammation to joints less affecting mobility.
Importantly, physiological metrics began to change up to four weeks before symptomatic or inflammatory flare onset, suggesting that wearable-derived data can detect early, subclinical alterations in autonomic and inflammatory activity. These results highlight the potential of wearables for early flare prediction and proactive disease management. Future studies applying advanced machine learning and deep learning methods will be essential to translate these population-level findings into individualized predictive models for clinical use.
Although wearables offer promise for real-world monitoring, several practical and implementation challenges remain. Adherence to device use may vary with comfort, engagement, and digital literacy. Additionally, further research is needed to identify which patients are most likely to benefit and when in the disease course monitoring should be initiated. Integrating continuous physiological data into care pathways also requires robust infrastructure for data ingestion, storage, analysis, and visualization, while maintaining privacy and security standards. It remains unclear how best to incorporate this data into clinical decision-making, whether results should be shared with clinicians, patients, or both, and how often data should be reviewed. Furthermore, an understanding of how to respond to physiologic signals in a clinically meaningful way without contributing to alarm fatigue or unnecessary anxiety is needed. Finally, translating wearable-derived trends into actionable insights will require well-calibrated predictive models and thoughtfully designed interfaces to ensure usability and trust.
This study has several limitations. Inflammatory assessments were obtained as part of routine care rather than on a standardized schedule, limiting temporal precision around flare onset and resolution. We imputed laboratory values within ± 7 days of each CRP measurement to better approximate inflammatory periods, though this approach may not fully capture true flare dynamics. More frequent, protocolized biomarker collection in future studies will help validate these findings. Physiological metrics such as HRV can also be influenced by factors beyond inflammation. While we adjusted for common covariates (age, sex, BMI), unmeasured confounders may remain.
Additionally, there are no standardized criteria for defining symptomatic RA flares using daily symptom data. To reduce misclassification, we required symptoms to demonstrate chronicity and performed a sensitivity analysis, though residual error is possible. A further limitation is the inability to analyze the intersection of inflammatory and symptomatic activity. Only 6 participants experienced both symptomatic and inflammatory flares with overlapping wearable data, while 3 had inflammatory flares during symptomatic remission, none had symptomatic flares during inflammatory remission, and 14 participants had concurrent remission of both. Given the discordance between patient-reported symptoms and objective inflammatory activity in RA, future studies with larger cohorts will be needed to evaluate how different combinations of symptomatic and inflammatory states influence physiological signals. This represents a key area where wearable technologies may enhance disease characterization by providing objective, continuous data that bridge patient-reported and biologic measures.
Medication use represents an additional confounder, as participants were on varied therapies with heterogeneous dosing schedules and timing of adjustments. Because laboratory and symptom assessments were not always synchronized with medication changes, we could not fully disentangle treatment effects from intrinsic disease activity. Future studies with standardized treatment documentation will help clarify these relationships.
Additionally, although sleep data were collected from the wearable devices, they were not included in the current analysis. Given the complexity and potential relevance of sleep metrics to RA flares, a dedicated future analysis will evaluate how changes in sleep patterns relate to symptomatic and inflammatory activity, including how sleep trajectories change in the weeks preceding and following flare events. A further limitation is that three different device types were used in the study, each with distinct wear positions, sampling frequencies, and proprietary data processing algorithms. We accounted for device-related differences by including device type as a covariate and using random intercepts to model within-subject variability. As each participant contributed data from a single device, this approach adjusts for between-device variability while maintaining the longitudinal integrity of the data. Our analyses focused on within-person changes over time rather than between-subject comparisons. Nonetheless, residual confounding due to device-specific characteristics cannot be excluded, particularly given the modest sample size. Larger, standardized studies comparing data across platforms will be valuable for assessing device comparability and harmonizing physiological metrics. We also did not collect participant-reported data on wearable usability, comfort, or preferences, which limits our ability to directly assess patient experience. However, device adherence, quantified as the percentage of days with valid wearable data, serves as an objective measure of engagement. Future studies should incorporate qualitative and quantitative assessments of user experience across device types (e.g., wrist-worn versus ring-based) to better understand barriers to sustained use and optimize long-term compliance. Lastly, our dataset was imbalanced, with remission periods outnumbering flare periods. To address this, we employed mixed-effects logistic regression models appropriate for repeated measures, and we used the F1 score—rather than AUC—as a more suitable metric for performance evaluation in imbalanced datasets. No automated feature selection was applied, as our goal was to evaluate the collective behavior of all physiologically relevant variables. Advanced feature selection and machine learning models are currently under development and will be reported separately.
