. 2026 Mar 3;2026:5550877. doi: 10.1155/ijod/5550877

Accuracy of Marginal and Internal Adaptation of Advanced Lithium Disilicate Crowns Using Different Margin Designs (In Vitro Study)

Hossameldin Hassan Abdelrazek Mohamed 1,✉, Amir Azer 1, Rewaa G AboElHassan 1
Editor: Cesar Rogério Pucci
PMCID: PMC12957775  PMID: 41788229

Abstract

Background

Advanced lithium disilicate glass ceramics offer excellent esthetics, but conservative crown preparations are not always the preferred choice. Various margin designs are available; however, more conservative vertical preparations (vertipreps) have less scientific evidence supporting their esthetic outcomes compared to shoulder or chamfer designs.

Aim of the Study

To assess the marginal adaptation and internal fit of crowns fabricated from advanced lithium disilicate (CEREC Tessera) using computer‐aided design and manufacturing (CAD/CAM) with three distinct margin designs.

Materials and Methods

Three mandibular molar typodont teeth were prepared with three finish line designs: chamfer 0.5 mm (C), rounded shoulder 1 mm (RS), and vertiprep 0.2 mm (V) using a modified dental surveyor for standardization. Silicone replicas were used to create epoxy resin dies. Twenty‐four crowns were produced on the replicated resin dies, with eight crowns for each finish line design (n = 8). Preparations were scanned using an intraoral scanner (Carestream Dental LLC, 3625 Cumberland Blvd., Ste. 700, Atlanta, GA 30339), and advanced lithium disilicate (Tessera) crowns were milled via CAD/CAM. Crowns were cemented onto their respective dies, and marginal adaptation was measured using a stereomicroscope; then, crowns were sectioned using a microtome to evaluate internal fit.

Results

One‐way ANOVA showed a significant difference in the marginal adaptation among groups (p  < 0.001). Group RS had the largest gap (125.45 ± 12.11 µm), followed by Group C (107.31 ± 9.25 µm) and Group V (101.79 ± 9.01 µm). Internal fit also differed significantly (p  < 0.001), with Group V having the smallest gap (70.09 ± 8.45 µm), followed by Group RS (87.85 ± 6.82 µm) and Group C (94.45 ± 9.21 µm).

Conclusion

The vertiprep showed the least marginal adaptation and best internal fit compared to shoulder and chamfer designs, with no significant difference in marginal gap between vertiprep and chamfer.

Keywords: CAD/CAM, ceramics, crown, crown preparations, marginal adaptation

1. Background

The accuracy of CAD/CAM restorations is strongly influenced by both the preparation design and the milling process. Well‐prepared teeth with clear margins allow the system to produce crowns with better adaptation, while poor preparations increase marginal discrepancies. Marginal adaptation depends on the precision of the finish line reproduction, since large gaps can lead to cement breakdown or secondary caries. Internal fit is also preparation‐dependent, as smooth internal surfaces facilitate accurate seating of the restoration. Overall, tooth preparation quality and CAD/CAM accuracy work together to determine crown longevity and clinical success [1, 2].

Marginal adaptation and internal fit of restorations are two important clinical factors in assessing the quality and durability of CAD/CAM ceramic restorations. The misfits between the restoration and the prepared tooth, including marginal adaptation and internal fit affecting the restoration seating, lead to microleakage, recurrent caries, tooth hypersensitivity, followed by periodontal disease and eventual failure of restorations [3]. The clinically acceptable range of marginal adaptation, less than 174 µm, was reported in systematic reviews [4, 5], and the values of the internal fit were between 200 and 300 µm [6].

In general, there are two types of preparation: horizontal preparation, which uses finish lines, and nonhorizontal preparation, referred to as featheredge or vertical preparation (vertiprep) [7]. The shoulder and chamfer are commonly used as horizontal finish lines in dental preparations due to their widespread application. This approach helps to minimize overhangs and overcontouring, which are notable drawbacks of vertiprep. However, vertiprep designs have been restricted due to challenges in accurately locating the tapered, thin margins and the increased risk of chipping fractures in the restorations [8, 9].

The design of crown preparation plays a key role in selecting the restorative material, as it affects retention, support, esthetics, and the necessary thickness for strength. Less invasive vertipreps are generally suited for ceramic restorations, whereas more extensive horizontal designs are often required for materials like zirconia, which offer superior mechanical strength. Because materials vary in fracture resistance and stiffness, the preparation must be planned to harmonize material properties with the biological needs of the tooth [10]. New material, advanced lithium disilicate CAD/CAM blocks (CEREC Tessera), was introduced by Dentsply Sirona in 2021. Advanced lithium disilicate glass ceramic contains a two‐part crystal composition (lithium disilicate + virgilite) embedded in a glassy zirconia matrix; the new ceramic composition made it possible for the ceramic to fire quickly for 4.5–12 min at 760°C. Virgilite is a new crystal type that is activated by the matrix firing process. The flexural strength of advanced lithium disilicate is over 700 MPa. It exhibited better results in marginal adaptation, internal fit, and fracture resistance compared to traditional lithium disilicate crowns [11]. It would be a promising material regarding the marginal integrity and fracture resistance of the crown [12, 13]. The present study aims to evaluate the marginal adaptation and the internal fit of advanced lithium disilicate crowns prepared with different forms of finish lines: rounded shoulder (RS), chamfer (C), and vertiprep (V). The null hypothesis was that no significant difference would be found between the three different finish line designs.

