Quantifying the biological impacts of nightlights: implications for sleep and circadian health in children

Gena L Glickman 1,, Rebecca Rothstein-Epp 2, Kyle Binkowski 1, Sebastian M M Preilipper 1,3, Ava Santiago 4, Sara C Bessman 1,3, Alexandra Easterling 1,3, Elizabeth M Harrison 1,3,
PMCID: PMC13046988  PMID: 41927975

Abstract

Given the widespread use of nightlights, we characterized an assortment of popular products to evaluate their potential to disrupt sleep and circadian rhythms in children. Spectral irradiance was measured for 25 top-rated nightlights (79 settings) under laboratory (source-level) and simulated bedroom (typical use) conditions. Nightlights varied in form (handheld, projector, tabletop, wall plug-in) as well as intensity and color settings. Melanopic equivalent daylight illuminance (EDI) estimated circadian input and was compared against biologically relevant thresholds for pediatric sleep. Across conditions, melanopic EDI values spanned several orders of magnitude, from 0 lx to >100,000 lx, with some devices varying substantially by setting. With source-level characterizations, only 3/25 products consistently remained below 5 lx melanopic EDI (levels known to phase shift circadian rhythms and suppress melatonin in children), and 2 also met the <1 lx consensus nighttime recommendation for adults. Under typical-use conditions, 14/25 products remained below 5 lx melanopic EDI (11 were <1 lx) on at least one setting, with most being red-toned, low-intensity, and positioned farther from the bed, though many of those would not support vision. Clear clinical guidance, public health recommendations, and improved product labeling standards are needed to reduce circadian disruption and promote healthier sleep in children.

Subject terms: Health care, Neuroscience, Physiology

Introduction

Children are routinely exposed to nighttime light levels far exceeding those found in nature, with significant implications for sleep and circadian health. Nighttime illumination from natural sources, such as moonlight and stars, typically measures below 1 lux (lx), several orders of magnitude dimmer than direct sunlight. The human circadian system evolved under these stark day-night contrasts, yet modern electric lighting disrupts natural cues, contributing to adverse health outcomes, including sleep disturbance, mood disorders, and metabolic dysfunction1.

Many children spend daytime hours indoors under electric lighting and remain exposed to ambient light well into the evening. Evening light exposure, particularly from electronic screens (typically 10–100 lx), has been linked to delayed sleep onset and reduced sleep duration, prompting recommendations to limit screen use before bedtime2,3. Nevertheless, a substantial proportion of children sleep in illuminated environments; one study found 39% of kindergarten children slept with room lights on and 50% used a nightlight4. These lighting practices, intended for comfort or safe navigation, may suppress nocturnal melatonin and alter circadian timing, negatively impacting sleep1. Sleep disturbances affect up to 30% of preschool-aged children5 and are associated with long-term effects on health, learning, and development6. Thus, evening and nighttime light exposure represents a critical yet often overlooked factor in pediatric sleep health.

While light is essential for vision, it also regulates non-visual physiological processes, including circadian rhythms, melatonin secretion, and alertness. Perceived brightness does not always reflect biological impact because non-visual responses are mediated by intrinsically photosensitive retinal ganglion cells (ipRGCs) that contain melanopsin, distinct from the rods and cones used for vision7,8. These ipRGCs project to the suprachiasmatic nucleus in the hypothalamus, the central circadian pacemaker, influencing neuroendocrine and behavioral rhythms1,79.

Because of this physiology, responses to light depend on timing, intensity, spectral composition, and spatial distribution. Light exposure in the early biological night can delay circadian rhythms, acutely suppress the nocturnal hormone melatonin, and disturb sleep. These effects are amplified with higher intensity and greater short-wavelength (blue) content1013. White lights that appear visually similar may also have dramatically different physiological effects, depending on spectral content14. As a consequence, the biological potency of light for non-visual responses is quantified via melanopic equivalent daylight illuminance (melanopic EDI), which weights intensity according to the melanopsin absorption curve15,16. In adults, half-maximal circadian phase shifting and melatonin suppression occur with melanopic EDI of approximately 25–70 lx, based on a meta-analysis of multiple studies, including the primary study by Zeitzer et al. that was originally reported in photopic terms9,17. Consensus guidelines recommend adults maintain melanopic exposure >250 lx during the day, <10 lx in the evening, and <1 lx at night18. Although formal guidelines for children are lacking, evidence suggests they are 5 or more times as sensitive as adults, with significant melatonin suppression and phase delays occurring at melanopic EDI as low as 5 lx1922.

