Skip to main content
. 2026 Jan 21;13:1679203. doi: 10.3389/fmed.2026.1679203

TABLE 4.

Statistical significance of model performance differences across elastography modalities based on the DeLong Test.

Elastography Model 1 Model 2 P-value
Shear-wave DenseNet-121 GoogleNet 0.008
DenseNet-121 ResNet-50 0.045
DenseNet-121 EfficientNet-B6 0.030
GoogleNet ResNet-50 0.650
GoogleNet EfficientNet-B6 0.420
ResNet-50 EfficientNet-B6 0.580
Strain GoogleNet DenseNet-121 < 0.001
GoogleNet ResNet-50 < 0.001
GoogleNet EfficientNet-B6 < 0.001
DenseNet-121 ResNet-50 0.320
DenseNet-121 EfficientNet-B6 0.150
ResNet-50 EfficientNet-B6 0.220
Doppler GoogleNet DenseNet-121 0.010
GoogleNet ResNet-50 < 0.001
GoogleNet EfficientNet-B6 < 0.001
DenseNet-121 ResNet-50 0.120
DenseNet-121 EfficientNet-B6 0.050
ResNet-50 EfficientNet-B6 0.480