The effect of air deflector angle on ventilation systems in laying hen houses during summer based on CFD analysis

Changzeng Hu a,b,c, Zongkui Xie a,b,c, Yuchen Jia a,b,c, Hao Xue a,b,c, Lihua Li a,b,c,⁎, Limin Huo a,b,c
PMCID: PMC12892073  PMID: 41643442

Abstract

Negative pressure ventilation serves as the primary method for environmental control in poultry houses, with deflector plates functioning as one of the most effective active control devices within this system. However, the precise control mechanism by which deflector plates influence ventilation system performance remains unclear. This study investigated the impact of varying deflector plate angles (ranging from 15° to 90°) on ventilation performance through a combined experimental and numerical simulation approach, adjusting the opening angle of the deflector plates. Experimental results indicate that deflector plate angle significantly impacts ventilation efficiency and thermal environment. Increasing the deflector plate angle expands the air intake area and reduces airflow velocity, enabling more cage areas to fall within the comfortable wind speed range of 0.5–2 m/s while minimizing uneven airflow distribution within the poultry house. Larger angles elevate overall cage area temperatures, whereas smaller angles minimize indoor temperature fluctuations, keeping more laying hens within the comfort temperature zone. The optimal angle range for balancing ventilation requirements and ensuring animal welfare is between 60° and 75°. This study also established a theoretical model for predicting mass flow based on deflector plate angle, with calculated values exhibiting a relative error of less than 9.49% compared to experimental data. Experimental verification of the deflector plate angle's impact on laying hen house ventilation systems provides a theoretical basis for optimizing ventilation system design.\

Keywords: Ventilation system, Air deflector, Thermal comfort, Theoretical model, Mass flow rate

Introduction

With the continuous improvement of living standards and rapid changes in dietary patterns, eggs and related products have gradually replaced meat as a significant component of people's diets (Dussiot et al., 2023; Li et al., 2024). As demand grows, egg production has shifted from traditional free-range farming toward intensive, large-scale operations (Yang et al., 2022; Ni, 2024). Correspondingly, poultry housing designs have diversified to accommodate varying farm scales (Ma et al., 2022; Deng et al., 2024).

Multiple poultry building styles have emerged for different production capacities, though elongated structures remain predominant. Ventilation systems for these buildings predominantly utilize traditional negative pressure ventilation (Rojano et al., 2016; Tong et al., 2020). In Cheng et al.'s study, a small-scale farm housing 28,717 birds employed longitudinal negative pressure ventilation from front to rear (Cheng et al., 2018). Hu et al.'s research on a medium-sized farm with 42,000 birds utilized a combined ventilation system featuring negative pressure fans as the primary method and positive pressure fans as auxiliary (Hu et al., 2024). Tong et al. studied a large-scale farm with 162,000 birds employing top-to-bottom vertical negative pressure ventilation (Tong et al., 2019b). As the most widely applied ventilation model, negative pressure ventilation suits the majority of poultry buildings due to its simple structure and efficient control characteristics.

The most common strategy for negative pressure ventilation involves installing air intake vents with deflector plates and evaporative cooling pads at the front end of the poultry house, while exhaust fans are positioned at the rear end. Air is drawn into the house from one end and expelled from the other (Fidaros et al., 2018). To prevent cold air from directly entering the poultry activity zone, hinged deflectors at the bottom of the intake guide cold air toward the upper part of the house, where it mixes with warmer air before entering the poultry activity area. The principle of negative pressure ventilation involves actively exhausting air via fans to create a static pressure lower than the outside environment. This forces fresh air to enter uniformly through the intake vents. Guided by the negative pressure, the air distributes evenly throughout the entire poultry house, removing harmful gases, dust, and excess humidity while avoiding ventilation dead zones (Du et al., 2019b; Tong et al., 2019a). Current literature contains relatively few case studies on how inlet design affects the performance of negative pressure ventilation systems in laying hen houses, and research on control mechanisms for air deflector tilt angles remains largely unexplored. Du et al. used CFD simulations to investigate how inlet placement and area influence mechanical ventilation performance. Results showed that positioning inlets at mid-height on side walls significantly reduced high temperatures at building ends without additional energy consumption. For elongated buildings matching the negative pressure ventilation model of large-scale poultry farms, increasing the inlet area can substantially lower indoor temperatures (Du et al., 2019a). Cheng et al. simulated the effect of installing deflectors beneath the ceiling to direct incoming fresh air toward the flock activity zone, thereby enhancing airflow uniformity and velocity distribution within the house (Cheng et al., 2018). Understanding how intake design and management influence negative pressure ventilation performance and achieving airflow path control are critical for optimizing design (Marques et al., 2015; Zhao et al., 2025). Therefore, establishing a control mechanism based on air deflector devices within negative pressure ventilation systems is urgently needed.

The process by which ventilation systems regulate indoor environments involves complex influencing mechanisms. Most relevant studies employ theoretical modeling approaches, which not only significantly reduce time costs but also provide practical application guidance (Khattri et al., 2021; Wang et al., 2016). The natural ventilation system analysis model proposed by Tao et al. can predict ventilation rates with fewer input parameters, enabling precise forecasting of natural ventilation performance in complex environments (Tao et al., 2021). Zhao et al. employed multi-point measurement methods to collect data, establishing a ventilation performance prediction model for double-skin curtain wall buildings with natural ventilation. This model predicts how different louver tilt angles affect natural ventilation performance (Zhao et al., 2025). Tu et al. calculated cooling performance parameters for sprinkler systems based on thermal equilibrium equations, developing temperature control strategies by determining regulation cycle durations through computation (Tu et al., 2022). The establishment of the aforementioned theoretical model provides an intuitive demonstration of the quantitative relationship between building performance and control systems. Currently, predictive models for the effect of deflector plate tilt angles on controlling the mass flow rate at intake vents in laying hen houses remain an unexplored area of research. The development of a mass flow prediction model provides a scientific, quantitative basis for regulating operations that currently rely on experience. It addresses the limitations of field experience—which is highly subjective—and the high computational costs associated with CFD simulations. By establishing a direct mathematical relationship between the deflector plate angle and airflow volume, this model enables rapid prediction and optimization of ventilation performance. This facilitates precise environmental control, enhances the energy efficiency and stability of poultry house ventilation systems, and represents a crucial step toward achieving intelligent ventilation management.

Overall, air inlet guide vanes play a crucial role in controlling air velocity and direction within ventilation systems. By appropriately adjusting the tilt angle of these vanes, air inlets can achieve precise ventilation to stabilize airflow and enhance thermal comfort. Understanding the impact of deflector plate inclination angles on ventilation system performance is crucial for optimizing design solutions. Experimental research on mechanical ventilation performance under varying deflector plate angles has become a significant and pressing issue in this field. To address this challenge, this study employs a combined approach of field measurements and simulation modeling. A simulation model was established using Fluent software, validated with experimental data, and analyzed to assess the influence of different deflector plate inclination angles on mechanical ventilation effectiveness. A theoretical model was developed to predict the mass flow rate at the outlet under various inclination angles, providing technical guidance for the optimized design of building ventilation systems.

