Abstract
Background:
Polyethylene bearing (PEB) thickness in total knee arthroplasty (TKA) is a critical factor in achieving joint stability and soft-tissue balance. Despite long-standing surgical preference for thinner bearings, the effect of thicker PEBs on patient-reported outcomes (PROs) remains unclear. The purpose of this study was to compare patient-reported and surgical outcomes between patients receiving thicker (≥13 mm) and thinner (<13 mm) PEBs in primary TKA.
Methods:
We retrospectively analyzed 2,751 patients who underwent primary TKA for osteoarthritis at a single high-volume orthopaedic hospital between 2020 and 2023. Patients were divided into two groups based on PEB thickness. Outcomes included PROs (Knee Injury and Osteoarthritis Outcome Score for Joint Replacement; Forgotten Joint Score), inpatient pain and mobility, surgical data, and 90-day postoperative complications. Multivariate statistical methods were used for analysis.
Results:
PEB thickness was not associated with clinically notable differences in PROs. At 6 and 12 months, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement and pain scores were slightly better in the ≥13-mm group (P < 0.05), but differences were not clinically meaningful. Subgroup analysis showed these differences were notable only in male patients. Forgotten Joint Scores and early complication rates were equivalent between groups.
Discussion:
The use of thicker PEBs (≥13 mm) in TKA does not negatively affect PROs or early surgical outcomes and may slightly improve midterm pain and function in male patients. These findings support the selective use of thicker bearings when required for intraoperative balance without compromising patient satisfaction or recovery.
Total knee arthroplasty (TKA) is one of the most common orthopaedic surgical procedures with at least 1 million cases done in 2023 and an estimated 3.5 million cases annually by 2030.1,2 One of the key components of TKA implants is the polyethylene bearing (PEB), which serves at the surface between the femoral and tibial implants. Varying the thickness of the PEB allows surgeons to optimize joint stability and ligament balance during the procedure. Modern PEB designs can also be used to drive joint kinematics, although this assumes the correct thickness has been selected to recreate the native joint line.3,4 The thickness of the PEB is ultimately related to the depth of the tibial cut, alignment correction, and ligamentous laxity. Several of these factors are patient dependent, and not under the surgeon's control. Despite this, a thin bearing is still considered to be ideal.4,5 The definition of “thick” or “thin” is variable in the literature with some studies selecting 13 mm and others 16 mm as the cutoff between groups.5-7
Multiple studies have asserted that there are no differences in outcomes between thick and thin PEBs, with comparable rates of revision surgery, rates of surgical complications, adverse functional outcomes, radiographic changes, and implant survival.5,8,9 Increased thickness of the bearing has also shown to increase stability at the expense of range of motion, primarily affecting the patient's ability to extend the knee, which can affect the patient perception of surgical success.10 However, many groups have found an association between the use of thicker PEBs and adverse surgical outcomes. A higher likelihood of revision surgery and an increase in the rate of aseptic loosening with the use of thicker PEBs was consistent across multiple studies, whereas the effect of using a thicker PEB on all-cause failures or clinical outcomes varied between groups.6,11,12 Failure has been hypothesized to be not from the thicker bearing directly, but from unforeseen surgical factors that give rise to the insertion of a thicker bearing. These factors include intended or unintended deep tibial resection, ligament damage or disruption, and imbalanced gaps.13 Overall, the available literature presents a mixed picture as to TKA outcome when using a thicker PEB, with few studies reporting on patient-reported outcomes (PROs).
The purpose of this study was to examine PROs between patients who received a thicker PEB (≥13 mm) and those who received a thinner PEB (<13 mm). Surgical outcomes, early-term complications, and readmissions within 90 days from the index procedure were also assessed. We hypothesized that there would be no difference in patient-reported or surgical outcomes between the groups. Understanding how the thickness of the PEB affects patient outcomes will help clinicians strengthen their decision making intraoperatively during TKA.
