Abstract
This study evaluated the effects of evaporative cooling using a water-soaked inner t-shirt with a ventilation garment on physiological and perceptual responses during walking in Hot/Dry (40°C, 30% relative humidity) and Warm/Humid (32°C, 80% relative humidity) environments (wet-bulb globe temperature [WBGT] 31.5°C). Eight men performed a 60-min moderate-intensity exercise protocol under control (CON, fan-off of a ventilation jacket while wearing a dry inner t-shirt) and evaporative cooling conditions (EVA, fan-on of a ventilation jacket while wearing an inner t-shirt soaked with 350 ml of tap water) in each environment. Rectal temperature was ~0.4°C lower during exercise in EVA than CON in both Hot/Dry (37.7 ± 0.4 vs. 38.1 ± 0.3°C, p=0.001) and Warm/Humid (37.8 ± 0.4 vs. 38.2 ± 0.4°C, p=0.002), with no difference between environments. Whole-body sweat loss in EVA was halved compared to CON in both Hot/Dry (0.56 ± 0.12 vs. 1.08 ± 0.23 kg, p<0.001) and Warm/Humid (0.47 ± 0.10 vs. 1.12 ± 0.21 kg, p<0.001). Thermal sensation and discomfort were lower in EVA than in CON in both environments (both p<0.05). Thus, wearing a water-soaked inner t-shirt with a ventilation garment helps mitigate thermophysiological and perceptual responses in environments where ambient temperature exceeds skin temperature and in high humidity (≤ WBGT 31.5°C).
Keywords: Core temperature, Sweat loss, Cooling, Occupational heat strain, Thermal perception
Introduction
Evaporative cooling via sweating is the most efficient mechanism for heat dissipation in human thermoregulation. Supplemental skin wetting also helps mitigate physiological and perceptual heat strain1,2,3). Song et al.1) reported that soaking a t-shirt and short pants inhibited increases in core temperature (Tcore) by ~0.2°C while resting at ambient temperature (Ta) of 43°C and 57% relative humidity (RH) for 90 min. Morris et al.2) found that dousing the skin with water limited the increase in heart rate (HR) by ~5 beats/min, inhibited sweat loss, and alleviated thermal discomfort while resting at 40°C and 50% RH and 47°C and 10% RH for 120 min without affecting Tcore. Similarly, Cramer et al.3) reported that soaking a t-shirt limited the increase in Tcore by ~0.2°C, HR by ~5 beats/min, and sweat losses while resting at 42°C and 34% RH for 120 min. At rest, wearing a water-soaked t-shirt mitigated physiological and perceptual heat strain.
During exercise, when metabolic heat production is higher, supplemental skin wetting is effective when combined with ventilation garments that take in outside air using two fans on the lower back4). Wearing a water-soaked inner t-shirt while using ventilation garments’ fans inhibited the increase in Tcore by ~0.4°C, HR by ~10 beats/min, sweat loss, and thermal sensation during exercise at 37°C and 50% RH for 60 min compared with wearing a dry inner t-shirt4). A higher air velocity over the skin surface promotes evaporative heat loss, provided that the skin surface is sufficiently covered with sweat or water-soaked clothing3, 5). However, fanning also exacerbates the rate of convective heat gain in air temperatures exceeding mean skin temperature (Tskin), which usually occurs above ~35°C. In fact, Cramer et al.3) showed that wearing a wet t-shirt facing an electric fan at 42°C (34% RH) caused greater Tcore increases than no fanning. The improvement in evaporative heat loss using a water-soaked t-shirt was offset by the added convective heat gain due to fanning under extreme heat. In Tokizawa4), higher Ta settings above 37°C may cancel the beneficial effects of wearing a wetted inner t-shirt. Additionally, because the evaporative heat loss is limited with a narrower shirt-to-air vapor pressure gradient, a higher RH (higher vapor pressure) can also increase physiological and perceptual heat strain.
This study aimed to evaluate the effects of a water-soaked t-shirt while wearing ventilation garments on exercise-induced physiological and perceptual heat strain in Hot/Dry (40°C, 30% RH) and Warm/Humid (32°C, 80% RH) environments. Both conditions correspond to wet-bulb globe temperature (WBGT) of 31.5°C, same as in Tokizawa4) (37°C, 50% RH). It was hypothesized that wearing a water-soaked t-shirt in combination with fanning of ventilation garments in Hot/Dry and Warm/Humid environments would offset evaporative heat loss, leading to a similar level of physiological and perceptual heat strain in a dry t-shirt/ventilation garments’ fans off.
Materials and Methods
Participants
Eight healthy men were recruited for this study (age 30 ± 6 yr; height 169 ± 3 cm; body mass 58.7 ± 7.0 kg; maximal oxygen uptake 47.9 ± 10.7 ml/kg/min). All participants were recreationally active and free from illnesses and injuries. Participants were nonsmokers and had no history of cardiovascular disease, skin/sweat-related conditions, or neuromuscular disorders. All the experimental procedures were approved by the Human Research Ethics Committee of the National Institute of Occupational Safety and Health, Japan (2021N40). The participants were informed of the experimental procedures and potential risks, and all signed consent forms. The study was conducted in accordance with the latest version of the Declaration of Helsinki, except for registration in the database.
