TABLE 7.

Maximum stress on the aortic lumen surface under systolic pressure derived from three different groups of in vivo material parameters.

Patient no. Stress from M1 (kPa) Stress from M2 (kPa) Stress from M3 (kPa) Stress RE for M2 (%) Stress RE for M3 (%)
AD1 392.09 392.09 395.27 0.00 0.81
AD2 606.76 545.41 540.91 −10.11 −10.85
AD3 530.88 551.68 548.11 3.92 3.25
AD4 456.02 476.72 470.54 4.54 3.18
AD5 160.71 173.08 171.10 7.70 6.47
N1 272.67 243.54 240.97 −10.68 −11.63
N2 310.33 342.42 341.06 10.34 9.90
N3 218.48 248.70 246.80 13.84 12.97
N4 509.89 487.20 486.31 −4.45 −4.63
N5 252.22 256.25 252.44 1.60 0.09

RE, relative error.