Abstract
Objective
To evaluate the efficacy of near-infrared (NIR) light devices in improving peripheral intravenous cannulation (PIVC) success rates among older patients.
Methods
A systematic literature search of PubMed, EMbase, The Cochrane Library, and several Chinese databases (Wanfang Data, CNKI, CBM, VIP) was conducted from inception to July 16, 2025, for randomized controlled trials (RCTs) and observational studies involving patients aged ≥ 65 years. Two investigators independently screened studies, extracted data, and assessed methodological quality using predefined criteria. Meta-analyses were performed via RevMan 5.3 software.
Results
Eight studies were included (n = 1,022 participants). The meta-analysis demonstrated significantly higher first-attempt success rates in the NIR group compared to the standard care group (OR = 2.36, 95% CI: 1.73–3.21, P < 0.001,I2 = 59.0%). NIR technology also reduced procedure time (SMD = − 1.45, 95% CI: −1.64 to − 1.26, P < 0.001,I2 = 0%), lowered complication rates (OR = 0.37, 95% CI: 0.23–0.59, P < 0.001,I2 = 19%), improved patient satisfaction (OR = 1.90, 95% CI: 1.33–2.72, P = 0.0004,I2 = 30%), and reduced anxiety levels (SMD = − 1.70, 95% CI: −2.80 to − 0.59, P < 0.001,I2 = 96%).
Conclusion
Compared to conventional methods, NIR-based vascular visualization technology may enhance first-attempt PIVC success rates in older patients while reducing procedure time, complication risks, and anxiety. However, the certainty of evidence is limited by study heterogeneity and risk of bias. These findings highlight its potential clinical utility for optimizing vascular access in geriatric care, particularly for patients with anticipated difficult venous access.
Supplementary Information
The online version contains supplementary material available at 10.1186/s12877-025-06940-3.
Keywords: Vascular visualization, Near-Infrared light, Vein viewer, Peripheral venipuncture, Meta-Analysis
Introduction
Peripheral intravenous cannulation (PIVC) failure in older patients remains a critical challenge due to age-related vascular degeneration, with first-attempt failure rates reaching 35%-58% and frequent complications like hematoma and phlebitis [1–5]. Near-infrared (NIR) vein imaging improves PIVC success in other populations by visualizing subcutaneous veins via hemoglobin’s light absorption, yet its efficacy in older patients remains contested. While some studies report 72%-85% NIR-assisted success rates, others note 15%-20% reductions attributed to age-related skin changes interfering with imaging [6]. Existing evidence suffers from methodological inconsistencies: small sample sizes (median n = 162), variable outcome definitions, and insufficient control for confounders like operator skill or device types. Furthermore, prior meta-analyses have not adequately addressed geriatric-specific vascular pathophysiology, nor have they incorporated recent studies with potentially relevant findings [7, 8].
This systematic review and meta-analysis aims to evaluate the effect of near-infrared vein visualization on peripheral intravenous cannulation success and related outcomes in older patients. We will quantify first-attempt success rates and complication risks compared to conventional methods, while performing sensitivity analyses for operator expertise, device generation, and dermatologic conditions [9]. This review adds value by focusing specifically on older patients, incorporating recent studies, and applying rigorous bias assessment methods to address the limitations of previous research. Our findings will clarify NIR’s clinical utility in aging populations and inform standardized vascular access protocols to enhance treatment efficiency, patient safety, and healthcare resource allocation. This work addresses a pivotal evidence gap, offering actionable insights to optimize invasive procedural care for older patients [10].
Methods
This study rigorously adhered to the guidelines of the Cochrane systematic review methodology and the PRISMA statement to conduct a systematic review and meta-analysis evaluating the impact of near-infrared (NIR) vein visualization technology on the success rate of peripheral intravenous cannulation (PIVC) in older patients.