Experimental design
Volunteers visited the laboratory on five separate occasions, including a pre-experimental and familiarization session and four experimental trials. The four trials [control (CON) and evaporative cooling (EVA) trials in each Hot/Dry and Warm/Humid environments] were randomized (at least 72 h between each trial) and conducted between 13:00 and 17:00 h. The volunteers refrained from consuming any beverages containing caffeine or alcohol the night before the experiment. They ate a light meal, drank ~500 ml of water 2 h before the experiment, and then reported to the laboratory. After voiding completely, each volunteer entered a thermoneutral room at an ambient temperature (Ta) of 25°C and 50% RH. The following protocols were the same as those in a Tokizawa4), except for the environmental conditions (room temperature and RH).
Pre-experimental session
In this pre-session, all volunteers completed a maximal exercise test on a treadmill (SportsArt Fitness T650, Woodinville, WA, USA) at a Ta of 25°C and 50% RH using a metabolic analyzer (AE-310s, Minato Medical Science, Osaka, Japan). The test was a modified ramp protocol consisting of a 2 min warmup of 2.5 km/h and 0% gradient followed by an increase in speed by 0.5 km/h every 2 min. After reaching 4.5 km/h, the gradient was increased by 3% every 2 min until it reached 15%. Then, the speed was increased by 0.5 km/h every 2 min at the 15% gradient until participants reached volitional exhaustion. To prescribe the walking speeds and gradients for the main trials, the rates of metabolic energy expenditure (M) and heat production were estimated for each participant using data from the maximal exercise test, as shown in Appendix A.
Experimental protocol
Participants wore a long-sleeved t-shirt (100% cotton, 160 g), a ventilation jacket (100% cotton, 430 g), undershorts (100% polyester, 80 g), work pants (100% cotton, 315 g), socks (100% cotton, 40 g), and shoes in all trials. The intrinsic clothing insulation value of the jacket was 0.21 clo and that for the total clothing was 0.53 clo, which was determined using a thermal manikin (Thermal manikin, Kyoto Electronics Manufacturing Co., Ltd., Tokyo, Japan). A t-shirt was selected to allow each participant to adhere tightly to their body surface. A long-sleeved t-shirt was used to increase the wet surface area The ventilation jacket (KU91400, Kuchofuku, Tokyo, Japan) was long-sleeved and equipped with two fans (8 cm blade diameter, 194 g) on the lower back. The fans used a battery box (4 AA nickel-metal hydride, 140 g) and were took in outside air. Based on evidence that heat loss increased with ventilation flow rates6), the airflow rate of each fan was set to the maximum the apparatus allows (15.1 L/s). The jacket was tightened around the waist with an elastic band and air was exhausted from the cuff and neck openings. The airflow velocity underneath clothing was 4.5, 2.5, and 7.0 m/s at the cuff, in front of the neck, and behind the neck, respectively (measured using an anemometer; 6006, Kanomax Japan Inc., Osaka, Japan).
After baseline measurements at 25°C (50% RH, <0.3 m/s air velocity) for 10 min, the t-shirt was soaked with 350 ± 5 ml of tap water (37°C) using an electric vaporizer in the EVA trials, and water was never added later. This amount of water was selected to saturate the t-shirt without leaving dry spots or dripping. To ensure the volume of water, the clothed body weight was measured before and immediately after the soaking (± 5 g error) because the participants had trouble wearing a pre-determined and pre-soaked t-shirt. Simultaneously, fans of the ventilation jacket were turned on during the EVA trials. In the CON trials, the participants remained seated and the fans remained off. After each preparation of the clothing for 10 min, the room temperature and RH was set to 40°C and 30% RH in the Hot/Dry and 32°C and 80% RH in the Warm/Humid environment, and stabilized within 10 min. In each environment, WBGT was 31.5°C using a WBGT index measurement instrument (QUESTemp, Quest Technologies, Oconomowoc, WI, USA). The participants were seated during clothing preparation and environment stabilization (Rest period, 0–20 min), and then performed three 20-min bouts of walking exercise (Ex1, Ex2, and Ex3) separated by 10-min breaks (B1, B2, and B3), which are represented in the bottom of Figs. 1, 2, 3 . The walking was conducted at a predefined speed (all participants, 4.5 km/h) and gradient (8.1 ± 1.8%) for a target heat production of 200 W/m2 on the treadmill (%VO2peak, 42 ± 9% as averaged across trials). During the breaks, drinking water (37°C) was provided ad libitum.
Fig. 1.
Rectal temperature (A), mean skin temperature (B), and heat rate (C) responses during three bouts of intermittent exercise (Ex1–3) in the Hot/Dry (40°C, 30% RH) or Warm/Humid (32°C, 80% RH) environments interspersed by three breaks (B1–3) and in the control (CON, wearing a dry inner t-shirt without ventilation garment fanning) and evaporative cooling (EVA, wearing a wetted inner t-shirt with ventilation garments fanning) trials.
