TABLE 2.
Averaged fitted parameter values from 12 preparations from the region 7–8 mm from the round window—the second turn of the cochlea
| N | c1 | c2 | c3 | c4 | k | c5 | |
|---|---|---|---|---|---|---|---|
| ISC | 10 | 45.8 | 5.99 × 10−6 | 6.98 × 10−7 | 1.181 × 10−4 | 0.0197 | 1.31 × 10−6 |
| IHC | 13 | 194 | 1.76 × 10−5 | 3.59 × 10−6 | 3.341 × 10−4 | 0.174 | 5.46 × 10−6 |
| ToC | 14 | 416 | 2.61 × 10−5 | 1.04 × 10−5 | 8.494 × 10−6 | 0.428 | 9.24 × 10−6 |
| 1st OHC | 13 | 90.7 | 8.69 × 10−6 | 5.11 × 10−6 | 3.136 × 10−5 | 0.149 | 2.52 × 10−6 |
| 2nd OHC | 15 | 20.8 | 6.59 × 10−6 | 8.34 × 10−7 | 5.432 × 10−5 | 0.0480 | 5.82 × 10−7 |
| 3rd OHC | 15 | 23.5 | 4.44 × 10−6 | 1.00 × 10−6 | 1.551 × 10−4 | 0.0326 | 5.92 × 10−7 |
| OT | 10 | 16.1 | 4.47 × 10−6 | 0 | * | 0.0296 | 5.44 × 10−7 |
| HeC | 17 | 26.0 | 3.27 × 10−6 | 0 | * | 0.0361 | 3.22 × 10−7 |
Acronyms and notations as in Table 1.