Table 2.
Results from repeated measures (RM) ANOVAs.
| CAP | Main effects | Interaction effects | Between pair analysis | ||||
|---|---|---|---|---|---|---|---|
| 0.25–16 kHz | 0.25–16 kHz | 0.25–16 kHz | |||||
| Electrodea | Frequencyb | Frequency × Electrodeb | El_Ap vs. El_Bs | El_Ap vs. El_Ex | El_Bs vs. El_Ex | ||
| Threshold | F | 5.66 (2) | 3.14 (2.63) | 2.72 (3.60) | — | — | — |
| P | 0.02* | 0.07 | 0.07 | 0.03* | 0.02* | 0.45 | |
| Amplitude | F | 10.13 (2) | 12.46 (1.94) | 1.79 (3.42) | — | — | — |
| P | 0.004* | 0.002* | 0.18 | 0.02* | 0.002* | 0.23 | |
CAP, compound action potential; El_Ap, apical intracochlear electrode; El_Bs, basal intracochlear electrode; El_Ex, extracochlear electrode.
Sphericity assumed.
Greenhouse-Geisser corrected.
Degrees of freedom (df) given in brackets, p, p-value, with 0.05 significance level*.