The arrow indicates the start of wetting and fanning (EVA). *Significant difference for CON vs. EVA trial in Hot/Dry environment, p<0.05. #Significant difference for CON vs. EVA trial in Warm/Humid environment, p<0.05. §Significant difference for Hot/Dry vs. Warm/Humid environment in the CON trial, p<0.05. †Significant difference for Hot/Dry vs. Warm/Humid environment in the EVA trial, p<0.05. Data are expressed as the mean ± SD for eight participants. CON: control; EVA: evaporative cooling.
Fig. 2.
Perceptual responses during three bouts of intermittent exercise (Ex1–3) in the Hot/Dry (40°C, 30% RH) or Warm/Humid (32°C, 80% RH) environments interspersed by three breaks (B1–3) and in the control (CON, wearing a dry inner t-shirt without ventilation garment fanning) and evaporative cooling (EVA, wearing a wetted inner t-shirt with ventilation garments fanning) trials.
*Significant difference for CON vs. EVA trial in Hot/Dry environment, p<0.05. #Significant difference for CON vs. EVA trial in Warm/Humid environment, p<0.05. †Significant difference for Hot/Dry vs. Warm/Humid environment in the EVA trial, p<0.05. Data are expressed as the mean ± SD for eight participants. CON: control; EVA: evaporative cooling.
Fig. 3.
Clothing microclimate temperature (A) and relative humidity (B) in the ventilation jacket, and skin wettedness of the upper body (C) in the Hot/Dry (40°C, 30% RH) or Warm/Humid (32°C, 80% RH) environments and in the control (CON, wearing a dry inner t-shirt without ventilation garment fanning) and evaporative cooling (EVA, wearing a wetted inner t-shirt with ventilation garments fanning) trials.
*Significant difference for CON vs. EVA trial in Hot/Dry environment, p<0.05. #Significant difference for CON vs. EVA trial in Warm/Humid environment, p<0.05. §Significant difference for Hot/Dry vs. Warm/Humid condition in the CON trial, p<0.05. †Significant difference for Hot/Dry vs. Warm/Humid environment in the EVA trial, p<0.05. Data are expressed as the mean ± SD for eight participants. CON: control; EVA: evaporative cooling.
Measurements
Physiological measurements. The rectal temperature (Trec) was measured continuously using a thermistor probe (701 J, Nikkiso-Therm, Tokyo, Japan) self-inserted 13 cm beyond the rectal sphincter. Skin temperature (Tskin) of the chest, abdomen, back, forearm, upper arm, thigh, and lower leg was measured every 10 s using a temperature/humidity logger (DS1923 iButton Hydrochron; Maxim Integrated, San Jose, CA, USA)7, 8). The temperature/humidity loggers were placed on the skin. A temperature sensor was located at the bottom of the logger to measure skin surface temperature. The humidity sensor was located at the top of the logger, and the air humidity was estimated to be approximately 6 mm above the skin surface. The mean Tskin value was calculated using the Ramanathan weighting system9).
Sweat rate (SR) on the chest, back, forearm, and thigh was monitored using dew point hygrometry (OKS-04HM, ASE Giken, Nagoya, Japan). A ventilated plastic capsule was attached to each skin region. The index of skin blood flow on the chest, back, and forearm was measured using a laser Doppler flowmetry (LDF; FLO-C1, Omegawave, Tokyo, Japan) located adjacent to the ventilated capsule at a sampling rate of 1/1,000 s. To avoid movement of the arms and trunk during the assessment of LDF, the participants held handrails for 30 s every 5 min. Because large movements of the legs during walking disturb the LDF reading, measurements on the legs were not recorded. HR was recorded using an electrocardiogram (BSM-3400; Nihon Koden, Tokyo, Japan). Arterial blood pressure was measured every 5 min using an electrosphygmomanometer (EBP-330, Minato Medical Science), and the mean arterial pressure was calculated as 1/3 (pulse pressure) + diastolic blood pressure. Cutaneous vascular conductance (CVC) was calculated as the LDF value divided by the mean arterial pressure and expressed as a percentage change from the baseline value.
Perceptual measurements. Participants rated their thermal sensation, thermal comfort, thirst sensation, and fatigue separately by drawing a cross line on a visual analog scale (VAS). The subjective ratings of thermal sensation and comfort used a 20 cm VAS; “coldest” or “most uncomfortable” were scored as −10 cm, “hottest” or “most comfortable” were scored as 10 cm, and “neutral” was scored as 011). To evaluate thirst and fatigue, the minimum VAS rating was scored as 0 (not thirsty or fatigued at all) and the maximum rating was 10 cm (extremely thirsty or fatigued). The ratings were conducted at baseline, immediately before the Ta elevation and Ex1, and at the end of Ex1–Ex3 and B1–B3.