Reducing light exposure before bedtime may promote earlier sleep onset and longer sleep duration. Because children have longer overall sleep needs and an earlier circadian phase than adolescents and adults, they are particularly vulnerable to the effects of evening light exposure. This is likely why interventions advancing sleep times are particularly promising for improving overall sleep health in children, but may also be partly due to early school schedules limiting morning sleep extension23. However, minimizing evening light exposure in young children remains challenging in practice. Despite the growing evidence linking light exposure to pediatric sleep disruption, this issue remains largely absent from clinical guidelines and consumer safety standards.

Manufacturers rarely report melanopic or even photopic intensities on nightlight packaging, leaving caregivers and clinicians without clear guidance. Considering the widespread use of nightlights, it is surprising that their biological potency has not been systematically assessed. Understanding how the melanopic intensities of nightlights compare to physiologically relevant thresholds is critical for developing evidence-based recommendations that support pediatric sleep and circadian health.

Results

Based on spectral irradiance measurements (see Fig. 1 for examples), melanopic EDI values were derived and examined across device categories, along with comparisons to known circadian disruption thresholds. Results are presented for both laboratory measurements, representing source-level, maximal ocular exposure (“worst-case”), and for simulated bedroom measurements (Fig. 2), reflecting more typical nighttime use.

Fig. 1. Spectral power distributions (SPDs) for the same nightlight model in two different color options.

Fig. 1

SPDs for the same model nightlight in red (left) and blue (right) are shown, along with corresponding melanopic and photopic illuminances under typical-use conditions. Though visual brightness (photopic illuminance, lx) is similar, biological potencies (melanopic EDI, lx) are significantly different. The red version of this handheld nightlight is also well below melanopic EDI thresholds, whereas the blue version is not. Further details on these two devices may be found in Tables S1S3, for nightlights 1 and 2.

Fig. 2. Schematic diagram of nightlight positions under bedroom (typical) use conditions.

Fig. 2

The relative distance between the light meter (on the pillow) and the nightlights (positioned throughout the room) during measurement is illustrated. Device categories (distances) include: A handhelds (15 cm), B tabletop lamps (92 cm), C projectors (180 cm, measured at ceiling), and D wall plug-ins (274 cm).

Laboratory (source-level/maximal exposure)

Table S1 provides melanopic EDI values derived from measurements obtained at 2 mm from the light-emitting surface, representing maximal ocular exposure. Across all devices and settings, melanopic EDI values spanned several orders of magnitude, from 0.09 lx to over 100,000 lx, with a median (IQR) of 155.49 (22.22, 516.04) lx. These values reflect source-level measurements, not those at typical viewing distances, but are included to provide full spectral characterization of each nightlight.

A Kruskal–Wallis test confirmed significant differences in melanopic EDI between groups (χ²(3) = 22.81, p < 0.0001). Post-hoc Dunn’s tests showed handhelds (24.38 (1.27, 140.30) lx) had significantly lower melanopic EDI than projectors (458.31 (264.94, 601.80) lx) (p < 0.0001); all other comparisons were not statistically significant (tabletop lamps and wall plug-ins were 116.40 (30.67, 501.63) and 189.65 (6.08, 856.62) lx, respectively) (p ≥ 0.16). Fligner–Killeen tests also indicated differences in variance across categories (χ²(3) = 16.79, p = 0.0008).

In terms of biological relevance, we examined the percent of devices and settings meeting and/or falling below various recommendations (Table 1). Overall, 3/24 devices (13%) met nighttime recommendations (<1 lx melanopic EDI), and 63/79 total settings (80%) failed to meet even the least conservative evening recommendations in adults (<10 lx melanopic EDI) under these maximal, source-level exposures. Only three products remained entirely below 5 lx, the lowest level associated with phase shifting and melatonin suppression in children21,22. These were all red-light devices (2 handhelds, 1 wall plug-in) with sufficient visual brightness (13–78 photopic lx) to allow basic nighttime navigation. For the remaining lights with at least one setting falling below the 5 lx melanopic EDI threshold, those lower levels were primarily met with red-appearing light and/or by being on the dimmest available setting (Table S1). While perhaps rare, it is not impossible that children could put their eyes up to these nightlights if placed within reach, making these source-level data relevant for extreme behavior scenarios.