Methods
Patients aged 18 to 89 years, who underwent a TKA for primary osteoarthritis between March 1, 2020, and December 31, 2023, at a high-volume, urban, orthopaedic specialty hospital, were assessed retrospectively. Approval for this study was obtained from our institutional review board (HHC-2024-0233). Patients on long-term opiates were excluded because of higher pain scores, morphine milligram equivalent (MMEs) requirements, and lower overall outcome scores. Patients were also excluded if they did not complete preoperative PROs or if the size of the PEB was not listed in the surgical notes. In addition, patients who underwent a robotic-assisted TKA were excluded, as were those who had noncemented fixations, as the authors have found those populations to be predominately younger and their starting PROs are poor. All patients were followed for at least 1 year.
There were initially 4,726 patients in the TKA cohort. Patients who did not complete their preoperative PROs were eliminated, reducing the cohort to 3,185. Subsequently, 312 patients who had a robotic TKA were eliminated as were 122 noncemented TKAs, as these populations tend to have different PROs in our patient cohorts. This reduced our total patient population to 2,751. Of these patients, 2,456 had a PEB size listed as less than 13 mm and 295 patients where the PEB size was 13 mm or greater. The PEBs were evenly distributed between posterior stabilized (PS, 32.7%), cruciate retaining (CR, 33.8%), and medial congruent (MC, 33.5%). Zimmer (Zimmer Biomet) implants were used for 76.7% of the TKAs done and Smith & Nephew (Smith & Nephew) were used for the remaining 23.3%. The two cohorts of patients were reasonably well matched in terms of age, race, ethnicity, body mass index (BMI), and clinical comorbidities, as seen in Table 1. Implant brands were initially analyzed separately, but found to be equivalent and subsequently analyzed as a group. All surgeries were done by eight fellowship trained, high-volume orthopaedic surgeons. A medial parapatellar approach was used for all surgeries, all of which used a mechanical alignment and measured resection strategy. Tourniquet use was at surgeon discretion. For all patients undergoing a TKA at our institution, regional nerve blocks and spinal anesthesia were used, and tranexamic acid, 1 g, was dosed intravenously. All patients were medically optimized before surgery and were mobilized on postoperative day zero, with a goal of rapid recovery and discharge within 23 hours. An identical multimodal pain management was provided to all patients, and low-dose aspirin was given for the prophylaxis of deep vein thrombosis, unless contraindicated.
Table 1.
Demographics for Both Polyethylene Bearing Thicknesses
| Demographics | TKA PEB <13 mm n = 2,456 |
TKA PEB ≥13 mm n = 295 |
P | ||
| Female sex | 69.3% | 1,701 | 52.7% | 155 | <0.001 |
| Age (yr) | 70.7 ± 8.2 | 69.8 ± 8.3 | 0.063 | ||
| Race | 0.169 | ||||
| Black or African American | 4.9% | 120 | 7.5% | 22 | |
| Multiracial/other | 6.6% | 161 | 6.4% | 19 | |
| White or Caucasian | 88.5% | 2,175 | 86.1% | 254 | |
| Ethnicity | 0.571 | ||||
| Hispanic or Latino | 3.5% | 85 | 3.7% | 11 | |
| Not Hispanic or Latino | 95.4% | 2,344 | 95.6% | 282 | |
| Unknown/patient refused | 1.1% | 28 | 0.7% | 2 | |
| BMI overall (kg/m2) | 32.5 ± 6.1 | 32.9 ± 5.8 | 0.301 | ||
| Female | 32.8 ± 6.3 | 33.4 ± 6.2 | |||
| Male | 31.9 ± 5.6 | 32.4 ± 5.2 | |||
| Comorbidities | |||||
| RAPT score | 8.9 ± 2.0 | 9.1 ± 2.1 | 0.190 | ||
| CCI score | 3.8 ± 1.9 | 3.7 ± 1.9 | 0.188 | ||
| Laterality | 48.1% left | 1,181 | 48.1% left | 142 | 0.987 |
| Length of stay (d) | 1.1 ± 0.6 | 1.1 ± 0.5 | 0.563 | ||
| Surgical time (min) | 82.6 ± 12.9 | 86.1 ± 15.1 | <0.001 | ||
| PACU time (min) | 87.7 ± 32.7 | 87.3 ± 28.9 | 0.844 | ||
| Use of tourniquet | 83.7% | 2,293 | 80.9% | 259 | 0.001 |
| Use of navigation | 6.1% | 149 | 5.1% | 15 | 0.501 |
BMI = body mass index, PACU = postoperative acute care unit, PEB = polyethylene bearing, TKA = total knee arthroplasty, RAPT = Risk Asssessment and Prediction Tool, CCI = Charlson Comorbidity Index
Bolded values are statistically significant, data are presented as means and SDs or as percentage of the cohort.
