Abstract
The prediction of physiological strain is essential for the safety of personnel in high-risk environments especially when wearing personal protective equipment (PPE). This study aimed to develop a usability-enhanced variant of the Heat Strain Decision Aid (HSDA), named HSDA-FL (FAME Lab), by implementing automatic workload estimations, alternative environmental inputs, and a revised initialization delay logic. The second aim was to evaluate whether these modifications preserved the original model’s validity. The third aim was to evaluate the performance of HSDA, HSDA-FL, and the PHS-FL models while wearing chemical, biological, radiological, and nuclear (CBRN) PPE. Eleven acclimatized participants completed a 40-min simulated CBRN reconnaissance scenario involving walking and inspection tasks. The HSDA-FL was tested with both the original and the revised delay logic, demonstrated significantly lower residual errors than the original HSDA (p<0.001), with the revised delay logic variant achieving the highest accuracy (MAE=0.151°C, RMSE=0.191°C, bias=0.011°C). In contrast, the PHS-FL performed significantly worse than all HSDA-based models (p<0.001). These findings confirm that HSDA-FL maintains and slightly exceeds the predictive validity of the original HSDA while improving usability, whereas PHS-FL was not deemed sufficiently reliable for use with CBRN clothing.
Keywords: Heat stress, Predicted heat strain (PHS), Heat Strain Decision Aid (HSDA), Core body temperature, Chemical, biological, radiological, and nuclear (CBRN) ensemble
Introduction
Exposure to heat stress is a well-recognized challenge in military operations, particularly during prolonged physical work while wearing personal protective equipment (PPE)1, 2). While PPE is essential for protection against environmental and chemical threats, the combined effects of increased thermal insulation and reduced water vapor permeability, imposed by PPE, limit the body’s capacity for heat dissipation and sweat evaporation1,2,3). As a result, core body temperature (Tc) may rise, increasing the risk of reduced performance, cognitive impairment, and potentially serious medical conditions such as exertional heat illness or heat stroke, even among trained personnel1, 3,4,5,6). From 2015 to 2020 over 12,300 exertional heat illness cases were reported in the US military, including more than 2,500 exertional heat stroke events5). Similar trends have been reported globally: 3,551 cases in the UK Armed Forces (2010–2020), 187 in Singapore (2012–2018), 89 in the Netherlands (2012–2020) and 449 in Australia (1997–2005)5).
The impacts of PPE on Tc and, in turn, the risk for heat-related illness may be evaluated using predictive models that can simulate a given scenario and estimate the level of hyperthermia experienced by the average wearer. Two widely used predictive models are the Heat Strain Decision Aid (HSDA)7,8,9) and the ISO-standardized Predicted Heat Strain (PHS)10,11,12). The HSDA has demonstrated strong validity in predicting Tc across diverse environmental conditions and PPE configurations13, 14). However, it presents several usability challenges for field application. It requires manual inputs for mean radiant temperature (Tmr), metabolic rate, and external mechanical work (Wex). These parameters are difficult to estimate accurately without technical expertise or specialized tools7, 8). Also, the model’s initialization delay logic (i.e., the lag of Tc rise during an estimated duration based on metabolic rate) predicts an early dip in Tc during the first minutes of simulation, which contradicts empirical findings showing a stable or gradual rise during the initial phase of exertion15,16,17). If not addressed, these usability challenges reduce the HSDA model’s accessibility for non-expert users and may affect both mission effectiveness and personnel safety.
Similar challenges are also inherent in the widely used PHS model. The PHS has several usability issues for field application and requires manual inputs for parameters that are difficult to estimate accurately without technical expertise or specialized tools. Efforts to address these challenges led to the development of the FAME Lab PHS model (PHS-FL)10) which was recently converted to a free online tool12) and a mobile phone application currently used by NATO allies6). Both the PHS and the PHS-FL have shown promising results in occupational10, 18, 19), athletic12), and laboratory20) settings under various clothing and conditions. However, the original PHS validation was performed with clothing insulation (clo) ranging from 0.1 (wearing underwear) to 1.0 (clothing needed to keep comfortable while sitting at a typical indoor environment)11). Studies that have used the PHS for higher clo values have reported acceptable validity at clo ranging between 1.0 and 2.0, but significant Tc overestimations in non-permeable suits or ensembles with higher clo values2, 20). Therefore, the validity of PHS simulations that include PPE are unclear, while those of the PHS-FL remain unknown.
To address the uncertainties of HSDA and PHS-FL in terms of usability and/or validity while wearing PPE, this study aimed to: (1) develop a usability-enhanced variation of the HSDA model (referred to as HSDA-FL); (2) evaluate whether HSDA-FL maintains the predictive validity of the original HSDA model when used with CBRN ensembles; and (3) compare the validity of HSDA, HSDA-FL and PHS-FL using physiological data collected during a CBRN field reconnaissance mission scenario. In developing HSDA-FL, we aimed to make the model easier to use in real world settings by adding a step-by-step interface to guide users through data entry. Planned improvements included automatic calculators for parameters that are normally difficult to estimate (e.g., metabolic rate from walking speed, terrain, and load, or by selecting values from established activity databases; and Wex from a mechanical efficiency approach), as well as alternative inputs for parameters that are hard to measure directly (e.g., Tmr estimated from globe temperature or solar radiation). These enhancements were designed to reduce the need for technical expertise, avoid unrealistic outputs, and make the model more practical for non-expert users in operational environments.
Methods
HSDA model
The HSDA model predicts Tc and sweat loss under a wide range of environmental and operational scenarios8). Its structure is based on the classical heat exchange principles originally proposed by Givoni and Goldman, and further detailed in Gonzalez and Potter et al.7,8,9, 21, 22). In later versions, the HSDA model was extended to include altitude-related corrections, accounting for changes in atmospheric pressure23). One key adjustment involves the estimation of maximum evaporative capacity which is influenced by atmospheric pressure. In the original formulation maximum evaporative capacity is calculated as9):
| Emax = LR ∙ 6.45 ∙ AD ∙ Cevap∙ ( SVPTsk – Pa ) |
where:
Emax=maximum evaporative capacity (W)
LR=2.2 (°C/Torr)
AD=DuBois24) body surface area (m2)
Cevap=effective clothing evaporation (W)
SVPTsk=saturated vapor pressure at the skin (Torr)
Pa=ambient vapor pressure (Torr)
The altitude-adjusted formulation from the latest versions of the model is given as follows23, 25):
| Emax_A = Patm –0.45 ∙ Emax |
| Patm= (1–2.5577 ∙ 10-5 ∙ Z) 5.2559 |
where:
Emax_A=altitude-adjusted maximum evaporative capacity (W)
Patm=atmospheric pressure (atm)
Z=altitude (m)
In addition to the adjustment of maximum evaporative capacity, the HSDA model also adjusts the calculation of total effective thermal resistance and it is expressed as23):
| ITeff_A = IT ∙ (Patm ∙ Veff ) ITVg |
where:
ITeff_A=altitude-adjusted total effective thermal resistance (clo)
IT=total thermal resistance (clo)
Veff=effective air velocity (m/s)
ITVg=thermal resistance wind velocity coefficient
PHS and PHS-FL models
The current version of the web application retains the PHS and PHS-FL models exactly as implemented in the previous release12). Their internal logic, numerical methods and physiological assumptions remain unchanged with only minor updates made to the user interface layout. These models have been already validated in earlier work10, 12) and are included here without modification. In this study, we focused on PHS-FL rather than the original PHS model, since preliminary sensitivity testing showed that the predictions of the two models were nearly identical under our study conditions (see Discussion for details). As such, no additional enhancement is performed for them in the present study.