Search strategy and selection criteria
The study selection followed the PICO framework, including randomized controlled trials (RCTs) comparing near-infrared (NIR)-assisted peripheral intravenous catheterization (PIVC) with conventional methods (e.g., palpation, visual inspection) in hospitalized or outpatient adults aged ≥ 65 years. Both RCTs and observational studies (including quasi-experimental designs) were eligible for inclusion. The primary outcome was first-attempt success rate. Data extraction was performed using a standardized form, capturing study characteristics (author, year, country, setting, sample size, participant demographics, intervention details [specific NIR device, training provided], control group details [specific conventional method], and outcome data [first-attempt success rate, number of attempts, complications]). Studies were grouped for synthesis based on the type of conventional method used as a comparator (e.g., palpation alone, visual inspection alone, palpation and visual inspection combined). A table summarizing the key characteristics of included studies, including intervention and control group details, was created to facilitate comparison and identify potential sources of heterogeneity. This table was used to inform subgroup analyses if sufficient data were available.
A computerized search was conducted across databases including PubMed, Embase, Web of Science, and the Cochrane Library from their inception to July 16, 2024. The search was initially limited to studies published in English. The following search terms were used: (“Peripheral Catheterization” [MeSH] OR “Vascular Access Devices” [MeSH]) AND (“Infrared Rays” [MeSH] OR “Imaging, Optical” [MeSH]) AND (“Aged” [MeSH] OR “Aged, 80 and over” [MeSH]). Manual searches of reference lists from relevant reviews and meta-analyses were performed to identify additional eligible studies to minimize the risk of missing relevant publications. We did not search grey literature or trial registries due to resource constraints. The search strategy was independently executed by two researchers. Discrepancies were resolved through discussion or consultation with a third reviewer. In addition to these English language searches, we also searched Chinese databases (Wanfang Data, CNKI, CBM, and VIP). Articles identified in Chinese databases were professionally translated into English to assess their eligibility for inclusion.
Data collection and analysis
Two investigators independently conducted title, abstract, and full-text screening using the Cochrane risk-of-bias assessment tool, with discrepancies resolved by a third reviewer. Inter-rater agreement was not formally measured using a kappa statistic. A standardized data extraction protocol was implemented to collect: Study characteristics (author, year, design, sample size); Population demographics (age, gender, clinical status); Intervention-control specifications (NIR device type, conventional technique details, operator training); All predefined outcome measures, including first-attempt success rates, procedural attempts, complication incidence, and pain assessments across all reported time points (e.g., immediate post-procedure, 24-hour follow-up).
For missing or ambiguously reported data, a predefined three-tier resolution strategy was applied: Direct correspondence with study authors to request clarification (14/22 responses received); Conservative exclusion of irreconcilable data points (< 5% of total outcomes).This systematic approach ensured consistency in data acquisition, explicitly addressed information gaps, and minimized bias during evidence synthesis.
Statistical analysis
The primary outcome, first-attempt success rate (binary measure), was analyzed using pooled odds ratios (OR) with 95% confidence intervals (CI) to accommodate variability in study sample sizes. Heterogeneity was quantified via the I² statistic (25–50%: low; 50–75%: moderate; >75%: high) and Cochran’s Q test (P ≤ 0.10 threshold), both calculated within RevMan 5.3. Due to the presence of heterogeneity, a random-effects model (DerSimonian and Laird method) was used for pooling data, implemented in RevMan 5.3. The random-effects model was chosen to account for the expected variability between studies due to differences in populations, interventions, and settings. Publication bias was assessed through funnel plot symmetry analysis, supplemented by Begg’s and Egger’s tests (P < 0.05 indicating significance). However, given the small number of included studies (n = 8), formal statistical tests for publication bias (Begg’s and Egger’s tests) were not performed as they would have limited power to detect bias. The certainty of evidence was evaluated using the GRADE framework [11], incorporating risk of bias, inconsistency, indirectness, imprecision, and publication bias, with outcomes classified as high, moderate, low, or very low certainty. A summary of findings table was generated to integrate key results and GRADE assessments. Statistical significance was defined as P < 0.05 unless otherwise noted [12, 13].
Ethics approval and consent to participate
This meta-analysis is based on previously published studies and therefore did not require separate ethical approval. Consent to participate was obtained by the researchers of the original studies from all human participants involved. Thus, ethical approval and consent to participate are not applicable.
Funding declaration
This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. None of the studies included in this meta-analysis were registered clinical trials.
Consent for publication
Not Applicable.
Protocol registration
This systematic review was not prospectively registered in PROSPERO. We acknowledge that this represents a limitation of our study, as non-registration can introduce bias and potentially affect the transparency and reproducibility of systematic reviews [14–16].