Both PROs and clinical outcomes, such as surgical time and length of stay, were assessed. Data were also collected on 90-day complications, including revision surgeries, return to the emergency department, and all-cause readmissions. Inpatient MMEs and physical therapy assessments were collected. Pain scores were collected both inpatient, and at 3 months, 6 months, and 1 year after the index procedure. The Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) was collected preoperatively and at 3 months, 6 months, and 1 year. Forgotten Joint Scores (FJS) were collected at 1 year. All PROs were collected using the FORCE Therapeutics patient engagement platform (FORCE Therapeutics). The minimal clinically important difference was calculated for the KOOS, JR, and FJS at the 1-year time point, per Lyman et al14 and Singh et al.15
Chi square or Fisher exact tests were used to compare single outcome measures. Student t-tests or Kruskal-Wallis tests were used for continuous variables, depending on the underlying distribution of the variable. Logistic regression was used to determine whether there were any confounders between the two groups. Multivariate probit regression, with PS as the base outcome, was used to compare outcomes between each polyethylene type. Statistical significance was defined as a P-value <0.05. STATA (Version 17; STATACorp), and Microsoft Excel 2016 (Microsoft) were used to analyze the data sets.
Results
Although the two cohorts were similar in terms of demographics, there were more women in the < 13-mm group, at 69.3%, compared with 52.7% in the ≥ 13-mm group. A similar percentage of patients in both groups had the surgery done with navigation (6.1% versus 5.1%, P = 0.501), as this was the propensity of two surgeons within the groups. The length of stay was very similar between the groups as well, as was time spent in the postoperative acute care unit. Patients who had a PEB ≥13-mm had a statistically significantly longer mean operative time (86.1 versus 82.6 minutes, P < 0.001). Tourniquets were also less likely to be used in the PEB ≥13-mm group (80.9% versus 83.7%, P < 0.001) (Table 1).
There were no differences in pain scores at rest or with activity in between the two PEB groups, nor was there a notable difference in the MMEs dosed over the hospital stay, as seen in Table 2. Inpatient physical therapy assessments were also equivalent between both groups. Preoperative KOOS, JR scores were equivalent between both groups, but by 6 months after surgery, there was a notable difference between the PEB groups. Patients with a PEB ≥ 13-mm reported higher mean KOOS, JR scores at the 6-month (73.4 versus 76.0 pts, P = 0.005) and 1-year (76.1 versus 78.4 points, P = 0.014) time points. In addition, the PEB ≥ 13-mm group also had better postsurgical mean pain scores at 6 months (1.7 versus 2.1 points, P = 0.012), and their pain scores trended lower at 1 year as well (1.7 versus 2.1, P = 0.061).
Table 2.