2. Material and Methods

2.1. Study Design and Sample Size

This study was an in vitro, parallel‐controlled trial aimed at evaluating the marginal gap and internal fit among three different groups. The study was conducted in the laboratory of the Conservative Dentistry Department at the Faculty of Dentistry, Alexandria University, Egypt.

The sample size was determined using the Inline graphicPower software (Version 3.1.9.2, Department of Biomedical Informatics and Medical Statistics, Medical Research Institute, University of Alexandria, Egypt), with assumptions of 80% statistical power and a 5% alpha level. Based on mean comparisons from a previous study, the required sample size was calculated as 8 specimens per group. The total sample size required = number of groups × number per group = 3 × 8 = 24 [14].

2.2. Specimen Preparation

Three mandibular left second molar typodont teeth (Kilgore Nissin 200 brand, USA) were used to prepare three finish line designs to receive advanced lithium disilicate (CEREC Tessera: Dentsply Sirona, USA) crowns.

Three mandibular teeth were inserted into acrylic blocks and prepared with the following criteria:

Around 1.5–2 mm occlusal reduction for all groups, and the axial reduction was 0.5 mm for group C, 1 mm for group RS, and 0.2 mm for group V, with a total convergence angle of 6° using a modified dental surveyor for standardization and to ensure a consistent degree of taper [1, 15, 16] (Figures 1 and 2).

Figure 1.

Figure 1

Modified dental surveyor.

Figure 2.

(a) Chamfer, (b) shoulder, and (c) vertiprep.

graphic file with name IJOD-2026-5550877-g013.webp

(a)

graphic file with name IJOD-2026-5550877-g012.webp

(b)

graphic file with name IJOD-2026-5550877-g011.webp

(c)

Positive replicas of the prepared teeth were fabricated for each preparation by using a silicone duplicating material. Subsequently, epoxy resin material (RenCast Epoxy Casting Resin, CH‐4057 Basel, Switzerland) was poured eight times for each group, with a total number of 24 models across all groups [17]. These epoxy dies were then categorized into three groups according to their respective finish line designs.

Twenty‐four epoxy resin dies were scanned using an intraoral scanner (Carestream Dental LLC, 3625 Cumberland Blvd., Ste. 700, Atlanta, GA 30339), and the scan data were then imported into CAD software (Exocad 3.0, Galway GmbH, Darmstadt, Germany) to design the crown, with the cement space set at 50 µm for the axial and occlusal surfaces for better fit accuracy and adequate fracture strength [18–20]. After designing, the STL file was transmitted to a computer‐controlled five‐axis milling unit (ED5X EMAR, C2, Industrial Complex, 10th of Ramadan City, Asharqia, Egypt) for the milling procedure, and each crown was milled to its corresponding scanned model (Figure 3).

Figure 3.

Scanning of specimens with different designs. (a) Chamfer, (b) shoulder, and (c) vertiprep.

graphic file with name IJOD-2026-5550877-g010.webp

(a)

graphic file with name IJOD-2026-5550877-g009.webp

(b)

graphic file with name IJOD-2026-5550877-g001.webp

(c)

Each crown was then cemented to its corresponding die after etching the intaglio surfaces of the crowns using hydrofluoric acid gel 9.5% (BISCO’s PORCELAIN ETCHANT 9.5% Hydrofluoric Acid Gel), following the manufacturer’s recommendations. Silane (BISCO‐Schaumburg, USA) was applied to the bonding surfaces and left for 60 s, then air‐dried for 5 s. Crowns were bonded using dual‐cure adhesive resin cement (Supercem Self Etch, Self‐Adhesive Resin Cement Universal, DENTKIST, KOREA). They were positioned on the corresponding dies using finger pressure, then subjected to an axial static load of 5 kg, followed by an initial light‐curing for 1–2 s to remove excess cement with a scalpel blade, followed by a final curing exposure of 40 s on each surface of the crown, and the chemical setting time was 5 min [1] (Figures 4 and 5).

Figure 4.

Figure 4

Loading 5 kg on the specimen.

Figure 5.

Figure 5

Grouping samples after cementation of Tessera crowns on their corresponding dies.

To ensure full polymerization, all specimens were kept at 37°C and 100% relative humidity for 24 h then thermocycled [21] 2500 times to simulate 3 months of clinical use by a custom‐made device, Dental Biomaterial Department, Faculty of Dentistry, Alexanderia University. Each water bath had a dwell time of 25 s, along with a 10 s delay, and temperatures ranged from a minimum of 5°C to a maximum of 55°C [21, 22].

2.3. Evaluation of Marginal Gap and Internal Adaptation

Before sectioning of crowns, the vertical marginal gap was evaluated for each group; each specimen was evaluated separately by using a stereomicroscope (Olympus SV, Japan) connected to a digital camera under a magnification of 40× [1, 23, 24].

Eight points were selected (midbuccal, midlingual, middistal, midmesial, mesiolingual, mesiobuccal, distolingual, and distobuccal) to be measured by a stereomicroscope [23–27]. All measurements were carried out by a single blind examiner (Figures 6 and 7).

Figure 6.

Figure 6

Marginal gap in midbuccal captured by stereomicroscope at 40× magnification. (a) Chamfer design, (b) rounded shoulder, and (c) vertical preparation design.

Figure 7.

Figure 7

Marginal gap in mesiolingual line angle captured by stereomicroscope at 40× magnification. (a) Chamfer design, (b) rounded shoulder, and (c) vertical preparation design.

