Table 2.

Results of alarm function 15 months post-installation

Ionisation, zinc battery
Ionisation, zinc battery, pause button
Ionisation, lithium battery, pause button
Optical, lithium battery
Optical, zinc battery
All homes (n=625)
Smoker occupier (n=295)
Open plan kitchen (n=148)
All homes (n=628)
Smoker occupier (n=295)
Open plan kitchen (n=149)
All homes (n=267)
Smoker occupier (n=127)
Open plan kitchen (n=62)
All homes (n=266)
Smoking occupier (n=125)
Open plan kitchen (n=60)
All homes (n=359)
Smoker occupier (n=170)
Open plan kitchen (n=87)
Any alarm working 363 (58) 148 (50) 78 (53) 311 (50) 128 (43) 71 (48) 184 (69) 75 (59) 40 (65) 160 (60) 61 (49) 29 (48) 148 (41) 53 (31) 35 (40)
Study alarm working 350 (56) 147 (50) 77 (52) 293 (47) 124 (42) 68 (46) 175 (66) 73 (57) 39 (63) 148 (56) 61 (49) 29 (48) 131 (36) 51 (30) 35 (40)
Study alarm absent 113 (18) 58 (20) 29 (20) 80 (13) 38 (13) 18 (12) 49 (18) 28 (22) 9 (15) 56 (21) 32 (26) 18 (30) 67 (19) 35 (21) 16 (18)
Battery missing* 97 (16) 57 (19) 22 (15) 180 (29) 98 (33) 46 (31) 4 (1) 2 (2) 1 (2) 33 (12) 16 (13) 7 (12) 103 (29) 53 (31) 24 (28)
Battery disconnected* 24 (4) 11 (4) 6 (4) 26 (4) 12 (4) 5 (3) 14 (5) 8 (6) 5 (8) 6 (2) 2 (2) 2 (3) 9 (3) 5 (3) 1 (1)
Battery dead* 4 (<1) 2 (<1) 0 9 (1) 4 (1) 1 (<1) 1 (<1) 1 (<1) 1 (2) 6 (2) 4 (3) 0 21 (6) 11 (6) 6 (7)
*

Not mutually exclusive.