Skip to main content
. 2004 Apr;86(4):2231–2237. doi: 10.1016/S0006-3495(04)74281-2

TABLE 1.

The mean conductance fitted by Gaussian distribution (Λc), the occurrence (channels/min), the fitted lifetimes (see text) of the single-channel events (s), the significant F-test (P) of the lifetimes, and the total number (Nt) of AβP (1–40) channels in different PLMs at different applied potentials

PLM V (mV) Λc (nS) ± SD Occurrence ± SD τ1(s) τ2(s) P Nt
DOPS:DOPE 60 0.700 ± 0.30 5.62 ± 0.14 1.29 1650
POPC:Ch 80 0.013 ± 0.01 0.50 ± 0.04 0.99 129
100 0.018 ± 0.01 1.22 ± 0.12 0.20 2.60 108
120 0.016 ± 0.01 2.97 ± 0.30 2.45 0.13 107
POPC:Erg 120 0.015 ± 0.00 3.13 ± 0.12 3.80 0.65 631
7-DHC 40 0.062 ± 0.04 7.91 ± 0.41 4.01 372
20 0.081 ± 0.04 3.68 ± 0.11 4.54 0.79 1164
−20 0.090 ± 0.03 4.42 ± 0.15 4.35 0.65 508
−40 0.040 ± 0.03 2.40 ± 0.18 2.81 0.58 176
OxCh 120 0.072 ± 0.03 4.23 ± 0.15 1.44 8.90 748
100 0.095 ± 0.04 3.23 ± 0.20 1.98 0.23 272
80 0.100 ± 0.06 1.82 ± 0.08 2.57 464
60 0.120 ± 0.06 1.51 ± 0.05 0.16 3.33 724
40 0.160 ± 0.10 2.32 ± 0.09 0.40 5.26 611
20 0.540 ± 0.42 2.97 ± 0.06 0.40 3.02 2080
−20 0.980 ± 0.43 4.68 ± 0.17 1.71 791
−40 0.180 ± 0.10 3.33 ± 0.12 4.00 0.34 751
−60 0.170 ± 0.08 3.10 ± 0.09 3.70 0.12 1071
−80 0.110 ± 0.06 3.82 ± 0.22 1.65 12.38 284
−100 0.102 ± 0.07 2.99 ± 0.25 2.14 0.14 140
−120 0.063 ± 0.05 7.94 ± 0.44 2.25 0.12 329