The specimens were placed in transparent epoxy blocks and sectioned at the midplane buccolingually by a microtome (Micracut 150, Metkon Metallography Bursa, Turkey), then cleaned by micro brush to remove any potential debris that could affect the measurements and evaluated for the internal fit at the following seven points of each group under magnification of 60× using a stereomicroscope [25, 28, 29] (Figures 8–11).

Figure 8.

Figure 8

Internal gaps presentation in specimen after sectioning.

Figure 11.

Figure 11

Internal gap of midocclusal point captured by stereomicroscope at 60× magnification. (a) Chamfer design, (b) rounded shoulder, and (c) vertical preparation design.

Figure 9.

Figure 9

Specimen in acrylic block attached to microtome for sectioning in buccolingual direction.

Figure 10.

Figure 10

Internal gap of cusp tip area captured by stereomicroscope at 60× magnification. (a) Chamfer design, (b) rounded shoulder, and (c) vertical preparation design.

  • P1: The junction of the cervical and axial wall on the buccal aspect.

  • P2: The midaxial point on the buccal aspect.

  • P3: Cusp tip area.

  • P4: The midocclusal point.

  • P5: Cusp tip area.

  • P6: The midaxial point on the lingual aspect.

  • P7: The junction of the cervical and axial wall on the lingual aspect.

2.4. Statistical Analysis

Data were analyzed using IBM SPSS, version 23, Armonk, NY, USA. The normality of variables was checked using the Shapiro–Wilk test and Q–Q plots. Normal distribution was confirmed for both marginal gap and internal adaptation; thus, values were mainly presented using mean and standard deviation (SD) in addition to median, minimum, and maximum values. Comparison between groups was done using one‐way ANOVA followed by Tukey’s post hoc test with Bonferroni correction to adjust for Type I error. All tests were two‐tailed, and the significance level was set at α = 0.05.

3. Results

For the marginal adaptation (µm) among the groups. The group RS preparation technique resulted in the largest mean marginal adaptation, followed by group C and group V (Table 1) (Figure 12).

Table 1.

Comparison of marginal adaptation (µm) among the study groups.

Statistical parameters

Vertiprep

(n = 8)

Chamfer

(n = 8)

Rounded shoulder

(n = 8)

Mean ± SD 101.79 ± 9.01 107.31 ± 9.25 125.45 ± 12.11
Median 99.95 109.44 130.12
Min – max 91.62 – 122.61 94.33 – 119.71 108.64 – 136.60
  • F‐test

  • (p‐value)

  • 11.73

  • (<0.001 ∗)

 ∗Statistically significant difference at p‐value < 0.05, F‐test: One‐way ANOVA test.

Figure 12.

Figure 12

Comparison of marginal gap (µm) among the study groups.

Post hoc pairwise comparisons revealed that there was no significant difference between the V and C groups. In contrast, the V and RS groups differed significantly. Similarly, the C and RS groups also showed a significant difference (Table 2) (Figure 12).

Table 2.

Pairwise comparisons between study groups regarding marginal adaptation.

Groups Compared to Mean diff 95% CI p‐Valuea
Vertiprep Chamfer −5.52 −18.40, 7.36 0.536
Rounded shoulder −23.66 −36.54, −10.77 <0.001 ∗
Chamfer Rounded shoulder 5.52 −7.36, 18.40 0.005 ∗

Abbreviation: CI, confidence interval.

a p Value: Tukey’s post hoc test.

 ∗Statistically significant difference at p value < 0.05.

For the internal fit (µm) across the three preparation techniques. The V group had the smallest mean internal adaptation, followed by the RS group and the C group, which had the largest mean (Figure 13) (Table 3).

Figure 13.

Figure 13

Comparison of internal adaptation (µm) among the study groups.

Table 3.

Comparison of internal fit (µm) among the study groups.

Statistical parameters

Vertiprep

(n = 8)

Chamfer

(n = 8)

Rounded shoulder

(n = 8)

Mean ± SD 70.09 ± 8.45 94.45 ± 9.21 87.85 ± 6.82
Median 72.06 95.02 85.69
Min – max 57.91 – 82.50 74.74 – 106.18 82.64 – 104.34
  • F‐test

  • (p‐value)

  • 18.81

  • (<0.001 ∗)

 ∗Statistically significant difference at p‐value < 0.05. F‐test: One‐way ANOVA test.

Post hoc pairwise comparisons indicated that the V and C groups differed significantly. The V and RS groups also showed a significant difference. However, the difference between the C and RS groups was not statistically significant (Table 4) (Figure 13).

Table 4.

Pairwise comparisons between study groups regarding internal fit.

Groups Compared to Mean diff 95% CI p‐Valuea
Vertiprep Chamfer −24.37 −34.73, −14.01 <0.001 ∗
Rounded shoulder −17.76 −28.12, −7.40 0.001 ∗
Chamfer Rounded shoulder 24.37 14.01, 34.72 0.265

Abbreviation: CI, confidence interval.

a p Value: Tukey’s post hoc test.

 ∗Statistically significant difference at p value < 0.05.

4. Discussion

The marginal adaptation and the internal fit of advanced lithium disilicate crowns (CEREC Tessera) were evaluated among three different marginal designs. The null hypothesis was rejected, as significant differences were found between Group V and Group RS in marginal adaptation and between Group V and Group C in internal fit. However, no significant difference was observed between Group V and Group C in marginal adaptation, nor between Group C and Group RS in internal fit. These results highlight the influence of preparation design on the marginal and internal adaptation of advanced lithium disilicate crowns.