Outcomes for Both Polyethylene Bearing Thicknesses
| Outcomes | TKA Poly < 13 mm n = 2,456 |
TKA Poly ≥ 13 mm n = 295 |
P | ||
| In patient pain scores | |||||
| At rest | 2.9 ± 1.5 | 2.9 ± 1.4 | 0.617 | ||
| With activity | 4.4 ± 1.6 | 4.3 ± 1.6 | 0.724 | ||
| Inpatient morphine milligram equivalents | 69.1 ± 54.6 | 73.9 ± 74.9 | 0.298 | ||
| Inpatient PT parameters | |||||
| Maximum Ambulation distance | 185.6 ± 178.7 | 188.1 ± 89.7 | 0.692 | ||
| Timed up and go (TUG) score | 26.0 ± 16.4 | 25.8 ± 12.9 | 0.850 | ||
| Maximum 30-s sit to stand | 8.4 ± 3.6 | 8.4 ± 3.1 | 0.982 | ||
| KOOS, JR scores | |||||
| Preoperative | 52.1 ± 13.1 | 52.4 ± 14.7 | 0.711 | ||
| 12 wk postoperative | 68.4 ± 11.5 | 69.9 ± 12.4 | 0.084 | ||
| 6 mo postoperative | 73.4 ± 13.2 | 76.0 ± 12.5 | 0.005 | ||
| 1 yr postoperative | 76.1 ± 14.0 | 78.4 ± 13.9 | 0.014 | ||
| Met MCID (15 pt) | 68.6% | 1,232 | 70.0% | 161 | 0.666 |
| Forgotten joint score at 1 yr | 54.4 ± 26.6 | 55.8 ± 26.3 | 0.535 | ||
| Postsurgical pain scores | |||||
| 12 wk postoperative | 2.5 ± 1.8 | 2.2 ± 1.9 | 0.116 | ||
| 6 mo postoperative | 2.1 ± 1.9 | 1.7 ± 1.8 | 0.012 | ||
| 1 yr postoperative | 2.1 ± 2.0 | 1.7 ± 2.0 | 0.061 | ||
| Return to ED within 90 d | 8.39% | 206 | 8.14% | 24 | 0.882 |
| Readmission within 90 d | 4.32% | 106 | 4.75% | 14 | 0.733 |
| Return to the OR within 90 d | 1.02% | 25 | 0.68% | 2 | 0.576 |
ED = emergency department, KOOS, JR = Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, MCID = minimal clinically important difference, OR = operating room, TKA = total knee arthroplasty
Bolded values are statistically significant, and data are presented as means and SDs or as percentage of the cohort.
Logistic regression indicated that the differences in postoperative outcomes and postsurgical pain were predominately driven by patient sex. Further analysis, shown in Table 3, shows that this is exclusive to male patients. Female patients in both the PEB <13-mm and the PEB ≥13-mm groups have very similar KOOS, JR scores and postsurgical pain scores at any time point. For male patients, differences are seen in KOOS, JR scores at 12 weeks, with the PEB ≥13-mm group outperforming the PEB <13-mm (P = 0.046). This continues to be seen at 6 months (P = 0.004), and the trend is still strong at 1 year, although no longer statistically significant (P = 0.056). Postsurgical pain was significantly higher in the PEB <13-mm group at 6 months (P = 0.005) and 1 year (P = 0.026). FJSs in the two PEB groups were not different for either male patients or female patients.
Table 3.
