Abstract
Modern radiology relies entirely on digital imaging systems. Healthcare records draw cybercriminals’ attention. On-site and cloud-based informatics systems, including artificial intelligence, can boost efficiency but also create weak points. Medical imaging systems must safeguard patient identities, control access, secure devices, and coordinate with patients, payers, and billing partners. Endorsed by the American College of Radiology and the Society for Imaging Informatics in Medicine, this white paper outlines steps to fortify the medical imaging pipeline methodically, train caregivers on the frontline, and develop incident response and recovery strategies for data breaches and disabling ransomware attacks. Additionally, building a culture of safety in imaging involves conducting routine simulations and actively engaging leadership. Taken together, these multidisciplinary interventions can minimize the clinical impact and operational implications of cybersecurity events, thereby maintaining patient trust in an increasingly interconnected imaging workflow.
Keywords: Radiology cybersecurity, Imaging vulnerabilities, Incident response, Technical safeguards, Simulation
Introduction
Modern radiology practice is fully digital, relying on the continuous and seamless operation of digital imaging assets, databases, and communication systems. At the same time, healthcare data is highly valuable to cybercriminals, making these records prime targets for breaches. In 2024, the Office of Civil Rights reported 725 data breaches and ransomware attacks [1]. In 2024, the most significant breach to date affected an estimated 190 million individuals and crippled business operations for many practices [2].
The portability and interoperability of digital data and the use of on-site and off-site networked computers have invited a host of vulnerabilities. Practices must protect authorized user identities, manage user behavior, access control, and networked devices, as well as on- and off-campus compute resources, and external partners such as patients, payers, and billing companies. These interconnected systems, often requiring updates and maintenance, necessitate robust cybersecurity measures. In his 2022 white paper, “Cybersecurity is Patient Safety,” US Senator Warner and his team discuss important imperatives for practice, including minimum cyber hygiene practices, cyber emergency preparedness, and cyber insurance [3].
In this white paper, we discuss strategies to mitigate risk and restore normal operations in the event of an attack. This collaborative white paper is endorsed by the American College of Radiology (ACR) and the Society for Imaging Informatics in Medicine (SIIM) and is intended to replace the existing 2019 ACR–AAPM–SIIM Practice Parameter for Electronic Medical Information Privacy and Security.
Composition of the White Paper Working Group
A joint white paper working group was convened by the ACR and SIIM, consisting of nine multidisciplinary members charged with developing consensus recommendations:
Po-Hao Chen: Chair of the SIIM Security Subcommittee and a member of the ACR Commission on Informatics. Also serving as Vice Chair of the Enterprise Diagnostics Institute and Former Chief Informatics Officer for Imaging at the Cleveland Clinic, Dr. Chen frequently publishes and presents at national conferences on informatics policy, operational resilience, and ransomware recovery readiness.
Benoit Desjardins: Chief Medical Information Officer and cardiovascular radiologist at Centre Hospitalier de l’Université de Montréal. A recognized authority in AI and medical imaging cybersecurity, Dr. Desjardins holds multiple security certifications and regularly presents on cybersecurity topics at national and international forums. He serves on the SIIM Security Subcommittee and the Healthcare Information and Management Systems Society (HIMSS) Cybersecurity, Privacy and Security Committee.
Brett Strassner: Medical physicist at Radiation Protection Services and member of the SIIM Security Subcommittee. A certified imaging-informatics professional, Mr. Strassner brings expertise in device-level security and technical informatics solutions.
Reza Forghani: Chief of Imaging Informatics at AdventHealth Medical Group, Central Florida Division and a member of the ACR Commission on Informatics. Dr. Forghani has led the design and deployment of enterprise-wide health informatics, AI solutions, and secure imaging platforms across large health systems.
Robert Bodak: Imaging informatics analyst with extensive experience as a radiology technologist. Mr. Bodak advises on imaging data and device implementation and coordinates radiology downtime planning at Cleveland Clinic. He is also an active member of the SIIM Security Subcommittee.
Judy W. Gichoya: Associate Professor in Emory University’s Department of Radiology & Imaging Sciences, Dr. Gichoya is a SIIM Board of Directors member and a member of the ACR Commission on Informatics. She directs Emory’s Healthcare AI Innovation and Translational Informatics (HITI) Lab, focusing on secure machine learning pipelines and health equity.
James Whitfill: Senior Vice President and Chief Transformation Officer at HonorHealth and Adjunct Faculty at Arizona State University. Dr. Whitfill authored the “Data Security and Privacy” chapter in Practical Imaging Informatics, co-authored the 2019 ACR–AAPM–SIIM practice parameter, and served as SIIM Board Chair from 2018 to 2020 [4]. He has lectured in national settings on cybersecurity in healthcare and testified to the Center for Medicare Services (CMS) on cybersecurity of medical devices.
Eric C. Ehman: Chair of the Mayo Clinic Enterprise Radiology Downtime Committee and Lead for AI & Informatics in the Abdominal Imaging Division. Dr. Ehman has led resilience planning for Radiology systems outages and secure AI deployments across Mayo sites.