Materials and methods

Experimental facility

The experimental facility is a factory-style egg-laying hen house located in Shahe City, Xingtai, Hebei Province, China. The hen house measures 100m in length and 15m in width, with side walls designed at 4.5m in height—exceeding the height of the cages. The maximum distance from floor to ceiling is 5.3m. The cages measure 1.22m in length, 1.22m in width, and 0.4m in height, arranged in a stacked configuration of 4 tiers and 5 rows. The facility is equipped with fully automated ventilation systems.

The ventilation system comprises 18 exhaust fans with a diameter of 1.4m and an airflow capacity of 38,000m³/h. These negative pressure fans are installed in two evenly spaced rows along one end wall. The intake system consists of six air guide panels measuring 21.0m × 0.4m, mounted at the front of both side walls. These panels feature hinged mechanisms to control their opening angle, as illustrated in Fig. 1.

Fig. 1.

Fig 1 dummy alt text

Experimental laying hen house structure: (a) Ventilation system structure; (b) Side view of experimental laying hen house; (c) Chicken activity area.

Definition of air deflector angle

Air deflectors are installed on both side walls at a height of 0.5m or higher above the ground, as shown in Fig. 2a. Each side wall's air outlet consists of three air deflectors. When closed, the spacing between adjacent deflectors is 5cm. The tilt angle θ represents the angle between the air deflector and the vertical direction, as illustrated in Fig. 2b. The deflector plate tilt angle is adjustable within a range of 0 to 90 degrees. By testing the ventilation performance of the laying hen house ventilation system at different deflector plate opening angles, the relationship between the deflector plate opening angle and the environmental regulation within the laying hen house is investigated.

Fig. 2.

Fig 2 dummy alt text

Ventilation system configuration: (a) Air deflector position; (b) definition of air deflector angle.

CFD simulation

Model setup

This study employed the commercial software Fluent to conduct a three-dimensional simulation of the indoor environment within a laying hen house. The geometric model of the hen house was developed using SpaceClaim, employing a wall-thickness-free modeling approach based on its actual dimensions (as shown in Fig. 3). The hen house was constructed with an east-west orientation. A coordinate system was established with the southeast corner grounding point as the origin, with the positive X-axis direction facing west and the positive Z-axis direction facing north.

Fig. 3.

Fig 3 dummy alt text

Three-dimensional model of the laying hen house.

This study focuses on investigating the distribution of environmental parameters under low-velocity, incompressible gas conditions in laying hen houses. Therefore, a steady-state analysis was conducted, employing a pressure-based solver to address complex boundary conditions. For the steady-state flow problem, the SIMPLE algorithm was utilized to handle the coupling between the pressure field and velocity field.

This study investigates the operational performance of cooling ventilation systems during summer heat waves. Using the method of multiple measurements at finite positions, surface temperatures of the ceiling, floor, and walls were measured with an infrared thermography camera (testo 890, infrared resolution 640 × 480 pixels, thermal sensitivity < 40 mK). Five representative points were selected on each surface for measurement, with 20 samples recorded at each point. The measurement results were used to set boundary conditions. The inlet temperature and humidity of the guide vane were directly measured using temperature and humidity sensors. The number of fans to be activated shall be determined based on actual on-site conditions. Detailed boundary conditions are specified in Table 1.

Table 1.

Boundary conditions.

Parameter Value
Air deflector Pressure inlet, 24°C
Exhaust fan Velocity inlet, -6m/s
Number of fans 16
Energy source 338.04W/m3
Ceiling No slip wall, 19.4°C
Ground No slip wall, 11.1°C
Front wall No slip wall, 14.9°C
End wall No slip wall, 14.1°C
Side wall-A No slip wall, 13.7°C
Side wall-B No slip wall, 14.2°C

The chicken activity area is modeled as a porous medium to simulate the flock's obstruction of airflow in the simulation. The presence of chickens increases airflow resistance, reduces wind speed, and alters flow field distribution. Employing a porous medium model simplifies complex structures while efficiently reflecting their overall resistance characteristics, thereby enabling a more accurate assessment of ventilation effectiveness within the poultry house. The viscous resistance coefficients are shown in Table 2.

Table 2.

Viscous (Dx, Dy, Dz) and inertial (Cx, Cy, Cz) drag coefficients in the x, y, and z directions.

X-direction Y-direction Z-direction
Dx, m-2 Cx, m-1 Dy, m-2 Cy, m-1 Dz, m-2 Cz, m-1
11381.20 0.82 22005.50 3.23 7121.50 2.27

Using random sampling, 20 measurement points were selected across the entire chicken coop area to weigh 160 chickens, yielding an average weight of approximately 1.9 kg. The heat generated by the chickens is transferred to the surrounding environment at a steady rate. During simulation, the chicken cage area was modeled as a porous medium region with a fixed heat source. The heat produced by the laying hens is determined by (1), (2) below.

THP=7m0.75[4×10−5(20−T)3+1] (1)
SHP=[0.8−1.85×10−7(T+10)4]×THP (2)

Mesh partitioning and independence verification

This study employs a combined tetrahedral-polyhedral mesh partitioning approach, which demonstrates exceptional adaptability to complex geometries. Polyhedral meshes, featuring more adjacent faces per element, significantly enhance numerical accuracy while reducing discretization errors during computation. Additionally, the shorter gradient calculation paths in polyhedral elements accelerate numerical convergence, substantially reducing the number of iterations and computational time required.

Numerical accuracy directly depends on mesh resolution. Coarse meshes may fail to capture critical flow features, while excessive refinement unnecessarily increases computational cost. To balance computational resources and accuracy, the validity of numerical solutions at the current mesh resolution is confirmed by systematically refining the mesh and observing temperature variations. This study compares the accuracy of simulation results across different mesh sizes using air temperatures at six positions at a height of 1.4 m (Fig. 4).

Fig. 4.

Fig 4 dummy alt text

Results of the grid independence test.

The five grid resolutions are 2578492, 4138274, 5963514, 7256713 and 9331467. After reaching computational steady state, the air temperature values at the six locations remained essentially consistent across all six grid configurations exceeding 5 million cells. The relative error between results from different grid sizes was less than 2%. Therefore, to optimize computational efficiency, the 5,963,514-cell grid was selected as the computational grid for this study.