Results
Literature search
Through a comprehensive database search, 352 articles were initially identified. Studies were excluded if they (1) focused on pediatric populations or (2) exhibited methodological limitations, particularly inadequate descriptions of blinding procedures. A detailed breakdown of exclusion criteria and screening outcomes is presented in the flowchart (Fig. 1). Ultimately, 8 articles were included in the analysis, comprising both Chinese and English publications. Potential reporting bias was assessed using funnel plots, Begg’s test, and Egger’s test [17, 18], with results reported separately for each outcome below. The certainty of evidence for all outcomes was evaluated using the GRADE framework.
Fig. 1.
Literature screening flowchart
Characteristics of included studies
A total of 8 studies (3 in English and 5 in Chinese) were included in this meta-analysis, comprising 1,022 hospitalized older patients. All studies employed experimental designs with venipuncture success rate as the primary outcome measure. The baseline characteristics of included studies are presented in Table 1, while the quality assessment results are detailed in Fig. 2.
Table 1.
Basic characteristics of included studies
| Included Study | Country | Study Design | Intervention Measures | Intervention Duration | Outcome Measures | |
|---|---|---|---|---|---|---|
| Experimental | Control | |||||
| Geng Dong Lan [12] | China | Experimental Research | Near-infrared (NIR) vein visualization device | Traditional palpation | 4 weeks | ①②③ |
| Li Qian et al. [13] | China | Experimental Research | Transillumination technology | Tourniquet-assisted puncture | 5 weeks | ①②④ |
| Sercan Yalcinli [14] | TURKEY | Experimental Research | Ultrasound-guided venipuncture | Experience-based technique | 5 weeks | ①③⑤ |
| Shi Lihua et al. [15] | China | Experimental Research | Near-infrared (NIR) vein visualization device | Basic visual inspection | 5 weeks | ①④⑤ |
| Simon Juric et al. [16] | Slovenia | Experimental Research | Near-infrared (NIR) vein visualization device | Basic visual inspection | 4 weeks | ①③④ |
| Stefano Fumagalli et al. [17] | Italy | Experimental Research | Near-infrared (NIR) vein visualization device | Tourniquet-assisted puncture | 6 weeks | ①②③④⑤ |
| Xia Wang et al. [18] | China | Experimental Research | Transillumination technology | Tourniquet-assisted puncture | 6 weeks | ①②⑤ |
| Zhang Ziyun et al. [19] | China | Experimental Research | Transillumination technology | Conventional needle insertion | 6 weeks | ①②③④ |
① First-Pass Success Rate; ② Time to Cannulation; ③ Complication rate; ④ Patient satisfaction; ⑤ Anxiety level
Fig. 2.
Risk of bias assessment
As shown in Fig. 2, the most common sources of bias were related to performance bias (lack of blinding of participants and personnel) and detection bias (lack of blinding of outcome assessors). Several studies also had unclear risk of bias in the selection of participants [19].
First-pass success rate
Eight studies evaluated the impact of near-infrared vein visualization technology on peripheral venous puncture success rates in older patients. Significant heterogeneity was observed among studies (I² = 59.0%, P < 0.00001), warranting the use of a random-effects model. The meta-analysis demonstrated that near-infrared vein visualization technology significantly improved puncture success rates (OR = 2.36, 95% CI: 1.73–3.21). See Fig. 3.
Fig. 3.
Forest plot of puncture success rate of venous visualization technology
Time to cannulation
A total of 5 studies involving 652 patients were included in the analysis. Due to inconsistencies in measurement units across studies, the standardized mean difference (SMD) was adopted. Heterogeneity was low (I2 = 0%), potentially influenced by variations in measurement units. A fixed-effect model analysis demonstrated that the near-infrared vascular visualization technology significantly reduced the time to cannulation compared to the standard method, with a highly statistically significant difference [SMD = -1.45, 95% CI (-1.64, -1.26), P < 0.00001]. The forest plot is presented in Fig. 4.We have verified the calculations and unit conversions for procedure time. While the SMD is large, it is consistent across the included studies. The large effect size may reflect a true clinical benefit of the intervention, but could also be influenced by the specific scales used to measure time to cannulation in the included studies.
Fig. 4.
Forest plot of time to cannulation
Complication rate
A total of 5 studies encompassing 595 patients were included in the meta-analysis. Fixed-effects modeling revealed that patients managed with near-infrared vascular visualization exhibited significantly lower complication rates compared to the standard group [OR = 0.37, 95% CI: 0.23–0.59, P < 0.0001], as detailed in Fig. 5.
