Skip to main content
. 2004 Aug;87(2):1378–1391. doi: 10.1529/biophysj.103.037184

TABLE 3.

Averaged fitted parameter values from nine preparations from the region 12–13 mm from the round window: the third turn of the cochlea

N c1 c2 c3 c4 k c5
ISC 6 16.3 1.01 × 10−5 0 * 0.0255 0
IHC 7 118 1.95 × 10−5 0 * 0.191 3.46 × 10−6
ToC 7 321 3.35 × 10−5 4.23 × 10−6 2.221 × 10−5 0.307 9.92 × 10−6
1st OHC 7 99.3 1.36 × 10−5 6.02 × 10−6 2.502 × 10−5 0.201 3.54 × 10−6
2nd OHC 7 51.4 8.35 × 10−6 0 * 0.0795 1.02 × 10−6
3rd OHC 6 11.6 6.84 × 10−6 0 * 0.0551 1.25 × 10−7
OT 6 0 6.22 × 10−6 0 * 0.0190 − 3.83 × 10−7
HeC 7 47.1 4.81 × 10−6 0 * 8.59 × 10−3 − 2.37 × 10−7

Acronyms and notations as in Table 1. Notice the negative values for c5 on the outer tunnel and Hensen's cells—this indicates a measurable inertial component.