Compared to horizontal preparations, the vertiprep design provided a clearly superior coronal seal and reduced the gap between the teeth and the crown, improving the fit and reducing bacterial penetration. This effect is attributed to the vertical configuration of the preparation. As the marginal angle decreases from 90° shoulders to 45° or 30° chamfers and finally to 0° vertical margins, the gap becomes progressively smaller. In theory, vertical margins can result in an almost perfect, gap‐free fit [30–32].

CAD/CAM material development follows two paths: enhancing zirconia’s translucency without losing strength and improving glass ceramics’ strength while retaining esthetics. These advances may converge in materials like advanced lithium disilicate (e.g., CEREC Tessera), which combines strength and esthetics, can be etched for durable bonding, and supports more conservative procedures [33, 34]. In the context of s, such material characteristics are highly influential. The ability to achieve a strong adhesive interface contributes to precise marginal adaptation, reducing microgaps at the finish line, while the superior machinability of glass ceramics enhances the accuracy of CAD/CAM milling, thereby improving the internal fit of restorations [35]. Consequently, the balance of esthetics, strength, and bonding not only supports functional and esthetic outcomes but also directly impacts the quality of adaptation in vertipreps, reinforcing the rationale for the chosen restorative material in this study.

To ensure standardization, all types of crown preparations were carried out using a modified dental surveyor. For all samples, a dual‐cured universal adhesive resin cement was utilized for luting all crown restorations onto their respective epoxy resin dies. These dies were selected for their dimensional stability and a modulus of elasticity (11.8 GPa), which closely approximates that of dentin (18 GPa), and showing provided crown restorations with acceptable marginal fit [36, 37].

Thermocycling was used to simulate 3 months of clinical service, in accordance with International Organization for Standardization guidelines. Thermal aging produced only a minimal increase in marginal discrepancies, which remained within clinically acceptable limits [19, 38].

The marginal adaptation of all crowns was evaluated using a stereomicroscope set at a fixed 40× magnification for measuring the marginal gap and 60× magnification for measuring the internal fit. This technique provides a cost‐effective and nondestructive method for assessment, allowing measurements to be performed directly without the need for intermediate materials such as impression material or luting cement. However, this technique also presents certain limitations, including challenges in accurately identifying measurement points at the margin, difficulties in reproducing these points consistently, and problems in clearly distinguishing the tooth structure from the restoration, especially in shaded areas [1, 23–25].

For internal fit evaluation, the cross‐sectional method (CSM) was a widely utilized technique for evaluating crown fit and marginal adaptation. It provided precise measurements directly from the prosthesis after cementation, effectively simulating clinical conditions. It’s exhibited for its accuracy and high‐resolution imaging; this conventional approach ensured reliable assessment, and besides, it is methodologically efficient [39, 40].

So that each sample was sectioned in buccallingual directions along the long axis of the crown using a microtome [28]. A study compared the CSM with the silicon replica technique (SRT), which did not find statistically significant differences between the values obtained with CSM and SRT [40].

In the present study, there was a significant difference in the marginal adaptation among the three different groups. The rounded shoulder preparation technique showed the largest mean marginal adaptation (125.45 ± 12.11 µm), followed by the chamfer with a mean marginal gap (107.31 ± 9.25 µm) and vertiprep, which exhibited the least mean marginal adaptation (101.79 ± 9.01 µm); however, there was no significant difference between the chamfer and vertiprep designs.

The reference range of marginal adaptation reported in our literature was between 91.62 and 136.60 µm; these values fall within the clinically acceptable range, which is less than 174 µm as, reported in systematic reviews [4, 5].

In previous studies, the number of measurement points per crown used has varied considerably; the present results were compatible with Comlekoglu et al. [41], who measured 16 points per crown and found that the vertiprep had the highest marginal adaptation in comparison with the round shoulder finish line in zirconia crowns. According to these findings, this was because the more the restoration margin finishes with an acute angle, the smaller the marginal adaptation, as previously explained by Schillinburg et al. [42].

The current results were aligned with Salama et al. [19], who measured marginal adaptation in zirconia crowns with vertical design as opposed to those with rounded shoulder design; they concluded that specimens with a rounded shoulder finish line exhibited significantly higher marginal adaptation values compared to those with featheredge finish lines.

Similarly, it was consistent with El‐Eneen et al. [43], who reported lower marginal adaptation values for the vertiprep design than chamfer finish lines in zirconia‐reinforced lithium silicate crowns, but it was statistically not significant, and Eldamaty et al. [44], who discovered no statistically significant differences in the marginal accuracy of monolithic zirconia crowns with chamfer and vertical margins.

In contrast with the present findings, Nasir and Kadhim [45] evaluated the influence of the chamfer and vertiprep techniques on marginal adaptation in zirconia crowns. The study demonstrated that there was a significant difference between the vertiprep group, which demonstrated the smallest marginal adaptation values, and the chamfer group, which showed the largest marginal adaptation values. Different results were obtained because the study was based on extracted natural teeth from orthodontic patients.

Furthermore, Rizonaki et al. [46] reported that the rounded shoulder finish line had the least marginal gap between the chamfer and vertiprep design in lithium disilicate crowns (e.max CAD), and the notable differences may be revealed due to using a different methodology, which is microcomputed tomography, which may create artificial defects caused by ray reflections. However, the micro‐CT obscures marginal spaces in narrow gaps [40, 47].

There were significant differences in the internal fit among the three different groups. Vertiprep showed the smallest mean internal fit (70.09 ± 8.45 µm), followed by rounded shoulder (87.85 ± 6.82 µm), and chamfer, which exhibited the largest mean (94.45 ± 9.21 µm). However, there was no significant difference between shoulder and chamfer designs.