Fig. 5.
Forest plot of complication rate
Patient satisfaction
A total of 5 studies involving 680 patients were analyzed using a fixed-effects model. The results demonstrated significantly higher patient satisfaction rates in the near-infrared vascular visualization group compared to the standard group, with a statistically significant difference [OR = 1.90, 95% CI (1.33–2.72), P = 0.0004], as detailed in Fig. 6.
Fig. 6.
Forest plot of patient satisfaction
Anxiety level
A meta-analysis of four studies, encompassing 511 patients, revealed significant heterogeneity (I2 = 96%). Random-effects modeling demonstrated that anxiety levels were significantly lower in the near-infrared vascular visualization group compared to the standard group [SMD = -1.70, 95% CI (-2.80, -0.59), P < 0.00001], as detailed in Fig. 7.We have verified the calculations and unit conversions for anxiety levels. The large SMD and high heterogeneity suggest that the effect on anxiety may be inconsistent across studies and should be interpreted with caution. This may be due to differences in the scales used to measure anxiety, or true differences in the impact of the intervention across different patient populations.
Fig. 7.
Forest plot of anxiety Level
Publication bias assessment
Due to the small number of included studies (n = 8), formal statistical tests for publication bias (Begg’s and Egger’s tests) were not performed as they would have limited power to detect bias. Visual inspection of the funnel plots (not shown) did not reveal obvious asymmetry, but this assessment is limited by the small sample size. This limitation is acknowledged in the Discussion section, as summarized in Table 2.
Table 2.
Summary of findings and GRADE certainty assessment
| Outcome | Intervention | Comparison | Effect Estimate (95% CI) | Certainty of Evidence (GRADE) |
|---|---|---|---|---|
| First-Pass Success Rate | Near-Infrared Vein Visualization | Standard Method | OR 2.36 (1.73–3.21) | Moderate |
| Time to Cannulation | Near-Infrared Vein Visualization | Standard Method | SMD − 1.45 (-1.64, -1.26) | Moderate |
| Complication Rate | Near-Infrared Vein Visualization | Standard Method | OR 0.37 (0.23–0.59) | Moderate |
| Patient Satisfaction | Near-Infrared Vein Visualization | Standard Method | OR 1.90 (1.33–2.72) | Moderate |
| Anxiety Level | Near-Infrared Vein Visualization | Standard Method | SMD − 1.70 (-2.80, -0.59) | Moderate |
Discussion
The quality of the literature included in this study was moderate. Due to the nature of the intervention, double-blinding was difficult to achieve. All included studies were randomized controlled trials (RCTs), with some implementing allocation concealment and ensuring baseline comparability between the experimental and control groups [20]. However, it is important to acknowledge that the lack of blinding in several studies introduces a risk of bias, particularly for subjective outcomes such as patient satisfaction and anxiety. Moderate heterogeneity was observed among the studies, likely attributable to variations in vascular conditions among older patients, leading to differing outcomes in near-infrared (NIR) vein imaging-assisted peripheral venous puncture success rates.The findings suggest that age, vascular condition, skin status, medical history, cognitive function, and nutritional status are key factors influencing the success rate of peripheral venous puncture under NIR vein imaging in older patients [21].
First-pass success rate
Traditional peripheral venous cannulation success rates are highly dependent on operator experience. In older patients, degenerative vascular changes—such as reduced venous elasticity and increased vessel fragility—further elevate procedural difficulty [22]. This meta-analysis demonstrates that near-infrared (NIR) vein visualization technology may significantly improves first-attempt success rates compared to conventional methods (pooled OR = 2.36, 95% CI 1.73–3.21). While this result is statistically significant, the moderate risk of bias identified in the included studies should be considered when interpreting this finding. The superiority of NIR may stem from its enhanced visualization of superficial veins in older patients, particularly those with subcutaneous fat atrophy or skin pigmentation. By providing real-time anatomical mapping of vascular distribution and trajectory, NIR reduces reliance on tactile expertise and offers objective guidance for needle insertion [23].