Christoph Wald: Chair of the ACR Commission on Informatics and Vice-Chair of the ACR Board of Chancellors. Dr. Wald founded ACR’s Cybersecurity Resource Hub by securing partnerships with device manufacturers and US agencies, and has championed comprehensive cyber-resilience planning nationally, bringing both policy insight and practical risk-management expertise.
Each member was selected for their contribution to radiology informatics, cybersecurity, incident resilience planning, and/or organizational leadership. Table 1 presents a summary of affiliations and leadership roles.
Table 1.
Key affiliations and informatics/cybersecurity leadership of working group members
| Member | Credentials | Primary affiliation | Leadership | Area of expertise |
|---|---|---|---|---|
| Po-Hao Chen | MD, MBA | Cleveland Clinic; Case Western Reserve Univ | Chair of SIIM Security Subcommittee; member of ACR Commission on Informatics | Clinical and imaging informatics operations; business resilience; policy |
| Benoit Desjardins | MD, PhD, FAHA, FACR, FNASCI, CEH, CISSP, CIIP | Centre Hospitalier de l’Université de Montréal | Chief Medical Information Officer; Member of SIIM Security Subcommittee; Member of HIMSS Cybersecurity Privacy and Security Committee | Healthcare cybersecurity; artificial intelligence; clinical workflow |
| Brett Strassner | MA, CIIP, CCT, CEH, COSINTP | Radiation Protection Services, Ltd | Member of SIIM Security Subcommittee | Medical physics; device security |
| Reza Forghani | MD, PhD | AdventHealth Medical Group, FL | Chief of Imaging Informatics | Artificial intelligence; implementation; clinical workflow; policy |
| Robert Bodak | RT | Cleveland Clinic | SIIM Security Subcommittee member | Imaging workflow; contingency planning |
| Judy W. Gichoya | MD, MS, FSIIM | Emory University | SIIM Board Member; ACR Commission on Informatics member | Radiology operations; artificial intelligence |
| James Whitfill | MD, MBA, FSIIM | HonorHealth; Arizona State Univ | SVP & Chief Transformation Officer; prior SIIM Chair of the Board of Directors | Digital health strategy; risk management |
| Eric C. Ehman | MD | Mayo Clinic | Chair of Mayo Clinic Enterprise Radiology Downtime Committee | Resilience planning; AI deployment security |
| Christoph Wald | MD, PhD, MBA | Mayo Clinic | Chair, ACR Commission on Informatics; Vice-Chair, ACR Board of Chancellors; Prior chair of radiology | Radiology leadership; policy |
MD, Doctor of Medicine; MBA, Master of Business Administration; FAHA, Fellow of the American Heart Association; FACR, Fellow of the American College of Radiology; FNASCI, Fellow of the North American Society for Cardiovascular Imaging; CISSP, = Certified Information Systems Security Professional; MA, Master of Arts; CIIP, Certified Imaging Informatics Professional; CCT, Certified Cyber Technician; CEH, Certified Ethical Hacker; COSINTP, Certified Open Source Intelligence Professional; RT, radiologic technologist; MS, Master of Science; FSIIM, Fellow of the Society for Imaging Informatics in Medicine; SVP, Senior Vice President; ACR, American College of Radiology; SIIM, Society for Imaging Informatics in Medicine; HIMSS, Healthcare Information and Management Systems Society
How This Article Is Organized
We organize the white paper in two axes. First, a landscape overview outlines vulnerabilities of the modern radiology practice. This description encompasses hardware, software, and data within the context of modern growth in remote work, artificial intelligence, and image sharing, addressing a decentralized but interconnected radiology practice, patient base, and technology infrastructure. The second axis is a toolkit, consisting of safeguards rooted in best practices, regulatory requirements, and technical advancements.
Effective cybersecurity requires an organization-wide approach, with each element deserving action from business leaders, radiologists, technologists, and informatics professionals alike. The article includes two actionable checklists. The “Cybersecurity Checklist for the Radiology Leadership” (Table 2) emphasizes operational readiness through the lens of a clinical and operational leader, whereas the “Checklist for Identifying Vulnerable Imaging Technology” (Table 3) contains more technical granularities through the lens of imaging informatics. Some technical jargon was unavoidable in the checklists, but where relevant, it is explained in this text.
Table 2.