Data Measurement

To validate the accuracy of the Fluent model, field data must be collected and compared with simulation data. Environmental measurements utilize a proprietary wireless sensor network system, with a Siemens PLC (S7-200 smart) serving as the control core. Employing the Modbus-RTU communication protocol, LoRa wireless transparent transmission modules connect to temperature sensors, humidity sensors, and air velocity sensors to form measurement nodes, as shown in Fig. 5.

Fig. 5.

Fig 5 dummy alt text

Sensor node diagram.

The specific parameters of the sensors used in the experiment are shown in Table 3.

Table 3.

Sensor parameter table.

Category Range Accuracy Model
Temperature/°C -40∼120 ±0.4 RS-WS-N01
Relative humidity/% 0∼100 ±3 RS-WS-N02
Air velocity/m/s 0∼60 ±(0.2±0.02*v) RS-WS-H01

To validate the accuracy of this numerical model, measurements were taken at two heights: (1) the activity height of the first layer of chickens (0.8 m), this height is within the primary activity range of chickens, directly reflecting the temperature, humidity, and wind speed in their breathing zone. Comparing the measured data at this height with simulation results provides the most accurate assessment of the model's precision in simulating core biological environments; and (2) the midpoint height of the second and third layers of chicken cages (2 m), Significant interference from the cage and chickens is present here, and the measured data effectively reflects the accuracy of the porous medium model in simulating actual complex flow. Measurement point information is shown in Table 4.

Table 4.

Survey Point Information Table.

Number Coordinate axes
x y z
1 10 0.8 5
2 10 0.8 10
3 50 0.8 5
4 50 0.8 10
5 90 0.8 5
6 90 0.8 10
7 10 2 5
8 10 2 10
9 50 2 5
10 50 2 10
11 90 2 5
12 90 2 10

Model validation

Temperature, relative humidity, and air velocity results from 12 measurement points were compared with the numerical calculation results. Relative error was used as the verification criterion. The relative error equation is as follows:

Eb=(XCFD−XEXPXEXP)×100% (3)

Where, Eb represents the relative error, XCFD denotes the CFD simulation value, and XEXP indicates the actual measured value.

The comparison results are shown in Fig. 6.

Fig. 6.

Fig 6 dummy alt text

Error between simulated and measured values (a) Temperature error (b) Relative humidity error (c) Air velocity.

Comparison results between CFD simulation values and actual measurements at 12 data points show that air temperature errors remained below 5% across all locations. The largest temperature error occurred at the air inlet, with a maximum deviation of 1.14°C. This was attributed to external cold air entering the laying hen house at high velocity under negative pressure conditions, leading to significant measurement inaccuracies. Relative humidity errors were consistently below 8%, falling within an acceptable range. Air velocity values are typically small, and using relative error comparisons may fail to accurately describe actual physical phenomena. Air velocity errors generally remain below 0.3 m/s, demonstrating that the model accurately reflects real-world conditions. Measured air velocities are consistently lower than simulated values, indicating that feeding systems, watering systems, and egg collection systems exert minor obstructing effects on air velocity. However, these effects are negligible in simulation.

Area-weighted uniformity index

This study optimized vertical airflow distribution by controlling the angle of the deflector plate, focusing on the core driving factor—the static pressure gradient dominated by temperature stratification and fan negative pressure. This factor exhibits the most pronounced vertical variation and determines the air intake distribution across each layer. Horizontal and longitudinal uniformity are more influenced by poultry house structure, obstacle layout, and the uniformity of the incoming airflow.

The area-weighted uniformity index is used to quantify the uniformity of airflow velocity distribution across four distinct height levels in the vertical plane of the chicken house activity zone. Values closer to 1 indicate higher uniformity. The calculation equation 4 is shown below:

AU=1−∑i=1n|vi−v¯A|·Ai2·v¯A·∑i=1nAi (4)

Where, AU represents the area-weighted uniformity index, v denotes the air velocity value of the unit, and A represents the area represented by the unit.

Results and discussion

Effect of air deflector angle on air velocity

Effect of air deflector angle on airflow path

In the post-processing of Fluent simulation analyses for poultry house ventilation systems, wind speed vector plots serve as a visual tool for intuitively displaying indoor airflow patterns. By plotting arrows with direction (vector) and length (magnitude) at computational grid points, these plots simultaneously characterize both the wind speed magnitude and flow direction at any point within the flow field.

Analysis of the longitudinal section velocity vector Fig. 7 for the poultry house at six different deflector plate angles ranging from 15° to 90° clearly reveals the significant impact of the tilt angle on the airflow organization, velocity distribution, and ventilation efficiency within the house.

Fig. 7.

Fig 7 dummy alt text

Air velocity vector diagram for the X=85.495m axis section.

Changes in the angle of the deflector plate directly alter the direction and momentum of the incoming airflow. At small angles (15°–30°), the airflow enters the house nearly horizontally with high initial momentum, forming a jet stream with strong penetration capability that reaches the far end of the poultry house. However, as the angle increases to 45°–60°, the upward trajectory of the airflow becomes pronounced. This occurs because the intake angle tilts more upward, amplifying the thermal pressure effect. When the angle further increases to 75°–90° (vertical), the airflow ascends almost immediately upon entry. A distinct recirculation zone or vortex forms near the inlet, significantly reducing penetration distance and causing stagnation in most areas. The maximum wind speed under all operating conditions occurs near the inlet of the guide vane. At small angles (15°–30°), medium-to-high-speed airflow is distributed more broadly throughout the entire poultry house, facilitating uniform longitudinal airflow. In contrast, at large angles (75°–90°), high-velocity zones are confined to a narrow area above the inlet. Most areas within the house become low-velocity zones, with wind speeds generally below 2.8 m/s. This significantly increases the area of ventilation dead zones and reduces uniformity. Ventilation efficiency depends on the coverage of fresh air and the rate of pollutant removal. The “sweeping airflow” generated by low-angle intake effectively removes heat, moisture, and harmful gases accumulated at poultry height levels, achieving high ventilation efficiency. While high-angle intake avoids direct airflow impact on the flock, it causes severe airflow short-circuiting and dead zones. This leads to stagnant, contaminated air accumulating heat and moisture in the lower barn sections, preventing effective comprehensive ventilation. This poses particularly high risks during summer conditions of high temperature and humidity.

Correlation analysis of simulation parameters

The objective of the ventilation system is to provide a comfortable and stable indoor environment, where various environmental parameters are interrelated and mutually influence each other. To analyze the correlations among simulation parameters in Fluent, 12,000 sets of data were recorded for the chicken cage area when the deflector plate was inclined at 15°, including: Thermal-Humidity Index (THI), Effective Temperature (ET), Pressure, Wind Speed, Vorticity, Turbulence Intensity, Temperature, Relative Humidity, and Air Age.