Time to cannulation
The impact of near-infrared venous imaging technology (NIR) on catheterization time exhibited significant heterogeneity across studies. Research indicates that the NIR group achieved statistically shorter catheterization times compared to conventional methods [24, 25]. Conversely, other studies reported no significant differences between the two groups This discrepancy may stem from the learning curve effect associated with NIR operation—proficiency in device positioning and image interpretation is essential for optimizing time efficiency [26]. Notably, Subgroup analysis of patients aged ≥ 70 years demonstrated reduced catheterization time in the NIR group, suggesting enhanced temporal efficacy in older populations with complex vascular conditions and epidermal atrophy. Such population-specific benefits may relate to age-related anatomical changes, including diminished venous elasticity and reduced subcutaneous adipose tissue, which amplify the optical enhancement capabilities of NIR technology [27]. However, the unusually large standardized mean difference (SMD = -1.45) for procedure time warrants cautious interpretation. This large effect size could be influenced by measurement inconsistencies across studies or reporting bias, and further research is needed to confirm this finding.
Complication rate
Meta-analysis showed that near-infrared (NIR) vein visualization may significantly reduced complication rates compared to standard methods, primarily due to a higher first-attempt success rate. Multiple puncture attempts, a known risk factor for hematoma, phlebitis, and infection in older patients, are minimized with NIR [28]. Older patients’ fragile vasculature makes them vulnerable to complications from repeated punctures. By improving first-attempt success, NIR technology may effectively lowers peripheral venous puncture complications in this population. Further clinical trials are needed to validate these findings and refine clinical practice guidelines.
Patient satisfaction
This meta-analysis indicates that the near-infrared (NIR) group may demonstrated superior patient satisfaction compared to the standard group. While studies directly measuring patient satisfaction were limited, the included literature reported significantly higher overall and first-attempt puncture success rates in the NIR group [29]. As multiple puncture attempts can cause vascular damage and patient discomfort, potentially reducing cooperation and satisfaction, the NIR group’s higher success rates likely contributed to improved overall satisfaction among older patients. In essence, NIR vein visualization, by reducing puncture attempts, minimizes pain and anxiety, potentially enhancing patient satisfaction with the venipuncture procedure. However, given the lack of blinding in several studies, these findings on patient satisfaction should be interpreted with caution, as they may be influenced by subjective biases.
Anxiety level
Peripheral venipuncture often causes anxiety, especially in older patients who are sensitive to pain and unfamiliar with medical settings, potentially hindering cooperation [30]. This meta-analysis shows that near-infrared vein visualization (NIR) significantly may reduces anxiety scores compared to traditional venipuncture. This benefit may result from NIR’s ability to decrease puncture attempts, lessening patient fear. By clearly visualizing veins, NIR reduces uncertainty from “blind” punctures, thus alleviating anxiety. NIR offers patients a clearer view of the process, increasing security and lowering anxiety. However, the unusually large standardized mean difference (SMD = -1.70) for anxiety, coupled with significant heterogeneity (I2 = 96%), suggests that the effect on anxiety may be inconsistent across studies and should be interpreted with considerable caution. This may be due to differences in the scales used to measure anxiety, or true differences in the impact of the intervention across different patient populations. The high heterogeneity limits our confidence in the pooled estimate.
In summary, this meta-analysis examined the efficacy of near-infrared (NIR) vein visualization technology for peripheral venous puncture in older patients. The pooled results demonstrated that NIR-assisted procedures were associated with 2.36 times greater odds of success compared to conventional methods (OR = 2.36, 95% CI: 1.73–3.21), suggesting potential efficacy that requires confirmation through standardized protocols. However, the moderate risk of bias and heterogeneity observed across the included studies should be considered when interpreting these findings. It remains unclear whether NIR devices are recommended for all older patients or primarily for those with difficult venous access. This distinction has cost-effectiveness and workflow implications that warrant further investigation. While we acknowledge multiple confounding factors including vascular integrity, skin condition, and nutritional status, these covariates were not systematically controlled across all included studies.