HSDA-FL variant
To address usability challenges of the original HSDA model, we developed a modified variant, HSDA-FL, introducing several interface and functional modifications specifically aimed at supporting non-expert users. These modifications improve the ease of input preparation and expand its field applicability while preserving the original HSDA computational framework. In addition to these features, HSDA-FL supports multiple exposure periods following a multi-period implementation similar to that of the PHS-FL model10, 12), however, this functionality was not validated in the present study and a single-period configuration was employed.
Modifications on the HSDA-FL variant
(i) Revised method for Wex estimation
The original HSDA formulation (Potter et al.)7) calculates Wex (W) using the following equation:
| Wex = 0.098 ∙ Grade ∙ (Weight + Load) ∙ Vwalk |
where:
Grade=terrain slope (%)
Weight=body weight (kg)
Load=external load (kg)
Vwalk=walking speed (m/s)
While this formulation incorporates slope, it returns zero Wex on flat terrain (Grade=0), even in situations where there is meaningful mechanical effort. Although Wex is a manual input on the HSDA model, this may be impractical for non-expert users, even when estimated with the model’s provided formula. In a subsequent update, Potter et al. discontinued the slope-based equation and recommended a fixed 80/20 energy split (i.e., 20% external work, 80% heat production) as a best-case efficiency assumption8). To improve usability, avoid zero Wex, and provide a more general solution, HSDA-FL replaces the earlier slope-based approach with a mechanical efficiency-based approach derived from the Fiala model26, 27). The same approach was previously implemented in the PHS-FL software and has been shown to improve heat-strain predictions in occupational settings compared with neglecting external work10). To verify the impact of this modification, we performed a sensitivity analysis comparing predictions from the fixed 20% mechanical efficiency assumption with our dynamic efficiency approach. The analysis showed minimal differences in predicted Tc (MAE ≤ 0.06°C, RMSD ≤ 0.09°C, mean%Error ≤ 0.17%, max%Error ≤ 0.66%).
In this approach, Wex (W) is calculated based on mechanical efficiency as a nonlinear function of metabolic rate:
where:
η=mechanical efficiency (e.g. 0.2 for 20%)
M=metabolic rate (W/m2)
AD=DuBois24) body surface area (m2)
This function levels off mechanical efficiency at ~20% at higher metabolic rates, aligning with Fiala’s observation that efficiency increasing with activity levels, and also with the simplified 80/20 assumption8, 27). Users may either adopt this dynamic method or manually input a value for Wex if preferred.
(ii) Enhancements in environmental and workload inputs
The HSDA-FL’s interface incorporates expanded environmental input options allowing users to enter globe temperature and solar radiation as alternatives to Tmr. To further increase usability when direct measurements of Tmr or globe temperature are unavailable, the interface includes a built-in tool that estimates solar radiation.
Additionally, the interface provides a built-in tool to calculate the metabolic rate based on the Pandolf28, 29) (for flat and inclined terrain) and the Santee28, 30, 31) (for flat and declined terrain) equations. In addition to these tools, users can choose metabolic rates from the latest Compendium of Physical Activities32) and from the estimated cost of typical work tasks in five major industries33, 34).
(iii) Revised Tc initialization logic
The HSDA model includes an initialization delay logic that defines a delay window as a function of metabolic rate, during which it assumes no physiological rise in Tc. Instead, the model predicts an initial decrease in Tc followed by a return to the initial value at the end of this window. However as mentioned in the Introduction section, empirical observations support a gradual rise in Tc during the early phase of physical work, even under high workloads or when wearing protective clothing15,16,17). To better reflect the thermal inertia and gradual onset of internal heat accumulation15, 35), a revised approach may be warranted.
To address this, HSDA-FL applies a revised initialization delay logic using an exponential bridging function that simulates a smooth, progressively rising Tc rather than a dip. The delay duration represents the estimated lag time before Tc begins to rise7, 23) and its calculation is retained from the original HSDA model.
where:
TDWK=delay duration (min)
M=metabolic rate (W)
To ensure a smooth temperature trajectory, the bridging window is extended by 50% of the calculated TDWK, capped at a maximum of 3 min:
This extended window [0, Tbridge] defines the region over which the exponential rise is applied. The function smoothly connects the initial Tc to the predicted value at the end of Tbridge, without introducing any artificial dip. The Tc (°C) during the new delay window is calculated as:
where:
y1=initial core body temperature (°C)
y2=predicted core body temperature at the end of Tbridge (°C)
t=the current timepoint (min)
Importantly, this revised delay logic applies only within the bridging window [0, Tbridge] and does not affect model predictions beyond this new delay period.
Overall software architecture
The developed web application is browser-based, using Flutter front-end and a Python REST API backend to implement established heat-strain models including PHS (ISO 7933:2023)11), the PHS-FL model10), the HSDA model based on the latest description7, 9), and the newly developed variant HSDA-FL.
Hosting is provided via Firebase Hosting with SSL encryption and authentication supporting multiple options (email/password, Google, GitHub) with secure user data handling through Firebase Firestore. For users who prefer not to create an account, anonymous access is available with limited simulation capacity (3 simulations per day). Regardless of the authentication method all data are protected by access rules that ensure only the authenticated user (including anonymous sessions) can access their data. The web application is freely available at https://habitatscience.org/.
Screen flow
The interface is organized into four screens: 1) Landing, 2) Simulation Preparation, 3) Results, and 4) History. Users input the simulation parameters using two modal dialogs, one for participant level data and another for exposure conditions. After completing both dialogs, users initiate the simulation by clicking the “Run Simulation” button, which immediately redirects them to the Results screen while a request is sent to the API.
