Abstract
Unsatisfactory eyebrow permanent make-up (PMU) may negatively affect the well-being of patients. The aim of this study was to objectively assess the effectiveness of removing eyebrow PMU using laser or laser combined with chemical remover. It also analysed colour-related predictors of effective removal of permanent make-up. The study involved 75 patients (mean age 42.8 ± 10 years) who underwent eyebrow PMU removal using laser or laser and chemical remover. Standardised photographs were taken before and after completion of the therapy. Quantitative digital image analysis (DIA) of colour changes within the RGB and HSV and L colour spaces was performed for pre- and postprocedural colour samples from eyebrows. The total change in all the parameters and the total colour distance (ΔD) were calculated. None of the colour parameters correlated with the number of laser sessions required to obtain a satisfactory effect of PMU removal. The receiver-operating characteristic (ROC) curve for the model estimating the probability of the need to use chemical remover (additionally to lasers) showed an acceptable value of area under the curve (AUC = 0.703) for H cut-off value of 15.3. The designed model based on digital image analysis (DIA) of eyebrow PMU colour may serve as a tool for planning a method of PMU removal. The H parameter over cut-off value indicates the need for application of additional chemical remover (laser therapy alone was not effective). However, more variables should be incorporated in the model to prove its clinical utility.
Supplementary Information
The online version contains supplementary material available at 10.1038/s41598-026-38366-1.
Keywords: Laser, Eyebrow permanent make-up, Removal, Digital image analysis (DIA) of colour
Subject terms: Medical research, Optics and photonics
Introduction
Permanent make-up (PMU) is a cosmetic procedure commonly used to improve the appearance of eyebrows, eyelids, or lips by enhancing the desired shape and colour and/or correcting minor defects and asymmetries1. It involves application of exogenous pigments into the papillary layer of the dermis. Although the procedure ensures a long-lasting effect,
its removal is quite challenging2–5. The theory of selective photothermolysis developed by Anderson and Parrish brought a revolution in PMU removal6. According to this concept, laser light of a specific wavelength is selectively absorbed by the target chromophore (the pigment molecule), leading to its thermal destruction with minimal damage to the surrounding tissues. The condition providing effectiveness is the use of a pulse with a duration shorter than or equal to the thermal relaxation time (TRT) of the dye molecule7,8. This discovery paved the way for the development of Q-switched (QS) lasers, emitting ultrashort pulses in the nanosecond (ns) domain, which have become the gold standard for tattoo removal over the past decades9,10. The use of QS lasers (Nd: YAG, ruby, alexandrite) is associated with certain limitations. Their efficiency in pigment removal varies and depends on the colour of the particle. While black and navy-blue pigments are well targeted, colours such as green, yellow or orange pose a significant therapeutic challenge11,12. Additionally, the removal process may require many (from eight to 15) treatment sessions and is also burdened with the risk of side effects such as scarring and permanent hypo- and/or hyperpigmentation13,14. These complications may be related to the phenomenon of paradoxical darkening, which occurs because of the reduction of iron (III) or titanium (IV) oxides, commonly used in red, brown and beige pigments, to their darker, black forms15,16.
In response to these challenges, picosecond (PS) lasers have been introduced, generating pulses with a duration three orders of magnitude shorter than nanosecond lasers (10⁻¹² s vs. 10⁻⁹ s). Such a short pulse allows for the dominant photoacoustic effect, causing rapid fragmentation of dye molecules into smaller particles that can be more effectively removed by the immune system17,18. Clinical studies suggest that picosecond technology may offer higher efficacy, especially in the case of resistant colours, while decreasing the number of sessions required and reducing the risk of complications19,20. However, despite the technological progress, the selection of optimal treatment parameters remains a challenge and requires an objective assessment of both the colour and the chemical composition of the pigment, which is rarely possible in clinical practice21. The effectiveness of therapy still depends on many variables, including the patient’s skin phototype, the depth of pigment implantation and its chemical composition. Therefore, it should be emphasized that the objectivity in the assessment of therapeutic effects needs further research22.
