Abstract
Accurate detection of arterial pulse waves is crucial for wearable warning systems but faces challenges under non-close contact or pre-stress. Here, an interfacial engineered triboelectric sensor (IETS) has been proposed to improve the detection accuracy of pulse waves. It consists of a stress-transferring sensor-skin interface with piezo-frustums array and a gradient triboelectric interface with mountain-like microstructures. The mountain-like microstructures provide stress concentration points even under a pre-stress of 10 kPa with capturing all details of the pulse waves. Additionally, the incorporation of piezo-frustums array at the sensor-skin interface not only facilitates stress transfer but also generates piezoelectric charges. Such mechano-electric coupling effect endows IETS with a high sensitivity of 4.28 V/kPa. Integrated with machine learning, a wearable system based on IETS allows for drivers’ health and fatigue assessment via pulse wave analysis, offering an effective approach to prevent road accidents caused by sudden cardiovascular diseases and fatigue driving.
Subject terms: Electrical and electronic engineering, Sensors
Introduction
Driver fatigue sudden cardiovascular diseases are the two leading causes of traffic fatalities1,2. Effective monitoring and timely warnings of driver’s physiological states are critical measures for reducing traffic accidents3. The non-invasive acquisition and analysis of pulse waves through wearable electronic devices can facilitate real-time management of cardiovascular health4–7. Optoelectronic devices are widely used in wearable pulse wave measurement, but their high power consumption and inability to obtain blood vessel pressure information limit their further development. Mechanical sensor-based pulse wave measurement systems have recently attracted extensive interest, which are capable of directly mapping the pulse waveform by monitoring the mechanical stimuli of arterial pulsations, more accurately reflecting vital cardiovascular health information such as arterial blood pressure and the elasticity of blood vessel walls8–10. However, the mechanical energy of pulse beats is extremely subtle and the real-time acquisition of accurate pulse wave throughout the day poses great challenges to sensitivity and the sensor’s power consumption11,12. Mechanical sensors based on piezoelectric and triboelectric principles, due to their zero power consumption and sensitive response to faint pressure signals, have been extensively used in real-time monitoring of pulse waves13–18. Recent work has found that triboelectric sensors exhibit a higher signal-to-noise ratio (SNR) when detecting faint mechanical physiological signals from the human body, such as heart sound19. Moreover, triboelectric sensors naturally can be made of a wide range of raw materials, thereby attracting extensive attention in recent years20,21.
To accurately reflect the details of the pulse wave, previous research primarily focused on constructing microstructures on the triboelectric layer surface to enhance the sensitivity of triboelectric sensors22–24. The contribution of microstructures to sensing performance mainly comes from two aspects: the increased surface area increases SNR and the stress concentration induced by microstructures enhances the sensitivity25. However, the regular microstructures are prone to reaching their deformation limits under high pressure, leading to a sharp decrease in sensor sensitivity at high pressures26–30. In real applications, a large pre-load stress is required in wearable electronics to make the close contact between the sensor and skin. The pre-stress from tightening the wristband or patch will significantly reduce the accuracy of the sensor in detecting pulse wave signals31. In addition, the gaps in the interface between the sensor and the skin could cause incomplete adhesion32,33, which results in non-effective transformation of faint pressure to the sensor’s active detection area, leading to a low SNR in the output signals. Therefore, improving the device’s sensitivity to weak pulse wave via interface engineering is also an urgent demand34,35.
In this work, we enhance the detection precision of pulse waves by triboelectric sensor through optimizing the stress transfer path and distribution at both the triboelectric interface and the sensor-skin interface. The piezo-frustums are used to fill the gaps at the sensor-skin interface, providing more pathways for the stress generated by pulse beats and simultaneously generate the piezoelectric charges. Through the mechano-electric coupling enhancement effect, it endows the interfacial engineered triboelectric sensor (IETS) with a high sensitivity of 4.28 V/kPa. Additionally, the design of mountain-like microstructures on the contact-electrification interfaces offer multiple stress concentration points, broadening the high-sensitivity response range until 12 kPa. IETS can detect pressure changes caused by the accumulation of water droplet weight (about 0.05 g) under a pre-stress of 5 kPa and it is able to clearly detect the detailed characteristics of pulse waves under a pre-stress of 10 kPa as well. Moreover, the IETS has a low detection limit of 2 Pa, a quick response time of 70 ms and a wide detection range up to 110 kPa. For the applications in preventing road accidents caused by sudden cardiovascular diseases and fatigue driving, a wearable tribo-electronic system has been constructed to collect and analyze the pulse wave signals of drivers in real-time. With the assistance of machine learning algorithms, the physiological data obtained from IETS can be effectively employed to assess the driver’s health and fatigue status.
Results and discussion
Structure and working mechanisms of the interfacial engineering-based triboelectric sensor (IETS)
During ventricular systole, the ejection of blood from the heart into the central and peripheral arteries induces a pulse wave. The real-time monitoring of mechanical information of pulse waves, such as amplitude and frequency, by using wearable sensors can enable applications such as early warning of cardiovascular diseases and assessment of fatigue states. As shown in Fig. 1a and Supplementary Fig. 1, by integrating triboelectric sensors into the wristband of a watch, the mechanical signals of pulse beats can be directly converted into electrical signals for output. After signal processing and Bluetooth module on the front side of the wristband, high-quality pulse wave signals will be sent to a mobile APP for real-time display. Machine learning algorithms in the back-end, by extracting and calculating the characteristic values of the pulse wave signals, can achieve the monitoring of the user’s cardiovascular health and fatigue state. Figure 1b illustrates the structure and equivalent circuit diagram of IETS. The device is composed of a triboelectric sensor with mountain-like triboelectric interface and a piezoelectric sensor with pillar-like sensor-skin interface. By sharing a common electrode to integrate these two kinds of sensors, it realizes aggregating charges on the common electrode from two sensors for amplifying the electrical signal. The working principle of the IETS is depicted in Supplementary Fig. 2. The triboelectric pressure sensor at the lower section is endowed with a specially designed mountain-like microstructures (Fig. 1c), which is constructed by the partial stacking of two conical microstructures with varying heights. The selection criteria for the silicone rubber-silver triboelectric pair are systematically presented in Supplementary Fig. S3. The working mechanism of the triboelectric sensor under different pressures is shown in Supplementary Figs. 4–6. Supplementary Note 1 provides a detailed discussion of the sensing mechanism of the triboelectric sensor under different pressures. The upper part of the IETS features a piezoelectric sensor whose primary component is a polymer-based piezoelectric material (PVDF) with frustums microstructure (Fig. 1d). The lower electrode of the piezoelectric sensor also serves as the upper electrode of the triboelectric sensor and the electrical coupling enhances the output signals. To minimize the impact of external factors, such as body sweat and wear, on the device’s performance, a polymer protective film has been applied to the surface of the piezoelectric sensor’s upper electrode through a spray coating process. The piezoelectric micropillars and mountain-like microstructures are vertically aligned in our design. The vertical alignment of piezoelectric micropillars with peak-like microstructures ensures direct stress transfer to triboelectric zones, avoiding signal loss in non-contact regions.