The reference range of internal fit reported in our literature review was between 57.91 and 106.18 µm. These values fall within the clinically acceptable range, which is between 200 and 300 µm [6].

The current findings were supported by Rizonaki et al. [46], who reported that the vertiprep design had the best internal fit compared with shoulder and chamfer finish line design preparation in lithium disilicate crowns.

It was consistent with ElgGandy et al. [48], who found that there was no significant difference in the internal fit values between rounded shoulder and chamfer designs in lithium disilicate crowns.

Also aligned with Baig et al. [49], whose results reported that there was no statistically significant difference in internal fit values between shoulder and chamfer finish lines in lithium disilicate crowns.

In contrast to current findings, Al‐Baadani et al. [50] found that the internal fit of full contour zirconia crowns with a deep chamfer finish line design was better than full contour zirconia crowns with a shoulder finish line design, and this may be due to the fact that the thickness of the deep chamfer design was 1 mm.

Furthermore, Rizonaki et al. [46] showed that the rounded shoulder group exhibited the highest internal fit values compared to the chamfer and vertiprep groups; this discrepancy may result because the cement space was set at 80 µm.

In the present study, advanced lithium disilicate strengthened with virgilite (CEREC Tessera) was used for the milling of all crowns. More than 700 MPa flexural strength, with up to a 32% increase in strength compared to conventional lithium disilicate, was claimed by the manufacturer, as the interwoven dual crystal composition between lithium disilicate and virgilite crystals acts like a reinforcement bar (rebar effect), and this might have contributed to the high‐margin adaptation of the vertiprep design after both milling and thermomechanical aging in comparison to the chamfer margin, as the risk of chipping was reduced [13, 51].

This study had several limitations. Notably, evaluating marginal adaptation in vivo is challenging, as luting agents and bonding mechanisms can influence marginal adaptation and internal fit, especially with temperature fluctuations [22, 52]. It is recommended that advanced technologies, such as the triple‐scan protocol or micro‐CT scanning, be employed in future studies [46].

5. Conclusion

Vertiprep design revealed the least marginal adaptation and internal fit compared to rounded shoulder designs for advanced lithium disilicate crowns (CEREC Tessera). However, there was no significant difference between the vertiprep and the chamfer design in marginal adaptation. This suggests that VertiPrep may be a more conservative and biologically compatible approach, as it preserves more tooth structure while maintaining excellent adaptation.

Nomenclature

°C:

Celsius or centigrade

µm:

Micrometer

CAD/CAM:

Computer‐aided design and computer‐aided manufacturing

IBM SPSS:

Software for advanced statistical analysis

kg:

Kilogram

mm:

Millimeter

MO:

Marginal opening

MPa:

Megapascal

no.:

Number

P:

Probability

SD:

Standard deviation.

Author Contributions

Hossameldin Hassan Abdelrazek Mohamed contributed to the study design, the data acquisition, analysis, and interpretation, and wrote the manuscript draft. Rewaa G. AboElHassan contributed to the study design and the interpretation of the results and revised the manuscript. Amir Azer contributed to the study design, revised the manuscript, and supervised the work.

Funding

This study was not funded by any agency in the public, commercial, or nonprofit sectors.

Disclosure

All authors have read and approved the final manuscript.

Ethics Statement

This study was approved by the Scientific Research Ethics Committee at the Faculty of Dentistry, Alexandria University (International Number: IORG0008839, Ethics Committee Number: 0488‐8/2023). All methods were performed following the Declaration of Helsinki and the ethical guidelines adopted by the Research Ethics Committee of the Faculty of Dentistry, Alexandria University. No human participants were involved in the study.

Consent

The authors have nothing to report.

Conflicts of Interest

The authors declare no conflicts of interest.

Mohamed, Hossameldin Hassan Abdelrazek , Azer, Amir , AboElHassan, Rewaa G. , Accuracy of Marginal and Internal Adaptation of Advanced Lithium Disilicate Crowns Using Different Margin Designs (In Vitro Study), International Journal of Dentistry, 2026, 5550877, 11 pages, 2026. 10.1155/ijod/5550877

Academic Editor: Cesar Rogério Pucci

Contributor Information

Hossameldin Hassan Abdelrazek Mohamed, Email: hossameldin.hassan.dent@alexu.edu.eg.

Cesar Rogério Pucci, Email: cesar@fosjc.unesp.br.

Data Availability Statement

The datasets generated and analyzed during the current study are available from the corresponding author upon reasonable request.