Currently, there are no standardized, objective methods for evaluating the effectiveness of permanent make-up removal that would include quantitative analysis of colour changes. So far, no objective colour parameters have been found that could be useful in estimating the number of laser sessions needed for PMU laser removal and its efficacy, or parameters that could help to predict whether the use of chemical remover is necessary. Therefore, the aim of this study was to objectively assess the effectiveness of removing eyebrow PMU using laser or laser combined with chemical remover. Also analysed colour-related predictors of effective permanent make-up removal were analyzed.
Materials and methods
The study involved 75 patients of a mean age 42.8 ± 10years (age range from 18 to 65 years). The participants were recruited prospectively among patients presenting for eyebrow PMU removal in a private aesthetic medicine clinic between August 2022 and January 2025. The study enrolled women with Fitzpatrick I-III skin types who had permanent make-up performed by a professional, and who completed a full therapeutic cycle of eyebrow PMU removal by one specialist (W.P.). All the subjects gave their informed consent to participate in the study. Exclusion criteria were the following: major complication after any stage of the therapy, pregnancy or planning pregnancy during the study period, active autoimmune diseases, diabetes or other metabolic conditions affecting the healing process, previous attempts to remove PMU of the eyebrows, as well as excessive tanning in the treatment area.
During the first visit, each participant filled out a questionnaire providing their demographic data, medical history and assessing satisfaction with PMU removal according to the ten-point Likert scale (1- not satisfied, 10 – very satisfied). Standardised photographic documentation was also made using the Observ 520x system for skin analysis (Sylton, Netherlands). Two treatment protocols were implemented based on the effect of laser treatment, i.e., laser therapy using a Q-switched laser (X- Lase Plus; Biotec Italia, Poland) (wavelength of 1064 nm, spot size 7–2.5 mm, 1.6–20.4 J/cm2, 6 Hz and wavelength of 532 nm, spot size 4 –2.5 mm, 1.6–16.3 J/cm2, 6 Hz), or combined therapy with laser and an additional chemical pigment removal (Long Time Liner remover - Bye Bye pigment, including sodium hydroxide, with alkaline properties at pH 9.0–11.0) (Suppl. 2). Before using chemical remover, the skin was cleansed with alcohol solution. The remover was inserted into the eyebrow area with controlled punctures using a device commonly used for micropigmentation (Conture®-Liner Duo). Two passages were done per area with the total use of about 0.2 ml of the solution per both eyebrows. After insertion it was left for about 90 s to act on the pigment and then removed with a sterile gauze pad. The number of sessions was adjusted individually until a satisfactory clinical effect was achieved (complete or almost complete removal of pigment). For both protocols, the endpoint was a satisfactory result or no possibility of further improvement. Following accomplishment of the therapy (at least six months after the last treatment procedure), photographic documentation was again made in the same lighting conditions (Observ) (Fig. 1A, B), and each participant was asked to assess their satisfaction from the treatment.
Fig. 1.

(A) Image of eyebrows taken before the treatment (Observ device). (B) Image of eyebrows taken after the treatment (Observ device).
The study was performed in accordance with the Declaration of Helsinki and approved by the Bioethical Committee of the Medical University of Łódź (RNN/173/22/KE). The authors affirm that participants provided informed consent for publication of the images in Figs. 1 and 2.
Fig. 2.
Digital image analysis (DIA) of colour samples from PMU of eyebrows using GIMP software.