Metabolic, weight, and clothing measurements. Metabolic rate was measured using a metabolic analyzer before and during exercise. Heat production during exercise was calculated using 5–20 min of data for each walking period. Partitional calorimetry was used to estimate the evaporative and dry heat losses and the rates of heat storage (see Appendix C). Body mass was measured using a precision balance with ± 1 g accuracy (F150S, Sartorius, Goettingen, Germany) before and after the experiment with the participant wearing only undershorts. The total sweat loss was calculated as follows: body mass loss + weight of ingested water (kg). Upon completion of the experiment, the participants immediately removed their clothing, and the weight of each piece of clothing was measured. The moisture content of each clothing item was calculated as its weight at the end of the experiment (g) − the weight of dry clothing before dressing (g). The clothing microclimate temperature (Tcmc) and relative humidity (RHcmc) between the ventilation jacket and the t-shirt around the chest were also measured using two loggers placed on the inside of the jacket: one was set with a temperature sensor up, and the other was set with a humidity sensor up. To prevent touching the t-shirt, each sensor was covered with a 12-mm high plastic mesh cage. The local skin wettedness was calculated using Gagge’s method10) (see Appendix B).
Statistical analysis
An a priori sample-size calculation was performed (G*Power 3.1.9.612)) using data from our previous investigations that employed at similar experimental model (Trec and Sweat loss). This indicated that we would need ≥8 participants per group to find statistical significance with an effect size of 0.4, a power of 0.9 and alpha set to 0.05.
Single time-point data (total sweat loss, total volume of water ingested, body mass loss, and clothing mass) were evaluated using two-way analysis of variance (ANOVA) for repeated measurements with trials (CON and EVA) and environments (Hot/Dry and Warm/Humid). All other data were analyzed using a three-way repeated-measures ANOVA with trials, environments, and time. If a significant interaction was observed, post-hoc paired-sample t-tests were used to further analyze the effects of trials or environments using the Bonferroni method (physiological data) and Friedman’s test (perceptual data). Statistical significance was set at p<0.05. Analyses were performed using commercially available software (IBM SPSS Statistics v. 21; IBM Corp., Armonk, NY, USA). To ascertain the magnitude of the effect, Hedge’s g (g) was calculated13). All variables are reported as the mean ± standard deviation (SD).
Results
Statistical analysis
Main effects of time were detected for Trec, Tskin, regional SR, CVC, HR, heat production, rating scores, Tcmc, and RHcmc (all p<0.05). The main effect of the trial was significant for Trec, Tskin, regional SR, CVC, HR, heat production, whole-body sweat loss, total volume of water ingested, body mass loss, rating scores of thermal sensation and comfort, moisture content of t-shirt and other clothing, Tcmc, and RHcmc in both the Hot/Dry and Warm/Humid environments (all p<0.05). A significant main effect of the environment was detected for Tskin, Tcmc, RHcmc, and skin wettedness of the upper body (both p<0.01). Furthermore, a significant interaction effect of time × trial (all p<0.05) was detected for Trec, Tskin, regional SR, CVC, HR, heat production, and rating scores of thermal sensation and comfort, Tcmc, RHcmc, and skin wettedness of the upper body in both environments. The interaction effect of trial × environment was detected for whole-body sweat loss, body mass loss, and the moisture content of t-shirts and other clothing (all p<0.05). A time × trial × environment interaction effect was detected for Tskin, Tcmc, RHcmc skin wettedness of the upper body, evaporative and dry heat losses, and rates of heat storage (all p<0.05).
Physiological responses
Trec was lower in the EVA trials than in the CON trials at 70–110 min (Fig. 1A) in both the Hot/Dry (peak: 37.7 ± 0.4 vs. 38.1 ± 0.3°C; p<0.05) and Warm/Humid (peak: 37.8 ± 0.4 vs. 38.2 ± 0.4°C; p<0.05) environments. The mean Tskin was also lower in EVA than in CON at 5–110 min in both environments (Fig. 1B, both p<0.01). In CON, the mean Tskin was lower in the Warm/Humid environment than in the Hot/Dry environment from 30 to 50 min and from 60 to 75 min (p<0.01). The differences in CON were mainly caused by the responses of Tskin on the thigh and lower leg (Supplementary Fig. 1). In EVA, the mean Tskin was lower in the Hot/Dry than in the Warm/Humid environment from 20 to 55 min (p<0.01) and conversely lower in the Warm/Humid environment than in the Hot/Dry environment from 85 to 110 min (p<0.01). The Tskin on the chest, back, abdomen, upper arm, and forearm showed similar responses to the mean Tskin (Supplementary Fig. 1). HR was lower in the EVA trials than in the CON trials (Fig. 1C, 35–110 min, p<0.05) in both the Hot/Dry (peak: 119 ± 20 vs. 138 ± 15 beats/min; p<0.05) and Warm/Humid (peak: 123 ± 14 vs. 145 ± 16 beats/min; p<0.05) environments.
