Skip to main content
. 2026 Jan 19;16:5715. doi: 10.1038/s41598-026-36276-w

Table 8.

Quantitative results of different types of crack testing based on poisson fusion degree.

Reference crack lengths (mm) 1 2 3 7 8 10
Maximum poisson fusion degree 0.035 0.055 0.052 0.045 0.046 0.043
Quantitative lengths (mm) 1.3 1.95 2.98 7.2 8.3 9.7
Quantitative error (%) 0.23 −0.03 −0.01 0.03 0.04 −0.03
Mean absolute error 0.198