Fig. 4.
DRB results. (A) The bit-flip and phase-flip errors of resonant- and detuned-KCQ, and corresponding estimation and based on the bit-flip and phase-flip times measured in Fig. 2. The error bars are smaller than the marker size and therefore not plotted. (B) The noise bias as a function of phase-flip errors.