Knee Injury and Osteoarthritis Outcome Score for Joint Replacement and Pain Scores Subdivided by Sex and Polyethylene Bearing Thickness
| Factors | Outcomes by Sex | TKA PEB < 13 mm ♂ = 754, ♀ = 1,701 |
TKA PEB ≥ 13 mm ♂ = 139, ♀ = 155 |
P |
| Men | KOOS, JR scores | |||
| Preoperative | 53.6 ± 12.8 | 53.8 ± 14.8 | 0.926 | |
| 12 wk postoperative | 68.1 ± 11.1 | 70.6 ± 11.9 | 0.046 | |
| 6 mo postoperative | 73.3 ± 12.5 | 77.3 ± 12.3 | 0.004 | |
| 1 yr postoperative | 75.7 ± 13.8 | 78.4 ± 13.1 | 0.056 | |
| Postsurgical pain scores | ||||
| Preoperative | 6.7 ± 4.9 | 7.5 ± 4.6 | 0.706 | |
| 12 wk postoperative | 2.3 ± 1.7 | 2.1 ± 2.0 | 0.638 | |
| 6 mo postoperative | 2.0 ± 1.8 | 1.3 ± 1.6 | 0.005 | |
| 1 yr postoperative | 2.0 ± 2.0 | 1.5 ± 1.8 | 0.026 | |
| Women | KOOS, JR scores | |||
| Preoperative | 51.4 ± 13.2 | 51.4 ± 14.7 | 0.981 | |
| 12 wk postoperative | 68.5 ± 11.7 | 69.4 ± 12.4 | 0.460 | |
| 6 mo postoperative | 73.4 ± 13.5 | 75.0 ± 12.5 | 0.181 | |
| 1 yr postoperative | 76.2 ± 14.0 | 78.7 ± 13.9 | 0.073 | |
| Postsurgical pain scores | ||||
| Preoperative | 7.7 ± 4.2 | 6.7 ± 5.2 | 0.652 | |
| 12 wk postoperative | 2.5 ± 1.8 | 2.3 ± 1.9 | 0.169 | |
| 6 mo postoperative | 2.1 ± 2.0 | 1.9 ± 2.0 | 0.359 | |
| 1 yr postoperative | 2.1 ± 2.1 | 1.9 ± 2.0 | 0.362 |
♂: Male ♀: Female, Bolded values are statistically significant, and data are presented as means and SDs or as percentage of the cohort. PEB = polyethylene bearing, TKA = total knee arthroplasty, KOOS, JR = Knee Injury and Osteoarthritis Outcome Score for Joint Replacement
Multinomial probit regression, using a PS PEB as the control, showed no difference in KOOS, JR scores or postoperative pain scores at 6 months or 1 year based on PEB type, as seen in Table 4. This was consistent for both men and women. Raw KOOS, JR scores, sorted by bearing thickness, are seen in Figure 1, and are consistent across PEB type.
Table 4.
Multivariate Probit Regression P values, With Posterior Stabilized Knees as the Base Outcome
| Factors | Outcomes by Poly Type | n | KOOS, JR Scores (Mean ± SD) | P TKA PEB <13 mm | P TKA PEB ≥13 mm |
| PS | KOOS, JR scores | Base outcome | Base outcome | ||
| Preoperative | 846 | 52.3 ± 12.9 | |||
| 12 wk postoperative | 674 | 68.9 ± 12.2 | |||
| 6 mo postoperative | 618 | 73.9 ± 14.1 | |||
| 1 yr postoperative | 641 | 76.1 ± 14.5 | |||
| CR | KOOS,JR scores | ||||
| Preoperative | 876 | 53.1 ± 13.6 | 0.041 | 0.438 | |
| 12 wk postoperative | 703 | 68.2 ± 11.3 | 0.101 | 0.456 | |
| 6 mo postoperative | 619 | 73.1 ± 12.2 | 0.188 | 0.510 | |
| 1 yr postoperative | 656 | 76.4 ± 13.6 | 0.266 | 0.614 | |
| MC | KOOS, JR scores | ||||
| Preoperative | 867 | 51.1 ± 13.7 | 0.206 | 0.904 | |
| 12 wk postoperative | 667 | 68.7 ± 11.3 | 0.472 | 0.575 | |
| 6 mo postoperative | 609 | 74.1 ± 12.9 | 0.975 | 0.666 | |
| 1 yr postoperative | 614 | 76.5 ± 13.7 | 0.416 | 0.961 |
CR = cruciate retaining, KOOS, JR = Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, MC = medial congruent, PEB = polyethylene bearing, PS = posterior stabilized, TKA = total knee arthroplasty
Figure 1.