Fig. 1. Device structures and working mechanisms of interfacial engineering-based triboelectric sensor (IETS).
a Concept of a wearable wireless monitoring system based on highly sensitive IETS for pulse-wave detection. b Structure and equivalent circuit model of IETS. c Silicone rubber with mountain-like microstructures reversed through the carved PMMA mold (scale bar, 500 µm). d SEM image of piezo-frustums microstructures (scale bar, 500 µm). e Photograph of real testing scenario based on IETS for driver’s pulse wave monitoring. f Schematic illustration of the interfacial engineering. he left panel shows the challenges of traditional microstructures under a prestress. The right panel illustrates the working mechanism of the interfacial stress engineering. g Simulation results of sensor with and without interfacial stress optimization microstructures
Figure 1e presents a photograph of a wearable tribo-electronic system designed for driver fatigue and health monitoring. The exterior of the wristband is equipped with a flexible circuit board for signal processing and data transmission, while the interior of the wristband is secured with IETS. From a micro perspective, the human wrist is not an absolute plane. When the sensor contacts with the wrist, the traditional sensor with a smooth outer surface encounters recessed regions, preventing it from closely adhering to the skin, as depicted in left panel of Fig. 1f. The weak pulsation cannot effectively transfer mechanical energy to the device at these recessed interfaces, resulting in a low signal-to-noise ratio for the sensor. Additionally, the triboelectric interface with a regular structure tends to quickly reach its deformation limit under the action of external forces, leading to a rapid decline in the sensitivity of the triboelectric sensor in high pressure range. This work optimizes the transfer and distribution of stress through interface microstructures (right panel of Fig. 1f), achieving precise detection of pulse waves by IETS even under a pre-stress. The incorporation of the piezoelectric sensor not only enhances the output signal but also makes a significant positive contribution in terms of mechanical properties. Pillar-like microstructures, fabricated by a laser demolding technique, can closely adhere to the skin under the pre-tension of the wristband (Supplementary Figs. 7 and 8). These microstructures efficiently transfer the faint mechanical energy from pulse beats to the main body of IETS, generating a distinct electrical signal. Moreover, the piezoelectric microstructure themselves generate charge through the piezoelectric effect, serving dual roles in stress transfer and electrical signal enhancement. Figure 1g clearly illustrates the stress distribution of the device with and without the piezo-frustums microstructures. In areas where the wrist is recessed, stress cannot be effectively transmitted to the triboelectric sensor. However, with the presence of piezo-frustums microstructures, stress is efficiently conveyed to the sensor. For the triboelectric sensor, the larger the effective contact area, the higher for the output signal. Depressions at the skin-device interface leads to a reduction in the effective working area of the triboelectric sensor. The introduction of piezo-frustums microstructures allows for the effective transmission of pulse-induced stress at recessed areas, thereby increasing the effective working area of the triboelectric sensor. The triboelectric interface with mountain-like microstructures endows the sensor with high sensitivity under high pressure through multiple stress concentration points. Under a low pressure, the deformation is predominantly localized in the taller peak, which ensures the device’s high sensitivity for tiny pressure. With the application of a preload, the deformation capacity of the taller peaks is constrained after compression. The tips of the secondary peaks can provide the necessary deformation under this condition, ensuring the device’s high sensitivity under a greater pressure (Fig. S7, Supporting Information).
Mechanism of the laser-based microstructure fabrication method
In this work, we propose a method for preparing surface microstructures on the interface of polymer materials by using a CO2 laser to pattern etch PMMA substrate. Herein, the formation mechanism of the microstructures is further explained. The microscopic process of the CO2 laser acting on the PMMA substrate is depicted in Fig. 2a. According to the keyhole model, when the energy of the laser is absorbed by PMMA, a high temperature is instantly generated internally, as illustrated in Supplementary Note 2. When the temperature is higher than the vaporization point of PMMA, the intermediate PMMA vaporizes and evaporates, leaving cavities in the substrate36–38. Around the cavity, since the temperature is lower than the vaporization point of PMMA, the PMMA becomes a liquid molten pool. When the laser is turned off or moves away, the molten pool cools and becomes solid PMMA, leaving the middle hole structure (Supplementary Movie 1). The energy of the light beam emitted by the laser generally obeys a Gaussian distribution; thus the energy absorbed by PMMA also shows a Gaussian distribution in the irradiated area by the laser. Figure 2b shows the simulation and experimental results of the cavity depth in the PMMA substrate under different laser power conditions. When the distance between the laser head and the PMMA is fixed, the higher the laser power is, the deeper the cavity depth in the substrate. Figure 2c depicts the simulated temperature distribution in the substrate due to the Gaussian distribution of laser energy, resulting in a conical cavity morphology in PMMA. This enables indirect control of cone microstructure sizes by adjusting laser power to manipulate the temperature field. Figure 2d presents the relationship between the laser power and height of the conical microstructures. The higher the laser power is, the higher the height of the conical microstructures. Additionally, the conical microstructures created by laser etching are highly consistent due to the constancy of the laser power, as shown in Supplementary Fig. 9. Herein, a triboelectric layer with cone microstructures (width of 500 μm and height of 600 μm) is chosen as an example to analyze the deformation process under pressure. Supplementary Fig. 10 shows the deformation process of microstructures under certain pressures through simulation and experimental pressing tests. As the pressure increases, the vertical compression deformation of the cone microstructures increases. Due to the specific stress concentrations of the microstructures, the device deforms greatly, even under a low pressure. Different microstructures possess distinct stress concentration effects, thereby endowing the sensor with diverse sensing capabilities.