Basic Information modal
The Basic Information modal contains inputs for the participant-level parameters that remain constant across all exposure periods within a simulation. A toggle button in the upper-right corner allows users to switch between metric and imperial labels affecting only the displayed units (not the underlying values). The layout of this modal is illustrated in Fig. 1 with numbered callouts corresponding to the input fields summarized in Table 1.
Fig. 1.
Basic Information modal (example taken from an HSDA-FL simulation run).
Numbers indicate the 14 different options/buttons on the Basic Information modal that are explained in Table 1.
Table 1. Explanation of the 14 different options/buttons provided on the Basic Information modal, as shown in Fig. 1.
| # | Name | Description |
|---|---|---|
| 1 | Back arrow | Closes the modal and returns to the Simulation Preparation screen without saving. |
| 2 | Clear | Resets all fields in the modal to blank. |
| 3 | Save | Saves the current entries and closes the modal; disabled until all fields are completed. |
| 4 | Metric/Imperial Toggle | Switches unit labels (no conversion of numeric values). |
| 5 | Weight | Body weight of the simulated individual. |
| 6 | Weight Unit Selector | Dropdown for selecting kg or lbs. |
| 7 | Height | Height of the simulated individual. |
| 8 | Height Unit Selector | Dropdown for selecting cm or in. |
| 9 | Days in Heat | Number of acclimatization days; full acclimatization assumed at 12 d. |
| 10 | Dehydration factor | Estimated body mass lost due to dehydration (%); from 0% (euhydrated) to 6% (severely dehydrated). |
| 11 | Initial Core Temperature | Core temperature at simulation start. |
| 12 | Core Temperature Unit Selector | Dropdown for selecting °C or °F. |
| 13 | Initial Skin Temperature | Skin temperature at simulation start. |
| 14 | Skin Temperature Unit Selector | Dropdown for selecting °C or °F. |
Exposure Period modal
The Exposure Period modal contains inputs for the environmental, workload, and clothing parameters for a single exposure period (can be opened multiple times to define multi-period sequences for PHS-FL and HSDA-FL simulations). The layout is shown in Fig. 2 (example from an HSDA-FL run) with numbered callouts corresponding to input fields listed in Table 2. As in the Basic Information modal, a metric/imperial toggle changes units without converting numeric values. Fig. 3, Table 3, Fig. 4.
Fig. 2.
Exposure Period modal (example taken from an HSDA-FL simulation run).
Numbers indicate the 24 different options/buttons on the Exposure Period modal that are explained in Table 2.
Table 2. Explanation of the 24 different options/buttons provided on the Exposure Period modal, as shown in Fig. 2.
| # | Name | Description |
|---|---|---|
| 1 | Back Arrow | Closes the modal and returns to the Simulation Preparation screen without saving. |
| 2 | Clear | Resets all fields in the modal to blank. |
| 3 | Save | Saves the current entries and closes the modal; disabled until all fields are completed. |
| 4 | Metric/Imperial Toggle | Switches unit labels (no conversion of numeric values). |
| 5 | Period Name | User-defined label for the current exposure period. |
| 6 | Duration | Duration of the exposure period (min). |
| 7 | Air Temperature | Dry-bulb air temperature surrounding the body. |
| 8 | Air Temperature Unit Selector | Dropdown for selecting °C or °F. |
| 9 | Relative Humidity | Ambient water vapor content (%). |
| 10 | Radiation Source Selector | Dropdown for selecting a long-wave radiation proxy (Globe temperature, Radiant temperature, or Solar radiation). |
| 11 | Radiation Source Value | Numeric value for the selected radiation source. |
| 12 | Radiation Unit Selector | Dropdown for selecting °C or °F (for Globe and Radiant temperature only). |
| 13 | Altitude | Site elevation in meters (enter 0 if unknown). |
| 14 | Wind Speed | Local air velocity; 0.45 m/s represents still air8). |
| 15 | Wind Speed Unit Selector | Dropdown for selecting m/s or ft/s. |
| 16 | Metabolic Rate | Metabolic rate defined by the user (W/m2). |
| 17 | Metabolic Rate Selector | Switches view to select from two lists: the Compendium of Physical Activities32) and the estimated energy cost for each work descriptions across five industries33, 34). |
| 18 | via Santee / via Pandolf Buttons | Reveals fields for walking speed, terrain slope, and external load. Computes metabolic rate using Santee28, 30, 31) (for decline) or Pandolf28, 29) (for incline); both are available for flat terrain. |
| 19 | Mechanical Efficiency | Portion of metabolic rate converted to external work (W/m2), entered manually. |
| 20 | Mechanical Efficiency Calculator | Auto-calculates mechanical efficiency using a modified Fiala equation10). |
| 21 | Clothing Insulation | Total thermal insulation of the clothing ensemble (clo). |
| 22 | Thermal insulation wind velocity coefficient | Adjustment factor for insulation based on air velocity (clo/Vg). |
| 23 | Evaporative Potential | Permeability index of the clothing system (im/clo). |
| 24 | Evaporative potential wind velocity coefficient | Adjustment factor for evaporative potential based on air velocity (im/cloVg). |
Fig. 3.
Simulation Preparation screen (empty state) from an HSDA-FL simulation run.
Numbers indicate the first 10 interface elements before any input is provided and are explained in Table 3.
Table 3. Explanation of the 16 different interface elements provided on the Simulation Preparation screen, as shown in Fig. 3 (empty state) and Fig. 4 (filled state).
| # | Name | Description |
|---|---|---|
| 1 | Selected Model | Displays the active prediction model (PHS, PHS-FL, HSDA, or HSDA-FL). |
| 2 | Simulation Name | User-defined label for the current scenario. |
| 3 | Edit Simulation Name | Allows editing of the simulation name. |
| 4 | Back to Home | Returns to the Landing screen. |
| 5 | History | Opens the History screen. |
| 6 | Profile Icon | Displays the user’s avatar; reveals logout option when clicked. |
| 7 | Add Basic Information | Opens the Basic Information modal (see Fig. 1). |
| 8 | Add Period | Opens the Exposure Period modal (see Fig. 2). |
| 9 | Add Period (Sidebar) | Sidebar shortcut to open the Exposure Period modal. |
| 10 | Import from Excel (Sidebar) | Launches an import wizard to upload Basic Info and Period data from a provided template (PHS-FL/HSDA-FL only). |
| 11 | Clear Periods (Sidebar) | Removes all exposure periods from the current session. |
| 12 | Period Navigator (Sidebar) | Displays configured periods; supports drag-and-drop reordering. |
| 13 | Edit Basic Information | Reopens the Basic Information modal for editing after initial save. |
| 14 | Timeline Controls | Navigates horizontally between multiple period blocks. |
| 15 | Period Summary Card | Shows name and key parameters of each exposure period, with edit, duplicate, and delete options. |
| 16 | Run Simulation | Sends the configuration to the API and redirects to the Results screen when ready. |
PHS-FL: FAME Lab predicted heat strain model; HSDA-FL: usability-enhanced variation of the Heat Strain Decision Aid.