Cybersecurity checklist for the radiology leadership
| Category | Checklist Items |
|---|---|
| System and Device Security |
• Is there a complete inventory of vulnerable radiology systems (see Checklist for Creating an Inventory of Vulnerable Radiology Systems) • Are all software and hardware devices in the imaging chain regularly updated with the latest security patches? • Are all systems and devices securely configured to minimize vulnerabilities? • Is reliable antivirus and anti-malware software installed and maintained on all endpoints and servers? |
| Data Protection and Privacy |
• Is strong encryption used for data at rest and in transit? • Are strict access control measures in place, such that only authorized personnel can access sensitive systems and data? •Is the amount of personal and sensitive data collected and stored minimized to only what is necessary for clinical purposes? |
| Network Security |
• Are firewalls and Intrusion Detection Systems (IDS) deployed to monitor and control incoming and outgoing network traffic? • Is network segmentation implemented to separate critical devices and servers from the rest of the network? |
| User Authentication and Management |
• Are strong password policies enforced, and is multi-factor authentication (MFA) considered for accessing critical systems? • Are staff regularly trained on cybersecurity best practices and phishing awareness? • Are comprehensive logs and audit trails maintained for all system and user activities to promptly detect and respond to suspicious behavior? |
| Vendor and Third-Party Management |
• Do all vendors comply with strict cybersecurity standards as outlined in Service Level Agreements (SLAs)? • Are regular security assessments conducted for third-party vendors who have access to your systems or data? |
| Incident Response and Business Continuity |
• Is there a developed and maintained incident response plan that includes procedures for responding to cybersecurity incidents? • Are regular drills conducted to test the effectiveness of the incident response plan? • Are robust data backup and disaster recovery procedures implemented to ensure data can be restored quickly after a cyber incident? • Is there a clear process for linking downtime reports to corresponding images on temporary storage in a way amenable to post-recovery reconciliation? |
| Compliance and Legal Requirements |
• Is the practice compliant with relevant regulations such as HIPAA or GDPR, which govern the security and privacy of medical information? • Are privacy policies reviewed and updated regularly to align with current laws and best practices? |
| Physical Security |
• Is physical access to facilities housing critical infrastructure and sensitive data controlled? • Are environmental controls in place to protect equipment from unauthorized visitors and natural threats such as earthquake, water damage, or excessive heat? |
| Continuous Improvement |
• Do we have regularly scheduled security audits and penetration testing to identify and rectify vulnerabilities? • Is there a feedback mechanism to learn from security incidents and continuously improve security measures? |
Table 3.
Checklist for identifying vulnerable imaging technology
| Category | Checklist Items |
|---|---|
| Inventory of Software and Hardware Devices |
• Have all imaging modalities (e.g., MRI, CT, X-ray, Ultrasound) been listed, including their make, model, and firmware version? • If a proxy or gateway firewall is used for an imaging modality, have all such firewalls been listed, including make, model, and firmware version? • Are the operating systems and software versions used on each imaging device documented? • Are workstations for downtime use – or the flashing media for creating them – properly secured, dated, and maintained? • Have all imaging workstations managed by the radiology department or practice been listed? (e.g. technologist, radiologist, subspecialist stations such as in orthopedic surgery and cardiology) • Is there an up-to-date list of all servers associated with these devices? |
| Network Infrastructure |
• Is there a complete map of the network infrastructure connecting imaging devices, including routers, switches, and firewalls? • For wireless-enabled modalities such as portable x-ray, are all wireless access points and their security protocols (e.g., WPA2, WPA3) included in the inventory? • Is network segmentation part of the cybersecurity strategy? E.g. are radiology devices and/or workstations on a separate network? • Is there documentation on the network segmentation strategy that isolates critical devices and servers? |
| Data Storage and Management Systems |
• Are all systems used for imaging data management, such as PACS, RIS, VNA, and reporting, inventoried with details on their on-premise or cloud-based location and security measures, along with their make, model, and version? • Is there an inventory of all backup systems and their configurations? • Are data encryption measures at rest and in transit documented for each system? • Is there a process to regularly extract data from offline modalities’ temporary storage during prolonged downtime to accommodate automatic purging? • What storage resources, such as portable media or temporary external drives, have been procured for image storage during prolonged downtime? |
| Software Applications |
• Is there a list of all software applications used in the radiology workflow, including AI and image analysis tools? • Are the software versions and patch statuses documented? • Are any third-party or custom-developed applications identified and reviewed for compliance with security policies? |
| Access Control Systems |
• Are all systems that require user authentication, including imaging equipment, storage systems, and software applications, listed with details on the type of authentication used? • Is there an inventory of all users with access to these systems, categorized by level of access? • Are the protocols for managing user access rights, such as additions, deletions, and modifications, well-documented? |
| Vendor-Specific Information |
• Is there detailed information on all vendors for hardware, software, and IT services used within the radiology department? • Are contact details and support agreements available for each vendor? • Is there a process for regularly reviewing and updating vendor security practices and compliance with industry standards? |
| Security Measures and Protocols |
• Are all installed security measures included in the inventory, such as antivirus software, firewalls, and intrusion detection systems? • Is there a documented protocol for updating security measures and responding to vulnerabilities? • Are training records for cybersecurity awareness among radiology staff maintained and regularly updated? |
| Compliance and Audit |
• Is there documentation that verifies compliance with relevant regulations such as HIPAA, GDPR, or others applicable to the location and operation? • Are the results from the most recent security audits and assessments available? • Is there a schedule for future compliance checks and security audits? |
| Regular Update Cycle | • Has a refresh of the Vulnerable Imaging Technology inventory been regularly scheduled? |
Vulnerabilities in Radiology Operations
Radiology imaging equipment has an operational expectancy that varies from 7 years for an ultrasound unit to 10 years for general radiography equipment [5]. The age of the equipment often poses a risk due to a lack of security features and operating system updates [6]. All available equipment and devices that are connected to a radiology department or practice’s medical imaging ecosystem, including the virtual endpoints (e.g., servers and routers) and physical access (e.g., USB ports), comprise the department’s attack surface. Attack surfaces may be managed with a cybersecurity hygiene routine that is tailored to the imaging environment [7]. Supplementing this section is Table 3, “Checklist for Identifying Vulnerable Imaging Technology,” which offers an actionable tool for enumerating vulnerable technology and mitigating cybersecurity processes for operational continuity.