Fig. 2. Fabrication mechanisms of cone and mountain-like microstructures.
a Cone structure formation in a Poly (methyl methacrylate) (PMMA) substrate through a CO2 laser beam. b Simulation and fabrication results of cone structure formation in a PMMA substrate with different laser powers. The scale bar is 200 µm. c Simulated results of the laser energy distribution. d Correlation between cone height and laser power. e Fabrication mechanisms of mountain-like microstructures. The scale bar is 200 µm. f Simulation results of two kinds of microstructures deformation with an increasing pressure. g Large-area dielectric layer with mountain-like microstructures. The scale bar is 6 cm. The inset shows the microscopy picture of mountain-like microstructures. The scale bar is 500 µm. h Mechanical performance comparison of dielectric layers with different types of microstructures. i Output performance comparison of different types of nanogenerators
By designing various etching patterns, microstructures with different morphologies can be obtained. As depicted in Fig. 2e and Supplementary Fig. 11, when the laser etching pattern consists of two intersecting circles with one circle etched at a low power, mountain-like cavities with two apexes can be attained in the PMMA mold. In the subsequent replica molding process, the cavities can be filled with silicone rubber, thereby obtaining a mountain-shaped surface microstructure on the cured silicone rubber layer. By adjusting the laser power and the distance between the laser head and substrate, the mountain-like microstructure can exhibit the same height as the conical microstructure (Supplementary Fig. 12). Figure 2f presents a comparison of the displacement of the two types of microstructures under the same pressure through simulation. The mountain-like microstructure exhibits ~150 μm deformation under the same pressure, which is greater than that of the conical microstructure with same bottom diameter and same height. The outcome is mainly from the smaller volume of the mountain-like microstructure comparing to the conical microstructures of the same size to resist the applied external force. In addition, it has two peak structures at the top, which has a stronger stress concentration effect than the conical structure. This characteristic allows the microstructure to keep a large deformation capacity under high pressure without quickly reaching deformation saturation. Having greater deformation under high pressure implies that sensors with mountain-like microstructures maintain high sensitivity even under a pre-load stress. Figure 2g shows the potential for the large area fabrication of the mountain-like microstructures based on laser-etching processing, which also exhibits the capability for mass production of the IETS (Supplementary Figs. 13 and 14). Figure 2h shows the stress‒strain curves of different microstructures, further illustrating that the mountain-like microstructure can experience relatively great deformation under a large pressure. This result provides a mechanical basis for improving the sensitivities of triboelectric sensors under a prestress. To investigate the contribution of various interface structures to the output signal, the charge output of three kinds of devices is shown in Fig. 2i. A smooth acrylic plate was selected as the contact interface to avoid measurement errors caused by surface roughness. The test results indicate that the output signal is primarily provided by the TENG in the lower half of IETS. The contribution of the piezoelectric micropillars to the sensor mainly comes from their ability to enhance the stress transfer efficiency at the interface between the sensor and external objects. Concurrently, the piezoelectric micro-columns in the upper half also offer a portion of the electrical output, which is coupled with the signal of the TENG to enhance the signal-to-noise ratio.
Sensing performance of IETS
In order to authentically simulate the device’s response to pressure in a wearable scenario, the surface of a silicone rubber pad is etched using a laser to mimic the irregular curvature and roughness characteristic of the skin surface. For the testing procedure, the rough side of the silicone rubber pad is brought into close contact with the sensor, while a pressure gauge is utilized to exert force on the smooth side of the silicone rubber pad. As shown in Fig. 3a, the sensitivities of sensor with piezo-frustums microstructures are higher than those of devices with mountain-like and cone microstructures but without piezo-frustums. This is because the outer surface of the sensor without piezo-frustums is a smooth plane, when in contact with the roughness silicone pad, stress can be only transmitted through points of partial contact. This results in a smaller effective contact area at the triboelectric interface, thereby reducing the sensitivity of the triboelectric sensor. For IETS with both piezo-frustums and mountain-like microstructure, it exhibits the highest sensitivity of 4.28 V/kPa within the pressure range of 0-12 kPa and retains a high sensitivity of 0.18 V/kPa even under the pressure over 100 kPa. To further demonstrate the device’s pressure sensing capability across a wide pressure range, the sensor’s output voltages were measured under varying pressure conditions (50 kPa, 70 kPa, 90 kPa and 110 kPa), demonstrating maintained pressure resolution even under high-pressure conditions. Additionally, by placing the sensor on a volunteer’s heel and monitoring the voltage output during slow walking, the study provided further evidence of the sensor’s ability to detect pressure variations (Supplementary Fig. 15). The high sensitivity of IETS can be attributed to two aspects: the optimization of interfacial stress and the enhanced output signals by the coupling of piezoelectric and triboelectric effects. Interestingly, among devices with piezo-frustums, those with a mountain-like microstructure at the triboelectric interface exhibit higher sensitivity and a broader detection range under low pressure compared to those with conical structures. This is due to the stress concentration effect of the peak-like microstructures, which can produce large deformation, resulting in significant changes in contact area and gap distance. Overall, IETS with piezo-frustums and mountain-like microstructures have higher sensitivity and wider detection range, making it more suitable in the application that pre-load stress is required.
Fig. 3. Sensing performance characteristics of IETS.
a Sensitivity curves of the fabricated sensors with different structural features. b Correlation between the applied pressure and output voltage values of the IETS. c Limit of detection (LOD) value of the IETS. d Real-time signal change in the IETS generated by several successive water drops under a pre-load stress of 5 kPa. e Sensing performance comparison with recent works. f Responses of devices with different structural characteristics to a low pulse pressure under a preload of 10 kPa. The pulse waves detected by IETS feature more necessary physiological details
To investigate the influence of multi-peak microstructure shapes and peak number on sensor performance, finite element simulation and experiments are conducted as shown in Supplementary Fig. 16 and 17. For a given base diameter, pyramidal multi-peak microstructures undergo greater deformation than conical multi-peak microstructures under the same pressure, theoretically resulting in higher sensitivity. The number of peaks in multi-peak microstructures also significantly impacts sensor performance. Specifically, with a fixed base diameter, increasing the number of peaks enhances sensor sensitivity but correspondingly narrows the detection range.