Table 1.

The proportion of nightlights and settings meeting and failing to meet benchmarks within each device category under both a) laboratory (source-level/maximal exposure) and b) bedroom (typical exposure) conditions

Device type % devices meeting all recommendations (<1 lx melanopic EDI) across all settings % devices failing to meet adult nighttime recommendations (<1 lx melanopic EDI) for at least one setting % settings <5 lx melanopic EDI (known pediatric thresholds) % settings with <5 lx melanopic EDI (pediatric threshold) AND >5 photopic lx (for safe navigation)
a) Laboratory (source-level/maximal)
Handhelds (n = 7 devices/24 settings) 29% 71% 33% 25%
Tabletops (n = 4 devices/14 settings) 0% 100% 21% 7%
Projectors (n = 8 devices/31 settings) 0% 100% 3% 0%
Wall Plug-ins (n = 6 devices/10 settings) 17% 83% 20% 20%
b) Simulated Bedroom (typical use)
Handhelds (n = 7 devices/24 settings) 29% 71% 46% 17%
Tabletops (n = 4 devices/14 settings) 25% 75% 71% 0%
Projectors (n = 8 devices/31 settings) 63% 38% 77% 6%
Wall Plug-ins (n = 6 devices/10 settings) 50% 50% 90% 0%

Bedroom (typical use)

Table S2 presents melanopic EDI values measured in a simulated bedroom environment, reflecting ecologically valid nighttime exposure. In contrast to laboratory results, bedroom measurements showed a much narrower range, from 0 to 907.76 lx, with a median (IQR) of 0.72 (0.07, 6.55) lx. Median (IQR) for each category included: handhelds: 4.33 (0.09, 21.48) lx; tabletop lamps: 1.70 (0.54, 4.31) lx; wall plug-ins: 0.27 (0.03, 0.98) lx; and projectors: 0.22 (0.08, 2.33) lx. Four nightlight settings (from three products) produced 0 lx melanopic EDI on at least one setting, despite being visibly illuminated; however, only two of these products met nighttime melanopic EDI recommendations across all available settings.

Though numerical differences appeared across categories, a Kruskal–Wallis test found no significant differences in the distribution of medians (χ²(3) = 6.12, p = 0.106); however, a Fligner–Killeen test revealed significant differences in variability (χ²(3) = 16.79, p < 0.001). Projectors in particular showed some high outliers, likely explained by setup differences. Plug-in projectors, plugged in across the room and reflected off the ceiling (labeled “P” in Table S2), had lower melanopic EDI (0.08 (0.07, 0.30) lx), whereas tabletop projectors, placed closer to the bed and reflected off the ceiling (labeled “B” in Table S2), showed higher melanopic EDI values (1.78 (0.26, 46.86) lx), likely due to proximity to the eyes and stray light from the source.

The percent of devices and settings meeting and/or falling below various recommendations for each nightlight category in the simulated bedroom environment is reported in Table 1. In total, less than half of devices (10/24, 42%) met all nighttime recommendations (<1 lx melanopic EDI) across settings, and 15/79 total settings (19%) failed to meet even the least conservative evening recommendations in adults (<10 lx melanopic EDI). Only 6/79 settings (8%) support both circadian health and visual stimulation (melanopic EDI < 5 lx and photopic >5 lx), including four settings from three devices in the handheld category and the remaining two coming from the same tabletop projector.

Discussion

This study is the first to systematically quantify the biological potency of commercially available nightlights using melanopic equivalent daylight illuminance (EDI) metrics. Our findings reveal that a substantial proportion of nightlights exceed thresholds known to impact circadian physiology, even under typical-use conditions.