Graph showing KOOS, JR scores subdivided by PEB thickness and by PEB type. Preoperative KOOS, JR scores are shown in blue, 3-month KOOS, JR scores are shown in red, 6-month KOOS, JR scores are shown in green, and 1-year KOOS, JR scores are shown in orange. No difference is seen in KOOS, JR scores for a PEB <13 mm compared with a PEB ≥13 mm. No differences are seen based on the type of PEB implanted, with PS, CR, and MC bearings having equivalent outcomes. CR = cruciate retaining, KOOS, JR = Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, MC = medial congruent, PEB = polyethylene bearing, PS = posterior stabilized
Neither group had an increase in early complications. There was no difference in the number of patients who returned to the emergency department, were readmitted, or returned to the operating room within 90 days (Table 2). However, there were a small number of complications overall. Patients in the PEB ≥13-mm group only had one manipulation under anesthesia and no incision and drainage for suspected infection. In the PEB <13-mm group, there were two polyethylene exchanges and 8 incision and drainages, as well as nine manipulations under anesthesia.
Discussion
In this study, we found that PEB thickness in primary TKA markedly correlated to PROs and postoperative pain up to 1 year. These differences, however, were likely not clinically significant.16 Although male patients did show statistically notable differences in pain at later time points, the question of the clinical relevance of this finding remains up for debate. A difference in KOOS, JR scores of four points, which is statistically significantly different, is likely not clinically relevant, nor is a difference in pain scores of 0.7 points. Female patients overall had a higher BMI than male patients in our cohorts, suggesting that BMI was not driving pain or KOOS, JR scores.
A thicker PEB does increase the forces on the ligaments throughout flexion and extension, with thicker PEBs increasing the load sharing through the femur and quadriceps tendon.17 This shift in forces does not appear to affect patient outcomes because there was no difference in inpatient physical therapy parameters, inpatient pain scores, and return to either the emergency department or operating room within 90 days after surgery. The FJS-12 was also comparable between groups. All PEB types, PS, CR, and MC, showed similar outcomes. This correlates with the results from recent studies on the topic.18
This study does have limitations. This was a retrospective review that required patients to complete their PROs for inclusions, which could have created a biased sample. Also, implant brand, PEB type and thickness were left to physician's choice, although approximately one-third of the implants were of each type (PS, CR, and MC). This means that unmeasured confounders, like gap balancing strategy or soft-tissue handling might play a role in outcomes. The surgeries were completed by eight different surgeons with a range of years of experience and different surgical techniques. In addition, postoperative range of motion and radiographic analysis were not collected for all patients. This study also only followed patients out to 1 year, whereas other studies follow patients out to 5 years to look at survivorship. The authors chose a shorter follow-up time to capture outcomes for MC PEB. Further research is needed to look at implant failure and revision rates based on PEB size, as well as FJS-12 and KOOS, JR. scores beyond 1 year postoperatively. Individual anatomy and preserved native bone for possible future revision surgery is another factor important to PEB size decisions.
In conclusion, these data suggest that PEB ≥13-mm in thickness remains a reliable option for TKA when necessary. Thicker PEBs are just as successful in the short term as thinner PEBs. Although the groups were largely similar initially, the study found that patients with a PEB ≥13-mm experienced better outcomes and less postsurgical pain at 6 months and 1 year, particularly as measured by KOOS, JR scores. However, this beneficial effect of thicker bearings was predominantly seen in male patients, with female patients showing similar results regardless of PEB thickness, and both groups had similar short-term complication rates.
Footnotes
None of the following authors or any immediate family member has received anything of value from or has stock or stock options held in a commercial company or institution related directly or indirectly to the subject of this article: Dr. Carpenter, Dr. Strecker, Goldberg, Dr. Nagarkatti, Dr. Shekhman, Dr. Carangelo, and Dr. Witmer.