Whole-body sweat loss in both environments was greater in the CON trial than in the EVA trials (Table 1; both p<0.001). The total volume of water ingested during the three break periods was greater in the Warm/Humid environment than in Hot/Dry environment in the CON trial (Table 1; p<0.05). No differences were observed between the environments in the EVA trial. At each break (B1–3), the volume did not differ between trials and environments. Body mass loss was lower in the EVA than in the CON trials in both Hot/Dry (p<0.001) and Warm/Humid (p<0.05) environments, without differences between the environments (Table 1). Regional SR was lower in the EVA trials than in the CON trials in both environments of the chest, back, forearm, and thigh (all p<0.05, Supplementary Fig. 3). Changes in the CVC on the chest, back, and forearm were also lower in the EVA trials than in the CON trials in both environments (all p<0.01, Supplementary Fig. 4).
Table 1. Whole-body sweat loss, total volume of water ingested, body mass loss, moisture content of the t-shirts and the other clothing at the end in Hot/Dry (40°C, 30% RH) and Warm/Humid (32°C, 80% RH) environments of the control (CON, wearing a dry inner t-shirt without ventilation garment fanning) and evaporative cooling (EVA, wearing a wetted inner t-shirt with ventilation garments fanning) trials.
| Hot/Dry |
Warm/Humid |
|||
|---|---|---|---|---|
| CON | EVA | CON | EVA | |
| Whole-body sweat loss (kg) | 1.08 ± 0.23 | 0.56 ± 0.12* | 1.12 ± 0.21 | 0.47 ± 0.10* |
| Total volume of water ingested (ml) | 512 ± 79 | 506 ± 196 | 802 ± 261# | 525 ± 146 |
| Body mass loss (kg) | 0.57 ± 0.21 | 0.06 ± 0.26* | 0.32 ± 0.20 | 0.04 ± 0.34* |
| Moisture content of the t-shirts at the end (g) | 156 ± 82 | 24 ± 11* | 242 ± 51 | 173 ± 47*# |
| Moisture content of the other clothings at the end (g) | 28 ± 24 | 0 ± 0* | 87 ± 38# | 53 ± 22*# |
Values are means ± standard deviation. *Different (p<0.05) from CON; #Different (p<0.05) from Hot/Dry. CON: control; EVA: evaporative cooling.
Perceptual responses
The thermal sensation rating in the EVA trials of both environments decreased at Ta of 25°C (50% RH) immediately after soaking the inner t-shirt and fanning at 10 min (Fig. 2A, p<0.05). After setting in each environment, the thermal sensation in the EVA remained decreased only in the Hot/Dry environment at 20 min (p<0.05), and was lower than that in the Warm/Humid environment (p<0.05). In the CON trials, the thermal sensation increased at 20 min in both environments (both p<0.05) and remained increased until 110 min. Although the thermal sensation in EVA also increased from 40 to 110 min, the rating score was lower in EVA than in CON throughout the experiment in both environments (both p<0.05). The thermal comfort rating decreased (i.e., discomfort increased) in the CON (20–110 min, all p<0.05) and EVA trials (40–110 min, all p<0.05) in both environments (Fig. 2B). The decrease in CON was greater than that in EVA in the Warm/Humid (20–110 min, all p<0.05) and Hot/Dry (40–110 min, all p<0.05) environments. The thirst sensation rating (Fig. 2C) increased at 40, 70, and 100 min (all p<0.05) and the fatigue rating (Fig. 2D) increased from 40 to 110 min in both trials in both environments (all p<0.05).
Clothing variables
Tcmc in the Hot/Dry environment was lower in the EVA trial than in the CON trial from 15 to 50 min (Fig. 3A, p<0.05) but was greater in the EVA trial than in the CON trial from 85 to 110 min (p<0.05). In the Warm/Humid environment, Tcmc was continually lower in the EVA trial than in the CON trial (Fig. 3A, 15–110 min, p<0.05). The RHcmc in the Hot/Dry environment was lower in the EVA trial than that in the CON trial (Fig. 3B, 30–110 min, p<0.05). In the Warm/Humid environment, the RHcmc increased more in EVA than in CON at 10 min (Fig. 3B, p<0.05), and the increase was greater in CON than in EVA from 40 to 110 min (p<0.05). The skin wettedness of the upper body in the EVA trials increased immediately after soaking the inner t-shirt (Fig. 3C, p<0.001). Although the increase in the Warm/Humid environment was maintained until the end of the experiment, skin wettedness gradually decreased to the baseline in the Hot/Dry environment. In CON, skin wettedness of the upper body gradually increased in both environments and remained elevated until the end (both p<0.05).
The moisture content of the t-shirts at the end of the experiment was greater in the CON trials than in the EVA trials (Table 1, both p<0.001) in both environments, with values being greater in the Warm/Humid than in the Hot/Dry environments (p<0.01). The moisture content of other clothing (jackets, pants, undershorts, and socks) at the end of the experiment was also greater in the CON trials than in the EVA trials (Table 1, both p<0.001) in both environments, with values being greater in the Warm/Humid than in the Hot/Dry environments (p<0.01).
