Table 3. Temperature at the centre of the beam footprint on the crystal Tc, standard deviation of height error along the beam footprint centre axis over 2×FWHM length std at three key moments: just after the XFEL pulse power loading; at first-turn time 1 µs; at period-end time tper.
Results are compared between water (H2O) and liquid nitrogen (LN2) cooling, between three different repetition times tper = 1, 10, 50 µs. Results for CW steady state analyses with either H2O or LN2 cooling are also included as reference. The reduction factor of the height error std by LN2 cooling related to H2O cooling freduction = std(LN2)/std(H2O). The same average XFEL power is assumed.
| H2O cooling | LN2 cooling | |||||
|---|---|---|---|---|---|---|
| Height error (pm) | Tc (K) | std (pm) | Tc (K) | std (pm) | freduction by LN2 cooling | |
| tper = 50 µs | Peak | 543 | 3282 | 466 | 3778 | 0.87 |
| At 1 µs | 512 | 1521 | 398 | 1826 | 0.83 | |
| At tper | 399 | 19.3 | 129 | 0.02 | 1108 | |
| tper = 10 µs | Peak | 444 | 735 | 282 | 742 | 0.99 |
| At 1 µs | 434 | 356 | 164 | 11.8 | 30 | |
| At tper | 411 | 72.9 | 131 | 0.005 | 13748 | |
| tper = 1 µs | Peak | 419 | 210 | 169 | 56.8 | 3.7 |
| At 1 µs | 416 | 147 | 134 | 0.15 | 1008 | |
| At tper | 416 | 147 | 134 | 0.15 | 1008 | |
| CW steady state | 417 | 163 | 139 | 1.82 | 89.5 | |