As shown in Fig. 3b, as the pressure increases, the output voltage of the IETS also increases, showing a good correlation. Supplementary Fig. 18 shows the output response of device with mountain-like microstructures but without piezo-frustums under an increasing pressure. It also proves the ability of triboelectric sensor to distinguish pressure amplitude. To further demonstrate the potential of the sensors in pressure distribution monitoring, a 30 × 20 sensor array has been fabricated as shown in Supplementary Fig. 19. The results show that the sensor array could accurately detect both the position and intensity of finger presses. When a roll of tape was placed on the sensor array, the output pressure distribution image clearly reflected the outer contour of the tape, confirming its promising application in pressure distribution detection. To test the limit of detection (LOD) of the IETS at low pressures, sand paper with different sizes are used as pressure sources on the surface of the sensor. As shown in Fig. 3c, the test results show that when the sand paper weight is reduced to 4.19 mg, the IETS reaches its response limit, corresponding to an LOD of 2 Pa. To further test the device response to low pressures, different numbers of water drops (around 50 mg of each drop) are continuously dripped on a weight surface with 5 kPa at the same height. Figure 3d shows that the IETS is highly sensitive to low pressures even under a pre-load stress of 5 kPa and it can clearly detect the dripping and accumulation of water drops on the weight surface with a fast response time of 70 ms (Supplementary Fig. 20). In addition, the durability of the sensor is an important indicator affecting its actual service life. As shown in Supplementary Fig. 21, when a cyclic pressure of 2 kPa is applied to the surface of the sensor, the device does not show obvious signal attenuation after 5000 cycles, which indicates that the device has excellent durability. Moreover, the IETS can monitor static pressure of 2 kPa in real time and the static drift within 45 min is <15%, as shown in Supplementary Fig. 22. Under normal operating environments below 75 °C and 80% RH, the IETS demonstrates excellent stability (Supplementary Fig. 23). Upon comprehensive analysis, the interfacial stress engineering at the sensor-skin interface and the triboelectric interface significantly enhances sensing performance. Figure 3e presents a performance comparison between IETS and recently reported triboelectric and piezoelectric sensors in terms of sensitivity and detection range39–43. The reported IETS in this work possesses both high sensitivity and a broad detection range within a pressure range of <12 kPa. Although some previously reported triboelectric sensors have achieved higher sensitivity through stress concentration strategies, their high-sensitivity detection range is limited to below 7 kPa. By designing a mountain-like microstructure, the sensitivity and detection range of the sensor in this work are effectively ensured.
The pulse wave signal is an important indicator for cardiovascular health status and driver fatigue monitoring. The signal quality of the pulse wave directly determines the accuracy of the diagnosis. As shown in Fig. 3f, real-time monitoring characteristics of pulse waves from the same volunteer under a preload of 10 kPa during the same period by sensors with different microstructure types are compared. The results show that the IETS responds sensitively to pulse waves, and its output pulse wave signal has three obvious characteristic peaks. In contrast, the sensor with mountain-like microstructures but without piezo-frustums can just detect two characteristic peaks of the pulse wave. The device with 600 μm conical microstructures can just detect the main peak of the pulse wave, while the device without microstructures cannot effectively detect the pulse wave signal. The results for pulse wave monitoring demonstrate that the piezo-frustums and mountain-shaped microstructures can effectively improve the sensitivity of the triboelectric sensor and thus the IETS with piezo-frustums and mountain-shaped microstructures are selected in subsequent actual applications.
Applications of IETS in monitoring driver physiological signals and behaviors
To achieve real-time monitoring of driver’s health and fatigue state, the system has to obtain the pulse wave parameter of the driver in real time. Herein, the IETS is integrated into the strap of the smart watch and connected to the driver mobile terminal via a Bluetooth module to acquire and process pulse wave data. As shown in Fig. 4a, the sensor is integrated into a specific part of the strap so that the sensor is in close contact with the wrist artery when the watch is properly worn. When blood flow causes pulse beats in the artery, the highly sensitive sensor can capture these low-pressure signals in real time and convert them into electrical signals. The edge data processing module and Bluetooth module can process and send pulse wave data to the user mobile phone in real time. Figure 4b illustrates the schematic diagram of the real-time wireless pulse wave monitoring system based on IETS. Due to the low amplitude and frequency (<5 Hz) values of pulsation signals, this system is designed with unique amplification and filtering circuits. The pulse wave signal with a high signal-to-noise ratio is subsequently collected by an analog-to-digital converter (ADC) for initial shaping and feature extraction. The signal is then transmitted via Bluetooth to a mobile device for further analysis. Figure 4c presents the physical components of the hardware section of the system. Electronic components are integrated on a flexible circuit board, enabling the hardware system to bend and accommodate the users with various wrist shapes. When the complete hardware system is affixed to the surface of a cylindrical object with a radius of 2.5 cm, as shown in Fig. 4d, the system can continue to function as intended. Figure 4e displays the waveform of the pulse wave signal detected by IETS after undergoing analog signal processing. Evidently, the signal exhibits a high signal-to-noise ratio and can distinctly reflect information from multiple characteristic peaks. Figure 4f shows the Bluetooth connection interface on the mobile phone to prove the feasibility of the communication module. After the mobile phone and the sensor module successfully connect via Bluetooth, the sensor module can send preprocessed data to the mobile phone in real time and display the pulse waveform on the APP interface. This process provides a solid foundation for implementing subsequent eigenvalue extraction, frequency domain signal conversion and algorithms process. Figure 4g depicts the physical layout of the hardware system after the wristwatch strap is removed. Apparently, the sensor and flexible circuit board are installed on opposite sides of the strap that are interconnected by wires. Once the sensor and flexible circuit board are integrated with the wristwatch strap, the real-time collection of the driver pulse wave signal can be achieved, as shown in Fig. 4h. Assessing the driver fatigue level based on the pulse wave signal typically relies on indicators of heart rate variability (HRV). Figure 4i shows a conceptual diagram for calculating HRV. The core of HRV calculation is to obtain the time difference between two consecutive pulse beats. In practical measurement scenarios, the real-time collected pulse wave signal is a temporal signal. To effectively extract HRV parameters, the pulse wave signal is generally transformed into the frequency domain through fast Fourier transformation (FFT), as shown in Fig. 4j. In the frequency domain signal, the system can acquire parameters for each characteristic frequency and determine the volunteer fatigue state based on the proportion of these parameters3,44,45. As depicted in Fig. S18, noticeable distinctions in characteristic frequency parameters are observed for the same volunteer between wakeful morning and drowsy states. Additionally, based on the feature values in the temporal signal of the pulse wave, the system can assess the user cardiovascular health status. On this basis, we develop a driver fatigue and health status monitoring system, as demonstrated in Fig. 4k and Supplementary Fig. 24. By processing and analyzing the temporal and frequency domain signals of raw data, this system enables real-time monitoring and early warning of driver fatigue and physical health status (Supplementary Movie 2).