Hardware Infrastructure
Many radiology practices and hospitals continue to own physical storage and computing hardware. However, hospital policies and assigned technical responsibilities can shape radiology security practices, sometimes limiting the ability to adopt ideal cyber-hygiene measures. Additionally, the radiology information and picture archiving and communication systems (PACS) remain commonly deployed on-premises. Servers could reside within or immediately adjacent to the hospital and be directly connected (i.e., “hardwired”) to the intranet, or they may reside in a data center and be connected through a site-to-site virtual private network (VPN). Even when on-premises, modern radiology servers often establish Internet connections to external cloud-based platforms or remote support services, introducing dependencies and vulnerabilities and driving considerations of performance, cost, latency, and regulatory compliance beyond physical location.
Securing imaging hardware, including modalities and workstations, has become increasingly challenging as imaging practices become more integrated into the broader world. Cybersecurity hygiene practices such as regularly updating software, using complex passwords, implementing multi-factor authentication (MFA), placing equipment behind firewalls, and conducting regular security audits will assist in reducing risk [7].
Modality equipment also may have intrinsic, dedicated storage that offers temporary storage for images. Because such storage is temporary and limited, modalities are usually configured with image lifecycle policies to purge older data automatically. During extended downtime, this temporary storage may become disconnected from central storage, making its image lifecycle policies a risk for permanent data loss.
Data, Software, and Virtual Infrastructure
In addition to hardware-related considerations, imaging operations also depend on a growing list of informatics tools. There is a growing adoption of PACS and vendor-neutral archives (VNA) for enterprise-wide imaging needs as well as increased use of advanced imaging and artificial intelligence (AI) tools. These tools can be hosted entirely on-premises using organization-owned hardware, on dynamically provisioned infrastructure outside the enterprise network (e.g., cloud-based), or in a hybrid configuration. This reliance means unauthorized access and data breaches are growing concerns, with misconfigured PACS servers having exposed millions of patient studies [8–10]. Ransomware attacks can encrypt imaging data, disrupt clinical workflows, delay patient care, and even lead to permanent patient data loss [11, 12].
While cloud providers reduce the effort needed to manage physical security and infrastructure, they do not obviate important cybersecurity protection measures. In particular, securing applications and data remains the responsibility of the application vendor and local hospital or radiology practice. The cybersecurity vulnerabilities of cloud-based solutions may also be opaque to the radiology practice due to third-party management. Therefore, protection involves new administrative needs, new technical demands for data encryption during transmission and in remote storage, and verifying vendor compliance with healthcare regulations, including data residency and sovereignty requirements [13].
AI infrastructure adds a layer of complexity. At a basic level, integrating AI tools creates new points of exposure. Additionally, AI models can suffer from adversarial attacks—where malicious inputs deceive AI models—and be misled to generate false inferences [11, 12, 14]. AI models might not exhibit obvious signs of cognitive compromise and could quietly insert incorrect outputs into systems of record and require efforts to enhance or develop performance drift and monitoring mechanisms [11]. There is an increasing use of third-party AI orchestration platforms, which offer several advantages, including improved efficiency, scalability, and quality. However, like the use of cloud in standard imaging operations, these also pose the risk of a single point of failure.
To meet the growing demands of patients seeking care across different health systems or geographical locations, as well as the needs of research and AI development, recent years have seen a substantial increase in demand for image sharing. The ACR strongly advocates for the elimination of physical media [15]. However, the adoption of digital image sharing comes with its own security considerations for electronic protected health information (ePHI) management.
To protect the multitude of physical, virtual, and software assets, as well as data, in daily radiology operations and for image sharing, various safeguards—including physical, technical, and administrative controls—may be implemented. Some of them apply across multiple settings, some are mandated by law, and some are best practices. The next section outlines a representative set of these safeguards, along with their operational, technical, and regulatory implications.
Safeguards in Operational Security in Radiology
Some portions of the “2019 Practice Parameter” outline procedures for safeguarding ePHI continue to be relevant [16]. At the core of these procedures is an emphasis on the importance of administrative, physical, and technical safeguards by the Health Insurance Portability and Accountability Act (HIPAA) Security Rule [17], under the broader Title 45 Part 164 Subpart C of the US Code and Federal Regulations [18–20]. This section offers a high-level overview of relevant safeguards but is not intended to be a comprehensive regulatory guide. Tables 1 and 2 combine many of these concepts in the context of specific vulnerabilities into a checklist.
Physical Safeguards
These physical barriers protect data and systems from unauthorized access or damage.