References
- 1.DeFrance MJ, Scuderi GR: Are 20% of patients actually dissatisfied following total knee arthroplasty? A systematic review of the literature. J Arthroplasty 2023;38:594-599. [DOI] [PubMed] [Google Scholar]
- 2.Feng J, Novikov D, Anoushiravani A, Schwarzkopf R: Total knee arthroplasty: Improving outcomes with a multidisciplinary approach. J Multidiscip Healthc 2018;11:63-73. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Massin P: How does total knee replacement technique influence polyethylene wear? Orthop Traumatol Surg Res 2017;103:S21-S27. [DOI] [PubMed] [Google Scholar]
- 4.Shi JF, Wang CJ, Berryman F, Hart W: The effect of polyethylene thickness in fixed- and mobile-bearing total knee replacements. Proc Inst Mech Eng H 2008;222:657-667. [DOI] [PubMed] [Google Scholar]
- 5.Greco NJ, Crawford DA, Berend KR, Adams JB, Lombardi AV: “Thicker” polyethylene bearings are not associated with higher failure rates in primary total knee arthroplasty. J Arthroplasty 2018;33:2810-2814. [DOI] [PubMed] [Google Scholar]
- 6.Rajamäki A, Niemeläinen M, Junnila M, et al. : Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate‐retaining total knee arthroplasty (TKA): A single‐centre study of 7643 TKAs. Knee Surg Sports Traumatol Arthrosc 2023;31:1018-1025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Farooq H, Oetojo W, Bajwa S, Brown NM: Does thickness of the polyethylene insert impact complications and revisions following total knee arthroplasty? J Orthop Rep 2025;4:100649. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Garceau SP, Warschawski YS, Tang A, Sanders EB, Schwarzkopf RM, Backstein DJ: The effect of polyethylene liner thickness on patient outcomes and failure after primary total knee arthroplasty. J Arthroplasty 2020;35:2072-2075. [DOI] [PubMed] [Google Scholar]
- 9.Pires E Albuquerque RS, Pizziolo TR, da Silva OAT, et al. : Short-term evaluation between polyethylene thickness in primary total knee arthroplasty. Acta Ortop Bras 2024;32:e276755. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Lanting BA, Snider MG, Chess DG: Effect of polyethylene component thickness on range of motion and stability in primary total knee arthroplasty. Orthopedics 2012;35:e170-e174. [DOI] [PubMed] [Google Scholar]
- 11.Crawford DA, Lapsley L, Hurst JM, Morris MJ, Lombardi AV, Berend KR: Impact of polyethylene thickness on clinical outcomes and survivorship in medial mobile-bearing unicondylar knee arthroplasty. J Arthroplasty 2021;36:2440-2444. [DOI] [PubMed] [Google Scholar]
- 12.Khan M, Inglis M, Samson A, Lewis PL, Peng Y, Wilson CJ: The effect of polyethylene thickness on revision rates of contemporary cruciate retaining knee replacements. A registry analysis. Knee 2021;33:243-251. [DOI] [PubMed] [Google Scholar]
- 13.Berend ME, Davis PJ, Ritter MA, et al. : “Thicker” polyethylene bearings are associated with higher failure rates in primary total knee arthroplasty. J Arthroplasty 2010;25:17-20. [DOI] [PubMed] [Google Scholar]
- 14.Lyman S, Lee Y-Y, McLawhorn AS, Islam W, MacLean CH: What are the minimal and substantial improvements in the HOOS and KOOS and JR versions after total joint replacement?. Clin Orthop Relat Res 2018;476:2432-2441. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Singh V, Fiedler B, Huang S, Oh C, Karia RJ, Schwarzkopf R: Patient acceptable symptom state for the forgotten joint score in primary total knee arthroplasty. J Arthroplasty 2022;37:1557-1561. [DOI] [PubMed] [Google Scholar]
- 16.Eckhard L, Munir S, Wood D, et al. : Minimal important change and minimum clinically important difference values of the KOOS-12 after total knee arthroplasty. Knee 2021;29:541-546. [DOI] [PubMed] [Google Scholar]
- 17.Tzanetis P, Marra MA, Fluit R, Koopman B, Verdonschot N: Biomechanical consequences of tibial insert thickness after total knee arthroplasty: A musculoskeletal simulation study. Appl Sci 2021;11:2423. [Google Scholar]
- 18.Gunda B, Goldberg L, Alban A, et al. : The effect of the design of polyethylene inserts in total knee arthroplasty on patient reported outcomes. JAAOS Glob Res Rev 2025;9:e25.00075. [DOI] [PMC free article] [PubMed] [Google Scholar]