Fig. 4. Wireless driver fatigue monitoring system based on IETS.
a Schematic illustration of a smart strap with the IETS as a driver state monitor. b Schematic diagram of sensor signal acquisition and processing. c Photograph of the smart strap based on the IETS during the testing process. d Photograph of the smart strap during the bending state. e Real-time pulse wave detected by the oscilloscope to demonstrate the feasibility of the circuit during the bending state. f Photographs of the app for the Bluetooth module to verify the function of wireless communication. g Photograph of the IETS and the signal processing circuit without the strap. h Real testing scenario based on the proposed smart strap for driver fatigue monitoring. i Schematic illustration of HRV. j Frequency domain information of the real-time pulse wave signals monitored by the smart strap. k Photographs of the customized app for driver fatigue and health state monitoring
In addition, when a driver is tired, they may display irregular behaviors such as frequent abrupt braking and yawning due to distractions. The wearable sensors can be utilized to monitor these driver behaviors, providing an alternative method for assessing fatigue. On this basis, IETSs are wore on the driver face or attached on driving cab components, such as the accelerator and brake pedals, for the real-time collection of driver behaviors, as shown in Supplementary Fig. 25. Due to the high sensitivity of the IETS in a wide pressure range, the sensor can accurately detect both low pressure signals, such as eye movements, and large pressure signals, such as stepping on the brake pedals and the driver leaving the seat. As shown in Supplementary Fig. 26a, when a IETS is attached to the corner of the eye, blinking causes slight pressure changes due to contraction of the eye muscles. The sensor will clearly capture the driver blinking action. In a normal state, the frequency of driver blinking is maintained near a fixed value. In a state of fatigue, the driver usually experiences a period of first unblinking and then rapid blinking. The IETS can clearly monitor the driver blinking signal for the evaluation of the driver fatigue state. Similarly, the sensor can be attached to the driver’s mouth corner to monitor yawning. As shown in Supplementary Fig. 26b, when the driver is in a state of fatigue, yawning causes the mouth corner muscles to contract for usually 2–5 s, which is significantly different from normal talking and chewing actions. Therefore, monitoring driver yawning behaviors through the sensors can assist in evaluating the state of driver fatigue. In addition, installing sensors on the accelerator and brake pedals can also monitor driver actions in real time. As shown in Supplementary Fig. 26c, the driver’s behavioral data acquired by the IETS installed on the accelerator pedal show that when the vehicle starts, the output voltage of the sensor first slowly increases and then remains stable. When overtaking is needed, the force applied by the driver foot increases, the output voltage of the sensor increases as well. Similarly, the IETS attached to the brake pedal can provide real-time feedback on the changes in the force applied by the driver foot when braking. When the driver is in a state of fatigue, emergencies cause the driver to brake frequently and suddenly, and the sensor outputs sudden braking signals, as shown in Supplementary Fig. 26d.
Regarding to driver safety, IETSs can be integrated into seat belt buckles or cushions to determine whether the driver has fastened the seat belt or left the seat, respectively, by detecting changes in pressure (Supplementary Movie 3). As shown in Supplementary Fig. 26e, when the seat belt is fastened, the sensor in the buckle receives compression and outputs a continuous output signal. When the seat belt is released, the signal returns to the initial state. Supplementary Fig. S26f shows the output signal of the sensor under the seat cushion after being pressed by the driver weight. Upon the parallel integration of 12 IETSs to form an array device, the quantity of sensors under compression can be detected by assessing the magnitude of the output signal. This method allows for determination of the driver’s seating posture (Supplementary Fig. 27). The IETS can accurately detect whether the driver has seat or left the seat. These applications show that the sensor has an ultrawide detection range from low pressures, such as pulse waves, to large pressures, such as body weight.
Deep learning-enabled cardiovascular monitoring and driver fatigue monitoring
Biological signs can reliably indicate early fatigue and prevent accidents from occurring. Cardiovascular signals, such as electrocardiography (ECG) and photoplethysmography (PPG), can accurately monitor fatigue status. However, due to the limited viability of invasive sensors for real-time driver wear and the low sensitivity of noninvasive sensors influenced by humans or the environment, normal driver behavior and fatigue monitoring accuracy are compromised. Due to the high sensitivity in detecting imperceptible low pressures, the IETS can be used to monitor weak pulse waves to continuously assess cardiovascular and fatigue conditions. Moreover, a combination of artificial intelligence (AI), such as deep learning, can improve the accuracy and actionability of new sensing devices, ultimately facilitating real-time personal identification and driver fatigue (Fig. 5a). By comparing the voltage signal obtained by IETS with the typical arterial pulse wave in Fig. 5b, we find that the voltage signal matches the typical arterial pulse waveform and can detect low intra-arterial blood pressure oscillations with systolic, reflected and diastolic peaks (P1, P2 and P3). These peaks can also be used to further calculated the detail feature parameters for artery evaluating. Parameters such as diastolic blood pressure, systolic blood pressure and blood flow velocity shown in the diagram can be used to accurately predict the user’s cardiovascular status through cloud-based algorithms, enabling early warning of sudden cardiovascular disease. Therefore, the cardiovascular condition and degree of arteriosclerosis can be assessed by comparing the measured results with references.