Digital image analysis (DIA) of colour
Objective, quantitative colour analysis was performed for all pre- and post-procedural images by a single evaluator (W.P.). From every image of each eyebrow, three representative areas (ROI) were selected manually from the middle of each third of the eyebrow, outside the natural eyebrow (area outside hair) (Fig. 2). For each ROI, the colour components in the RGB and HSV and L colour spaces were measured using GIMP software (version 2.10.32). RGB represents an addictive colour model, in which adding primary red, green and blue creates the array of colours. HSL/V are cylindrical-coordinate representations of points in an RGB colour model, including hue, saturation, and lightness/brightness. Apart from individual analysis of each parameter, changes of all indicators were calculated, namely total change in luminance (ΔL), i.e. the difference in perceived brightness of the pigment before and after treatment, and the total colour distance (ΔD) as the Euclidean difference in the three-dimensional RGB colour space, reflecting the overall colour change.
Statistical analysis
Differences between distribution of variables for the left and the right eyebrows, as well as for pre- and post-procedural values, were determined with the Hellinger’s distance and t test. Further, the authors of the study examined a correlation between colour parameters and the number of laser sessions and the need for application of chemical remover to obtain the endpoint result, using logistic regression. The quality of classifiers was characterised by the area under the receiver operating characteristic (ROC) curve (AUC). Additionally, the optimal cut-off point (OCP) was calculated using Youden index, for which two measures of prediction quality were determined, i.e., sensitivity and specificity. The Youden index is a measure of the quality of a diagnostic test. It helps to select the optimal cut-off point for tests based on a continuous variable to minimize errors in both groups (positive and negative) simultaneously. The value of Youden index closer to 1 indicates better test accuracy, while 0 means that the test is no better than random. Using a calculative tool, it is possible to find a cut-off point that will be most advantageous from a mathematical point of view, which in concept is the maximum distance between the diagonal line of a square with a side length of 1 and a point on the ROC curve. Objective factors correlating with the improvement of patient satisfaction after permanent make-up removal were also identified. Subjective patient satisfaction was taken as the dependent variable, and colour parameters ΔL and ΔD and the type of therapy implemented (laser, remover) were used as predictors. The level of statistical significance was p < 0.05. All statistical analyses were performed using software Statistica 13.3.
Results
Digital image analysis (DIA) of colour left vs. right eyebrow and pre- vs. post-procedural effects
Distribution of the colour parameters differed neither between the right and left eyebrows nor between three independent measurements in three different points (three colour samples), so they were further analysed as a mean value (Table 1). All colour parameters changed after treatment completion (Table 2 and suppl. Table 1).
Table 1.
Hellinger’s distances for colour parameters of the right and left eyebrows and between measurements.
| Variables | R | G | B | H | S | V | L |
|---|---|---|---|---|---|---|---|
| Right vs. Left | 0.078 | 0.085 | 0.081 | 0.391 | 0.087 | 0.030 | 0.027 |
| Measurements 1vs. 2 vs. 3 | 0.068 | 0.074 | 0.063 | 0.400 | 0.135 | 0.065 | 0.058 |
Table 2.
Comparison of pre- and post-procedural colour parameters.
| Mean difference | SD | SE of the mean | 95% CI for difference in means | t | p | ||
|---|---|---|---|---|---|---|---|
| Lower boundary | Upper boundary | ||||||
| B | 10.97 | 7.80 | 0.90 | 9.18 | 12.77 | 12.18 | 0.00 |
| G | 14.24 | 9.92 | 1.15 | 11.96 | 16.52 | 12.43 | 0.00 |
| H | -39.44 | 69.94 | 8.08 | -55.53 | -23.35 | -4.88 | 0.00 |
| L | 15.06 | 6.91 | 0.80 | 13.47 | 16.65 | 18.88 | 0.00 |
| R | 20.13 | 9.90 | 1.14 | 17.85 | 22.41 | 17.60 | 0.00 |
| S | 8.24 | 10.68 | 1.23 | 5.78 | 10.70 | 6.68 | 0.00 |
| V | 19.06 | 8.63 | 1.00 | 17.08 | 21.05 | 19.13 | 0.00 |
t test.