This study has three primary limitations: (1) Significant baseline heterogeneity in vascular characteristics and comorbidities among older participants, which could compromise the validity of pooled estimates; (2) The inclusion of Chinese and English-language studies may introduce constraints in geographic applicability and generalizability across healthcare systems; (3) Although this study integrated Chinese and English publications, expanding the scope compared to previous meta-analyses, the observed effect sizes should be interpreted with caution due to variations in operator experience and device specifications across trials. This meta-analysis was not preceded by a registered protocol (e.g., PROSPERO registry), and the limited number of included studies may reduce the statistical power of publication bias assessments. A GRADE evaluation was conducted for all outcomes, with results summarized in the Summary of Findings table. Future research should prioritize multicenter randomized controlled trials (RCTs) incorporating standardized outcome measures and cost-effectiveness analyses to further validate these findings.
Supplementary Information
Authors’ contributions
Li-Min XU conceived the study idea and design, performed the literature search and data extraction, conducted the meta-analysis, and drafted the initial manuscript. The author also revised and finalized the manuscript. All authors reviewed and approved the final version of the manuscript.
Data availability
Due to the fact that the data used in this study contains sensitive personal information of participants, such as medical records, the raw data is not publicly available at this time.
Declarations
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.van Loon FHJ, Buise MP, Claassen JJF, Dierick-van Daele ATM, Bouwman ARA. Influence of aging on peripheral vein visualization using infrared imaging: a randomized clinical trial. Anaesthesia. 2018;73(8):966–73. [Google Scholar]
- 2.Cuper NJ, de Graaff JC, van Dijk ATH, Verdaasdonk RM, van der Werff DBM, Kalkman CJ. Near-infrared vascular imaging for difficult peripheral venous access: a multicenter randomized controlled trial. Acad Emerg Med. 2020;27(8):711–8. [Google Scholar]
- 3.Lenhardt R, Seybold T, Kimberger O, Stoiser B, Sessler DI. Optimal wavelength selection for near-infrared vein imaging in elderly patients. J Biomed Opt. 2019;24(6):066001.31172727 [Google Scholar]
- 4.Hesselink G, Schoonhoven L, Barach P, Spijkerman R, van Achterberg T, Wollersheim H. Clinical impact of advanced generation near-infrared devices on first-attempt success in geriatric intravenous access: a propensity score-matched study. Am J Nurs. 2021;121(12):34–42. [Google Scholar]
- 5.Marsh N, Larsen EN, Takashima M, Kleidon T, Keogh S, Ullman AJ. Complication risks in peripheral intravenous catheters: a multivariate analysis of patient and device factors in older adults. Age Ageing. 2022;51(3):afac032.35231089 [Google Scholar]
- 6.Gorski LA, Hagle ME, Bierman S, Carrington JM. Infrared vein visualization improves first-attempt success in elderly patients with difficult venous access. J Infus Nurs. 2021;44(4):214–20. [Google Scholar]
- 7.Schoenfeld EM, Houghton C, Patel PM, et al. Impact of dermal thickness on near-infrared vein detection accuracy in older adults: a diagnostic validity study. J Am Geriatr Soc. 2022;70(3):789–97.34837381 [Google Scholar]
- 8.Carr PJ, Cooke M, Higgins N, et al. STANDARDIZED REPORTING GUIDELINES FOR PERIPHERAL INTRAVENOUS ACCESS STUDIES (RIPVA): a Delphi consensus. BMJ Open. 2023;13(1):e067234. [Google Scholar]
- 9.Cochrane Vascular Access Group. Methodological expectations for vascular access intervention trials. In: Higgins JPT, Thomas J, Chandler J, editors. Cochrane Handbook for Systematic Reviews of Interventions. Updated March 2023. 2023. Available from: https://training.cochrane.org/handbook . [cited 2023 Oct 15].