Fig. 4.
Simulation Preparation screen (filled state) from an HSDA-FL simulation run.
Numbers continue from Fig. 3 and indicate 6 additional elements that appear after Basic Information and at least one Exposure Period has been defined. All interface elements across both states are enumerated continuously and described in Table 3.
Accuracy of the converted Python version of the HSDA model
To validate our Python implementation of the original HSDA model, we created six test scenarios (Table 4) that reflect a variety of environmental and workload conditions. We compared the model’s output against the official Excel-based calculator from Potter et al7). Across the full 120-min simulation period, the Python implementation produced results that were numerically identical to the Excel version (within floating-point precision), with bias, mean absolute error (MAE), and root mean square error (RMSE) equal to 0.000°C and a coefficient of determination (R2) equal to 1.000 in all scenarios. These results confirm the fidelity of our translation of the original HSDA equations into Python.
Table 4. Environmental and workload conditions validate the Python implementation of the original HSDA model.
| Scenario ID | Tair | RH | Tmr | Vwind | M | Wex |
|---|---|---|---|---|---|---|
| S-1 | 35 | 30 | 55 | 1 | 300 | 50 |
| S-2 | 35 | 30 | 35 | 1 | 300 | 50 |
| S-3 | 45 | 15 | 65 | 1 | 300 | 50 |
| S-4 | 35 | 70 | 55 | 1 | 300 | 50 |
| S-5 | 35 | 30 | 55 | 4 | 300 | 50 |
| S-6 | 35 | 30 | 55 | 1 | 500 | 100 |
Tair: air temperature (°C); RH: relative humidity (%); Tmr: mean radiant temperature (°C); Vwind: air velocity (m/s2); M: metabolic rate (W); Wex: external mechanical work (W). HSDA: heat strain decision aid.
Experimental trial
The experimental trial was conducted outdoors between August and September, and was designed to simulate a CBRN field reconnaissance mission scenario. Ethical approval was obtained from the Bioethics and Ethics Committee of the Department of Physical Education and Sport Science at the University of Thessaly, and operational authorization was granted by the Hellenic Army General Staff for the voluntary participation of military personnel and the use of the required materials and equipment.
Eleven healthy volunteers (nine men and two women) habitually acclimatized to the heat from the Hellenic Armed Forces’ Nuclear Biological Chemical Defense Special Joint Battalion participated in the study. All participants were trained in field operations involving CBRN threats and provided written informed consent after receiving a full explanation of the study’s goals and procedures. Participants were instructed to follow their usual dietary habits prior to testing, and all trials were conducted under strict safety and hygiene standards.
Approximately two hours before arriving at the testing location, each participant ingested a telemetry capsule (CorTemp™, Human Technologies, St. Petersburg, FL, USA) for continuous measurement of Tc. Upon arrival, anthropometric measurements were collected using a calibrated scale (KernDE 150K2D, KERN & SOHN GmbH, Balingen, Baden-Württemberg, Germany). The average (± SD) participant characteristics were: age=39 ± 6 yr, body mass=80 ± 11 kg, height=175 ± 9 cm, body surface area=1.95 ± 0.16 m2, and body mass index=26.2 ± 3.2 kg/m2. At that time, participants were wearing the standard Hellenic Armed Forces combat uniform (Uniform N.9). After signing the informed consent and obtaining anthropometric characteristics, they donned their CBRN protective suit and overboots. Final preparation, including donning the helmet, load-carrying equipment, protective mask and gloves, and equipping the chemical agent monitor and rifle, was completed immediately before the trial began. The full protective ensemble including operational equipment weighed approximately 13.7 kg (ammunition excluded for safety reasons).
Each participant then completed a 40-min simulated CBRN reconnaissance scenario involving walking and inspecting on a ~534 m outdoor dirt/clay circuit. Prior familiarization was provided to ensure consistency in operational procedures. Environmental conditions, including air temperature (°C), globe temperature (°C; measured with a 25 mm copper globe and internally converted by the Kestrel 5400FW to the equivalent 150 mm standard globe; ± 1.4°C accuracy), relative humidity (%), and air velocity (m/s), were continuously recorded using a portable weather station (Kestrel 5400FW, Nielsen-Kellerman, Boothwyn, PA, USA). The average (± SD) environmental conditions during testing were 32 ± 3°C ambient air temperature, 41 ± 3°C globe temperature, 39 ± 6% relative humidity and 1.75 ± 1.49 m/s air velocity.
Simulations preparation
All physiological and environmental data collected during the experimental trial were resampled to a 1-min resolution. Higher frequency signals were downsampled using mean values, while lower frequency data were interpolated linearly to align with this resolution.
The HSDA model was run using its original format in which all input parameters were determined by averaging the time-series data recorded during the experimental trial. Walking speed (1.4 ± 0.2 m/s) was used to estimate the metabolic rate using the Santee equation (an extension of Pandolf’s equation with a correction factor), which was developed to extend predictions for flat and negative slopes28,29,30,31). A terrain factor of 1.11 was applied, based on Richmond et al.28), who reported this value for the Santee equation at walking speed 1.55 m/s with an 8 kg load on a dirt road. This coefficient was the closest match with our experimental trial conditions (walking on a dirt terrain while carrying a total load of ~13.7 kg) and was therefore more relevant than the generalized coefficients.
Since direct measurements were not available for the exact clothing configuration used in this study, thermal and evaporative resistance parameters (tested at 1.0 m/s air velocity) were taken from Technical Report No. T15-836). The CB-BA-8 ensemble (1.93 total insulation, clo; 0.15 evaporative potential ratio, im/clo), which includes a Flame-Resistant Army Combat Uniform (FRACU) underlayer and body armor, was selected as the closest match in terms of design and layering, although our experimental trial used a compact military uniform underlayer without body armor. To assess the potential error from this substitution, a sensitivity analysis was conducted using three alternative ensembles from the same report: CB-1 (lowest insulation; 1.42 clo; 0.22 im/clo), CB-4 (lowest evaporative resistance; 1.47 clo; 0.12 im/clo), and CB-BA-6 (similar design but without the FRACU underlayer and chemical protective hood; 1.73 clo; 0.18 im/clo).