Predictors for the number of laser sessions and the need for using a remover
None of the pre-procedural colour parameters (R, G,B, H,S, V,L) appeared to predict the number of laser sessions needed for achievement of the final effect. However, one of the colour parameters of eyebrows was detected to predict the need for using chemical remover to reach the endpoint. ROC curve for H reached clinical significance with AUC = 0.703 (SE = 0.066, z = 3.1, p = 0.002) for the balance score cut-off value of 15.3 (Fig. 3). At this point the sensitivity amounted to 0.2054, while specificity reached 0.5564. Both the AUC and the Younden index indicated moderate level of accuracy of classification. Its classification level would probably increase with expansion of the sample size.
Fig. 3.
ROC curve for the model predicting the need for using chemical remover based on pre-procedural eyebrow PMU colour H parameter (green line – cut-off value) (AUC = 0.703, 95% CI: 0.57–0.83).
Predictors of patient satisfaction with PMU removal
The mean satisfaction after PMU removal was high (= 9.02) and ranged from four to ten. To identify the predictors of satisfactory results, regression analysis was performed, with the dependent variable being patient satisfaction and other variables introduced into the model, i.e., change in luminance (ΔL), change in colour distance (ΔD), number of laser sessions and application of remover. Eventually, none of the analysed factors (colour parameters, number and type of treatments) proved to be a statistically significant predictor of the final patient satisfaction (R = 0.27, R2 =0.07, corrected R2 = 0.02, F = 1.34, p > 0.05).
Discussion
This study is one of the few that attempts to objectively assess the effectiveness of removal of permanent eyebrow make-up and analyses the factors affecting the subjective satisfaction of patients with achieved results. The most clinically applicable finding is determining a predictor for the need to use chemical remover as a method supplementary to laser, to obtain final, usually satisfactory, results of PMU removal. It was found that one of the parameters of eyebrow PMU colour characteristic, H value over the cut-off point, appeared to indicate the need for chemical remover use. Higher H values may reflect yellow or orange pigment components commonly associated with iron oxides, which are known to respond less favourably to Q-switched lasers. This could be helpful when consulting patients and planning an individual therapy for eyebrow PMU removal. Moreover, our results indicate that none of the colour parameters correlated with patient satisfaction, which confirms that patient perception of therapeutic success does not rely on the visible reduction of unwanted colour only.
Modern laser therapy offers a wide range of tools for removal of exogenous pigments. For decades, Q-switched nanosecond lasers (QS), whose mechanism of action is based on selective photothermolysis, remained the gold standard7,8. Their effectiveness in removing dark pigments, such as black or navy blue, is well documented9,10. Nevertheless, the removal of permanent make-up, especially in the eyebrow area, is particularly challenging. Cosmetic pigments are often complex mixtures of metal (mainly iron) oxides and organic dyes that are expected to provide natural-looking shades of brown and beige15,23. As the literature indicates, it is the presence of iron (III) oxide (red, brown) and titanium (IV) oxide (white) that is the main cause of the paradoxical darkening of the pigment under the impact of the QS laser energy16. Our study, although not focused on this phenomenon, confirms the complexity of interactions between laser light and cosmetic pigments, where the end result is difficult to predict based on visual evaluation alone. The introduction of picosecond (PS) technology has revolutionised the approach to tattoo removal. PS lasers, emitting pulses an order of magnitude shorter than QS lasers, minimise the thermal effect in favour of the dominant photoacoustic phenomenon17,18. Rapid plasma expansion caused by an ultrashort pulse leads to a more efficient fragmentation of pigment particles, which theoretically should translate into faster removal and a lower risk of complications, including thermal damage to the surrounding tissues19,20. Comparative studies confirm the higher effectiveness of picosecond lasers, especially in the removal of resistant-coloured pigments such as green and blue, as well as in reducing the number of therapy sessions needed11,24. Although our methodology did not allow for a direct comparison of the technologies, the very fact that our patients required a different number of sessions to achieve satisfaction emphasises the individual nature of the response to treatment, which is consistent with the literature14. As reported by Alster et al., the presence of melanin in the epidermis is a competing target for laser energy, which can lead to undesirable effects such as hypo- and hyperpigmentation, especially in patients with higher skin phototypes25. For this reason, selection of the