Access Control: To control access to sensitive areas in radiology, multiple layers of nested security are used, such as securing the hospital, the radiology department, the imaging rooms, and the devices (e.g., servers and workstations). It can involve locked doors, biometric scans, keycards, and device-specific security measures like disabling USB ports on workstations. Security systems, such as alarms and surveillance cameras, help detect and monitor activity in real time. Protocols for the secure disposal of outdated devices, media, and records ensure that no sensitive information is left exposed.
Environmental Protection: Radiology equipment is highly sensitive to environmental changes. Electronic devices require specific fire protection systems, such as gas systems, as well as temperature and humidity control, to safeguard equipment and data. Backup power sources, such as uninterruptible power supplies (UPS) and generators, ensure critical systems remain operational during power outages.
Physical safeguards also include a facility-level physical security plan and contingency operations in the case of lost data [19].
Technical Safeguards
These are the security measures implemented by technology systems. A “defense in depth” strategy is the best practice, involving the use of multiple technical safeguards simultaneously.
De-identification: Personally identifiable information (PII) may be present in reports, images, and associated image metadata. Not all healthcare data exchange must involve data de-identification. In some situations, such as disclosure to the patient, for operational use, billing, or as required by law, PII is permitted. In other situations, individuals may expressly authorize the disclosure of PII. If de-identification is required, the requirements for de-identification are defined by HIPAA and the Health Information Technology for Economic and Clinical Health Act (HITECH) through CFR§164.514 and generally fall into two methodologies: (a) expert determination, where a qualified person applies statistical and scientific principles to determine that the risk of reidentification is very small, or (b) safe harbor method, where all 18 pre-defined elements of identifiers are removed from all shared data [21].
Access Control: Secure technical access to all maintained systems must be subject to access control policies and procedures. Passwords, multi-factor authentication, proper authorization, regular accounting, and role-based access control (RBAC) ensure that only authorized personnel can access the right sensitive information in a trackable fashion. RBAC also ensures that users can only view the data necessary for their tasks. A proper combination of authentication, authorization, and accounting is also known as the AAA model of access control. Access control safeguards also apply to remote access and cloud-based applications.
Monitoring and Auditing: To comply with HIPAA/HITECH and other applicable federal regulations (e.g., 21 CFR § 11.10(e) and 45 CFR § 164.312(b)), healthcare organizations must maintain secure, computer-generated, time-stamped audit trails for all activities in systems that store or process ePHI [20, 22]. These detailed, granular logs should be periodically reviewed, by 45 CFR § 164.308(a)(1)(ii)(c), to detect any irregular patterns, suspicious activity, or potential breaches and retained for a period that meets or exceeds the statutory requirements for maintaining the associated medical records. Audit and monitoring for compliance with HIPAA also apply to third-party contractors and vendor-managed solutions used in clinical operations.
Data Encryption and Backup: Data confidentiality, integrity, and availability are critical in radiology and are commonly referred to as the CIA triad, as advocated by the National Institute of Standards and Technology (NIST) [23]. Encryption of personally identifiable data at rest (e.g., encrypted drives) and in transit (e.g., TLS/SSL transmission protocols) is an addressable concern under the HIPAA Security Rule [17]. Some state laws supplement HIPAA with more stringent requirements; for instance, Massachusetts 201 CMR 17.00 mandates, “encryption of all transmitted records and files containing personal information” and “encryption of all personal information stored on laptops or other portable devices” [24]. Integrity controls, including the use of hashes and digital signatures, along with secure data-sharing protocols, ensure that data remains unaltered. Cloud-based, off-site, or air-gapped backups also contribute to rapid recovery from data loss or ransomware attacks.
Network Security: Broadly, network security consists of perimeter security and segmentation. Although not mandated, a “reasonable and appropriate technical safeguard” by the HIPAA Security Rule implies the need for a strong perimeter security to protect the transmission of medical images when transferring over a network. Examples include software and hardware firewalls that regulate incoming as well as outgoing traffic and intrusion detection and prevention systems that inspect and can act on network data [17, 25]. Virtual private networks are software or hardware solutions that use data encryption to allow an external device to appear and be used as though it is inside the firewall of a private network [17]. Network segmentation involves physically and/or logically separating different parts of a healthcare system’s IT infrastructure to limit the damage from security compromises and can be achieved using either hardware or software-defined approaches. Network segmentation is commonly cited as a principal method that keeps an unfortunate network breach from becoming a catastrophic one [12, 26, 27]. Under the current HIPAA Security Rule, both perimeter security and segmentation are “addressable” implementation specifications: covered entities must assess whether they are “reasonable and appropriate” to their environment and, if so, deploy them or document why an alternative safeguard suffices [17].
Endpoint Protection: “Endpoints” refer to devices that can serve as entry points into a network. Although not strictly mandated by law, the voluntary guidelines from Health Industry Cybersecurity Practices (HICP) and recent recommendations from the Food and Drug Administration (FDA) establish the use of anti-malware software and device management policies on connected devices as best practice [28, 29]. Connected endpoints in medical imaging range from imaging modalities to PACS servers, workstations, and mobile phones that can access data. Additional best practices include device hardening technical policies, such as adopting the latest vendor security configurations, disabling unused ports, and whitelisting allowed applications. Regular updates and security patches help mitigate vulnerabilities.
