Table 2.
Results of two-way repeated measures ANOVA on task-related fNIRS signals
| Channel | Oxy-Hb | Deoxy-Hb | ||||||
|---|---|---|---|---|---|---|---|---|
| F(1, 38) | p | q | ηp2 | F(1, 38) | p | q | ηp2 | |
| CH4 | 11.72 | 0.002 | 0.027 | 0.15 | ||||
| CH5 | 13.31 | 0.001 | 0.012 | 0.16 | ||||
| CH8 | 9.51 | 0.005 | 0.023 | 0.12 | ||||
| CH10 | 7.12 | 0.012 | 0.040 | 0.09 | ||||
| CH15 | 6.71 | 0.014 | 0.045 | 0.08 | ||||
| CH16 | 23.31 | < .001 | 0.002 | 0.24 | ||||
| CH18 | 13.28 | < .001 | 0.020 | 0.12 | ||||
| CH19 | 8.20 | 0.008 | 0.032 | 0.07 | ||||
| CH21 | 14.43 | < .001 | 0.028 | 0.15 | ||||
| CH23 | 7.76 | 0.009 | 0.035 | 0.06 | ||||
| CH25 | 10.33 | 0.004 | 0.022 | 0.08 | ||||
| CH29 | 8.68 | 0.008 | 0.049 | 0.14 | ||||
| CH30 | 9.49 | 0.006 | 0.042 | 0.20 | ||||
| CH31 | 9.59 | 0.005 | 0.023 | 0.19 | ||||
| CH32 | 20.54 | < .001 | 0.003 | 0.27 | 9.53 | 0.005 | 0.043 | 0.12 |
| CH38 | 11.94 | 0.003 | 0.018 | 0.21 | ||||
| CH39 | 11.44 | 0.003 | 0.018 | 0.22 | ||||
| CH40 | 14.10 | < .001 | 0.013 | 0.26 | ||||
| CH41 | 14.46 | < .001 | 0.013 | 0.27 | 12.51 | 0.002 | 0.026 | 0.18 |
F-values and the corresponding FDR-corrected q-values for main effects of task precision, hand performance, and their interaction are shown for channels that exhibited significant effects after FDR correction (q < 0.05).. Oxyhemoglobin (oxy-Hb) and deoxyhemoglobin (deoxy-Hb) signals were separately analyzed.