Conclusions
This study is the first to demonstrate that multiple physiological metrics derived from wearable devices can distinguish both inflammatory and symptomatic disease activity in RA and exhibit measurable changes weeks before flare onset. These findings highlight the potential of wearable technology to support remote, continuous disease monitoring, enable early flare prediction, and facilitate more personalized management of RA.
Methods
Study population and procedures
The RA Forecast Study is a prospective cohort study that enrolled individuals with RA from throughout the United States between February 2023 and February 2024. Participants were recruited through study flyers and email advertisements sent to individuals with RA who visited a rheumatology clinic in the Mount Sinai Health System. Inclusion criteria included (1) a diagnosis with RA, (2) age ≥ 18 years, (3) use of a medication to treat RA, and (4) the willingness to use a wearable device. Exclusion criteria included pregnancy, other chronic medical conditions, a pacemaker or defibrillator, or the use of medications that impact HR or HRV (i.e. beta blockers, benzodiazepines). Participants could use their own Apple Watch, Fitbit, or Oura Ring. For those without a device, an Apple Watch or Fitbit was provided for the duration of participation. No financial compensation was offered.
Participants downloaded ehive22, our custom mobile application, to their smartphones. Within ehive, they verified inclusion criteria, signed electronic consent and linked their wearable device. Baseline demographic and medical history data were collected, and participants completed daily patient reported outcome surveys in ehive. Participants uploaded any C-reactive protein (CRP) laboratory results collected as part of their usual clinical care. Participants were free to provide as much or as little data as they would like, with smart phone push notifications sent to those who contributed wearable or survey data fewer than four days per week. It was recommended that wearable devices be used for a minimum of 8 h per day and at least 4 days per week. Custom smart phone push notifications and emails were used as light touch engagement measures to maintain compliance.
Wearable devices
The study utilized the Apple Watch, Fitbit, and Oura Ring, three commercially available wearable devices. The Apple Watch and Fitibit are wrist worn devices, while the Oura Ring is worn on the finger. Heart rate (HR), resting heart rate (RHR), HRV, and steps were collected from the devices, with all three containing photoplethysmography optical sensors that assess capillary volume changes. These enable the sensing of heart beats and the time difference between each heartbeat, or the interbeat intervals (IBI), for the calculation of HRV23,24. Each device also includes an actigraphy sensor for step count detection. HR is reported as beats per minute (BPM) and RHR is defined as an estimation of the lowest HR during rest periods.
All devices provide HRV metrics. The Apple Watch calculates SDNN, reflecting both sympathetic and parasympathetic nervous system activity. The Fitbit and Oura Ring reports HRV as RMSSD, a time domain metric more strongly influenced by parasympathetic tone, with lower values reflecting increased sympathetic activity25. For Apple Watch users, IBI data were collected to enable RMSSD calculation, allowing integration with Fitbit and Oura Ring HRV datasets.
Physiological data from all devices are pre-processed by the manufacturers using proprietary algorithms that minimize motion artifacts and signal noise. The Apple Watch reports HR at variable sampling intervals, with frequencies reaching up to one reading per second in our cohort. HRV (RMSSD) is derived from IBI segments of approximately one-minute duration, with an average of six HRV readings per participant per day. In comparison, in our cohort, the Fitbit and Oura Ring provided HR data at fixed intervals of one minute and five minutes, respectively, and measured HRV every five minutes during sleep periods. To support analysis across varying time scales, these features were aggregated to generate hourly, daytime, nighttime, and full 24-hour daily summary metrics.
Laboratory and clinical assessments
RA flares were defined as (1) inflammatory flares, denoting the presence of underlying inflammation, and (2) symptomatic flares, characterized by the presence of symptoms. Laboratory measures of inflammation were collected as part of each participant’s standard of care management throughout the study period. An inflammatory flare was defined as a CRP value > 5 mg/dL. Because inflammatory and non-inflammatory states extend beyond the single time point of a laboratory measurement, CRP values were imputed across a +/- 7-day window surrounding each blood draw to reduce misclassification of inflammatory status around the test date20.
Symptomatic activity was assessed using the Routine Assessment of Patient Index Data (RAPID-3) scale, a validated patient reported outcome derived from the Multi-dimensional HAQ (MD-HAQ)4. The RAPID-3 includes domains assessing physical function, pain, and global health. It has been validated and shown to correlate with DAS28 and CDAI scores in RA26,27. It is scored from 0 to 30, with a score > 3 consistent with active RA of mild, moderate or high disease severity; score ≤ 3 is classified as remission4. Because daily symptom reporting varies in frequency, there is no consensus for defining symptomatic flares from daily data. To evaluate several criteria, we performed a sensitivity analysis for several definitions of symptomatic flare in our study (Supplementary Fig. 3). Based on this analysis, we defined symptomatic flares as having at least 4 RAPID-3 surveys answered in a 7-day period, with at least 3 of these surveys meeting criteria (RAPID-3 > 3) for symptomatic activity. Each 7-day period was analyzed as a rolling window that includes daily survey data that extends 3 days before and 3 days after each day being analyzed.