Administrative Safeguards
These are the rules, policies, and procedures to manage security practices per CFR 45 § 164.308 [18].
Risk Assessment: § 164.308 mandates regular risk assessments and periodic evaluations to identify vulnerabilities in systems, networks, and data storage methods [18]. These assessments help develop strategies to mitigate risks and prepare for potential security breaches. To address breach notification mandates, best practices for risk assessment should also include establishing protocols for breach notification and penetration testing [17, 30, 31].
Policies and Procedures: Administrative leadership is responsible and accountable for building clear policies regarding access control, data encryption, and device management for systems they maintain (18,20). Policies for access control should handle privilege requests and approvals for local staff and third parties, regular audits of access rights, and role change management. Well-defined procedures for monitoring systems, managing incidents, and controlling changes help protect patient data. Specific protocols governing the access, retention, and disposal of radiology records help maintain compliance and must be integrated with the broader hospital policies.
Workforce Management: Cybersecurity awareness and training for all workforce members is mandatory by the HIPAA Security Rule at a reasonable and appropriate interval [17]. The HITECH Act adds civil-monetary penalty maximums for all HIPAA violations, introduces breach-notification requirements, and adds additional penalties for failures to provide (and document) effective cybersecurity training [30]. A training program must cover security incident recognition and reporting, password management, workstation security, and protection against social engineering attacks. Most successful ransomware attacks have relied on social engineering, such as phishing, to access systems, and clinical practices should assume a breach attempt is already in progress, if not already successful. Proper termination procedures must be followed when employees leave or change roles.
Vendor Management: Administrative policies and procedures of a facility should also apply to third-party contractors and vendor-managed solutions, such as proactively enabling security features as default configurations. This also includes a cybersecurity bill of materials for any “cyber devices,” including software as a medical device (SaMD) purchases under the Food, Drug & Cosmetics Act Sect. 524B [32]. An agreement, usually a business associate agreement (BAA), can give radiology practices the right to be notified about security breaches that affect a vendor platform and/or the data contained therein. A master service agreement (MSA) or the BAA can also offer provisions for audit rights to vendor software access logs for compliance and security monitoring.
Incident Response and Recovery: An effective incident response plan defines roles and responsibilities during a security breach and includes reporting mechanisms, escalation, procedures for recovery, and post-incident analysis. Regular drills ensure the team is prepared for potential incidents, and disaster recovery plans improve the odds of business continuity in the event of a breach or system failure [33].
Compliance and Governance: Radiology practices must comply with federal as well as relevant state laws and regulations to ensure their security practices meet legal standards. Regular security audits and a dedicated security officer ensure all policies are followed and updated.
Managing Risk During and After a Disabling Ransomware Attack.
A major challenge in planning for extended, catastrophic downtime is the misplaced confidence employees and departments may have after managing shorter or less extensive downtimes, such as during software or network upgrades.
Reacting to a ransomware attack is different.
While many non-technical staff might consider the unavailability of the electronic medical records system (EMR) as the primary concern during a ransomware attack, the actual impact is much broader. For example, Internet Protocol (IP) telephony, file sharing and document access, intranet web portals, and PACS/VNA infrastructure are examples of technologies not available during a ransomware event. Since some ransomware events can last 4 to 6 weeks or more, staff must also prepare for risks that accumulate over prolonged downtimes, such as payroll management, ordering supplies, modalities running out of local storage for exams, and tracking of manually created diagnostic reports [34].
Management strategies to mitigate these risks include educating the technical and non-technical staff team on the unique aspects of a prolonged total network outage, allocating resources to mitigate and recover from such attacks, creating redundancy and forms of technical separation to mitigate the extent of the attack, and preparing a disaster recovery plan. Conducting tabletop exercises with senior leaders to simulate the types of decisions that will need to be made as time elapses can provide valuable education on why traditional downtime strategies are unlikely to be effective in the event of a catastrophic ransomware incident [35]. Simulation and downtime drills are explored in more depth in the section “Implementing a Culture of Security.”
Health systems addressing a cyber event will likely require three different teams to coordinate their activities:
A Cyber Response team that liaises with law enforcement and insurance firms. The team is also responsible for making decisions regarding internal and external notifications. Once the extent of damage is known, breach notification to Health and Human Services (HHS) or affected individuals may be relevant [30, 31]. The US Federal Bureau of Investigation strongly discourages direct negotiation with, or payment to, ransomware actors [36].
An Incident Command (IC) team that employs standard IC methodology to communicate and evaluate the response to an emergency. Table 4 outlines the members of the IC team and their respective roles.
Technology response teams are responsible for the technical tasks of assessing the extent of the attack, evaluating the viability of backups, and developing restoration plans for different scenarios, such as bare metal restore versus file restoration.
Table 4.
