Skip to main content
. 2026 Feb 1;82(Pt 1):2–13. doi: 10.1107/S2052520625010893

Table 2. Results of the chemical investigations of the starting materials performed by ICP-OES and µ-XRF in p.p.m. by weight.

The results of the latter technique are shown in parentheses. Some of the ICP-OES values are below the limit of quantification (LOQ).

Sample Al Ca Ti V Cr Mn Fe Zn
Arc-fusion grown material for initial feeds and seeds 81 ± 0.8 (313 ± 66) < 4.8 (14 ± 3) 36 ± 0.43 (25 ± 1) 28 ± 0.67 (72 ± 18) 13 ± 0.16 (4 ± 2) 76 ± 0.88 (72 ± 2) < 4.2 (0–15)
MgO ceramic target sample as delivered (manufactured by Kojundo, theoretical purity given by the manufacturer: 99.995%) < 10.8 (29 ± 1) < 4.8 < 9.3 < 12.3 8 ± 0.07 8 ± 0.35 11 ± 0.1
5N (99.999%) MgO powder as delivered by Roth (Rotimetic) < 3.1–16 < 0.07–0.8 < 0.8 < 2 < 1 < 0.3 < 1.9 < 0.8