appropriate laser wavelength is of key importance. The 1064 nm wavelength (Nd: YAG laser) has a lower absorption in melanin and deeper penetration, making it a safer option for darker complexions12,13. On the other hand, the wavelength of 532 nm, effective in removing red pigments, is more strongly absorbed by melanin and entails a higher risk of pigmentation complications11. In our practice, the choice of treatment protocol was individualised, which being in line with the recommendations of experts, also proves that there is no one-size-fits-all therapeutic regimen26,27. Our results showed that detailed colour analysis of the eyebrow PMU subjected to laser removal may predict the efficiency of the therapy and the need for using an additional method, i.e., chemical remover. It may also be interpreted as laser insufficiency in removing eyebrow PMU with certain H values. The discriminatory power of the above model is, however, moderate as it yields an AUC of 0.703, which limits its clinical utility. It is claimed that models with AUC of more than 0.8 can be clinically applicable, so further studies with larger sample sizes are required to verify the presented model and further improve its accuracy. Additionally, the future designed models should also include other variables (patient related, e.g. skin type and phototype, and other like e.g. pigment type and age, device settings, optical density and pigment depth/dispersion). Moreover, the model was designed based on the use of QS laser so the results may not apply for PS laser, which gains its popularity for PMU and tattoos removal22. Similar study with the use of PS laser should be designed and the results compared with the presented data.
However, none of the colour parameter changes predicted patient subjective satisfaction with the procedure. This may suggest that patients’ expectations and their perception of an aesthetic defect play an equally important, if not even more significant, role than measurable colour changes. Although being a less common reason for undergoing removal procedure than colour, dissatisfaction with the shape of the eyebrows can have a stronger impact on the overall quality of life because the eyebrows play a key role in non-verbal communication and perception of facial attractiveness28. Shape correction, even if it involves a minor change in colour parameters, can bring the patient greater relief and satisfaction. Moreover, in this study we measured patients’ satisfaction after completion of treatment so at the stage when the obtained result was acceptable and final (sometimes after complex therapy with the use of chemical remover). This resulted with the fact that the distribution of satisfaction was not dispersed as most patients were satisfied with the treatment. These factors could have influence the observation about the lack of correlation between the objective color change and satisfaction.
Our study has some limitations. First, the study population was homogeneous in terms of sex and race as well as skin phototypes, which reduced the possibility of generalizing the results to other groups of patients. Second, in most cases there was no information available on the chemical composition of pigments used, which is also a common problem in clinical trials concerning tattoo removal21 and limits full understanding of the mechanisms underlying the observed response to treatment. Nevertheless, this study is one of the first to apply an objective method, i.e., DIA, to evaluate PMU removal outcomes in terms of the number of sessions required for achieving the desirable final effect and the need for implementing an additional removal technique (chemical remover). Our results highlight that pigment lightening is a key, measurable factor that ensures patient satisfaction, however, the ultimate therapeutic success remains a multidimensional phenomenon. This emphasises the need for developing individualised treatment plans, which may include different techniques of PMU removal, and determining predictors for such a complex strategy may prove helpful when discussing the patient’s expected results and planning therapy. However, the model was designed based on a specific lightly pigmented (Fitzpatrick I-III) population, therefore it requires external validation. Also, it would be valuable to verify and validate the model in more diverse populations, with a more varied Fitzpatrick skin types.
Clinical implications
Our preliminary findings indicate that the designed model based on digital image analysis (DIA) of colour of eyebrows qualified for removal procedure (H parameter) has limited clinical utility. However, with moderate accuracy it may be helpful in predicting the need for using additional chemical remover due to laser being not effective. Clinical interpretation of this observation may indicate that PMU colours with more orange or yellow hue, even clinically not visible, may indicate worse effect of laser removal. Future studies including more clinical variables may further improve clinical application of DIA for predicting therapy of PMU removal.