Fig. 5. Demonstrations of the IETS in cardiovascular and driver fatigue monitoring processes.
a Illustration of deep learning-enabled personal identification, driver fatigue monitoring and pulse monitoring, with the detailed framework of 1D-CNN analytics. b Schematic diagram of a typical pulse wave. c RWTT and PPT acquired from a continuous pulse signal during 20 cycles. d Poincare plot for the nonfatigue and fatigue states of a healthy person. e Frequency domain distribution chart under nonfatigue and fatigue states. f–h Heart rate distribution and real-time output of IETS in a regular state. i–k Heart rate distribution and real-time output of IETS when the wearer is fatigued. l Confusion map for the 1D-CNN outcome of 2 states from one subject
Figure 5c and Supplementary Fig. 28 show the reflected wave transit time (RWTT), systolic–diastolic time (PPT), upstroke time (UT) and left ventricular ejection time (LVET) from the continuous 20 voltage signal cycles, all of which are correlated with the reported reference values of a healthy individual. Cardiovascular conditions are related to heart rate (HR) and HRV. Figure 5 d reflects a mapped scatter points plot of pulse interval (Ti) to reflect the HRV when the subject is nonfatigued (HRV = 8.9) and fatigued (HRV = 5.4); HRV is a valuable predictor of sudden cardiac death and arrhythmic events. The lower the HRV value is, the more likely the subject is to suffer from acute myocardial infarction and arrhythmias, and the stronger the need to relax and rest in a timely manner. Moreover, the frequency–time distribution chart (Fig. 5e) illustrates that when the subject is fatigued, the frequency change over time is unstable, aiding in demonstrating the instability of heart rate variability during fatigue. Heart rate decreases significantly in the fatigued state of the subject, as shown in Fig. 5f–j. The heart rate and HRV index in pulse wave signals are crucial physiological indicators for evaluating fatigue. However, this method requires long-term pulse wave data, which cannot monitor and assess the driver fatigue status and alert the driver in real time. Thus, in this study, the pulse wave data are divided into time lengths of 750 ms per sample, and the short-term signals are classified by a one-dimensional (1 d) convolutional neural network (CNN)-based method for recognizing driver behavior and fatigue. To reduce the effects of noise, baseline drift and environment, the collected data are preprocessed (wavelet noise reduction, R-peak splitting and normalization, respectively). The detailed framework and parameters used to construct the CNN model are labeled in Supplementary Table 1. Supplementary Fig. 29 supplies the typical pulse signals of the 5 different subjects. Through data collection and signal preprocessing, 625 sample data points with each 750 data points constitute dataset 1 (80% training set and 20% test set). The average recognition accuracy is 94% (Supplementary Fig. 30a), providing great potential for high-accuracy behavioral recognition based on deep learning (DL) prediction. After training in the 1d-CNN model with 80 training epochs, the maximum accuracy is achieved, and the dropout layer avoids overfitting, as shown in Supplementary Fig. 30b. In contrast to unprocessed data and support vector machine (SVM) models, which require pre-extracted features, the end-to-end CNN model exhibits increased accuracy and reduced overall complexity in Supplementary Fig. 30c.
Pulse signal-based identification technology avoids the drawbacks of traditional identity authentication and is less susceptible to copying and counterfeiting. Combining it with deep learning networks increases the convenience and effectiveness of identification. As depicted in Fig. 5h, k, the morphology of the pulse changes after fatigue, with reflected and diastolic peaks decreasing relative to the systolic peaks. By merging the data of the different states for several days, dataset 2 is trained and validated by the deep learning network described above. The average accuracy reaches 98% for one subject, as shown in Fig. 5 l. Fatigue classification based on short-time pulse signals can achieve the real-time and accurate detection of driver fatigue, providing a certain guarantee for safe driving.
Discussion
In conclusion, this work presents an interfacial engineering-based triboelectric sensor (IETS) to realize the precise pulse wave detection. The integration of piezo-frustums at the sensor-skin interface not only provides the pathways for stress transfer but also facilitates the generation of piezoelectric charges. Through the mechano-electric coupling effect, the sensitivity of IETS has been improved by 5 times compared to devices without piezo-frustums, reaching 4.28 V/kPa. Additionally, the construction of mountain-like microstructures at triboelectric interface has further expanded the sensor’s high-sensitivity response range to 12 kPa, enabling the clear detection of pulse wave characteristics under a pre-stress of 10 kPa. Simultaneously, IETS has a low detection limit of 2 Pa, a quick response time of 70 ms and a wide detection range reaching 110 kPa. Furthermore, the development of a wearable tribo-electronic system, supported by machine learning algorithms, allows for real-time collection and analysis of driver’s pulse wave signals, providing a robust tool for assessing health and fatigue status, thereby contributing to the prevention of road accidents associated with cardiovascular diseases and fatigue driving. This study demonstrates the potential of interface stress engineering for enhancing the performance of wearable sensing systems, providing a viable solution for accurate pulse wave measurement under prestress conditions.
Methods
Fabrication of the interfacial engineering-based triboelectric sensor (IETS)
The fabricated IETS consists of a piezoelectric nanogenerator-based sensor (PENG) and a triboelectric nanogenerator-based sensor (TENG). The TENG is composed of upper and bottom electrodes and a microstructured triboelectric layer. The bottom electrode is formed by screen printing silver paste (01 L-2211D, Sryed Paste) on a polyethylene terephthalate (PET) substrate. Specifically, through the extrusion of the scraper, the silver paste passes through the customized pattern mesh plate to form a conductive circuit on the PET surface and is then cured at 120 °C to fabricate flexible electrodes. To obtain the microstructured triboelectric layer, components A and B of Ecoflex (00-30, Smooth-On) are mixed evenly in a 1:1 ratio and spin-coated on the PMMA mold. Then the layer is left in a vacuum drying oven for ~2 h until it is fully cured. The PMMA mold uses the Gaussian distribution of laser energy to form a microstructure pattern inside the PMMA. By adjusting the power and motion modes of the laser machine, microstructures with different sizes and shapes can be obtained. To fabricate the consistent cone microstructures, the laser power at 9.5 W was fixed. When the laser etching pattern consists of two intersecting circles with one circle etched at 9.3 W power and another etched at 9.5 W, mountain-like cavities with two apexes can be attained in the PMMA mold. By sequentially bonding the lower electrode, triboelectric layer and upper electrode with 3 M double-sided tape (3MVHB4905, 3 M), a triboelectric pressure sensor can be obtained. Similarly, triboelectric sensors with different shapes and sizes can be prepared by designing different electrode patterns.