THI=(1.8×Tdb+32)−[(0.55−0.0055RH)×(1.8Tdb−26)] (5)
ET=THI−[0.13(42−Tdb)(v0.7−0.20.7)×1.8+32] (6)

Where, THI represents the temperature-humidity index; Tdb denotes the dry-bulb air temperature, °C; RH indicates the relative humidity of the air, %; ET signifies the effective temperature for laying hens, ℉; and v represents the airflow velocity, m/s.

The results of the correlation analysis are shown in Fig. 8.

Fig. 8.

Fig 8 dummy alt text

Correlation results of simulation parameters.

According to the correlation heatmap analysis, the temperature-humidity index, effective temperature, and air temperature all exhibit extremely strong positive correlations with correlation coefficients >0.93, indicating that temperature is the dominant factor influencing heat sensation in laying hens. Pressure shows strong negative correlations with the temperature-humidity index and effective temperature, while exhibiting positive correlations with wind speed and turbulence intensity, demonstrating that pressure distribution directly impacts aerodynamic characteristics. Wind speed exhibits the expected strong negative correlation with air age, with a correlation coefficient of -0.89, validating the fundamental principle that increasing wind speed effectively reduces air age and improves air freshness. Simultaneously, wind speed also shows negative correlations with the temperature-humidity index and effective temperature, further confirming that appropriate wind speeds help alleviate heat stress. Turbulence intensity showed positive correlations with pressure and wind speed, while exhibiting negative correlations with temperature and humidity. This indicates that enhancing turbulence promotes heat and moisture exchange and uniform distribution. Overall, optimizing the deflector plate angle should focus on balancing the relationships between wind speed, turbulence intensity, temperature, and air age to reduce thermal sensation while improving ventilation efficiency and uniformity.

Effect of air deflector angle on inlet air velocity

Fig. 9 illustrates the variation in air velocity and mass flow rate across six intake ports under different deflector plate inclination angles. Air velocities at intake ports positioned at the same height on both ends of the side wall remain largely consistent. As the deflector plate inclination gradually increases from 15° to 90°, the overall air velocity at all inlets exhibited a decreasing trend. A particularly significant reduction occurred when the angle increased from 15° to 30°, with the air velocity at Inlet 1 dropping from 10.33 m/s to 5.74 m/s—a decrease of 44.43%. This indicates that a smaller deflector plate opening angle tends to generate higher inlet air velocity. As the angle further increased to 45° and beyond, the decline in air velocity gradually flattened, eventually stabilizing at 90°. Air velocities across all inlets clustered within the 2.7–3.0 m/s range, reflecting a state where airflow becomes more uniform at high inclinations but overall velocities remain low. Changes in inlet air velocity correlate with the guide vane's role in directing and obstructing airflow. Under steady-state conditions, with constant mass flow rate at the fan inlet, a smaller guide vane tilt reduces the inlet area, favoring high-velocity airflow formation. Conversely, a larger tilt increases the inlet area, correspondingly reducing inlet air velocity. Although air velocity decreases with increasing angle, the velocity differences between inlets diminish at larger angles, indicating that higher deflector angles contribute to more uniform air distribution. Furthermore, Fig. 9c shows that mass flow rate data does not exhibit a strictly monotonic change parallel to air velocity, suggesting that factors beyond wind speed—such as flow structure and inlet area—also collectively influence ventilation efficiency. The deflector plate tilt angle is a key parameter influencing inlet air velocity. Properly setting this angle can achieve a balance between air velocity and uniformity.

Fig. 9.

Fig 9 dummy alt text

Changes in inlet physical quantities: (a) Air velocity at inlet on side wall A; (b) Air velocity at inlet on side wall B; (c) Mass flow rate at inlet.

Effect of air deflector angle on air velocity and pressure environment in the house

Fig. 10a shows the variation in maximum air velocity within the cage area and the pressure range within the laying house at different air deflector angles. Fig. 10b displays the volume percentage distribution across different air velocity ranges. As the air deflector tilt angle increased from 15° to 90°, the maximum air velocity in the cage area exhibited a significant decreasing trend, dropping from 7.7 m/s to 3.48 m/s. This indicates that increasing the tilt angle effectively reduces extreme air velocities within the house.

Fig. 10.

Fig 10 dummy alt text

Air velocity in laying hen house: (a) Maximum air velocity and pressure conditions in the cage area; (b) Proportion of air velocity volume across different ranges in the cage area.

The requirements for air velocity ranges in aquaculture environments are shown in Table 5 (Xie et al., 2024). Regarding air velocity distribution, the proportion of the optimal air velocity range (0.5–2.0 m/s) increases initially and then slows as the angle increases. At 30°, the proportion of optimal air velocity reaches 89.60%, and remains above 88.10% for angles greater than 30°. When wind speeds exceed 2.5 m/s, it significantly increases effective heat dissipation from the chickens' body surfaces. This not only impacts production but also stirs up dust and other hazards within the house, posing risks to the chickens' health, the proportion of higher air speeds exceeding 2.5 m/s steadily decreased from 1.43% at 15° to 0.06% at 90°, indicating that increasing the deflector plate angle effectively suppresses the generation of localized high-speed airflow, thereby reducing adverse stimulation to the chickens. Regarding pressure conditions, the overall pressure range within the house shifted upward with increasing tilt angle, gradually changing from -60 to -39 Pa at 15° to -15 to 2 Pa at 90°. In negative pressure ventilation systems, fans expel air from the laying house, creating internal pressure lower than external pressure to draw fresh air through intake vents. Static pressure serves as a key indicator of system resistance. Higher negative pressure values indicate greater system resistance and faster air intake velocity. When the intake opening is at 15°, the smaller intake area creates greater resistance to air entering the house. To maintain the fan's rated exhaust volume, the system requires a higher pressure differential to drive airflow, resulting in greater negative pressure inside the house. As the inlet opening angle increases, the intake area expands and airflow resistance decreases. The system requires a smaller pressure differential to achieve the same exhaust volume, consequently reducing the negative pressure inside the poultry house. A significant decrease in absolute negative pressure indicates reduced ventilation resistance, resulting in a smoother overall airflow pattern that enhances environmental stability.

Table 5.

Air velocity requirements for aquaculture environments.