The Tmr (°C) was calculated based on the recorded globe temperature using the following equation37, 38):
where:
Tglob=globe temperature (°C)
Tair=air temperature (°C)
Vwind=air velocity (m/s)
Emissivity=0.95
Globe diameter=0.15 (m)
The HSDA-FL variation was applied using the same average input data to be in line with the original HSDA methodology. The Wex in HSDA-FL was estimated using the mechanical efficiency-based method integrated into the web interface as descripted earlier. To evaluate the impact of the revised initial Tc behavior, two simulations were conducted, one using the original delay logic from HSDA and another applying the revised delay logic developed for HSDA-FL. This comparison allowed for direct assessment of whether the revised approach improved model performance under realistic field conditions involving CBRN ensembles.
The PHS-FL model was configured using its built-in multi-period capability. The 1-min resolution data were provided with each exposure period being one minute long. This setup allowed PHS-FL to simulate dynamic environmental and physiological conditions during the 40-min protocol. Mechanical work was estimated using the same method as in the HSDA-FL simulations.
Because participants performed typical low intensity office work (1.3–1.8 METs) prior to arriving at the testing site, we have conducted a ~two-hour preliminary simulation with the validated PHS-FL10, 12). From this preliminary simulation we have observed the individual initial Tc and skin temperature values used on all the tested models/variants for consistency. The average observed initial Tc (37.47 ± 0.34°C) closely agreed with the true initial value measured at the start of the protocol (37.47 ± 0.33°C).
Data analysis
Data preparation, simulations and statistical analysis were performed with the use of Python 3.13.3 and the appropriate scientific packages (Pandas, NumPy, SciPy, Matplotlib, Seaborn, Scikit-learn). The predictions from the models were compared with Tc measurements read from pill-type telemetry sensors.
Performance was evaluated using standard error metrics, including MAE, RMSE, mean bias, and R2, while agreement between predicted and observed values was assessed with Bland–Altman analysis (95% limits of agreement) and Willmott’s index of agreement39), where 1.0 indicates perfect agreement and 0 indicates no agreement40).
Residual (absolute difference between predicted and observed Tc) distributions were tested for normality using the Shapiro–Wilk test, which confirmed non-normality across all models (p<0.001). Spearman’s rank correlation was used to evaluate monotonic association between predicted and observed Tc, and Wilcoxon signed-rank tests were applied to evaluate whether model predictions significantly differed from the observed values.
To evaluate relative improvements in predictive performance, we conducted pairwise comparisons of residual errors between models. Each model pair was analyzed using the Wilcoxon signed-rank test to detect significant differences, and paired Cliff’s delta to calculate the effect size. Positive effect sizes indicated better performance in the second model of the pair.
The level of statistical significance was set at 0.05.
Results
Model performance against observed Tc
All three HSDA-based models demonstrated strong accuracy in predicting Tc (Table 5, Fig. 5). The HSDA-FL variant incorporating the revised delay logic performed slightly better, followed closely by the variant using the original delay logic. The original HSDA model also showed similar performance with only marginally higher errors compared to the HSDA-FL variants. The PHS-FL model had notably higher prediction error metrics compared to all HSDA-based models (Table 5, Fig. 5).
Table 5. Performance metrics of the tested models including mean absolute error (MAE), root mean square error (RMSE), coefficient of determination (R2) correlation, and agreement values.
| Model | MAE (°C) | RMSE (°C) | R2 | Spearman’s (ρ) | Willmott’s (d) |
|---|---|---|---|---|---|
| HSDA-FL (revised delay logic) | 0.151 | 0.191 | 0.878 | 0.953 | 0.962 |
| HSDA-FL (original delay logic) | 0.154 | 0.193 | 0.876 | 0.950 | 0.962 |
| HSDA | 0.169 | 0.211 | 0.851 | 0.934 | 0.958 |
| PHS-FL | 0.253 | 0.292 | 0.715 | 0.939 | 0.919 |
HSDA-FL: usability-enhanced variation of the Heat Strain Decision Aid; PHS-FL: FAME Lab predicted heat strain model.
Fig. 5.
Boxplots illustrating the distribution of absolute residuals ( Predicted−Observed ) for each model.
The blue box spans the interquartile range (IQR), whiskers extend to 1.5 × IQR, and the red line marks the median absolute residual. Light-gray circles overlaid on each box indicate the individual per-minute absolute residuals. HSDA-FL: usability-enhanced variation of the Heat Strain Decision Aid; PHS-FL: FAME Lab predicted heat strain model.
Bland–Altman analysis (Fig. 6) indicated minimal bias and narrow limits of agreement for the HSDA-based models. In contrast, the PHS-FL showed a clear positive bias and wider limits of agreement.
Fig. 6.
Bland–Altman plots showing the agreement between predicted and observed Tc.
(a) HSDA, (b) PHS-FL model, (c) HSDA-FL (original delay logic) and (d) HSDA-FL (revised delay logic). The solid black line represents the zero difference. The dashed red line indicates the mean bias and the dotted gray lines represent the 95% limits of agreement (LoA). HSDA-FL: usability-enhanced variation of the Heat Strain Decision Aid; PHS-FL: FAME Lab predicted heat strain model.
Correlation analyses (Spearman’s rank correlation) showed strong associations between predicted and observed Tc across all models (correlation coefficients ranging from 0.934 to 0.953; Table 5). Willmott’s index of agreement was also high across all models (Willmott’s d ranging from 0.919 to 0.962), with HSDA-based models showing slightly higher agreement.
Wilcoxon signed-rank tests revealed no significant difference between observed and predicted Tc values for the HSDA-FL variant with the original delay logic (p>0.05). However, the HSDA-FL variant with the revised delay logic (p<0.05), as well as the original HSDA and PHS-FL models (p<0.001), differed significantly from the observed Tc values.
Pairwise model comparisons based on prediction errors
Both HSDA-FL variants (i.e., with the original and the revised delay logic) showed significantly lower residuals compared with the original HSDA (Wilcoxon p<0.001). The associated effect sizes (Cliff’s delta) were 0.055 for the variant with the revised delay logic and 0.072 for the original delay logic, indicating that the introduction of the mechanical efficiency-based Wex led to statistically detectable but practically small improvements in prediction accuracy.
When comparing the residual errors of the two HSDA-FL variants, the revised delay logic showed statistically significant smaller residual errors (Wilcoxon p=0.001), yet these differences were deemed negligible in terms of effect size (Cliff’s delta=0.017).