The piezo-pillar microstructures are also fabricated using a demolding method. To acquire high-quality microstructures, a PMMA mold with a cylindrical structure is first etched using a laser. Subsequently, a second mold is formed by casting PDMS over the PMMA mold. PVDF (Polyk-Piezo) powder is dissolved in acetone at a weight ratio of 3:7, then poured into the PDMS mold to replicate the cylindrical piezoelectric microstructures. Silver electrodes are fabricated on their base using a screen printing method. The piezoelectric performance of the material is enhanced through high-voltage polarization, followed by the sputtering of a gold electrode layer on the upper surface using a magnetron sputtering process. Finally, after the integration with the triboelectric sensor, a polymer layer is sprayed as a protective coating.
Performance characterization
For the electrical output measurement of the IETS, an external contact force is applied by a commercial linear mechanical motor (Winnemotor, WMUC512075-06-X) and the applied force is detected by digital force measurement (Chatillon, DFS Ⅱ). A programmable electrometer (Keithley model 6514) is used to test the electrical output signal. The triboelectric potential distribution simulation and mechanical deformation are conducted by COMSOL Multiphysics software. The silicone rubber has a Poisson’s ratio of 0.48, a Young’s modulus of 2.5E3 kPa, and a density of 1.15 g/cm3.
Supplementary information
Acknowledgements
This work was supported by the National Key R&D Program of China (No. 2023YFB3208100), the National Natural Science Foundation of China (No. 62522407, No. 62174115, No. 62273247), the Natural Science Foundation of the Jiangsu Higher Education Institutions of China Program (No. 19KJB510059), Suzhou Science and Technology Development Planning Project: Key Industrial Technology Innovation (No. SYG202009, No. SYG201924), Jiangsu Key Laboratory for Carbon-based Functional Materials & Devices, Soochow University (No. KJS2157), XJTLU Research Development Fund (No. RDF-17-01-13, No. RDF-21-02-068 and No. RDF-22-01-110) and SIP AI innovation platform (No.YZCXPT2022103). This work was partially supported by the Collaborative Innovation Center of Suzhou Nano Science & Technology, 111 Project, Joint International Research Laboratory of Carbon-Based Functional Materials and Devices, XJTLU AI University Research Centre, Jiangsu Province Engineering Research Centre of Data Science and Cognitive Computation at XJTLU.
Author contributions
H.L. and Z.W. conceived the idea, H.L., X.Q., and G.S. analyzed the data and contributed to writing the paper. P. H. and G.S. designed the microstructure of the sensors. W.W., J.Y. and L.X. developed and fabricated the circuit board. L.X., and B.L. constructed the app and machine learning algorithm. H.L., X.Q., and G.S. conducted the experiments to fabricate the sensors. H.L., Y.L., E.G.L. and X.T. created and optimized the figures, tables, and videos. C. Z., X. S. and Z. W. revised the manuscript. All authors collectively analyzed the results and implications and provided comments on the manuscript at all stages.
Data availability
All data supporting this study and its findings are available within the article, its Supplementary Information and associated files. The source data are available from the corresponding author upon reasonable request.
Competing interests
The authors declare no competing interests.
Footnotes
These authors contributed equally: Hao Lei, Lingjie Xie, and Xuan Qin
Contributor Information
Chun Zhao, Email: chun.zhao@xjtlu.edu.cn.
Xuhui Sun, Email: xhsun@suda.edu.cn.
Zhen Wen, Email: wenzhen2011@suda.edu.cn.
Supplementary information
The online version contains supplementary material available at 10.1038/s41378-025-01107-x.
References
- 1.Feng, S. et al. Dense reinforcement learning for safety validation of autonomous vehicles. Nature615, 620–627 (2023). [DOI] [PubMed] [Google Scholar]
- 2.Spatz, E. S., Ginsburg, G. S., Rumsfeld, J. S. & Turakhia, M. P. Wearable digital health technologies for monitoring in cardiovascular medicine. N. Engl. J. Med.390, 346–356 (2024). [DOI] [PubMed] [Google Scholar]
- 3.Pham, T., Lau, Z. J., Chen, S. H. A. & Makowski, D. Heart rate variability in psychology: A review of HRV indices and an analysis tutorial. Sensors21, 3998 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Bayoumy, K. et al. Smart wearable devices in cardiovascular care: where we are and how to move forward. Nat. Rev. Cardiol.18, 581–599 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Ates, H. C. et al. End-to-end design of wearable sensors. Nat. Rev. Mater.7, 887–907 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Kim, S. et al. Wearable and implantable bioelectronics as eco-friendly and patient-friendly integrated nanoarchitectonics for next-generation smart healthcare technology. EcoMat5, e12356 (2023). [Google Scholar]
- 7.Lee, H. et al. Toward all-day wearable health monitoring: an ultralow-power, reflective organic pulse oximetry sensing patch. Sci. Adv.4, eaas9530 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Chen, S. et al. Flexible Wearable Sensors for Cardiovascular Health Monitoring. Adv. Healthc. Mater.10, 2100116 (2021). [DOI] [PubMed] [Google Scholar]
- 9.Zhao, L. et al. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. npj Digit. Med.6, 93 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A. & Asghar, W. Advances in healthcare wearable devices. npj Flex. Electron.5, 9 (2021). [Google Scholar]
- 11.Meng, K. et al. Wearable pressure sensors for pulse wave monitoring (Adv. Mater. 21/2022). Adv. Mater.34, 2270158 (2022). [DOI] [PubMed] [Google Scholar]
- 12.Guan, Y.-S. et al. Elastic electronics based on micromesh-structured rubbery semiconductor films. Nat. Electron.5, 881–892 (2022). [Google Scholar]
- 13.Li, J. et al. Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure. Nat. Commun.14, 5009 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Tian, G. et al. Hierarchical piezoelectric composites for noninvasive continuous cardiovascular monitoring. Adv. Mater.36, 2313612 (2024). [DOI] [PubMed] [Google Scholar]