While the maximal exposures recorded in laboratory conditions may represent source-level, worst-case scenarios (e.g., holding a bright nightlight immediately up to the eye), the simulated bedroom measurements suggest that more typical usage still often results in melanopic EDI levels that exceed nighttime recommendations and thresholds18,21,22. At the lowest exposure levels, measurements approach the practical noise floor of the spectroradiometer, and values reported as zero reflect signals below the detection threshold under the measurement conditions rather than a confirmed absence of light emission24. Yet, such low levels represent the minority of nightlight settings, which is particularly concerning given accumulating evidence that children’s circadian systems are more sensitive to light than adults (and even adults may be more sensitive than presumed24); thus, the actual physiological effects of nightlights may be even greater than these data suggest. Importantly, although we did not explicitly evaluate compliance with ICNIRP or toy optical radiation standards, all measured nightlight intensities were far below levels associated with photochemical retinal hazard, indicating minimal risk from blue-light exposure under typical usage conditions.

The variation observed across nightlight types highlights two important considerations for pediatric sleep health. First, spectral composition plays a crucial role: red-hued nightlights consistently showed the lowest theoretical biological potency, which is largely due to reduced ipRGC activation at longer wavelengths1. Second, placement and distance from the child’s eye are critical determinants of actual exposure, due to the inverse square law of light propagation and the effects of room reflectance25. Our bedroom simulations also underscore that wall plug-in nightlights and projectors (when positioned farther from the bed) generally produce safer light levels, although exceptions exist. In contrast, handheld nightlights, despite often having lower maximum intensity, pose a greater risk of sleep and circadian disruption because they are typically used close to the eyes.

Balancing visual needs and circadian health remains a challenge. Children with a fear of the dark are also at risk for poor sleep quality26. Thus, eliminating nightlights from the bedroom altogether may be counterproductive. Instead, the goal should be to provide nightlights that allow children to see but without eliciting non-visual physiological responses to light. Nightlights that provide sufficient photopic illumination for safe navigation typically exceed melanopic thresholds for circadian disruption18. Conversely, those that maintain low melanopic exposure often fail to provide adequate light for practical use. However, our data show that some products can strike this balance, suggesting feasible design improvements.

From a clinical perspective, pediatricians should counsel families on the importance of selecting nightlights with lower melanopic content, particularly red or amber lights at the dimmest settings. Placement recommendations include positioning lights away from direct line-of-sight and increasing the distance from the child’s bed, out of reach, when possible. Additional strategies to reduce reliance on nightlights, such as comfort objects or consistent bedtime routines, may also be beneficial.

The absence of standardized labeling or regulatory guidance on nightlight spectral and intensity characteristics is a notable gap. Manufacturers rarely report melanopic or even photopic illuminance, leaving caregivers without critical information to make informed decisions. Given the widespread use of nightlights4 and the known heightened sensitivity of children’s circadian systems1922, establishing clinical guidelines, regulatory standards, and clear product labeling is essential to supporting healthy pediatric sleep and circadian health.

Our light measurement data raise practical concerns about the health and safety impacts of nightlights. Future research should empirically test the impact of nightlights with varying melanopic EDI levels on melatonin secretion, sleep timing, and behavioral outcomes in children, including real-world use with handheld lights. Long-term studies are also needed to evaluate the chronic effects of low-level nocturnal light exposure in pediatric populations.

Methods

This study involved measuring the spectral irradiance of a range of commercially available children’s nightlights under both laboratory and ecologically valid conditions. Our goal was to calculate melanopic equivalent daylight illuminance (melanopic EDI) and evaluate each nightlight’s theoretical biological potency relative to established circadian thresholds.

Nightlight selection

We selected 25 nightlights marketed for use in children, representing different form factors and spectral profiles to ensure broad generalizability. Specific products were chosen based on popularity and consumer ratings from major online retailers between 2022 and 2024, reflecting typical consumer purchasing behavior rather than a statistically representative sampling of all available products. Nightlights were grouped into four categories that varied according to typical bedroom placement and use: (1) battery-operated or rechargeable handhelds (n = 7); (2) tabletop lamps, light boxes, or bare bulbs (n = 4); (3) Plug-in or tabletop projectors reflecting light off ceilings or walls (n = 8); and (4) flush-mount wall plug-ins (n = 6). Some devices (n = 4) could fit into multiple categories; in such cases, we used the configuration closest to the bed to capture the highest potential ocular exposure.