Environmental factor Suitable Normal Poor
Air velocity (m/s) 0.5∼2.0 >2.0∼3.5 >3.5∼5.0

Analysis of air velocity and pressure variations indicates that the air deflector maintains a high proportion of suitable wind speeds within the 30° to 90° range. Particularly beyond 60°, wind speed distribution within the barn becomes more concentrated, extreme wind speeds are significantly reduced, and air pressure conditions become more moderate. This contributes to creating a stable and comfortable indoor environment. Therefore, in practical applications, adjusting the deflector plate's tilt angle enables effective control of indoor airflow organization. It is recommended to select angles within the 60° to 75° range to achieve a balance between ventilation efficiency and animal welfare. Within this angle range, the fan achieves maximum efficiency, enabling the lowest energy consumption for poultry house ventilation. When the deflector plate angle is less than 60°, the air inlet area decreases, causing excessive static pressure differentials inside the house. The fan must overcome significant resistance, leading to increased power consumption. When the deflector plate opening angle exceeds 75°, the intake opening becomes excessively large. The fan delivers maximum airflow, with air entering through the nearest intake and being expelled directly from the fan without reaching the far end of the poultry house. This creates ventilation dead zones. Although the fan operates at full speed, it fails to achieve effective air exchange and uniform distribution, resulting in excessive energy consumption.

This “optimal angle” conclusion strictly depends on the specific geometry of the chicken house, fan performance, and steady-state conditions targeting maximum ventilation rate in this study. It is not a universal constant. The core value of the model lies in providing a methodological toolkit that allows recalculation of site-specific optimal solutions by adjusting input parameters for different structures, climatic conditions, or optimization objectives.

Effect of air deflector angle on air velocity distribution

Fig. 11 illustrates the air velocity distribution across three coordinate axes, including: tangent planes with x-coordinates of 5.495 meters, 47.495 meters, and 85.495 meters; a tangent plane with a z-coordinate of 7.5 meters; and a tangent plane with a y-coordinate of 2 meters. At a 30° deflector angle, the contour plot reveals distinct high-velocity air channels within the house, exhibiting uneven wind distribution. Certain zones feature elevated wind speeds with strong air penetration, yet prone to generating localized strong winds near the chicken cages. As the angle increases to 45° and 60°, the high-velocity flow zones gradually diminish, the airflow distribution becomes more uniform, and the wind speed gradient flattens. This indicates that increasing the tilt angle effectively promotes airflow diffusion and mixing while reducing direct impact currents. When the angle further increased to 75° and 90°, the wind speed distribution map exhibited a more uniform color gradient transition. The overall air velocity level significantly decreased, with high-speed zones largely disappearing. Air speeds in most areas fell within the appropriate range, forming a stable airflow field. The deflector plate's inclination plays a pivotal role in regulating airflow patterns. At smaller angles, the plate strongly directs airflow, resulting in concentrated flow and higher velocities. As the angle increases, the plate's blocking and dispersing effects intensify, distributing incoming air more uniformly throughout the space. This effectively prevents localized areas of excessively high or low air speeds. Comprehensive cloud map analysis indicates that deflector angles between 75° and 90° achieve optimal air velocity uniformity within the house. This range minimizes zones with unsuitable air speeds, providing poultry with a stable ventilation environment. This is significant for improving animal welfare and enhancing ventilation efficiency.

Fig. 11.

Fig 11 dummy alt text

Air velocity distribution contour map.

Effect of air deflector angle on air velocity uniformity

Fig. 12 displays the air velocity uniformity indices at four height levels (0.7 m, 1.4 m, 2.1 m, 2.8 m) within the house for different air deflector angles. As the deflector angle increased from 15° to 90°, the uniformity indices at each height level generally exhibited a gradual decline followed by stabilization. At 15°, the uniformity index was highest across all levels, indicating optimal airflow distribution uniformity with relatively minor vertical variations. When the angle increased to 30°, the indices for each level dropped significantly to the range of 0.75–0.80, showing a decreasing trend with increasing height. As the angle further increased to 45°–90°, the uniformity indices across all height levels converged within a narrower range of 0.76–0.79. This indicates that within this angle range, the airflow distribution reached a new equilibrium state, though the overall uniformity level decreased compared to the 15° angle. This occurs because the increased deflector angle directs the incoming airflow more vertically, reducing horizontal momentum and thereby diminishing the airflow's diffusion capacity within the house, which affects spatial distribution uniformity. Additionally, while uniformity is relatively lower at larger angles (60°–90°), the differences between layers are minimal, indicating more consistent vertical airflow distribution at these angles.

Fig. 12.

Fig 12 dummy alt text

Air velocity uniformity index at different heights.

Effect of air deflector angle on temperature

Effect of air deflector angle on thermal environment in chicken cage areas

Requirements for temperature ranges in rearing environments are shown in Table 6 (Xie et al., 2024).

Table 6.

Temperature range requirements for rearing environments.

Environmental factor Suitable Normal Poor
Temperature (°C) 26∼28 >28∼30 >30∼32

Fig. 13a records the maximum and minimum temperatures in the chicken cage area corresponding to the air deflector angle increasing from 15° to 90°. As the air deflector opening angle increases, the maximum temperature in the chicken cage area first rises and then slightly declines. It gradually increases from 29.9°C at 15° to 31.62°C at 75°, slightly decreasing to 30.95°C at 90°, with all values exceeding 30°C. The minimum temperature exhibited a fluctuating downward trend, decreasing from 27.14°C at 15° to 26.23°C at 90°, consistently remaining within the comfortable range of 26-28°C. This pattern indicates that increasing the deflector plate angle elevates overall temperatures in the cage area, particularly reaching a peak at 75°. This correlates closely with changes in airflow organization: as the deflector angle increases, the incoming airflow becomes more vertical, reducing horizontal momentum. This impairs air mixing within the house, causing hot air to accumulate at the top and significantly raising maximum temperatures in the cage zone. In summary, without considering other factors, a smaller deflector plate angle is more conducive to maintaining a suitable thermal environment in the cage area.

Fig. 13.

Fig 13 dummy alt text

Temperature distribution within the laying hen house: (a) Maximum temperature in the cage area; (b) Volume percentage of each temperature range in the cage area.

Fig. 13b records the volume percentage distribution of temperatures within the poultry house under six different deflector plate angles, Define the optimal temperature range for aquaculture as between 26°C and 28°C. At 30°, the suitable temperature range dominates, complemented by a higher proportion of the general temperature range, indicating overall thermal control at this angle. As the angle increased to 45° and 60°, changes in airflow organization reduced ventilation efficiency in some areas. Both the mixing of external cold air and internal warm air decreased, leading to a significant increase in the volume proportion of the poor temperature zone and a corresponding decrease in the suitable temperature zone, resulting in a noticeable decline in thermal environment quality. As the angle further increases to 75° and 90°, the proportion of the unfavorable temperature zone declines while the proportion of the suitable temperature zone increases. This stems from altered airflow distribution patterns at greater inclination angles, enhancing air mixing and heat diffusion in the cage areas. However, the overall thermal environment remains inferior to the optimal state achieved at 30°.