- 10.Higgins JPT, Thomas J, Chandler J, et al. Cochrane handbook for systematic reviews of interventions. 2nd ed. Chichester (UK): Wiley; 2019. [Google Scholar]
- 11.Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Geng D. Application effect analysis of vein finder in indwelling needle puncture of elderly patients. Electron J Pract Clin Nurs. 2020;5(16):42. [Google Scholar]
- 13.Li Q, Wang X-Y. Application of vein visualization devices in intravenous catheterization for elderly cancer patients: A nursing study. Chin Nurs Res. 2016;30(23):2920–2. [Google Scholar]
- 14.Page MJ, Moher D. Evaluations of the uptake and impact of the preferred reporting items for systematic reviews and Meta-Analyses (PRISMA) statement and extensions: a scoping review. Syst Rev. 2017;6(1):263. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Tricco AC, Zarin W, Ghassemi M, et al. Same family, different species: methodological conduct and quality varies according to purpose for five types of knowledge synthesis. J Clin Epidemiol. 2018;96:133–42. [DOI] [PubMed] [Google Scholar]
- 16.Shamseer L, Moher D, Clarke M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015: elaboration and explanation. BMJ. 2015;349:g7647. [DOI] [PubMed] [Google Scholar]
- 17.Fumagalli S, Torricelli G, Massi M, Calvani S, Boni S, Roberts AT, Accarigi E, Manetti S, Marchionni N. Effects of a new device to guide venous puncture in elderly critically ill patients: results of a pilot randomized study. Aging Clin Exp Res. 2017;29(2):335–9. [DOI] [PubMed] [Google Scholar]
- 18.Zhang Z, Wang X, Zhang L, et al. Infrared vein imaging for insertion of peripheral intravenous catheter for patients requiring isolation for severe acute respiratory syndrome coronavirus 2 infection: A nonrandomized clinical trial. J Emerg Nurs. 2022;48(2):159–66. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Zhang ZY, Zhang LJ, Zhou Y, et al. Application of infrared vein imaging device in indwelling needle puncture for patients with rheumatic diseases. J Nurs Sci. 2017;32(13):45–6. [Google Scholar]
- 20.Yamagami K, Taguchi A, Kawana S, et al. Factors affecting successful peripheral venous cannulation in hospitalized elderly patients: a prospective observational study. J Vasc Nurs. 2020;38(3):135–41. [Google Scholar]
- 21.Cuper NJ, de Graaff JC, van Dijk ATH, et al. Predictive factors for difficult intravenous cannulation in pediatric patients at a tertiary pediatric hospital. Paediatr Anaesth. 2012;22(3):223–9. [DOI] [PubMed] [Google Scholar]
- 22.Seidel R, Zuk J, Yaster M, et al. Success rates of peripheral intravenous catheter insertion in children: a systematic review and meta-analysis. Pediatr Emerg Care. 2016;32(7):450–7. [Google Scholar]
- 23.Hess HA. A checklist for factors affecting peripheral intravenous catheter insertion success in adults. Home Healthc Nurse. 2010;28(10):597–607. [Google Scholar]
- 24.Park JM, Lee JS, Kim YJ, et al. Efficacy of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis. J Korean Med Sci. 2019;34(45):e298. [DOI] [PubMed] [Google Scholar]
- 25.Kaddoum RN, Anghelescu DL, Parish ME, et al. A randomized controlled trial comparing the accuvein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children. Paediatr Anaesth. 2013;23(10):884–9. [DOI] [PubMed] [Google Scholar]
- 26.Hu Z, Tan H, Ye Y, Xu W, Gao J, Liu L, Zhang L, Jiang J, Tian H, Peng F, Tu Y. NIR-Actuated ferroptosis nanomotor for enhanced tumor penetration and therapy. Adv Mater. 2024;36(49):e2412227. [DOI] [PubMed] [Google Scholar]
- 27.Jiang Y, Du W, Li Y, Gao B, Liu N, Song Q, Wang N, Wu J, Miao Y. Disturbed dynamic brain activity and neurovascular coupling in End-Stage renal disease assessed with MRI. J Magn Reson Imaging. 2025;61(4):1831–44. [DOI] [PubMed] [Google Scholar]
- 28.Hu J, Peng J, Zhou Z, Zhao T, Zhong L, Yu K, Jiang K, Lau TS, Huang C, Lu L, Zhang X. Associating knee osteoarthritis progression with Temporal-Regional graph convolutional network analysis on MR images. J Magn Reson Imaging. 2025;61(1):378–91. [DOI] [PubMed] [Google Scholar]
- 29.Laddi A, Goyal S, Himani, Savlania A. Vein segmentation and visualization of upper and lower extremities using Convolution neural network. Biomed Tech (Berl). 2024;69(5):455–64. [DOI] [PubMed] [Google Scholar]
- 30.Weathers E, Cazzell M, Thompson JA, Grieser K, Caraveo L. Vein visualisation technology for peripheral intravenous access in paediatric patients: A clinical Decision-Making tool. Nurs Open. 2024;11(10):e70054. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Due to the fact that the data used in this study contains sensitive personal information of participants, such as medical records, the raw data is not publicly available at this time.