Light measurements

Each nightlight was measured in both the laboratory and a simulated bedroom environment. Laboratory conditions included source-level measurements that characterized maximal emission (2 mm from the emitting surface). These measurements provide standardized, reproducible data across nightlights, though they do not reflect typical viewing behavior. Simulated bedroom measurements were taken to approximate typical use under more ecologically valid conditions, with devices positioned according to common practices and the meter at the level of the eye in bed, capturing more realistic exposure scenarios.

Spectral power distributions (power at each wavelength in the visible spectrum; examples in Fig. 1) and irradiance (total power per unit area) measurements were obtained using a PR-670 spectroradiometer (Photo Research, North Syracuse, NY; Model 2900-0087-40, Serial No. 67200301). The instrument was factory calibrated by the manufacturer (Novanta Corporation, JADAK) on December 21, 2023, with calibration traceable to National Institute of Standards and Technology (NIST) standards. Calibration included wavelength accuracy and absolute spectral sensitivity, with a stated color accuracy of CIE 1931 x,y ± 0.0015, and the device was within its certified calibration period at the time of all measurements. Three measurements were averaged for each nightlight setting in both laboratory and bedroom environments, all performed in complete darkness (confirmed via undetectable ambient light values). A Konica Minolta T-10A illuminance meter (Konica Minolta Inc., Tokyo, Japan) was used as a secondary device to cross-check relative photopic illuminance values derived from spectroradiometric data, particularly at lower light levels; because illuminance meters may exhibit spectral mismatch for narrowband or colored sources, these values were interpreted qualitatively, while all biologically relevant metrics were derived from calibrated spectroradiometric measurements. At very low irradiance levels approaching the spectroradiometer’s noise floor, measurements were interpreted cautiously; values reported as zero reflect signals below the practical detection threshold under the measurement conditions employed, rather than a confirmed absence of optical output.

For laboratory source-level measurements, the meter was positioned within 2 mm of the light-emitting surface. While this represents a “worst-case” source characterization, it does not reflect typical child behavior. Children, however, may occasionally place a light directly at eye level out of curiosity, and thus, the laboratory measurement remains informative beyond just the advantage of producing standardized, more easily reproducible spectral data across devices.

For the bedroom (335 cm × 366 cm), the sensor approximated eye position in the bed, and nightlights were placed in the bedroom according to typical use (Fig. 2). Handhelds were set up in the bed just below the pillow (15 cm from meter); tabletop lights were positioned on a bedside table (92 cm from meter); and plug-in projectors and flush-mount devices were plugged into an outlet on the wall opposite the bed (274 cm from meter). The meter sensor was placed on a tripod on the bed at the level of the pillow top and directed toward the nightlight, except for tabletop projectors and plug-in projectors, when the meter sensor was instead directed at the ceiling to capture reflected light (180 cm from meter to ceiling).

Color and intensity settings were recorded for each nightlight, and up to six configurations per product were measured to assess the full range of potential physiological impact. For example, several nightlights were measured at red, blue, and white settings at both minimum and maximum intensities (detailed in Table S1).

Analyses

Alpha-opic illuminances, including melanopic EDI, were derived using the Commission Internationale de l’Éclairage S 026/E:2018 toolbox16. Each nightlight setting (n = 79 total) was treated as an independent observation for statistical comparisons. All statistical analyses were performed using R version 4.5.0 (R Core Team, 2025)27. Descriptive statistics provided means, standard errors (SE), median, and interquartile range (IQR), and the proportion of nightlights and settings that met or exceeded thresholds for circadian health (<1 and 5 lx melanopic EDI) were calculated. The distribution of melanopic EDI data was assessed using the Shapiro–Wilk test, which indicated significant deviation from normality (p < 0.0001). Non-parametric methods were therefore employed to assess group differences at the p < .05 level. Specifically, the Kruskal–Wallis test compared median melanopic EDI values across nightlight categories, and Dunn’s test with Bonferroni correction was employed for post-hoc pairwise comparisons. In addition, the Fligner–Killeen test compared variances across nightlight types. We acknowledge that rankings and measurements are context-specific, based on the tested units under defined conditions; product availability, specifications, or light sources may change over time. In addition, statistical analyses were primarily descriptive, aimed at summarizing melanopic EDI distributions and identifying patterns across nightlight types. While formal hypothesis testing was performed to compare medians and variances, we emphasize that the primary purpose of these analyses is not to establish definitive inferential conclusions, but rather to provide a structured and transparent framework for comparing products and protecting against potential bias in reporting.

