Skip to main content
. 2026 Jan 8;38(1):4. doi: 10.1007/s44445-025-00102-2

Table 3.

This table presents a clinical summary of OOKP use

Clinical Parameter Value/Outcome Source
Postoperative Complications

- Prosthetic plate necrosis or rejection: 16.1%

- Secondary glaucoma: 11.5%

Ortiz-Morales G et al. (2022) The evolution of the modified osteo-odonto-keratoprosthesis, (Ortiz-Morales et al. 2022)
Effectiveness of Visual Restoration 83% of patients achieve visual function improvement Liu et al. (2008), Visual rehabilitation in end-stage inflammatory ocular surface disease. (Liu et al. 2008)
Long-Term Stability 85% probability of maintaining an intact OOKP 18 years postoperatively Falcinelli et al. (2005), Modified osteo-odonto-keratoprosthesis for corneal blindness. (Falcinelli et al. 2005 Oct)
Prosthesis Loss 10–20% prosthesis loss due to complications within 10 years De La Paz et al. (2011), Impact of clinical factors on OOKP outcomes. (De La Paz et al. 2011)