Table 3.
Proposed conversion functions between cubes and cylinders for UHPC compressive strength.
| convert 50-mm cubes to 100-mm cubes |
convert 50-mm cubes to 75-mm cylinders |
convert 100-mm cubes to 75-mm cylinders | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Function | p-value | R 2 | Function | p-value | R 2 | Function | p-value | R 2 | |
| Linear with intercept | 0.8x + 12.1 |
< 0.001 < 0.001 |
0.86 | 1.1x + 6.2 |
0.022 < 0.001 |
0.90 | 1.3x − 5.7 |
0.0144 < 0.001 |
0.94 |
| Linear without intercept | 0.90x | < 0.001 | 0.83 | 1.10x | < 0.001 | 0.89 | 1.20x | < 0.001 | 0.94 |
| Power function | 1.50 × 0.9 |
0.0352 < 0.001 |
0.87 | 1.04 × 1.03 |
0.733 < 0.001 |
0.91 | 0.80 × 1.1 |
0.0052 < 0.001 |
0.96 |