Conclusions
Digital image analysis (DIA) of colour of eyebrows qualified for removal procedure may be helpful in therapy planning and predicting the need for using additional chemical remover. The H parameter appears to predict the need for remover use. However, more variables should be incorporated in the model to prove its clinical utility. Satisfaction from removal of defective permanent eyebrow make-up in Caucasian women with I-III skin phototypes does not correlate with an objective, measurable change in any of the analysed colour parameters. However, the ultimate therapeutic success is a complex phenomenon that depends on individual and psychological factors, not only on the technical parameters of the procedure. Our results emphasise the need for applying objective assessment methods in clinical trials and the importance of developing an individualised treatment plan to meet patient expectations.
Supplementary Information
Below is the link to the electronic supplementary material.
Author contributions
Conception or design of the work: A.K.T., W.P. Data acquisition: W.P. Data analysis: A.K.T., K.K., M.J. Interpretation of data: A.K.T., B.A. Drafting and revising the ms: W.P., A.K.T., B.A., K.K. M.J. All authors have approved the submitted version.
Data availability
on request from the corresponding author (A.K.T. e-mail: anna.kasielska-trojan@umed.lodz.pl).
Declarations
Competing interests
The authors declare no competing interests.
Ethics approval
The study was approved by the Bioethical Committee of the Medical University of Łódź (RNN/173/22/KE).
Patient consent statement
Written consent was obtained from participants.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Ortiz, A. E. & Alster, T. S. Rising concern over cosmetic tattoos. Dermatol. Surg.38, 424–429 (2012). [DOI] [PubMed] [Google Scholar]
- 2.Bernstein, E. F. Laser treatment of tattoos. Clin. Dermatol.24, 43–55 (2006). [DOI] [PubMed] [Google Scholar]
- 3.Sweeney, S. M. Tattoos: a review of tattoo practices and potential treatment options for removal. Curr. Opin. Pediatr.18, 391–395 (2006). [DOI] [PubMed] [Google Scholar]
- 4.Islam, P. S. et al. Medical complications of tattoos: a comprehensive review. Clin. Rev. Allergy Immunol.50, 273–286 (2016). [DOI] [PubMed] [Google Scholar]
- 5.Choudhary, S., Elsaie, M. L., Leiva, A. & Nouri, K. Lasers for tattoo removal: a review. Lasers Med. Sci.25, 619–627 (2010). [DOI] [PubMed] [Google Scholar]
- 6.Anderson, R. R. & Parrish, J. A. Selective photothermolysis: precise microsurgery by selective absorption of pulsed radiation. Science220, 524–527 (1983). [DOI] [PubMed] [Google Scholar]
- 7.Kilmer, S. L. Laser treatment of tattoos. Dermatol. Clin.15, 409–417 (1997). [DOI] [PubMed] [Google Scholar]
- 8.Jow, T., Brown, A. & Goldberg, D. J. Patient compliance as a major determinant of laser tattoo removal success rates: a 10-year retrospective study. J. Cosmet. Laser Ther.12, 166–169 (2010). [DOI] [PubMed] [Google Scholar]
- 9.Mariwalla, K. & Dover, J. S. The use of lasers for decorative tattoo removal. Skin. Therapy Lett.11, 1–6 (2006). [PubMed] [Google Scholar]
- 10.Ho, S. G. & Goh, C. L. Laser tattoo removal: a clinical update. J. Cutan. Aesthet. Surg.8, 9–15 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Wu, D. C., Goldman, M. P., Wat, H. & Chan, H. H. L. A systematic review of picosecond laser in dermatology: evidence and recommendations. Lasers Surg. Med.53, 9–49 (2021). [DOI] [PubMed] [Google Scholar]