Roles and responsibilities of the incident command team responding to a cyber attack
| Role | Responsibilities |
|---|---|
| Incident commander | Oversees the entire response effort, makes strategic decisions, coordinates communication between teams and external stakeholders |
| Technical lead | Directs the technical response, identifies and contains the threat, assesses damage, restores systems, collaborates with IT staff and external consultants |
| Communications officer | Manages internal and external communications, ensures stakeholders are informed, uses alternative communication channels if needed |
| Legal advisor | Provides guidance on legal matters, regulatory compliance, reporting obligations, interactions with law enforcement |
| Public relations specialist | Handles media inquiries, public statements, manages the organization's reputation, maintains public trust |
| Business continuity planner | Develops and implements plans to ensure critical business functions continue during and after the incident |
| Human resources representative | Addresses staffing needs, employee communication, provides support to affected staff members |
Additional team structures and expanded descriptions of responsibilities may be found in the NIST Special Publication 800–61 [37].
Communication plans must consider the possibility that standard communication channels might be inoperable in an emergency, in part mandated by the Center for Medicare & Medicaid Services (CMS) Condition of Participation (§ 482.15) [38]. For leadership communications, a system outside the usual email and IP telephony channels is best practice, potentially utilizing cellular capabilities. Within hospitals, two-way radios may be the most reliable form of distributed communication during a network-wide outage. Public and social media can serve as a method of communicating with employees and patients. While liability concerns sometimes discourage extensive communication, maintaining stakeholders’ trust requires open and frequent communication.
To prepare for a systemwide outage, as often observed in ransomware incidents, clinical systems should be categorized to determine both the priority for restoration and the need for comprehensive and tested downtime procedures [34]. As systems are gradually restored, workflows may become unpredictable due to partial network and system recovery, which could last for several days or even weeks. Additionally, when resuming operations using manual or improvised interpretation processes, be aware of human errors. Executing plans for post-recovery reconciliation of reports and their associated images, management of provider communication of critical findings, and tracking follow-up of incidental findings can be complex and laborious. A process co-developed with risk management may be necessary to address critical findings discovered after incident recovery—potentially months later—to assess and mitigate patient impact from delayed diagnosis. It is also important to understand the effect of manual workflow on billing, as delays can limit collections for professional and facility charges, and missed collections may cause surprise billing to patients once the episode of care is complete. Once all systems are recovered, a debrief of the event should be made to understand the cause of failure and any management strategies needed to mitigate future occurrences, including resource allocation.
Continuous Improvement Through a Culture of Security
Effective prevention and recovery in the setting of a cyberattack relies not only on robust downtime processes, but also on the team of people who implement those procedures [39]. Developing policies and procedures for responding to cyber or ransomware attacks requires a substantial investment of both time and resources. These efforts should be viewed as an investment against an inevitable disruption, rather than as contingency plans against an unlikely event.
The first step in building a response plan to a ransomware-type attack is to form a committee to head the effort [39]. Relevant stakeholders from across the radiology practice and hospital, including information technology staff, physicians, technologists, and administrative personnel, should all be represented [34]. The Technical Resources, Assistance Center, and Information Exchange (TRACIE), created by the Administration for Strategic Preparedness and Response (ASPR) of HHS, offers a Cyber Response Checklist and Cyber Incident System Restoration Checklist, which can serve as a starting point for radiology departments or private practices looking to develop unit-specific response plans [40, 41]. However, empowering the group to create customized downtime procedures that take into account unique aspects of the organization will result in more relevant and resilient plans [33].
With processes and procedures, the next step in establishing an ongoing culture of safety is to routinely perform simulations and drills for both expected and unexpected downtime challenges, such as through mock outages, tabletop exercises, or computer simulations [35, 42]. The training frequency varies depending on the organization’s specific needs and size and on the nature of the training.
Downtime drill content should vary from session to session. Simulations might include a response to specific system(s) being down or all systems being down simultaneously. By drilling for both types of threats, deep dives into protocols and procedures for the outage of a specific system can be balanced with strategies to approach a more extreme event involving all systems. A debriefing opportunity is strongly recommended, both by the larger group to gather feedback and by the smaller downtime leadership committee to act on that feedback to effect meaningful changes in protocols. Figure 1 outlines one possible workflow for downtime drills.
Fig. 1.
Note: this data is mandatory
Establishing a culture of safety is a challenging yet important part of building resilience. With a dedicated group of downtime champions, the larger department can more effectively simulate and practice different downtime contingencies, refining procedures and protocols through frequent exercises.
Conclusion
The American College of Radiology (ACR) and the Society for Imaging Informatics in Medicine (SIIM) are committed to safeguarding medical imaging. The daily operations of radiology and enterprise imaging departments increasingly rely on technology that has become ever more interconnected within and across a health network. Protecting hospital operations means methodically fortifying the medical imaging pipeline, training the caregivers on the frontline, and developing incident response and recovery strategies. Ultimately, a security culture necessitates consistent training, simulations, and active leadership involvement. Taken together, these multidisciplinary interventions can minimize the data risk, privacy concerns, and financial implications of data breaches and disabling attacks and help maintain patient trust.