All pairwise comparisons involving PHS-FL demonstrated significantly inferior performance (Wilcoxon p<0.001) with moderate to large effect sizes (Cliff’s delta ranging from 0.340 to 0.411), confirming that the PHS-FL model underperformed relative to the HSDA-based models under the tested conditions.
Discussion
The first two aims of the study were to develop and validate a usability-enhanced variation of the HSDA model, referred to as HSDA-FL, when used with CBRN ensembles. The HSDA is already a well-established model and has been validated across diverse operational scenarios and protective clothing configurations13, 14). It was important to evaluate whether the usability improvements made during this study maintained the predictive reliability of the original HSDA model7, 13). Our results clearly demonstrated that, when used with CBRN ensembles, both HSDA-FL variants (i.e., using the original or the revised delay logic) preserved and slightly improved predictive accuracy compared to the original HSDA model. Although pairwise comparisons of residual errors between HSDA and HSDA-FL variants showed statistically significant improvements (p<0.001), the small magnitude of these differences in error metrics suggests limited practical impact. Compared to previously reported field validation of the HSDA model, which reported MAE and RMSE values of approximately 0.30°C and 0.40°C respectively, and bias of 0.23°C13), the original HSDA in our study showed lower errors and bias. Building on this, the HSDA-FL variants demonstrated slightly better accuracy, with prediction errors (MAE and RMSE) between 0.151 and 0.193, and near-zero bias. These results confirm that all the HSDA-based models performed with the expected accuracy and suggest that the modifications introduced in HSDA-FL contributed meaningfully under the tested scenario.
The third aim of the present study was to compare the predictive performance of HSDA, HSDA-FL, and the PHS-FL during a CBRN field reconnaissance mission scenario. The analysis showed a clear advantage of HSDA-based models, with both HSDA and HSDA-FL variants outperforming PHS-FL, which demonstrated significantly higher errors and a notable positive bias (0.185°C). These results are in line with earlier validations showing that HSDA reliably predicts Tc in military scenarios involving chemical protective clothing and hot, humid environments13). In contrast, the PHS-FL is based on the ISO-standardized PHS model and likely inherits its key limitations, particularly when applied to high-insulation PPE10, 11, 20). Previous studies have reported that PHS tends to overestimate Tc under high-insulation scenarios (>2 clo) and these inaccuracies have been attributed to the PHS model’s empirical formulations, which may not hold under conditions of elevated humidity and vapor pressure20). While PHS-FL introduces improvements in usability and predictive accuracy10, 12), our findings align with concerns raised in previous studies suggesting that, similarly to the PHS, the PHS-FL may not be sufficiently reliable with non-permeable suits or ensembles with clo values >22, 20).
In addition to overall predictive performance, the practical implications of model bias warrant consideration. While the HSDA model tended to overpredict Tc across the protocol, the HSDA-FL variants tracked observed values more closely especially during the first 35 min of the experimental trial (Fig. 7). In minutes 35–40, the HSDA-FL showed a slight negative bias (mean bias: −0.04°C). Based on the data collected in this study, it is unclear whether this trend would persist if the experimental trial were to continue. This divergence highlights an important trade-off for operational use. Overprediction, as seen with HSDA, provides a conservative safety margin by triggering protective measures earlier, which aligns with occupational guidelines that typically adopt ~38.0°C as a safety limit6, 41, 42). Exceeding 38°C is generally considered undesirable, and approaching ~39°C markedly elevates risk, with around 25% of individuals suffering heat-exhaustion collapse at ~39.2°C43). By contrast, underprediction risks failing to identify when Tc approaches the safety limit. This concern is amplified in PPE scenarios, where elevated skin temperature reduces thermal tolerance and heat strain may occur at comparatively lower Tc42). Since our data covered a limited duration, it remains unclear whether HSDA-FL would maintain, reduce, or reverse its slight underprediction in longer protocols. However, from a risk mitigation perspective, a slight overprediction is generally preferable to any degree of underprediction, as it may cause false alarms but avoids missing dangerous heat strain.
Fig. 7.
Mean time series plot comparing the predicted and observed core body temperature (Tc) across all models.
For the final segment of the trial, data represent n=10 due to one participant did not complete the full trial (initial n=11). HSDA-FL: usability-enhanced variation of the Heat Strain Decision Aid; PHS-FL: FAME Lab predicted heat strain model.
Having established the overall safety and accuracy considerations, it is also important to examine how specific refinements introduced in HSDA-FL contributed to these outcomes. In particular, the direct comparison between the original and revised delay logic allowed for the evaluation of the specific contribution of the revised initialization delay approach. The results indicated that this refinement significantly improved predictions (p=0.001) during the early phase of physical work and eliminated the initial dip in Tc observed with the original HSDA model (Fig. 7). Although the improvement was statistically significant, the magnitude of change was relatively small. Nonetheless, this physiological enhancement aligns more closely with empirical observations reported in the literature15,16,17).
Another key improvement of HSDA-FL was the introduction of automated mechanical efficiency-based Wex estimation, particularly beneficial for flat terrain conditions where the original HSDA’s equation yields Wex=0. The revised mechanical efficiency-based calculation enabled accurate estimation of non-zero Wex and significantly improved the validity of the predictions (Wilcoxon p<0.001). However the negligible effect size (Cliff’s delta=0.055–0.072) indicates that this gain, while statistically significant, carried little practical impact on the prediction accuracy. In operational terms, such small effect sizes mean that users would not notice meaningful differences in Tc predictions between the two methods. The main benefit of this enhancement is therefore not a large improvement in prediction accuracy, but greater robustness of the model.
In practice, the usability enhancements of HSDA-FL addressed key limitations of the original HSDA. In this study, Tmr was estimated using globe temperature as an alternative input, Wex was derived from an automated mechanical efficiency-based approach and metabolic rate was calculated automatically from walking speed, terrain, and load. By limiting the need for manual calculations and technical expertise, these features further reduced input uncertainty and made the model more accessible for field application. Together, these changes represent its most practical contribution for field usability.