- 15.Yi, Z. et al. Piezoelectric dynamics of arterial pulse for wearable continuous blood pressure monitoring. Adv. Mater.34, 2110291 (2022). [DOI] [PubMed] [Google Scholar]
- 16.Chorsi, M. T. et al. Highly piezoelectric, biodegradable, and flexible amino acid nanofibers for medical applications. Sci. Adv.9, eadg6075 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Yao, C. et al. Personalized machine learning-coupled nanopillar triboelectric pulse sensor for cuffless blood pressure continuous monitoring. ACS Nano17, 24242–24258 (2023). [DOI] [PubMed] [Google Scholar]
- 18.Peng, X. et al. A breathable, biodegradable, antibacterial, and self-powered electronic skin based on all-nanofiber triboelectric nanogenerators. Sci. Adv.6, eaba9624 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Hui, X. et al. Acoustically enhanced triboelectric stethoscope for ultrasensitive cardiac sounds sensing and disease diagnosis. Adv. Mater.36, 2401508 (2024). [DOI] [PubMed] [Google Scholar]
- 20.Fan, W. et al. Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring. Sci. Adv.6, eaay2840 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Khandelwal, G. & Dahiya, R. Self-powered active sensing based on triboelectric generators. Adv. Mater.34, 2200724 (2022). [DOI] [PubMed] [Google Scholar]
- 22.Lee, S. & Park, J.-W. Fingerprint-inspired triboelectric nanogenerator with a geometrically asymmetric electrode design for a self-powered dynamic pressure sensor. Nano Energy101, 107546 (2022). [Google Scholar]
- 23.Liu, W. et al. Touchless interactive teaching of soft robots through flexible bimodal sensory interfaces. Nat. Commun.13, 5030 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Meng, K. et al. Kirigami-inspired pressure sensors for wearable dynamic cardiovascular monitoring. Adv. Mater.34, 2202478 (2022). [DOI] [PubMed] [Google Scholar]
- 25.Zhang, Z. et al. Artificial intelligence of toilet (AI-Toilet) for an integrated health monitoring system (IHMS) using smart triboelectric pressure sensors and image sensor. Nano Energy90, 106517 (2021). [Google Scholar]
- 26.Yang, Y. et al. Triboelectric nanogenerator enabled wearable sensors and electronics for sustainable internet of things integrated green earth. Adv. Energy Mater.13, 2203040 (2023). [Google Scholar]
- 27.Sun, Z., Zhu, M., Shan, X. & Lee, C. Augmented tactile-perception and haptic-feedback rings as human-machine interfaces aiming for immersive interactions. Nat. Commun.13, 5224 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Bai, N. et al. A robotic sensory system with high spatiotemporal resolution for texture recognition. Nat. Commun.14, 7121 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Liu, Y. et al. Electronic skin as wireless human-machine interfaces for robotic VR. Sci. Adv.8, eabl6700 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Shi, J. et al. Embedment of sensing elements for robust, highly sensitive, and cross-talk–free iontronic skins for robotics applications. Sci. Adv.9, eadf8831 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Fang, Y. et al. Ambulatory cardiovascular monitoring via a machine-learning-assisted textile triboelectric sensor. Adv. Mater.33, 2104178 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Liu, X. et al. Bioinspired, microstructured silk fibroin adhesives for flexible skin sensors. ACS Appl. Mater. Interfaces12, 5601–5609 (2020). [DOI] [PubMed] [Google Scholar]
- 33.Tang, L., Shang, J. & Jiang, X. Multilayered electronic transfer tattoo that can enable the crease amplification effect. Sci. Adv.7, eabe3778 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Min, S. et al. Clinical validation of a wearable piezoelectric blood-pressure sensor for continuous health monitoring. Adv. Mater.35, 2301627 (2023). [DOI] [PubMed] [Google Scholar]
- 35.Park, J. et al. Frequency-selective acoustic and haptic smart skin for dual-mode dynamic/static human-machine interface. Sci. Adv.8, eabj9220 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Cao, X., Wallace, W., Poon, C. & Immarigeon, J.-P. Research and progress in laser welding of wrought aluminum alloys. I. Laser Weld. Process. Mater. Manuf. Process.18, 1–22 (2003). [Google Scholar]
- 37.Svenungsson, J., Choquet, I. & Kaplan, A. F. H. Laser welding process – a review of keyhole welding modelling. Phys. Procedia78, 182–191 (2015). [Google Scholar]
- 38.Yang, R. et al. Author correction: iontronic pressure sensor with high sensitivity over ultra-broad linear range enabled by laser-induced gradient micro-pyramids. Nat. Commun.14, 3913 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Zu, L. et al. Multiangle, self-powered sensor array for monitoring head impacts. Sci. Adv.9, eadg5152 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Xie, L. et al. Ultrasensitive wearable pressure sensors with stress-concentrated tip-array design for long-term bimodal identification. Adv. Mater. 36, 2406235 (2024). [DOI] [PubMed]
- 41.Ha, M. et al. Skin-inspired hierarchical polymer architectures with gradient stiffness for spacer-free, ultrathin, and highly sensitive triboelectric sensors. ACS Nano12, 3964–3974 (2018). [DOI] [PubMed] [Google Scholar]
- 42.Lu, J. et al. A biodegradable and recyclable piezoelectric sensor based on a molecular ferroelectric embedded in a bacterial cellulose hydrogel. ACS Nano16, 3744–3755 (2022). [DOI] [PubMed] [Google Scholar]
- 43.Park, Y. et al. Ferroelectric multilayer nanocomposites with polarization and stress concentration structures for enhanced triboelectric performances. ACS Nano14, 7101–7110 (2020). [DOI] [PubMed] [Google Scholar]
- 44.Gao, R. et al. Study on the nonfatigue and fatigue states of orchard workers based on electrocardiogram signal analysis. Sci. Rep.12, 4858 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Ahmed, S. et al. Noncontact assessment for fatigue based on heart rate variability using IR-UWB radar. Sci. Rep.12, 14211 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data supporting this study and its findings are available within the article, its Supplementary Information and associated files. The source data are available from the corresponding author upon reasonable request.