References

  • 1. Ashour A. M., El-Kateb M. M., and Azer A. S., The Effect of Two Preparation Designs on the Fracture Resistance and Marginal Adaptation of Two Types of Ceramic Crowns Using CAD/CAM Technology (In Vitro Study), BMC Oral Health. (2024) 24, no. 1, 10.1186/s12903-024-04742-4, 1065. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Sengottaiyan A. K., Bennani V., and Veerasamy A., Influence of Tooth Preparation Design on Margin Discrepancy and Internal Gap in Digitally Fabricated Fixed Complete Coverage Zirconia Prostheses: A Systematic Review of In Vitro Studies, The Journal of Prosthetic Dentistry. (2025) 134, no. 3, 616–627, 10.1016/j.prosdent.2025.04.030. [DOI] [PubMed] [Google Scholar]
  • 3. Khamverdi Z., Najafrad E., and Farhadian M., In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System With Two Different Scanners, Frontiers in Dentistry. (2021) 18, 10.18502/fid.v18i2.5432, 2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Contrepois M., Soenen A., Bartala M., and Laviole O., Marginal Adaptation of Ceramic Crowns: A Systematic Review, The Journal of Prosthetic Dentistry. (2013) 110, no. 6, 447–454.e10, 10.1016/j.prosdent.2013.08.003. [DOI] [PubMed] [Google Scholar]
  • 5. Boitelle P., Mawussi B., Tapie L., and Fromentin O., A Systematic Review of CAD/CAM Fit Restoration Evaluations, Journal of Oral Rehabilitation. (2014) 41, no. 11, 853–874, 10.1111/joor.12205. [DOI] [PubMed] [Google Scholar]
  • 6. Ribeiro I. L., Campos F., and Sousa R. S., et al.Marginal and Internal Discrepancies of Zirconia Copings: Effects of Milling System and Finish Line Design, Indian Journal of Dental Research. (2015) 26, no. 1, 15–20, 10.4103/0970-9290.156790. [DOI] [PubMed] [Google Scholar]
  • 7. Loi I. and Di Felice A., Biologically Oriented Preparation Technique (BOPT): A New Approach for Prosthetic Restoration of Periodontically Healthy Teeth, The European Journal of Esthetic Dentistry. (2013) 8, no. 1, 10–23. [PubMed] [Google Scholar]
  • 8. Ramos R. M., Clark D., and Mazza M., et al.The Shoulderless Approach: A New Rationale in Prosthetic Dentistry, Tomorrow Tooth Journal. (2017) 1, 1–29. [Google Scholar]
  • 9. Kasem A. T., Sakrana A. A., Ellayeh M., and Özcan M., Evaluation of Zirconia and Zirconia-Reinforced Glass Ceramic Systems Fabricated for Minimal Invasive Preparations Using a Novel Standardization Method, Journal of Esthetic and Restorative Dentistry. (2020) 32, no. 6, 560–568, 10.1111/jerd.12570. [DOI] [PubMed] [Google Scholar]
  • 10. Sulaiman T. A., Suliman A. A., Abdulmajeed A. A., and Zhang Y., Zirconia Restoration Types, Properties, Tooth Preparation Design, and Bonding. A Narrative Review, Journal of Esthetic and Restorative Dentistry. (2024) 36, no. 1, 78–84, 10.1111/jerd.13151. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Fayed A. K., Azer A. S., and AboElhassan R. G., Fit Accuracy and Fracture Resistance Evaluation of Advanced Lithium Disilicate Crowns (In- Vitro Study), BMC Oral Health. (2025) 25, no. 1, 10.1186/s12903-024-05325-z, 58. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Marchesi G., Camurri Piloni A., Nicolin V., Turco G., and Di Lenarda R., Chairside CAD/CAM Materials: Current Trends of Clinical Uses, Biology. (2021) 10, no. 11, 10.3390/biology10111170, 10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Phark J.-H. and Duarte Jr S., Microstructural Considerations for Novel Lithium Disilicate Glass Ceramics: A Review, Journal of Esthetic and Restorative Dentistry. (2022) 34, no. 1, 92–103, 10.1111/jerd.12864. [DOI] [PubMed] [Google Scholar]
  • 14. Fouad M., Marginal Adaptation Related to Margin Design of CAD/CAM Ceramic Crowns, Egyptian Dental Journal. (2023) 69, no. 1, 447–455, 10.21608/edj.2022.163948.2270. [DOI] [Google Scholar]
  • 15. El-Hefnawy W. T., Mandour M. H., Montaser A. G., and Elhefnawy M., Marginal Adaptation and Failure Load of Hybrid Ceramic Crowns With Shoulder and Feather-Edge Margin Designs After Thermomechanical Fatigue, Al-Azhar Journal of Dentistry. (2024) 11, no. 4, 10.58675/2974-4164.1647, 11. [DOI] [Google Scholar]
  • 16. Abdullah L. S. and Ibraheem A. F., The Effect of Finishing Line Designs and Occlusal Surface Reduction Schemes on Vertical Marginal Fit of Full Contour CAD/CAM Zirconia Crown Restorations (A Comparative In Vitro Study), International Journal of Dentistry and Oral Health. (2017) 4, 1–6. [Google Scholar]
  • 17. Kusy R. P. and Leinfelder K. F., In Situ Replication Techniques: I. Preliminary Screening and the Negative Replication Technique, Journal of Dental Research. (1977) 56, no. 8, 925–932, 10.1177/00220345770560081701. [DOI] [PubMed] [Google Scholar]