Despite the promising results, this study has several limitations. The sample size was relatively small (n=11 participants) and involved a specific group of Hellenic Armed Forces who have received training in CBRN threats. While our study provides important insights into this target group, the generalizability of these findings to broader military populations or other occupational settings may be questioned. The field tests were carried out in a specific environmental setting (outdoors, August–September in Greece) and validation across a wider variety of climates (for example, hot-dry, cool, humid), larger and more diverse populations and different types of PPE remain essential. Another limitation relates to the biophysical clothing characteristics used for modeling. Since direct measurements were not available for the exact ensemble, we used the CB-BA-8 configuration from Technical Report No. T15-836) as the closest match. Although CB-BA-8 includes a FRACU underlayer and body armor, which were not present in our protocol, our sensitivity analysis with alternative ensembles showed minimal differences in predicted Tc (MAE ≤ 0.05°C, RMSD ≤ 0.07°C, mean%Error ≤ 0.13%, max%Error ≤ 0.49%). This suggests that any error introduced by substituting CB-BA-8 was negligible in practical terms. Similarly, the original PHS model was not tested separately in this study, as a sensitivity analysis comparing the original PHS and PHS-FL predictions showed only minimal differences under our experimental conditions (MAE=0.010°C, RMSD=0.015°C, mean%Error=0.00%, max%Error=0.21%). In addition, mechanical efficiency Wex estimation method does not explicitly include terrain slope, but it is indirectly reflected via its impact on metabolic rate. A further limitation is that the experimental trial duration (40 min) reflects a single realistic work task while wearing CBRN ensembles, as continuous exercise in such PPE under hot conditions is generally limited to ~30–60 min44, 45). However, many other real-world scenarios involving PPE can have longer durations, which should be considered in future studies. Lastly, while the HSDA-FL supports multiple exposure periods following a multi-period implementation similar to the validated approach incorporated in the PHS-FL model10, 12), the experimental design adopted did not allow validating this functionality in the present study. This was because the environmental and walking speed were mostly stable throughout the experimental trial. Future research should address these limitations by incorporating more diverse populations, broader climate conditions, and various PPE ensembles, while also validating the multi-period functionality under dynamic operational workflows.
In conclusion, this study successfully developed and validated the HSDA-FL model demonstrating that it maintains and slightly exceeds the original HSDA’s predictive validity when tested for CBRN clothing, while providing meaningful improvements in usability. On the other hand, the PHS-FL was not deemed sufficiently reliable for use with CBRN clothing. These findings significantly extend the practical applicability of heat strain modeling tools in military and occupational settings where accurate predictions of heat stress are essential for safety and performance management1,2,3,4,5).
Conflict of Interest
None.
Acknowledgments
The authors wish to express their gratitude to the Hellenic Army General Staff for the operational authorization of the study.
References
- 1.O’Brien C, Blanchard LA, Cadarette BS, Endrusick TL, Xu X, Berglund LG, Sawka MN, Hoyt RW. (2011) Methods of evaluating protective clothing relative to heat and cold stress: thermal manikin, biomedical modeling, and human testing. J Occup Environ Hyg 8, 588–99. [DOI] [PubMed] [Google Scholar]
- 2.Lunerová K, Řehák Kopečková B, Pokorný J, Mašín M, Kaiser D, Fialová V, Fišer J. (2023) Applicability of human thermophysiological model for prediction of thermal strain in PPE. Appl Sci (Basel) 13, 7170. [Google Scholar]
- 3.Montain SJ, Sawka MN, Cadarette BS, Quigley MD, McKay JM. (1994) Physiological tolerance to uncompensable heat stress: effects of exercise intensity, protective clothing, and climate. J Appl Physiol 77, 216–22. [DOI] [PubMed] [Google Scholar]
- 4.Taylor NAS, Patterson MJ. (2016) Military clothing and protective material: protection at the limits of physiological regulation. In: The mechanobiology and mechanophysiology of military-related injuries, Gefen A, Epstein Y (Eds.), 303–32, Springer International Publishing, Cham. [Google Scholar]
- 5.Buller MJ, Delves SK, Fogarty AL, Veenstra BJ. (2021) On the real-time prevention and monitoring of exertional heat illness in military personnel. J Sci Med Sport 24, 975–81. [DOI] [PubMed] [Google Scholar]
- 6.Ioannou LG, Ciuha U, Fisher JT, Tsoutsoubi L, Tobita K, Bonell A, Cotter JD, Kenny GP, Flouris AD, Mekjavic IB. (2023) Novel technological advances to protect people who exercise or work in thermally stressful conditions: a transition to more personalized guidelines. Appl Sci (Basel) 13, 8561. [Google Scholar]
- 7.Potter AW, Blanchard LA, Friedl KE, Cadarette BS, Hoyt RW. (2017) Mathematical prediction of core body temperature from environment, activity, and clothing: the heat strain decision aid (HSDA). J Therm Biol 64, 78–85. [DOI] [PubMed] [Google Scholar]
- 8.Potter A, Looney DP, Gonzalez J, Hancock J, Sanford D, Rioux T, Vangala S, Castellani M, Blanchard L. (2021) Heat strain decision aid (HSDA): Review of input ranges, default values, and example inputs and outputs for verification of external implementation. US Army Research Institute of Environmental Medicine, Natick. [Google Scholar]
- 9.Gonzalez RR, McLellan TM, Withey WR, Chang SK, Pandolf KB. (1997) Heat strain models applicable for protective clothing systems: comparison of core temperature response. J Appl Physiol 83, 1017–32. [DOI] [PubMed] [Google Scholar]
- 10.Ioannou LG, Tsoutsoubi L, Mantzios K, Flouris AD. (2019) A free software to predict heat strain according to the ISO 7933:2018. Ind Health 57, 711–20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.International Organization for Standardization (2023) ISO 7933: Ergonomics of the thermal environment—analytical determination and interpretation of heat stress using calculation of the predicted heat strain. International Organization for Standardization, Geneva. [Google Scholar]
- 12.Mantzios K, Ioannou LG, Nikolaki E, Gkiata P, Charachousou G, Tsoutsoubi L, Dinas PC, Flouris AD. (2024) Validation of core, rectal and skin temperature predictions of a free web-based predictive heat strain software based on the ISO 7933: 2023 standard in recreational athletes. J Sci Sport Exerc 6, 303–14. [Google Scholar]