Statistical analysis
Linear mixed-effect (LME) models were used to quantify differences in physiological metrics between flare and remission periods. All models included fixed effects for the covariates of age, sex, device type and body mass index (BMI) and a random intercept for each participant. This accounts for within-subject correlations, along with the population-level influence of age, sex, BMI and signal-quality differences across devices. Missing values for age (n = 5) and sex (n = 1) were imputed using multivariate imputation that leveraged all available demographic and device data. Flare and remission states were incorporated as predictors in each model. The models were fitted on a complete-case dataset that analyzed only days for which physiological variables were present, with days with missing values excluded. Physiological metrics were fitted using the “lme” function from the “nlme” R package, and marginal means with 95% confidence intervals (CI) were estimated using the emmeanspackage28,29. HR metrics were analyzed as a mean value over three time periods: (1) daily: assessed over the entire 24 h period, (2) daytime: including data from 8:00am-10:00pm, (3) nighttime: including data from 10:00pm-8:00am. Our linear mixed-effects models yield reliable estimates under the assumption that missing wearable data are missing at random (MAR), an assumption considered appropriate in this context. See the Supplemental Methods Section for further details.
HRV exhibits a distinct 24-hour circadian rhythm, which is not adequately captured by traditional summary measures such as averages or ranges30. Moreover, wearable devices record HRV data at irregular intervals, necessitating analytic approaches that account for non-uniform sampling and underlying rhythmicity. COSINOR methods are a well-established method for characterizing circadian patterns and has been applied to HRV analysis31,32. This approach describes the rhythm using the circadian parameters (1) MESOR (M): the rhythm-adjusted mean; (2) Amplitude (A): the difference between the peak and the mean value giving a measure of half the extent of daily variation; and (3) Acrophase: the timing of the daily peak value. Acrophase is related to peak time of the circadian curve. Our team has extended this approach within a mixed-effects modeling framework to evaluate day-to-day changes in HRV circadian patterns. This analysis was conducted using the CosinorRmixedeffects R package33, which models 24-hour HRV circadian rhythm while robustly handling missing hourly HRV data. Goodness-of-fit was further supported using residual plots, which are presented in Supplementary Fig. 4 and Supplementary Fig. 5, for both inflammatory and symptomatic flare models. See the Supplemental Methods Section for further details.
To assess temporal associations between individual and combined physiological metrics and flare onset, we used mixed-effects logistic regression (LR) models to determine the probability of having an inflammatory or symptomatic flare. Predictions were derived on the same day, 7, 14, 21, and 28 days prior to flares. A complete-case analysis was performed by using only days when all features are available. Model performance was estimated using the area under the curve (AUC), area under the precision-recall curve (AUPRC), threshold, sensitivity, specificity, F1, precision, recall, and accuracy. Models were implemented using the “glmer” function from the “lme4” R package34. This approach incorporated fixed effects for age, sex, BMI, and device type, as well as a random intercept for each participant to account for within-subject correlation across repeated measures. The physiological metrics included RHR, daily HR, daytime HR, nighttime HR, step count, and HRV (RMSSD).
Study approval
This study was approved by the Mount Sinai Institutional Review Board. Written informed consent was obtained from all participants prior to participation. All research was carried out in accordance with relevant guidelines and regulations. Research was performed in accordance with the Declaration of Helsinki.
Supplementary Information
Below is the link to the electronic supplementary material.
Author contributions
PS, MD, JKW, KL, DH, BES, MSF, PG, RPH made substantial contributions to the conception or design of the work, or the acquisition, analysis or interpretation of the data for the work; made contributions to the drafting of the work or revising it critically for important intellectual content; provided final approval of the version to be published and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are addressed.
Funding
Support for this study was provided by K23DK129835 (Robert P Hirten).
Data availability
The datasets analyzed during the current study is available from the corresponding author on reasonable request.