  • 18. Nasr D. M. and AboElHassan R. G., Effect of Different Ceramic Materials and Dentin Sealing on Occlusal Veneers Bond Strength and Fracture Resistance, BMC Oral Health. (2025) 25, no. 1, 10.1186/s12903-025-05505-5, 186. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Salama M. A., Aldamaty M. F., Abdalla M. A., Omar E. A., AbdElaziz M. H., and Alqutaibi A. Y., Marginal Fit and Fracture Resistance of Vertical Versus Horizontal Margins in Monolithic Zirconia Crowns, Clinical and Experimental Dental Research. (2025) 11, no. 1, 10.1002/cre2.70064. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Salem N. M., Abdel Kader S. H., Al Abbassy F., and Azer A. S., Evaluation of Fit Accuracy of Computer-Aided Design/Computer-Aided Manufacturing Crowns Fabricated by Three Different Digital Impression Techniques Using Cone-Beam Computerized Tomography, European Journal of Prosthodontics. (2016) 4, no. 2, 10.4103/2347-4610.190609, 32. [DOI] [Google Scholar]
  • 21. Catelan A., Briso A. L. F., Sundfeld R. H., Goiato M. C., and dos Santos P. H., Color Stability of Sealed Composite Resin Restorative Materials After Ultraviolet Artificial Aging and Immersion in Staining Solutions, The Journal of Prosthetic Dentistry. (2011) 105, no. 4, 236–241, 10.1016/S0022-3913(11)60038-3. [DOI] [PubMed] [Google Scholar]
  • 22. Salem R., The Effect of Preparation Design on the Marginal Adaptation of Monolithic Crowns Made of New CAD/CAM Ceramic Material an In-Vitro Study, Ahram Canadian Dental Journal. (2024) 3, no. 1, 27–41, 10.21608/acdj.2024.247282.1011. [DOI] [Google Scholar]
  • 23. Sakrana A. A., In Vitro Evaluation of the Marginal and Internal Discrepancies of Different Esthetic Restorations, Journal of Applied Oral Science. (2013) 21, no. 6, 575–580, 10.1590/1679-775720130064. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Sayed A. M. and Odeh E., The Effect of Thermocycling on the Marginal Integrity of 3d Printed and Machined Hybrid Resin-Ceramic Crowns: An In-Vitro Study, Egyptian Dental Journal. (2025) 71, no. 3, 2355–2361, 10.21608/edj.2025.375929.3446. [DOI] [Google Scholar]
  • 25. Al-Mussawi R. M., Farid F., and Haider J., Effect of Die Materials on Marginal and Internal Adaptation of Zirconia Copings: An In Vitro Study, The Open Dentistry Journal. (2021) 15, no. 1, 708–716, 10.2174/1874210602115010708. [DOI] [Google Scholar]
  • 26. Zhang Y. and Dudley J., The Influence of Different Cement Spaces on the Marginal Gap of CAD/CAM all-Ceramic Crowns, Australian Dental Journal. (2019) 64, no. 2, 167–174, 10.1111/adj.12688. [DOI] [PubMed] [Google Scholar]
  • 27. Elrashid A. H., AlKahtani A. H., Alqahtani S. J., Alajmi N. B., and Alsultan F. H., Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In Vitro Study, Journal of International Society of Preventive and Community Dentistry. (2019) 9, no. 2, 178–184, 10.4103/jispcd.JISPCD_18_19. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Hanoon Z. A., Abdullah H. A., Al-Ibraheemi Z. A., Alamoush R. A., Sami S. M., and Haider J., Marginal Fit of Porcelain Laminate Veneer Materials Under Thermocycling Condition: An In-Vitro Study, Dentistry Journal. (2023) 11, no. 1, 10.3390/dj11010012, 12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Anunmana C., Charoenchitt M., and Asvanund C., Gap Comparison Between Single Crown and Three-Unit Bridge Zirconia Substructures, The Journal of Advanced Prosthodontics. (2014) 6, no. 4, 253–258, 10.4047/jap.2014.6.4.253. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30. Cagidiaco M. C., Ferrari M., Bertelli E., Mason P. N., and Russo J., Cement Thickness and Microleakage Under Metal-Ceramic Restorations With a Facial Butted Margin: An In Vivo Investigation, The International Journal of Periodontics & Restorative Dentistry. (1992) 12, no. 4, 324–331. [PubMed] [Google Scholar]
  • 31. Gavelis J. R., Morency J. D., Riley E. D., and Sozio R. B., The Effect of Various Finish Line Preparations on the Marginal Seal and Occlusal Seat of Full Crown Preparations, The Journal of Prosthetic Dentistry. (1981) 45, no. 2, 138–145, 10.1016/0022-3913(81)90330-9. [DOI] [PubMed] [Google Scholar]
  • 32. Stack J. and Millar B., Six-Year Analysis of Posterior Zirconia Crowns With Vertical Margin Preparations: Six-Year Analysis of Posterior Zirconia Crowns With Vertical Margin Preparations, British Dental Journal. (2025) 238, no. 10, 807–812, 10.1038/s41415-024-7951-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Dasari L., Anwarullah A., Mandava J., Konagala R. K., Karumuri S., and Chellapilla P. K., Influence of Obturation Technique on Penetration Depth and Adaptation of a Bioceramic Root Canal Sealer, Journal of Conservative Dentistry. (2020) 23, no. 5, 505–511, 10.4103/JCD.JCD_450_20. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Ferreira E., Rosas C. A. P., and Limoeiro A., et al.Effect of Obturation Technique on Dentinal Tubule Penetration of Two Tricalcium Silicate-Based Sealers: Ex Vivo Study, Australian Endodontic Journal. (2024) 50, no. 1, 148–156, 10.1111/aej.12825. [DOI] [PubMed] [Google Scholar]
  • 35. Nakamura T., Tanaka H., and Kinuta S., et al.In Vitro Study on Marginal and Internal Fit of CAD/CAM All-Ceramic Crowns, Dental Materials Journal. (2005) 24, no. 3, 456–459, 10.4012/dmj.24.456. [DOI] [PubMed] [Google Scholar]
  • 36. Korsel A., Comparing of Marginal and Internal Fit of Monolithic Zircon Crown Fabricated by 3D Printed Die Versus Conventional, Egyptian Dental Journal. (2018) 64, no. 1, 811–820, 10.21608/edj.2018.78092. [DOI] [Google Scholar]