Supplementary information

Supplementary Information (162.7KB, pdf)

Acknowledgements

We thank Michelle Schneider for assisting with purchases of nightlights, Aaron Steckelberg for assistance with formatting figures, and Lameese Akacem for early discussions about the manuscript. This research was funded by the Department of Energy under contract #DE-EE0008206 and the USU Summer Scholars Program.

Author contributions

G.G., S.B., and E.H. conceptualized the study. S.P., R.E., A.S., K.B., and S.B. collected data. G.G., R.E., and E.H. analyzed data. G.G., K.B., and R.E. prepared the initial draft of the manuscript. R.E., A.E., and G.G. prepared figures and tables. All authors reviewed and edited the manuscript.

Data availability

All data generated or analyzed during this study are included in this published article and its supplementary information files.

Competing interests

G.G. reports that financial support was provided by the US Department of Energy. R.E. and A.S. report financial support was provided by the Uniformed Services University of the Health Sciences. G .G. reports a relationship with Litebook that includes consulting or advisory services. G.G. reports a relationship with Progressive Lighting and Radiometrics that includes: board membership and equity or stocks. G.G. has patent #10213619 B2, #10603507, #7678140 B2 and #8366755 B2 licensed to Litebook. G.G. has collaborated on projects and co-authored papers with colleagues at BIOS Lighting and f.lux. Other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The opinions and assertions expressed herein are those of the author(s) and do not necessarily reflect the official policy or position of the Uniformed Services University of the Health Sciences (USU), The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., or the Department of Defense (DoD). References to non-Federal entities, trade names, commercial products, or organizations do not constitute or imply endorsement by USU, DoD, or the U.S. Government. This research protocol was reviewed and approved by the USU institutional review board in accordance with all applicable Federal regulations governing the protection of humans in research (protocol# USUHS.2019-016). This work was prepared by a military or civilian employee (G.G.) of the U.S. Government as part of the individual’s official duties and therefore is in the public domain and does not possess copyright protection (public domain information may be freely distributed and copied; however, as a courtesy, it is requested that USU and the author be given an appropriate acknowledgment).

Footnotes

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Gena L. Glickman, Email: gena.glickman@usuhs.edu

Elizabeth M. Harrison, Email: elizabeth.harrison.ctr@usuhs.edu

Supplementary information

The online version contains supplementary material available at 10.1038/s44323-026-00072-6.