Partitional calorimetry
Evaporative and dry heat losses in the EVA trials increased at rest before exercise (Fig. 4A and 4B, both p<0.05) and were greater in the Hot/Dry environment than in the Warm/Humid environment (both p<0.05). During exercise, the increase in evaporative heat loss was lower in the Hot/Dry environment than that in the Warm/Humid environment (Fig. 4A, p<0.05). Dry heat losses in the Hot/Dry environments showed negative values (heat gain) and were lower in the EVA trial than in the CON trial (Fig. 4B, p<0.05). In the Warm/Humid environment, the dry heat loss was greater in EVA than in CON (p<0.05). The estimated rate of body heat storage at rest before exercise decreased negatively with EVA (Fig. 4C, p<0.05). The increase during exercise was lower in EVA than in CON (both p<0.05) and lower in the Warm/Humid environment (p<0.05). Heat production during exercise increased gradually during the three walking periods in both trials and in both environments (Supplementary Fig. 2, all p<0.05). In Ex3, heat production was lower in the EVA trials than that in the CON trials in both environments (p<0.05).
Fig. 4.
Evaporative heat loss (A), dry heat loss (B), and heat storage (C) in the Hot/Dry (40°C, 30% RH) or Warm/Humid (32°C, 80% RH) environments and in the control (CON, wearing a dry inner t-shirt without ventilation garment fanning) and evaporative cooling (EVA, wearing a wetted inner t-shirt with ventilation garments fanning) trials.
“Base” represents the baseline measurements immediately before at 0 min; Rest from 0 to 20 min; Ex1 from 25 to 40 min; Ex2 from 55 to 70 min; Ex3 from 85 to 100 min. *Significant difference for CON vs. EVA trial in Hot/Dry environment, p<0.05. #Significant difference for CON vs. EVA trial in Warm/Humid environment, p<0.05. §Significant difference for Hot/Dry vs. Warm/Humid condition in the CON trial, p<0.05. †Significant difference for Hot/Dry vs. Warm/Humid environment in the EVA trial, p<0.05. Data are expressed as the mean ± SD for eight participants. CON: control; EVA: evaporative cooling.
Discussion
The present study aimed to evaluate the effectiveness of evaporative cooling by combining wet inner clothing with the fanning of ventilation garments in Hot/Dry (40°C, 30% RH) and Warm/Humid (32°C, 80% RH) environments (both WBGT 31.5°C) during moderate-intensity exercise while wearing work clothing. In both environments, EVA attenuated the increases in Trec, HR, sweat loss, thermal sensation, and thermal discomfort compared with CON, which involved dry inner clothing and no fanning of ventilation garments. Combining these findings with Tokizawa4) at equivalent WBGT (37°C, 50% RH), EVA reduces physiological and perceptual heat strain when ≤ WBGT 31.5°C regardless of the conditions in which Ta exceeds Tskin or the humidity level is high.
In CON, there was no significant difference between the two environments in Trec, HR, and perceptual responses, whereas the mean Tskin was greater in the Hot/Dry environment than in the Warm/Humid environment (Fig. 1B). This is consistent with previous studies conducted by comparing between Hot/Dry and Warm/Humid environments at equivalent WBGT of 28°C14), 29°C15), and 32°C16). Compared to the control conditions at equivalent WBGT of 31.5°C (37°C, 50% RH) in Tokizawa4), the responses in Trec, HR, and sweat loss were similar to those in CON of the Hot/Dry and Warm/Humid environments, whereas mean Tskin was greater than in the Warm/Humid environment (36.5 ± 0.5 vs. 36.0 ± 0.4°C) and similar to that in the Hot/Dry environment. Although high Ta increased Tskin mainly in the legs (Supplementary Fig. 1), the fundamental thermoregulatory responses did not differ among the three environments.
Evaporative heat loss varies according to the skin (shirt)-air vapor pressure gradient, skin (shirt) wettedness, evaporative heat transfer coefficient, and air velocity10, 17). The latter two factors were similar in both environments. At rest, skin wettedness of the upper body in the EVA trials increased in the same manner in both environments (Fig. 3C). Thus, the difference in air vapor pressure between the Hot/Dry (2.2 kPa) and Warm/Humid (3.8 kPa) environments was likely to widen the skin-air vapor pressure gradient, and evaporative heat loss facilitated more in the Hot/Dry environment at rest (Fig. 4A). The accelerated heat dissipation would then decrease the mean Tskin more in the Hot/Dry than in the Warm/Humid environment (Ex1, Fig. 1B) with lower thermal sensation at 20 min in the Hot/Dry than in the Warm/Humid environment (Fig. 2A). As the water content of the inner t-shirt dried faster in the Hot/Dry environment according to the skin wettedness of the upper body (Fig. 3C), the evaporative heat loss lessened in Ex2 and Ex3 (Fig. 4A). Eventually, the total evaporative heat loss was greater in the Hot/Dry than in the Warm/Humid environment (Hot/Dry 522 ± 22 W/m2, Warm/Humid 486 ± 26 W/m2, p<0.05) with greater total heat storage (Hot/Dry 164 ± 45 W/m2, Warm/Humid 99 ± 37 W/m2, p<0.05). However, if the protocols had lasted longer than two hours without additional water soaking in the EVA trials, heat strain may have been greater in the Hot/Dry than in the Warm/Humid environment.