  • 37. Aboudorra H. A., Amr H., El Zohairy A., Hafez A., and Hassan A., Internal Fit Evaluation of all Ceramic Restoration Fabricated by Two CAD/CAM Milling Systems Using Cone Beam CT (CBCT), Egyptian Dental Journal. (2019) 65, no. 3, 2467–2479, 10.21608/edj.2019.72614. [DOI] [Google Scholar]
  • 38. Vasiliu R.-D., Porojan S. D., and Porojan L., In Vitro Study of Comparative Evaluation of Marginal and Internal Fit Between Heat-Pressed and CAD-CAM Monolithic Glass-Ceramic Restorations After Thermal Aging, Materials. (2020) 13, no. 19, 10.3390/ma13194239, 4239. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Nawafleh N. A., Mack F., Evans J., Mackay J., and Hatamleh M. M., Accuracy and Reliability of Methods to Measure Marginal Adaptation of Crowns and FDPs: A Literature Review, Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry. (2013) 22, no. 5, 419–428, 10.1111/jopr.12006. [DOI] [PubMed] [Google Scholar]
  • 40. Son K., Lee S., and Kang S. H., et al.A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses, Journal of Clinical Medicine. (2019) 8, no. 6, 1–17, 10.3390/jcm8060785. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41. Comlekoglu M., Dundar M., Özcan M., Gungor M., Gokce B., and Artunc C., Influence of Cervical Finish Line Type on the Marginal Adaptation of Zirconia Ceramic Crowns, Operative Dentistry. (2009) 34, no. 5, 586–592, 10.2341/08-076-L. [DOI] [PubMed] [Google Scholar]
  • 42. Shillinburg H. T., Jacobi R., and Brackett S. C., Fundamentals of Tooth Preparations for Cast Metal and Porcelain Restorations, 1991, Quintessence Publishing. [Google Scholar]
  • 43. El Eneen M. A., El-Naggar G., and Taymour M., Marginal Accuracy of Zirconium Reinforced Lithium Silicate (Vita Suprinity) Crowns With Two Marginal Designs Before and After Cementation Under Thermo Mechanical Cycling, International Journal of Applied Dental Sciences. (2019) 5, 382e390. [Google Scholar]
  • 44. Eldamaty M., Abdel-Aziz M., El-Kouedi A., and Hamza T., Effect of Finish Line Design and Cement Space Thickness on the Marginal Accuracy of Monolithic Zirconia Crowns, Brazilian Dental Science. (2020) 23, no. 3, 10.14295/bds.2020.v23i3.1908, 8p. [DOI] [Google Scholar]
  • 45. Nasir M. Q. and Kadhim A. J., Marginal Adaptation of Different Monolithic Zirconia Crowns With Horizontal and Vertical Finish Lines: A Comparative In Vitro Study, Journal of Dental Research, Dental Clinics, Dental Prospects. (2023) 17, 235–241. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Rizonaki M., Jacquet W., Bottenberg P., Depla L., Boone M., and De Coster P. J., Evaluation of Marginal and Internal Fit of Lithium Disilicate CAD-CAM Crowns With Different Finish Lines by Using a Micro-CT Technique, The Journal of Prosthetic Dentistry. (2022) 127, no. 6, 890–898, 10.1016/j.prosdent.2020.11.027. [DOI] [PubMed] [Google Scholar]
  • 47. Rungruanganunt P., Kelly J. R., and Adams D. J., Two Imaging Techniques for 3D Quantification of Pre-Cementation Space for CAD/CAM Crowns, Journal of Dentistry. (2010) 38, no. 12, 995–1000, 10.1016/j.jdent.2010.08.015. [DOI] [PubMed] [Google Scholar]
  • 48. ElGendy M., Sherif R., and Rabie K., Internal Fit and Marginal Adaptation of Posterior CAD/CAM Crowns Fabricated From Fully Crystallized Lithium Disilicate Compared to Partially Crystallized Lithium Disilicate With Two Finish Line Thicknesses: An In Vitro Study, The Journal of Contemporary Dental Practice. (2024) 25, no. 8, 740–744, 10.5005/jp-journals-10024-3744. [DOI] [PubMed] [Google Scholar]
  • 49. Baig M. R., Akbar A. A., and Embaireeg M., Effect of Finish Line Design on the Fit Accuracy of CAD/CAM Monolithic Polymer-Infiltrated Ceramic-Network Fixed Dental Prostheses: An In Vitro Study, Polymers. (2021) 13, no. 24, 10.3390/polym13244311, 4311. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Al-baadani A., Sherief R., and Kheireldean A., Evaluation of Internal Adaptation of Full Contour Zirconia Crowns Versus Veneered Zirconia Crowns-In Vitro Study, Egyptian Dental Journal. (2016) 62, no. 1, 717–719, 10.21608/edj.2016.95092. [DOI] [Google Scholar]
  • 51. Nassar H. and Abo El-Mal E., In Vitro Evaluation of the Marginal Adaptation of Monolithic Ceramic Crowns Fabricated With Different Margin Designs Using Novel CAD/CAM Material After Thermomechanical Aging, Egyptian Dental Journal. (2024) 70, no. 1, 575–585, 10.21608/edj.2023.256264.2830. [DOI] [Google Scholar]
  • 52. Hasanzade M., Sahebi M., Zarrati S., Payaminia L., and Alikhasi M., Comparative Evaluation of the Internal and Marginal Adaptations of CAD/CAM Endocrowns and Crowns Fabricated From Three Different Materials, The International Journal of Prosthodontics. (2021) 34, no. 3, 341–347, 10.11607/ijp.6389. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The datasets generated and analyzed during the current study are available from the corresponding author upon reasonable request.


Articles from International Journal of Dentistry are provided here courtesy of Wiley