Declarations
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Grassi, W., De Angelis, R., Lamanna, G. & Cervini, C. The clinical features of rheumatoid arthritis. Eur J. Radiol May. 27 (Suppl 1), S18–24. 10.1016/s0720-048x(98)00038-2 (1998). [DOI] [PubMed] [Google Scholar]
- 2.Khan, N. A. et al. Determinants of discordance in patients’ and physicians’ rating of rheumatoid arthritis disease activity. Arthritis Care Res. (Hoboken) Feb. 64 (2), 206–214. 10.1002/acr.20685 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Banderas, B., Skup, M., Shields, A. L., Mazar, I. & Ganguli, A. Development of the rheumatoid arthritis symptom questionnaire (RASQ): a patient reported outcome scale for measuring symptoms of rheumatoid arthritis. Curr Med. Res. Opin Sep.33 (9), 1643–1651. 10.1080/03007995.2017.1338562 (2017). [DOI] [PubMed] [Google Scholar]
- 4.Pincus, T., Yazici, Y. & Bergman, M. J. Nov. RAPID3, an index to assess and monitor patients with rheumatoid arthritis, without formal joint counts: similar results to DAS28 and CDAI in clinical trials and clinical care. Rheum Dis Clin North Am. 35 (4), 773-8, viii. 10.1016/j.rdc.2009.10.008 (2009). [DOI] [PubMed]
- 5.Teo, E., Hassan, N., Tam, W. & Koh, S. Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis. Diabetologia Apr. 65 (4), 604–619. 10.1007/s00125-021-05648-4 (2022). [DOI] [PubMed] [Google Scholar]
- 6.Ehringer, D. S., Mughmaw, T. E. & Albers, R. C. Use of remote patient monitoring kits to reduce hospitalization and mortality rates for patients with heart failure. Am J. Health Syst. Pharm Nov. 2010.1093/ajhp/zxad292 (2023). [DOI] [PubMed]
- 7.Hirten, R. P. et al. Wearable devices are well accepted by patients in the study and management of inflammatory bowel disease: A survey study. Dig Dis. Sci Jul. 10.1007/s10620-020-06493-y (2020). [DOI] [PubMed] [Google Scholar]
- 8.Gossec, L. et al. Detection of flares by decrease in physical activity, collected using wearable activity trackers in rheumatoid arthritis or axial spondyloarthritis: an application of machine learning analyses in rheumatology. Arthritis Care Res. (Hoboken) Oct.71 (10), 1336–1343. 10.1002/acr.23768 (2019). [DOI] [PubMed] [Google Scholar]
- 9.Tada, M., Yamada, Y., Mandai, K., Matsumoto, Y. & Hidaka, N. Daily physical activity measured by a wearable activity monitoring device in patients with rheumatoid arthritis. Clin Rheumatol Jul. 41 (7), 2011–2019. 10.1007/s10067-022-06147-6 (2022). [DOI] [PubMed] [Google Scholar]
- 10.Creagh, A. P. et al. Digital health technologies and machine learning augment patient reported outcomes to remotely characterise rheumatoid arthritis. NPJ Digit. Med Feb. 12 (1), 33. 10.1038/s41746-024-01013-y (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Berntson, G. G. et al. Heart rate variability: origins, methods, and interpretive caveats. Psychophysiology Nov. 34 (6), 623–648. 10.1111/j.1469-8986.1997.tb02140.x (1997). [DOI] [PubMed] [Google Scholar]
- 12.Saramet, E. E. et al. Autonomic dysfunction and cardiovascular risk in patients with rheumatoid arthritis: can heart rate variability analysis contribute to a better evaluation of the cardiovascular profile of a patient? J Clin. Med Dec.17 (24). 10.3390/jcm12247736 (2023). [DOI] [PMC free article] [PubMed]
- 13.Piha, S. J. & Voipio-Pulkki, L. M. Elevated resting heart rate in rheumatoid arthritis: possible role of physical deconditioning. Br J. Rheumatol Mar.32 (3), 212–215. 10.1093/rheumatology/32.3.212 (1993). [DOI] [PubMed] [Google Scholar]
- 14.Adlan, A. M. et al. Cardiovascular autonomic regulation, inflammation and pain in rheumatoid arthritis. Auton Neurosci Dec.208, 137–145. 10.1016/j.autneu.2017.09.003 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Bai, Z. et al. Synovial fibroblast gene expression is associated with sensory nerve growth and pain in rheumatoid arthritis. Sci Transl Med Apr. 10 (742), eadk3506. 10.1126/scitranslmed.adk3506 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Ingegnoli, F. et al. The link between autonomic nervous system and rheumatoid arthritis: from bench to bedside. Front. Med. (Lausanne). 7, 589079. 10.3389/fmed.2020.589079 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Hirten, R. P. et al. Longitudinal autonomic nervous system measures correlate with stress and ulcerative colitis disease activity and predict flare. Inflamm. Bowel Dis.10 18 (10), 1576–1584. 10.1093/ibd/izaa323 (2021). [DOI] [PubMed] [Google Scholar]
