Skip to main content
. 2003 Sep;85(3):1725–1733. doi: 10.1016/S0006-3495(03)74602-5

TABLE 1.

Occurrence of leakage and flicker in different cell systems

Model system T, °C Number of experiments Number of experiments where fusion was detected (complete fusions* + noncomplete fusions) Number of experiments with flicker (among those with leakage) Incidence of leakage: number of experiments with leakage/number of fusions Number of leakages resealed
HAb2/RBC 33 14 12 (9 + 3) 4 (4) 7/12 7
HAb2/RBC 22 17 12 (0 + 12) 10 (10) 10/12 6
HAb2/BLM 37 15 12 (12 + 0) 12 (10) 10/12 2
HAb2/PLC 22 27 11 (8 + 3) 9 (8) 8/11 7
Total 73 47 (29 + 18) 35 (32) 35/47 22
*

ΔIm reached plateau (HAb2/RBC and HAb2/BLM) or Gp reached 20 nS (HAb2/PLC).

Fusion pore closed completely at least once.

After the completion of fusion Gdc < 4 nS.