- 12.Shah, S. D. & Aurangabadkar, S. J. Newer trends in laser tattoo removal. J. Cutan. Aesthet. Surg.8, 25–29 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Khunger, N., Molpariya, A. & Khunger, A. Complications of tattoos and tattoo removal: stop and think before you ink. J. Cutan. Aesthet. Surg.8, 30–36 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Leuenberger, M. L. et al. Comparison of the Q-switched alexandrite, Nd:YAG, and Ruby lasers in treating blue-black tattoos. Dermatol. Surg.25, 10–14 (1999). [DOI] [PubMed] [Google Scholar]
- 15.Anderson, R. R., Geronemus, R., Kilmer, S. L., Farinelli, W. & Fitzpatrick, R. E. Cosmetic tattoo ink darkening. A complication of Q-switched and pulsed-laser treatment. Arch. Dermatol.129, 1010–1014 (1993). [DOI] [PubMed] [Google Scholar]
- 16.Jimenez, G., Weiss, E. & Spencer, J. M. Multiple color changes following laser therapy of cosmetic tattoos. Dermatol. Surg.28, 177–179 (2002). [DOI] [PubMed] [Google Scholar]
- 17.Bäumler, W. & Weiß, K. T. Laser assisted tattoo removal – state of the Art and new developments. Photochem. Photobiol Sci.18, 349–358 (2019). [DOI] [PubMed] [Google Scholar]
- 18.Ross, V. et al. Comparison of responses of tattoos to picosecond and nanosecond Q-switched neodymium: YAG lasers. Arch. Dermatol.134, 167–171 (1998). [DOI] [PubMed] [Google Scholar]
- 19.Gurnani, P. et al. Comparing the efficacy and safety of laser treatments in tattoo removal: a systematic review. J. Am. Acad. Dermatol.87 (1), 103–109 (2022). [DOI] [PubMed] [Google Scholar]
- 20.Lorgeou, A. et al. Comparison of two picosecond lasers to a nanosecond laser for treating tattoos: a prospective randomized study on 49 patients. J. Eur. Acad. Dermatol. Venereol.32, 265–270 (2018). [DOI] [PubMed] [Google Scholar]
- 21.Stolecka-Warzecha, A., Chmielewski, Ł., Wilczyński, S. & Koprowski, R. In vitro hyperspectral analysis of tattoo dyes. Skin. Res. Technol.29, e13268 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Menozzi-Smarrito, C. & Smarrito, S. Laser removal of cosmetic eyebrow tattoos with a picosecond laser. Dermato3, 182–192 (2023). [Google Scholar]
- 23.Kream, E. et al. Laser removal of eyeliner and eyebrow tattoos: chart review, experiences, and learnings. J. Clin. Aesthet. Dermatol.16, 47–49 (2023). [PMC free article] [PubMed] [Google Scholar]
- 24.Torbeck, R. L. et al. Evolution of the picosecond laser: a review of literature. Dermatol. Surg.45, 183–194 (2019). [DOI] [PubMed] [Google Scholar]
- 25.AlJasser, M. I. et al. Unusual color changes of eyebrow tattoo after laser: a retrospective case series. Photobiomodul Photomed. Laser Surg.43, 240–244 (2025). [DOI] [PubMed] [Google Scholar]
- 26.Hernandez, L. et al. Laser tattoo removal: laser principles and an updated guide for clinicians. J. Dermatol. Skin. Sci.4, 11–13 (2022). [DOI] [PubMed] [Google Scholar]
- 27.Pióro, W., Antoszewski, B. & Kasielska-Trojan, A. Permanent makeup removal severe complication-case report and proposal of the protocol for its management. J. Clin. Med.13, 5613 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Pióro, W., Antoszewski, B. & Kasielska-Trojan, A. Impact of removal of unsatisfactory eyebrow permanent cosmetic pigmentation on the quality of life - WHOQOL-BREF-based study. J. Cosmet. Dermatol.24, e70233 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
on request from the corresponding author (A.K.T. e-mail: anna.kasielska-trojan@umed.lodz.pl).