Fig. 14 records the temperature variation curves at four height levels (0.7 m, 1.4 m, 2.1 m, 2.8 m) along the centerline of the chicken flock activity zone. The x-axis represents the axial distance within the chicken house, with the cage area spanning from x=9 m to x=90 m. This data originates from six experiments conducted with different deflector plate tilt angles. As shown in Fig. 14, from the deflector plate toward the fan end, the temperature curves at each height level exhibit varying degrees of upward trends, with the most significant temperature increases occurring at the mid-to-high levels (2.1m and 2.8m). At a 15° tilt angle, the temperature curves across all levels were the most gradual, with most values falling within the optimal range of 26–28°C. The vertical temperature difference was minimal, indicating the best thermal environment uniformity. As the angle increased to 30° and 45°, the temperature curves began to show noticeable fluctuations. At the 2.8m height, temperatures generally exceeded 28°C, entering the moderate temperature range, while the temperature difference between the bottom and top levels gradually widened. Further increasing the angle to 60° and 75° intensifies thermal stratification. Upper-level temperatures consistently exceed 30°C, entering a poor temperature range and forming a pronounced vertical temperature gradient. This indicates that larger inclination angles cause hot air to accumulate at the top, reducing ventilation efficiency. At a 60° angle, the airflow entering through the deflector plate converges in the air. The low-temperature air disperses irregularly in all directions, resulting in significant longitudinal temperature fluctuations. As the angle increases, overall temperature levels rise, thermal stratification worsens, and high-temperature zones expand significantly. The angle of the air deflector directly influences the temperature distribution characteristics within the house by altering the airflow structure and mixing efficiency.

Fig. 14.

Fig 14 dummy alt text

Temperature distribution map along the centerline at different heights.

Effect of deflector angle on temperature distribution

Fig. 15 shows the temperature distribution contour maps obtained from six experiments with different deflector angles. The color scale distribution and contour line patterns reveal that the most uniform temperature field occurs at a 15° deflector angle. The overall color transition is smooth, with the smallest high-temperature zone concentrated primarily in the upper region. The majority of the middle and lower layers where the flock resides remain within the optimal temperature range, indicating that the ventilation airflow effectively dissipates heat from the house and achieves good thermal environment control. As the angle increases to 30° and 45°, the map shows expanding high-temperature zones and localized distortion of isotherms. Significant temperature rises appear particularly in the rear and upper sections of the house, with initial signs of thermal stratification emerging. This indicates reduced airflow organization efficiency and localized heat accumulation in certain areas. As the angle further increased to 60° and 75°, the temperature distribution cloud map underwent significant changes. The high-temperature zone expanded markedly, with warm-colored areas extending downward from the top. The isotherm distribution became more complex, and the vertical temperature gradient intensified. The upper and middle tiers of the chicken cages generally entered a poorer temperature range, reflecting a significant weakening of the ventilation airflow's heat removal capacity and inadequate air mixing. At 90°, although the high-temperature zone slightly contracted, overall temperature levels remained elevated, and temperature distribution uniformity showed no significant improvement. The increased deflector angle heightened the vertical component of the inflow momentum while reducing horizontal penetration, diminishing the airflow's ability to agitate and mix the house air. This simultaneously altered the internal pressure distribution and flow field structure, thereby impacting heat exchange efficiency.

Fig. 15.

Fig 15 dummy alt text

Temperature distribution cloud map.

Theoretical model development

Theoretical model

This study developed a theoretical model to describe the mathematical relationship between the deflector plate tilt angle and the total ventilation volume of the system, as well as the mass flow rate of each deflector plate. Adjusting the deflector plate tilt angle alters the pressure environment within the laying hen house. Since fan performance is closely tied to this pressure environment, the hen house space can be conceptualized as a large air control unit. The power source is the negative pressure fan installed at the rear end of the hen house, with a total exhaust airflow of Vtotal. The air inlets are the six deflector plates installed at the front end.

Assumptions:

After ventilation stabilizes, the internal airflow within the poultry house is steady-state flow, and all measured parameters remain constant over time.

The indoor air is treated as an incompressible fluid with constant density ρ.

The external pressure of the poultry house is P0, and the density is uniform.

The internal static pressure field is non-uniform. Static pressure Pr(zj) within the poultry house is a function of the static pressure at the jth deflector plate at height zj.

Each deflector plate is treated as a thin-walled structure, with its mass flow rate determined by the driving pressure difference, effective opening area, and flow coefficient.

For the flow model of the jth guide vane installed at height zj, its driving pressure difference is given by Equation 7.

ΔPj=P0−Pr(zj) (7)

Where, ΔPj represents the driving pressure difference of the jth air guide plate, Pa; P0 denotes the external pressure of the poultry house, Pa; Pr(zj) signifies the static pressure of the jth air guide plate at height zj.

The effective ventilation area of the air guide plate is calculated as shown in Equation 8.

Aθ=Amaxsinθ (8)

Where, Aθ represents the effective ventilation area of the air guide plate, m2; Amax denotes the maximum physical area of the air guide plate, m2; θ indicates the tilt angle of the air guide plate.

According to Bernoulli's equation, the static pressure environment at both ends of the air guide plate j can be expressed as Equation 9.

P0=Pr(zj)+12ρvj2 (9)

Where, ρ represents the air density inside the shed, kg/m³ (1.18 kg/m³, 299.15 K); vj represents the air velocity at the inlet of air guide plate j, m/s.

From Equation 9, the air velocity at the inlet of guide vane j can be obtained, leading to Equation 5.

vj=2(P0−Pr(zj))ρ (10)

Based on Bernoulli's principle and the flow coefficient, the volumetric flow rate at standard conditions of the guide vane can be calculated using Equation 11.

Vj=CdAθ2ΔPjρ (11)

Where, Vj represents the volumetric flow rate at standard conditions of the guide vane, m³/s; Cd denotes the flow coefficient of the guide vane (dimensionless), which is related to the geometric shape and flow characteristics of the guide vane. For the specific baffle plate structure in this study, the flow coefficient was obtained using an experimental calibration method. By varying multiple tilt angles and calculating the driving pressure difference, the Cd flow coefficient for six sets of baffle plates was determined to range between 0.62 and 0.68. At small deflector plate angles, the airflow experiences significant guidance and obstruction, resulting in pronounced flow separation. Though the effective flow area is small, the streamlines are curved, and Cd is typically low. At medium angles, the airflow guidance is effective, and the contraction section remains stable. At this point, Cd usually reaches its maximum value and remains relatively stable. At large angles, the structure approaches that of a simple orifice, where edge effects may induce slight vortices, causing Cd to drop slightly below its maximum value.In negative-pressure ventilation systems for poultry houses, inlet air velocities typically exceed 1–3 m/s, corresponding to a very high Re value (far exceeding the critical turbulent Reynolds number). The flow resides in the self-smoothing region, allowing Cd to be treated as a constant independent of Re.