Contrary to the hypothesis, neither the Hot/Dry and Warm/Humid environments negated the effectiveness of evaporative cooling. The reasons for the seemingly modulated cooling effects in both environments are not inherently clear. However, we speculate that they may be consequences of the greater convective heat gain of high Ta in the Hot/Dry environment and the lower evaporative heat loss of high humidity in the Warm/Humid environment. In the Hot/Dry environment, Tcmc in the EVA trial surpassed that of the CON trial from 80 to 110 min (38.7 ± 0.2 vs. 37.0 ± 0.5°C; Fig. 3A), while Tcmc in the Warm/Humid environment remained continuously lower in the EVA trial than in the CON trial (31.5 ± 0.3 vs. 33.8 ± 0.4°C; Fig. 3A). In the Warm/Humid environment, almost half of the soaked 350 ml of water remained in the t-shirts at the end of the experiment (Table 1). In 37°C/50% RH of the same protocol4), Tcmc in EVA did not surpass that of CON. The residual water was greater in the Warm/Humid than in the Hot/Dry and in 37°C/50%RH of the same protocol (58 ± 29 g)4) even with similar sweat volume. The higher air vapor pressure of the Warm/Humid environment (3.8 kPa) compared to the 37°C/50%RH environment (3.1 kPa) would inhibit evaporative heat loss and reduced cooling effects. Effect sizes (Hedge’s g) of responses in Trec were smaller in Hot/Dry (g=0.79) and Warm/Humid (g=0.92) environments than in 37°C/50%RH (g=1.96)4).
From a practical perspective, the use of ventilation garments would be restricted in certain workplaces; for example, where there is a risk of contamination or hazardous substances, wearing ventilation garments is not practical. Contamination caused by dust or soil can be prevented by attaching a specific filter to the fan. Although a field study showed the applicability of ventilation garments in the agriculture industry18), further research is needed to determine their potential use in other industries. Among various personal cooling garments, the hybrid method of convective and evaporative cooling4) is classified as having moderate effectiveness19). Tetzlaff et al.19) reported that conductive cooling provides the most consistent benefit in reducing heat strain. Wearing cooling vests containing ice, gel or phase-change material facilitates conductive heat loss; however, they inevitably cause ergonomic problems, such as additional weight and restricted body movement. Wearing ventilation garments and wet clothing would not cause similar problems, but it may be necessary to combine with conductive methods to achieve effectiveness.
It is important to highlight the limitations of this study. First, the present findings are specific to the environments employed (40°C/30% RH and 32°C/80% RH); thus, we could not determine the critical environmental limits for evaporative cooling. Foster et al.20) showed the critical environmental limits for electric fan use during work in hot conditions, in which a wide range evaluation of Ta (30–50°C) and RH (0–100%) combination revealed the matrix representing “effective”, “minimal effect”, or “harmful (do not use)” of electric fan in corresponding heat environments. As the efficiency of ventilation garments can differ from that of electric fans, future studies should evaluate the critical environmental limits for ventilation garment use. Second, the study population comprised only young male participants. The confounding effects of age and sex may be relevant, although both older and female participants, when healthy, respond similarly to heat exposure as their counterparts, as long as their fitness levels and, to a lesser extent, their anthropometrics are considered21, 22). Third, the control condition in the present study involved a use of the ventilation jacket without a fan as standard work clothing. Although the jacket’s clothing insulation was relatively low (0.21 clo, single layer 100% cotton), wearing it can limit heat dissipation from the torso and arms under hot conditions. A test without the jacket (i.e., wearing only a t-shirt) should have been evaluated. Finally, it should be noted that the present findings are limited to laboratory settings and do not include sun exposure or natural wind flow. Because those factors could affect heat strain during exercise with variance of air temperature and RH23), future research should consider investigating whether strategies to supplement sweat production and ventilation garments can effectively mitigate heat strain in occupational fields.
Thus, in both Hot/Dry and Warm/Humid environments, wearing a water-soaked inner t-shirt combined with ventilation garments during moderate-intensity exercise mitigated increases in core temperature, heart rate, whole-body sweat loss, and thermal perceptions.
Funding
This research was supported financially by the project research of National Institute of Occupational Safety and Health, Japan.
Conflict of Interest
No conflicts of interest, financial or otherwise, are declared by the author.
Supplementary
Acknowledgments
We thank all participants who volunteered for the experiment. We also thank Yuko Kasai for assistance with data collection and Makoto Fukuda and Yasuho Takii (ASICS Institute of Sport Science, Kobe, Japan) for technical assistance.