- 13.Potter AW, Hunt AP, Cadarette BS, Fogarty A, Srinivasan S, Santee WR, Blanchard LA, Looney DP. (2019) Heat Strain Decision Aid (HSDA) accurately predicts individual-based core body temperature rise while wearing chemical protective clothing. Comput Biol Med 107, 131–6. [DOI] [PubMed] [Google Scholar]
- 14.Waldock KAM, Lee BJ, Powell S, Wardle SL, Blacker SD, Myers SD, Maroni TD, Walker FS, Looney DP, Greeves JP, Potter AW. (2021) Field validation of The Heat Strain Decision Aid during military load carriage. Comput Biol Med 134, 104506. [DOI] [PubMed] [Google Scholar]
- 15.Kenny GP, Reardon FD, Thoden JS, Giesbrecht GG, Kenny G. (1999) Changes in exercise and post-exercise core temperature under different clothing conditions. Int J Biometeorol 43, 8–13. [DOI] [PubMed] [Google Scholar]
- 16.Teunissen LP, de Haan A, de Koning JJ, Daanen HA. (2012) Telemetry pill versus rectal and esophageal temperature during extreme rates of exercise-induced core temperature change. Physiol Meas 33, 915–24. [DOI] [PubMed] [Google Scholar]
- 17.Tipton MJ, Kadinopoulos P, de Sa DR, Barwood MJ. (2017) Changes in lung function during exercise are independently mediated by increases in deep body temperature. BMJ Open Sport Exerc Med 3, e000210. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Malchaire JB. (2006) Occupational heat stress assessment by the Predicted Heat Strain model. Ind Health 44, 380–7. [DOI] [PubMed] [Google Scholar]
- 19.Abbasi M, Golbabaei F, Yazdanirad S, Dehghan H, Ahmadi A. (2024) Validity of ten analytical heat stress indices in predicting the physiological parameters of people under various occupational and meteorological conditions. Int J Biometeorol 68, 163–77. [DOI] [PubMed] [Google Scholar]
- 20.Wang F, Kuklane K, Gao C, Holmér I. (2011) Can the PHS model (ISO7933) predict reasonable thermophysiological responses while wearing protective clothing in hot environments? Physiol Meas 32, 239–49. [DOI] [PubMed] [Google Scholar]
- 21.Givoni B, Goldman RF. (1972) Predicting rectal temperature response to work, environment, and clothing. J Appl Physiol 32, 812–22. [DOI] [PubMed] [Google Scholar]
- 22.Givoni B, Goldman RF. (1973) Predicting heart rate response to work, environment, and clothing. J Appl Physiol 34, 201–4. [DOI] [PubMed] [Google Scholar]
- 23.Matthew WT, Berglund L, Santee W, Gonzalez R. (2003) USARIEM heat strain model: new algorithms incorporating effect of high terrestrial altitude. US Army Research Institute of Environmental Medicine, Natick. [Google Scholar]
- 24.Du Bois D, Du Bois EF. (1989) A formula to estimate the approximate surface area if height and weight be known. 1916. Nutrition 5, 303–11, discussion 312–3. [PubMed] [Google Scholar]
- 25.Nishi Y, Gagge AP. (1977) Effective temperature scale useful for hypo- and hyperbaric environments. Aviat Space Environ Med 48, 97–107. [PubMed] [Google Scholar]
- 26.Havenith G, Fiala D. (2015) Thermal indices and thermophysiological modeling for heat stress. Compr Physiol 6, 255–302. [DOI] [PubMed] [Google Scholar]
- 27.Fiala D. (1998) Dynamic simulation of human heat transfer and thermal comfort. [Google Scholar]
- 28.Richmond PW, Potter AW, Santee WR. (2015) Terrain factors for predicting walking and load carriage energy costs: review and refinement. J Sport Human Perform 3, 1–26. [Google Scholar]
- 29.Pandolf KB, Givoni B, Goldman RF. (1977) Predicting energy expenditure with loads while standing or walking very slowly. J Appl Physiol 43, 577–81. [DOI] [PubMed] [Google Scholar]
- 30.Santee WR, Blanchard LA, Speckman KL, Gonzalez JA, Wallace RF. (2003) Load carriage model development and testing with field data. US Army Research Institute of Environmental Medicine, Natick. [Google Scholar]
- 31.Santee WR, Small MG, Blanchard LA. (2003) Application of energy cost algorithms for load carriage to field data. J Hum Environ Syst 6, 69–76. [Google Scholar]
- 32.Herrmann SD, Willis EA, Ainsworth BE, Barreira TV, Hastert M, Kracht CL, Schuna JM, Jr, Cai Z, Quan M, Tudor-Locke C, Whitt-Glover MC, Jacobs DR., Jr2024) 2024 Adult Compendium of Physical Activities: a third update of the energy costs of human activities. J Sport Health Sci 13, 6–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Eurostat (2008) N.A.C.E rev. 2–statistical classification of economic activities in the European Community, Office for Official Publications of the European Communities, Luxemburg.
- 34.Poulianiti KP, Havenith G, Flouris AD. (2019) Metabolic energy cost of workers in agriculture, construction, manufacturing, tourism, and transportation industries. Ind Health 57, 283–305. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Saltin B, Hermansen L. (1966) Esophageal, rectal, and muscle temperature during exercise. J Appl Physiol 21, 1757–62. [DOI] [PubMed] [Google Scholar]
- 36.Potter A, Gonzalez J, Karis AJ, Blanchard L, Rioux T, Santee W. (2015) Biophysical characteristics of chemical protective ensembles with and without body armor. US Army Research Institute of Environmental Medicine, Natick. [Google Scholar]
- 37.Ramsey JD, Bernard TE. (2001) Heat stress. In: Patty’s industrial hygiene, Harris R (Eds.), John Wiley & Sons, New York. [Google Scholar]
- 38.Ioannou LG, Mantzios K, Tsoutsoubi L, Notley SR, Dinas PC, Brearley M, Epstein Y, Havenith G, Sawka MN, Bröde P, Mekjavic IB, Kenny GP, Bernard TE, Nybo L, Flouris AD. (2022) Indicators to assess physiological heat strain—part 1: systematic review. Temperature (Austin) 9, 227–62. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Willmott CJ, Robeson SM, Matsuura K. (2012) A refined index of model performance. Int J Climatol 32, 2088–94. [Google Scholar]
- 40.Willmott CJ. (1981) On the validation of models. Phys Geogr 2, 184–94. [Google Scholar]
- 41.Turner D. (1969) Health factors involved in working under conditions of heat stress. Br J Ind Med 26, 346. [Google Scholar]
- 42.Davey SL, Downie V, Griggs K, Havenith G. (2021) The physiological strain index does not reliably identify individuals at risk of reaching a thermal tolerance limit. Eur J Appl Physiol 121, 1701–13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Coco A, Jacklitsch B, Williams J, Kim JH, Musolin K, Turner N. (2016) Criteria for a recommended standard: Occupational exposure to heat and hot environments. DHHS (NIOSH) Publication. [Google Scholar]
- 44.Maley MJ, Minett GM, Bach AJE, Stewart KL, Stewart IB. (2020) Extending work tolerance time in the heat in protective ensembles with pre- and per-cooling methods. Appl Ergon 85, 103064. [DOI] [PubMed] [Google Scholar]
- 45.McLellan TM, Bell DG, Dix JK. (1994) Heat strain with combat clothing worn over a chemical defense (CD) vapor protective layer. Aviat Space Environ Med 65, 757–63. [PubMed] [Google Scholar]