The mass flow rate is calculated as per Equation 12.

mj=ρVj=CdAθ2ρΔPj (12)

Where, mj represents the mass flow rate of air deflector j, kg/s.

Due to temperature stratification and airflow organization characteristics, the static pressure within the house varies with height. A linear model is employed to simplify the internal static pressure field model of the laying hen house (Equation 13).

Pr(z)=Pr(0)+dPrdzz (13)

Where, Pr(0) represents the static pressure inside the shed at ground level (z=0), Pa; dPr/dz denotes the vertical gradient of static pressure, Pa/m. Typically negative, it indicates that static pressure decreases with increasing height.

Substituting (Equation 13) into the driving pressure difference (Equation 7) yields.

ΔPj=P0−Pr(zj)=[P0−Pr(0)]−dPrdzzj (14)

Order ΔPref=P0−Pr(0) to obtain the driving pressure difference at the reference point (ground) (Equation 15).

ΔPj=ΔPref−dPrdzzj (15)

According to the principle of mass conservation, under steady-state conditions, the total mass flow rate entering the chicken house equals the total mass flow rate discharged by the fans (Equation 16).

∑j=1Nmj=ρVtotal (16)

Substituting (11), (14) into Equation 16 yields.

∑j=1N[CdAmaxsinθ2ρ(ΔPref−dPrdzzj)]=ρVtotal (17)

The overall performance of the fan is approximated by a linear model as shown in Equation 18.

ΔPref=Pmax−KfVtotal (18)

Where, Pmax represents the maximum static pressure of the fan, Pa; Kf denotes the slope of the fan performance curve, Pa·s/m³, reflecting the fan's ability to overcome system resistance.

Substituting Equation 16 into Equation 18 yields an equation for the single unknown ΔPref, Equation 19.

Pmax−ΔPrefKf−CdAmaxsinθρ∑j=1N2(ΔPref−dPrdzzj)=0 (19)

The iterative numerical calculation method is employed to compute ΔPref, which is used to estimate the mass flow rate and total ventilation volume.

Model Validation

To ensure the reliability of the theoretical model, we validated its accuracy by comparing experimental data with numerical simulation results under different deflector plate inclination angles. We calculate the mass flow rate at the intake port by measuring the air velocity at the intake port of the deflector plate, combined with air density and intake area (Mass flow rate = Air velocity × Air density × Intake area). The validation parameters of the numerical model were fully consistent with the experimental system.

Based on the model proposed, the mean relative error (MRE) between the predicted mass flow rate and experimental values was consistently below 9.49%. Fig. 16 presents the comparison data between experimental and predicted values. The theoretical model exhibits minimal prediction errors for mass flow rate, indicating good agreement between model predictions and experimental data. Beyond this, discrepancies between predicted and experimentally measured mass flow rates primarily stem from external natural airflow fluctuations and systematic errors. Due to airflow organization and the presence of obstacles, the static pressure field may exhibit nonlinear behavior, directly contributing to calculation errors in the driving pressure differences across each guide vane.

Fig. 16.

Fig 16 dummy alt text

Comparative Analysis of Experimental and Theoretical Outlet Mass Flow Rates in Ventilation Systems.

Application Analysis

This theoretical model can be applied to inverse design and real-time control. In inverse design, target ventilation rates and uniformity requirements can be set as constraints. By utilizing model inversion to solve for the optimal combination of deflector plate angles, it provides quantitative basis for system design. In real-time control, the model can be embedded into controllers. Through real-time monitoring of barn pressure or partial flow rates, angle setpoints can be rapidly updated through iterative adjustments, enabling precise ventilation regulation in dynamic environments.

Before designing the theoretical model, we made idealized assumptions about the entire ventilation system, resulting in limitations to the model's applicability. The steady-state assumption means the model only applies to stable operating conditions and cannot predict dynamic transients during fan start-up, shutdown, or angle adjustments, ignoring all time-dependent fluctuating effects. Assuming air is incompressible and of constant density neglects thermal pressure effects caused by temperature differences. When significant indoor-outdoor temperature differentials exist, this systematically overestimates or underestimates ventilation flow rates. The uniform external pressure assumption validates the model only under conditions of no natural wind or light breezes. Actual wind pressure significantly alters the driving pressure differentials across each guide vane, constituting a primary source of prediction error. While acknowledging non-uniform internal static pressure and pressure stratification represents a key advancement, reliance on subsequent linear simplified models introduces computational bias if actual static pressure distribution exhibits nonlinearity. Treating the guide vane as a thin-walled orifice allows application of the classical flow formula. However, the flow coefficient requires experimental calibration, limiting the model's universality to guide vanes with specific geometric configurations.

Furthermore, the model exhibits limitations due to the omission of critical environmental factors. External meteorological conditions, including wind speed, wind direction, temperature, and solar radiation, significantly influence air intake characteristics and indoor environments. Particularly in side-wall air-guiding panel systems, the model assumes uniform and constant external pressure, which diverges from real-world operational conditions.

Conclusion

This study systematically investigated the impact of deflector plate tilt angles (15°–90°) on the performance of ventilation systems in laying hen houses through a combination of experiments and numerical simulations, and proposed a formula for calculating ventilation performance. The following conclusions were drawn:

  • (1)

    At a constant exhaust fan mass flow rate, increasing the deflector plate inclination angle at the air inlet (within the 15°–90° range) enlarges the air intake area, thereby reducing inlet air velocity. A smaller deflector plate angle results in higher indoor air velocity, greater air velocity uniformity, improved cooling efficiency, and larger proportions of the indoor air velocity comfort zone and thermal comfort zone.

  • (2)

    When the deflector plate angle is less than 60°, the maximum air velocity and pressure conditions in the chicken activity zone exceed the suitable farming range. During hot weather when multiple fans are operating, the deflector plate angle must exceed 60° to ensure comfort in the chicken activity zone.

  • (3)

    A theoretical model was established to predict the mass flow rate at the outlet under different tilt angles. The mean root mean square error (MRE) between predicted and measured values was consistently below 9.49%. The model's predictions showed high agreement with experimental data, providing technical guidance for optimizing ventilation system designs in practical applications.

The above findings reveal the influence patterns of air deflector tilt angle on indoor environmental regulation, further validating the importance of intake vent design in egg-laying hen house ventilation systems. A limitation of this study is that its results were validated under traditional negative-pressure building configurations, lacking debate verification for more diverse ventilation structures (e.g., the ventilation pattern proposed by Tong et al., where exhaust fans are installed on perimeter walls and intake vents are positioned on the hen house roof (Tong et al., 2019b)). Future research may explore the influence of intake air guide plate inclination angles on regulating environmental parameters under various ventilation configurations.