References
- 1.Song W, Wang F, Zhang C. (2019) Intermittent wetting clothing as a cooling strategy for body heat strain alleviation of vulnerable populations during a severe heatwave incident. J Therm Biol 79, 33–41. [DOI] [PubMed] [Google Scholar]
- 2.Morris NB, Gruss F, Lempert S, English T, Hospers L, Capon A, Jay O. (2019) A preliminary study of the effect of dousing and foot immersion on cardiovascular and thermal responses to extreme heat. JAMA 322, 1411–3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Cramer MN, Huang M, Moralez G, Crandall CG. (2020) Keeping older individuals cool in hot and moderately humid conditions: wetted clothing with and without an electric fan. J Appl Physiol 128, 604–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Tokizawa K. (2023) Effects of wetted inner clothing on thermal strain in young and older males while wearing ventilation garments. Front Physiol 14, 1122504. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Adams WC, Mack GW, Langhans GW, Nadel ER. (1992) Effects of varied air velocity on sweating and evaporative rates during exercise. J Appl Physiol 73, 2668–74. [DOI] [PubMed] [Google Scholar]
- 6.Yang J, Wang F, Song G, Li R, Raj U. (2022) Effects of clothing size and air ventilation rate on cooling performance of air ventilation clothing in a warm condition. Int J Occup Saf Ergon 28, 354–63. [DOI] [PubMed] [Google Scholar]
- 7.MacRae BA, Annaheim S, Stämpfli R, Spengler CM, Rossi RM. (2018) Validity of contact skin temperature sensors under different environmental conditions with and without fabric coverage: characterisation and correction. Int J Biometeorol 62, 1861–72. [DOI] [PubMed] [Google Scholar]
- 8.Kato I, Masuda Y, Nagashima K. (2021) Surgical masks do not increase the risk of heat stroke during mild exercise in hot and humid environment. Ind Health 59, 325–33. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Ramanathan NL. (1964) A new weighting system for mean surface temperature of the human body. J Appl Physiol 19, 531–3. [DOI] [PubMed] [Google Scholar]
- 10.Gagge AP. (1937) A new physiological variable associated with sensible and insensible perspiration. Am J Physiol 120, 277–87. [Google Scholar]
- 11.Nakamura M, Yoda T, Crawshaw LI, Yasuhara S, Saito Y, Kasuga M, Nagashima K, Kanosue K. (2008) Regional differences in temperature sensation and thermal comfort in humans. J Appl Physiol 105, 1897–906. [DOI] [PubMed] [Google Scholar]
- 12.Faul F, Erdfelder E, Lang AG, Buchner A. (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39, 175–91. [DOI] [PubMed] [Google Scholar]
- 13.Cohen J. (1988) Statistical power analysis for the behavioural sciences, 2nd Ed. Lawrence Erlbaum, New Jersey. [Google Scholar]
- 14.Smolander J, Ilmarinen R, Korhonen O, Pyykkö I. (1987) Circulatory and thermal responses of men with different training status to prolonged physical work in dry and humid heat. Scand J Work Environ Health 13, 37–46. [DOI] [PubMed] [Google Scholar]
- 15.Wright HE, McLellan TM, Stapleton JM, Hardcastle SG, Kenny GP. (2012) Cortisol and interleukin-6 responses during intermittent exercise in two different hot environments with equivalent WBGT. J Occup Environ Hyg 9, 269–79. [DOI] [PubMed] [Google Scholar]
- 16.Kenney WL, Anderson RK. (1988) Responses of older and younger women to exercise in dry and humid heat without fluid replacement. Med Sci Sports Exerc 20, 155–60. [DOI] [PubMed] [Google Scholar]
- 17.Nelson N, Eichna LW, Horvath SM, Shelley WB, Hatch TF. (1947) Thermal exchanges of man at high temperatures. Am J Physiol 151, 626–52. [DOI] [PubMed] [Google Scholar]
- 18.Ioannou LG, Mantzios K, Tsoutsoubi L, Nintou E, Vliora M, Gkiata P, Dallas CN, Gkikas G, Agaliotis G, Sfakianakis K, Kapnia AK, Testa DJ, Amorim T, Dinas PC, Mayor TS, Gao C, Nybo L, Flouris AD. (2021) Occupational heat stress: multi-country observations and interventions. Int J Environ Res Public Health 18, 6303. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Tetzlaff EJ, Ioannou LG, O’Connor FK, Kaltsatou A, Ly V, Kenny GP. (2025) Practical considerations for using personal cooling garments for heat stress management in physically demanding occupations: a systematic review and meta-analysis using realist evaluation. Am J Ind Med 68, 3–25. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Foster J, Smallcombe JW, Hodder S, Jay O, Flouris AD, Havenith G. (2022) Quantifying the impact of heat on human physical work capacity; part II: the observed interaction of air velocity with temperature, humidity, sweat rate, and clothing is not captured by most heat stress indices. Int J Biometeorol 66, 507–20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Notley SR, Lamarche DT, Meade RD, Flouris AD, Kenny GP. (2019) Revisiting the influence of individual factors on heat exchange during exercise in dry heat using direct calorimetry. Exp Physiol 104, 1038–50. [DOI] [PubMed] [Google Scholar]
- 22.Cramer MN, Jay O. (2015) Explained variance in the thermoregulatory responses to exercise: the independent roles of biophysical and fitness/fatness-related factors. J Appl Physiol 119, 982–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Foster J, Smallcombe JW, Hodder S, Jay O, Flouris AD, Nybo L, Havenith G. (2022) Quantifying the impact of heat on human physical work capacity; part III: the impact of solar radiation varies with air temperature, humidity, and clothing coverage. Int J Biometeorol 66, 175–88. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.




