Odds ratios and mean differences with confidence interval for variables associated with urinary L. pneumophila antigen test positivity

Sample and test Odds ratio (confidence interval) for:
Mean difference (confidence interval) for:
CAP category 2 versus 1 CAP category 3 versus 1 Male gender Days before first urine sample No. of urine samples
Nonconcentrated urine
    Biotest EIA 2.5 (0.6-10.9) 12.6 (2.1-74) 2.4 (0.8-7.9) 4.5 (1.3-7.6) 0.7 (0.0-1.6)
    Binax EIA 4.5 (1.0-21.0) 10.5 (2.1-52) 4.2 (1.3-13.6) 3.8 (0.7-6.9) 0.4 (0.0-1.3)
    Binax NOW 6.5 (1.3-33.0) 16.5 (2.8-98) 3.0 (0.9-9.9) 4.9 (1.2-8.5) 0.7 (0.0-1.6)
Concentrated urine
    Biotest EIA 5.0 (1.0-25.0) 12.6 (2.1-74) 2.5 (0.8-8.4) 3.8 (0.4-7.2) 0.6 (0.0-1.5)
    Binax EIA 6.1 (1.0-36.9) 20.1 (2.1-190) 3.4 (0.9-13.0) 4.9 (1.2-8.5) 0.8 (0.0-1.8)
    Binax NOW 6.1 (1.0-36.9) 4.0 (2.2-7.3) 1.8 (0.5-6.6) 6.7 (3.1-10.3) 1.0 (0.3-1.6)