Funding

This project was funded by the National Natural Science Foundation of China (Grant No. 32573279), Hebei Agriculture Research System (HBCT2024260203) (HBCT2024270208), the Talents Introduction Plan of Hebei Agricultural University under Grant (YJ2023049), the research project on Basic Research Business Expenses of Provincial Higher Education Institutions in Hebei Province (KY2024008), Hebei Provincial Natural Science Foundation(C2025204036), the research project on Basic Research Business Expenses of Provincial Higher Education Institutions in Hebei Province (KY2024009), Scientific Research Plan Projects for Higher Schools in Hebei Province -Youth Elite Talent Program (BJ2025062).

Institutional review board statement

Not applicable.

Informed consent statement

Not applicable.

Data availability statement

The data of this study are available from the corresponding author.

CRediT authorship contribution statement

Changzeng Hu: Writing – review & editing, Writing – original draft, Visualization, Validation, Software, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Zongkui Xie: Writing – review & editing, Funding acquisition. Yuchen Jia: Writing – review & editing, Resources, Project administration, Investigation, Funding acquisition. Hao Xue: Writing – review & editing, Funding acquisition. Lihua Li: Writing – review & editing, Supervision, Resources, Project administration, Methodology, Funding acquisition, Conceptualization. Limin Huo: Writing – review & editing, Supervision.

Disclosures

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgments

The author is very grateful to all the staff of the Key Laboratory of Broilern Breeding Facilities Engineering of the Ministry of Agriculture and Rural Affairs and the laying hen breeding enterprises.

References

  1. Cheng Q., Li H., Rong L., Feng X., Zhang G., Li B. Using CFD to assess the influence of ceiling deflector design on airflow distribution in hen house with tunnel ventilation. Comput. Electron. Agric. 2018;151:165–174. [Google Scholar]
  2. Deng S., Li Z., Wei Y., Wang Y., Li B., Zheng W. Assessing temperature distribution inside commercial stacked cage broiler houses in winter. Animals. 2024;14:2638. doi: 10.3390/ani14182638. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Du L., Yang C., Dominy R., Yang L., Hu C., Du H., Li Q., Yu C., Xie L., Jiang X. Computational Fluid dynamics aided investigation and optimization of a tunnel-ventilated poultry house in China. Comput. Electron. Agric. 2019;159:1–15. [Google Scholar]
  4. Du L., Yang L., Yang C., Dominy R., Hu C., Du H., Li Q., Yu C., Xie L., Jiang X. Investigation of bio-aerosol dispersion in a tunnel-ventilated poultry house. Comput. Electron. Agric. 2019;167 [Google Scholar]
  5. Dussiot A., Fouillet H., Perraud E., Salomé M., Huneau J.F., Mariotti F., Kesse-Guyot E. How to best reshape diets to be healthier with lower or no ruminant meat, and implications for environmental pressures. J. Clean. Prod. 2023;414 [Google Scholar]
  6. Fidaros D., Baxevanou C., Bartzanas T., Kittas C. Numerical study of mechanically ventilated broiler house equipped with evaporative pads. Comput. Electron. Agric. 2018;149:101–109. [Google Scholar]
  7. Hu C., Li L., Jia Y., Xie Z., Yu Y., Huo L. CFD investigation on combined ventilation system for multilayer-caged-laying hen houses. Animals. 2024;14:2623. doi: 10.3390/ani14172623. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Khattri S.K., Log T., Kraaijeveld A. A novel representation of the critical ventilation velocity for mitigating tunnel fires. Tunnell. Underground Space Technol. 2021;112 [Google Scholar]
  9. Li D., Tian P., Sun Y., Yang D., Su Y., Ma Y., Tian J., Zhang W., Li Y. Accounting carbon emission in the layer breeding industry of North China. Trans. Chin. Soc. Agri. Eng. 2024;40:193–201. [Google Scholar]
  10. Ma H., Tu Y., Yang X., Yang Z., Liang C. Influence of tunnel ventilation on the indoor thermal environment of a poultry building in winter. Build. Environ. 2022;223 [Google Scholar]
  11. Marques Da Silva F., Gomes M.G., Rodrigues A.M. Measuring and estimating airflow in naturally ventilated double skin facades. Build. Environ. 2015;87:292–301. [Google Scholar]
  12. Ni J.Q. Measuring and modeling mechanical ventilation for long-term environmental monitoring in large commercial laying hen house. Animals. 2024;14:3339. doi: 10.3390/ani14223339. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Rojano F., Bournet P.E., Hassouna M., Robin P., Kacira M., Choi C.Y. Computational modelling of thermal and humidity gradients for a naturally ventilated poultry house. Biosyst. Eng. 2016;151:273–285. [Google Scholar]
  14. Tao Y., Fang X., Setunge S., Tu J., Liu J., Shi L. Naturally ventilated double-skin façade with adjustable louvers. Solar Energy. 2021;225:33–43. [Google Scholar]
  15. Tong X., Hong S.W., Zhao L. Using CFD simulations to develop an upward airflow displacement ventilation system for manure-belt layer houses to improve the indoor environment. Biosyst. Eng. 2019;178:294–308. [Google Scholar]
  16. Tong X., Hong S.W., Zhao L. CFD modeling of airflow, thermal environment, and ammonia concentration distribution in a commercial manure-belt layer house with mixed ventilation systems. Comput. Electron. Agric. 2019;162:281–299. [Google Scholar]
  17. Tong X., Zhao L., Heber A.J., Ni J.Q. Development of a farm-scale, quasi-mechanistic model to estimate ammonia emissions from commercial manure-belt layer houses. Biosyst. Eng. 2020;196:67–87. [Google Scholar]
  18. Tu H., Zhu D., Liu M., Liu C., Wang R., Jing Y. Winter temperature control strategy of greenhouse based on heat balance equation. Trans. Chin. Soc. Agri. Eng. 2022;38:200–207. [Google Scholar]
  19. Wang Y., Chen Y., Zhou J. Dynamic modeling of the ventilated double skin façade in hot summer and cold winter zone in China. Build. Environ. 2016;106:365–377. [Google Scholar]
  20. Xie M., Li H., Zhan K. Evaluating the environmental quality of layer house in summer based on multivariate data and its impact on production performance. Trans. Chin. Soc. Agri. Eng. 2024;40:188–197. [Google Scholar]
  21. Yang Z., Tu Y., Ma H., Yang X., Liang C. Numerical simulation of a novel double-duct ventilation system in poultry buildings under the winter condition. Build. Environ. 2022;207 [Google Scholar]
  22. Zhao X., Song Y., Huang L., Song Z., Dong Q., Qi J., Shi L. Controlling double-skin façades with inclined louvers for natural ventilation: an experimental and theoretical study. Appl. Energy. 2025;377 [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data of this study are available from the corresponding author.


Articles from Poultry Science are provided here courtesy of Elsevier

RESOURCES