- 18.Hirten, R. P. et al. Use of physiological data from a wearable device to identify SARS-CoV-2 infection and symptoms and predict COVID-19 diagnosis: observational study. J. Med. Internet Res.02 (2), e26107. 10.2196/26107 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Hirten, R. P. et al. Evaluation of a machine learning approach utilizing wearable data for prediction of SARS-CoV-2 infection in healthcare workers. JAMIA Open Jul. 5 (2), ooac041. 10.1093/jamiaopen/ooac041 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Hirten, R. P. et al. Physiological data collected from wearable devices identify and predict inflammatory bowel disease flares. Gastroenterology Jan. 0910.1053/j.gastro.2024.12.024 (2025). [DOI] [PMC free article] [PubMed]
- 21.Hirten, R. P. et al. Wearable devices identify altered sleep characteristics and sleep trajectories in active inflammatory bowel disease. Clin Gastroenterol. Hepatol Jun. 2610.1016/j.cgh.2025.06.003 (2025). [DOI] [PubMed]
- 22.Hirten, R. P. et al. Development of the ehive digital health app: protocol for a centralized research platform. JMIR Res. Protoc Nov. 16, 12:e49204. 10.2196/49204 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Monitor Your Heart Rate with Apple Watch. Accessed October. 22nd, https://support.apple.com/en-us/HT204666 (2020).
- 24.Live Heart Rate. Accessed December 16. (2023). https://support.ouraring.com/hc/en-us/articles/4410651298963-Live-Heart-Rate
- 25.Shaffer, F. & Ginsberg, J. P. An overview of heart rate variability metrics and norms. Front. Public. Health. 5, 258. 10.3389/fpubh.2017.00258 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Pincus, T. et al. An index of only patient-reported outcome measures, routine assessment of patient index data 3 (RAPID3), in two abatacept clinical trials: similar results to disease activity score (DAS28) and other RAPID indices that include physician-reported measures. Rheumatology (Oxford) Mar.47 (3), 345–349. 10.1093/rheumatology/kem364 (2008). [DOI] [PubMed] [Google Scholar]
- 27.Pincus, T. et al. RAPID3 (Routine assessment of patient index data 3) severity categories and response criteria: similar results to DAS28 (Disease activity Score) and CDAI (Clinical disease activity index) in the RAPID 1 (Rheumatoid arthritis prevention of structural Damage) clinical trial of certolizumab Pegol. Arthritis Care Res. (Hoboken) Aug. 63 (8), 1142–1149. 10.1002/acr.20481 (2011). [DOI] [PubMed] [Google Scholar]
- 28.Pinheiro, J., Bates, D. R. & Core Team _nlme: Linear and Nonlinear Mixed Effects Models_. R package version 3 1–162. https://cran.r-project.org/web/packages/nlme/index.html
- 29.emmeans, R. L. Estimated Marginal Means, aka Least-Squares Means. R package version 1.10.1. https://CRAN.R-project.org/package=emmeans
- 30.Malpas, S. C. & Purdie, G. L. Circadian variation of heart rate variability. Cardiovasc Res Mar.24 (3), 210–213. 10.1093/cvr/24.3.210 (1990). [DOI] [PubMed] [Google Scholar]
- 31.Tabata, M. et al. Cosinor analysis of heart rate variability in ambulatory migraineurs. Headache Jun. 40 (6), 457–463. 10.1046/j.1526-4610.2000.00068.x (2000). [DOI] [PubMed] [Google Scholar]
- 32.Yang, Z. et al. The analysis of circadian rhythm of heart rate variability in patients with drug-resistant epilepsy. Epilepsy Res Oct.146, 151–159. 10.1016/j.eplepsyres.2018.08.002 (2018). [DOI] [PubMed] [Google Scholar]
- 33.Hou, R., Tomalin, L. E. & Suárez-Fariñas, M. CosinoRmixedeffects: an R package for mixed-effects cosinor models. BMC Bioinformatics Nov. 13 (1), 553. 10.1186/s12859-021-04463-3 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Douglas Bates, M. M. & Bolker, B. Steve Walker. Fitting linear Mixed-Effects models using lme4. J. Stat. Softw.67 (1), 1–48. 10.18637/jss.v067.i01 (2015). [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The datasets analyzed during the current study is available from the corresponding author on reasonable request.