Skip to main content
. 2004 Aug;87(2):958–973. doi: 10.1529/biophysj.103.036350

TABLE 2.

Single channel permeabilities (×10−10 mm3/s) for Alexa dyes through homotypic and heterotypic gap junction channels

Cx 350* 488* 594*
26 2.5 ± 0.5 (8) 2.8 ± 1.5 (6) 0.13 ± 0.05 (10)
32 3.1 ± 0.8 (15) 3.3 ± 0.8 (15) 1.6 ± 0.4 (10)
37 1.2 ± 0.3 (3) 0.6 ± 0.1 (4) ND (6)
40 4.4 ± 1.2 (8) 3.6 ± 0.9 (4) 0.10 ± 0.01 (4)
43 2.4 ± 0.3 (6) 4.8 ± 1.0 (7) 1.2 ± 0.2 (8)
45 7.3 ± 1.5 (6) 3.3 ± 0.0 (2) 0.16 ± 0.05 (13)
26/32 2.4 ± 0.8 (4) 3.4 ± 1.0 (8) 0.31 ± 0.08 (13)
32/26 2.3 ± 0.2 (2) 3.9 ± 0.7 (4) 0.27 ± 0.10 (3)
37/43 2.0 ± 0.4 (3) NT 0.07 (1)
43/37 2.0 ± 0.1 (4) 0.9 ± 0.3 (3) 0.09 ± 0.03 (3)

ND, not detected; NT, not tested. Number of data sets used in calculating permeability shown in parentheses.

*

Mean ± SE of (AP)pore (units of 10−10 mm3/s).