TABLE 4.
Antibody | GM (EU)
|
||
---|---|---|---|
First injection | Second injection | Third injection | |
Anti-GAMP | <0.2 | 33.2 | 39.7 |
Anti-W135P | <0.2 | 2.5 | 8.5 |
Anti-rSEC | <0.2 | 5.5 | 45.7 |
The bivalent conjugate was composed with GAMP-rSEC3 and W135P(H)-rSEC6 to a final concentration of 25 μg/ml of each CP; each mouse was immunized 0.1 ml. IgG responses in the second and third injections had statistic difference with the corresponding first injections (P < 0.01). Also, for 8.5 versus 2.5 and 45.7 versus 5.5, P < 0.05.