References

  • 1.Vetter, C. et al. A review of human physiological responses to light: implications for the development of integrative lighting solutions. Leukos18, 387–414 (2022). [Google Scholar]
  • 2.Hill, D. Media use in school-aged children and adolescents. Pediatrics138, e20162592 (2016). [DOI] [PubMed] [Google Scholar]
  • 3.Hale, L. et al. Youth screen media habits and sleep: sleep-friendly screen behavior recommendations for clinicians, educators, a, 2022nd parents. Child Adolesc. Psychiatr. Clin. N. Am.27, 229–245 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Durduran, Y., Pekcan, S. & Çolpan, B. Sleep habits and related factors in kindergarten children. Niger. J. Clin. Pr.22, 1218–1223 (2019). [Google Scholar]
  • 5.Liu, X., Liu, L., Owens, J. A. & Kaplan, D. L. Sleep patterns and sleep problems among schoolchildren in the United States and China. Pediatrics115, 241–249 (2005). [DOI] [PubMed] [Google Scholar]
  • 6.Medic, G., Wille, M. & Hemels, M. E. Short- and long-term health consequences of sleep disruption. Nat. Sci. Sleep9, 151–161 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Hattar, S., Liao, H. W., Takao, M., Berson, D. M. & Yao, K. W. Melanopsin-containing retinal ganglion cells: architecture, projections, and intrinsic photosensitivity. Science295, 165–170 (2002). [Google Scholar]
  • 8.Berson, D. M., Dunn, F. A. & Takao, M. Phototransduction by retinal ganglion cells that set the circadian clock. Science295, 1070–1073 (2002). [DOI] [PubMed] [Google Scholar]
  • 9.Brown, T. M. Melanopic illuminance defines the magnitude of human circadian light responses under a wide range of conditions. J. Pineal Res.69, e12655 (2020). [DOI] [PubMed] [Google Scholar]
  • 10.Czeisler, C. A. et al. Bright light resets the human circadian pacemaker independent of the timing of the sleep-wake cycle. Science233, 667–671 (1986). [DOI] [PubMed] [Google Scholar]
  • 11.Brainard, G. C. et al. Action spectrum for melatonin regulation in humans: evidence for a novel circadian photoreceptor. J. Neurosci.21, 6405–6412 (2001). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Thapan, K., Arendt, J. & Skene, D. J. An action spectrum for melatonin suppression: evidence for a novel non-rod, non-cone photoreceptor system in humans. J. Physiol.535, 261–267 (2001). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Lockley, S. W., Brainard, G. C. & Czeisler, C. A. High sensitivity of the human circadian melatonin rhythm to resetting by short wavelength light. J. Clin. Endocrinol. Metab.88, 4502–4505 (2003). [DOI] [PubMed] [Google Scholar]
  • 14.Bessman, S. C. et al. Hybrid effectiveness-implementation study of two novel spectrally engineered lighting interventions for shiftworkers on a high-security watchfloor. Sleep Adv.4, zpad051 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Lucas, R. J. et al. Measuring and using light in the melanopsin age. Trends Neurosci.37, 1–9 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.International Commission on Illumination (CIE). CIE S 026:2018 CIE System for Metrology of Optical Radiation for ipRGC-Influenced Responses to Light (CIE, Vienna, Austria, 2018).
  • 17.Zeitzer, J. M., Dijk, D. J., Kronauer, R. E., Brown, E. N. & Czeisler, C. A. Sensitivity of the human circadian pacemaker to nocturnal light: melatonin phase resetting and suppression. J. Physiol.526, 695–702 (2000). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Brown, T. M. et al. Recommendations for daytime, evening, and nighttime indoor light exposure to best support physiology, sleep, and wakefulness in healthy adults. PLoS Biol.20, e3001571 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Higuchi, S., Nagafuchi, Y., Lee, S. I. & Harada, T. Influence of light at night on melatonin suppression in children. J. Clin. Endocrinol. Metab.99, 3298–3303 (2014). [DOI] [PubMed] [Google Scholar]
  • 20.Akacem, L. D., Wright, K. P. Jr. & LeBourgeois, M. K. Sensitivity of the circadian system to evening bright light in preschool-age children. Physiol. Rep.6, e13617 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Hartstein, L. E. et al. High sensitivity of melatonin suppression response to evening light in preschool-aged children. J. Pineal Res.72, e12780 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Hartstein, L. E. et al. Evening light intensity and phase delay of the circadian clock in early childhood. J. Biol. Rhythms38, 77–86 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Magee, L. et al. Nonpharmacological interventions to lengthen sleep duration in healthy children: a systematic review and meta-analysis. JAMA Pediatr.176, 1084–1097 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Walbeek, T. J., Harrison, E. M., Gorman, M. R. & Glickman, G. L. Naturalistic intensities of light at night: a review of the potent effects of very dim light on circadian responses and considerations for translational research. Front. Neurol.1, 625334 (2021). [Google Scholar]
  • 25.Fontana, L. Effect of indoor surfaces’ spectral reflectance on the environmental light spectrum modification and on objects perceived color. Results Eng.17, 100805 (2023). [Google Scholar]
  • 26.Kushnir, J. & Sadeh, A. Sleep of preschool children with night-time fears. Sleep Med.12, 870–874 (2011). [DOI] [PubMed] [Google Scholar]
  • 27.R Core Team. R: A Language and Environment for Statistical Computing (R Foundation for Statistical Computing, Vienna, Austria, 2025).

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information (162.7KB, pdf)

Data Availability Statement

All data generated or analyzed during this study are included in this published article and its supplementary information files.


Articles from npj Biological Timing and Sleep are provided here courtesy of Nature Publishing Group