During the preparation of this work, the authors used Microsoft Copilot and Grammarly in order to copyedit the manuscript. After using this tool/service, the authors reviewed and edited the content as needed and take full responsibility for the content of the publication.
Author Contribution
- Substantial contributions to the conception or design of the work: all co-authors.
- Acquisition, analysis, or interpretation of data for the work: not applicable
- Drafting the work or revising it critically for important intellectual content: all co-authors
- Final approval of the version to be published: all co-authors
- Agreement to be accountable for all aspects of the work: all co-authors
Data Availability
Not applicable. No data was analyzed.
Declarations
Ethics Approval
Not human or animal subject research.
Consent to Participate
Not human or animal subject research.
Consent for Publication
Not human or animal subject research.
Conflict of Interest
Po-Hao Chen received grant funding from Siemens Healthineers AG, the National Institutes of Health, and the Arthritis Foundation.
Reza Forghani received grant funding from Nuance Communications Inc., Canon Medical Systems Corporation (also non-financial support and speaking/lecture fees), General Electric Company, the NIH, and the National Science Foundation; provided consulting/advisory services to PaxeraHealth Corp. and Neuropacs Corp.; and holds U.S. Patent No. 11,257,210 B2 issued to the Royal Institution for the Advancement of Learning.
Judy Gichoya received speaking/lecture fees from the National Bureau of Economic Research, Cook Medical LLC, and APPOS CME and grant funding from Lunit Inc., the Clarity Consortium, and the Bunkerhill Foundation.
Christoph Wald serves as Chair, Commission on Informatics, and Vice Chair, Board of Chancellors, American College of Radiology and provides consulting/advisory services to Deepc (with equity) and Radpair.
All other authors declare no known competing financial interests or personal relationships that could have influenced this work.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Office of Civil Rights D of H and HR. OCR Portal of Health Information Breaches Affecting 500 or More Individuals [Internet]. 2025 [cited 2025 Feb 22]. Available from: https://ocrportal.hhs.gov/ocr/breach/breach_report.jsf
- 2.Alder S. Change Healthcare Responding to Cyberattack [Internet]. The HIPAA Journal; 2024 [cited 2025 Feb 22]. Available from: https://www.hipaajournal.com/change-healthcare-responding-to-cyberattack/
- 3.Warner MR. Cybersecurity is Patient Safety [Internet]. Office of Senator Mark R. Warner; 2022 [cited 2025 Feb 22]. Available from: https://www.warner.senate.gov/public/_cache/files/f/5/f5020e27-d20f-49d1-b8f0-bac298f5da0b/0320658680B8F1D29C9A94895044DA31.cips-report.pdf
- 4.Whitfill J. Data Security and Patient Privacy. In: Branstetter BFI, editor. Practical Imaging Informatics: Foundations and Applications for Medical Imaging. 2nd ed. New York, NY: Springer; 2021. p. 119–30. [Google Scholar]
- 5.European Society of Radiology (ESR). (2014) Renewal of radiological equipment. Insights Imaging. 5(5):543–6. [DOI] [PMC free article] [PubMed]
- 6.Das Gupta S, Shah D. (2024) Safeguarding the future of radiology with imaging informatics. AuntMinnie.com. Mar 28
- 7.Grimes SL, Wirth A. The Case for Medical Device Cybersecurity Hygiene Practices for Frontline Personnel. Biomed Instrum Technol. 2021 Jul;55(3):96–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.HIPAA Journal Staff. (2021) Radiology Specialists Facing Class-Action Lawsuit Over PACS Data Breach [Internet].HIPAA Journal. Available from: https://www.hipaajournal.com/radiology-specialists-facing-class-action-lawsuit-over-pacs-data-breach/
- 9.Davis J. (2021) Millions of medical images, patient data remain exposed via PACS flaws [Internet]. SC Media; Available from: https://www.scworld.com/news/millions-of-medical-images-patient-data-remain-exposed-via-pacs-flaws
- 10.Cawthra J, Kuruvilla J, Littlefield K, Niemeyer B, Wang S, Williams R, et al. (2020) Securing Picture Archiving and Communication System (PACS): Cybersecurity for the Healthcare Sector [Internet]. National Institute of Standards and Technology (NIST). Available from: https://www.nccoe.nist.gov/publication/1800-24/VolA/
- 11.Shah C, Nachand D, Wald C, Chen PH. Keeping Patient Data Secure in the Age of Radiology Artificial Intelligence: Cybersecurity Considerations and Future Directions. J Am Coll Radiol. 2023 Sep;20(9):828–35. [DOI] [PubMed] [Google Scholar]
- 12.Kelly BS, Quinn C, Belton N, Lawlor A, Killeen RP, Burrell J. Cybersecurity considerations for radiology departments involved with artificial intelligence. Eur Radiol. 2023 Jul 7;33(12):8833–41. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Zandesh Z. Privacy, Security, and Legal Issues in the Health Cloud: Structured Review for Taxonomy Development. JMIR Form Res. 2024 Feb 12;8:e38372. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Mirsky Y, Mahler T, Shelef I, Elovici Y. (2023) CT-GAN: Malicious Tampering of 3D Medical Imagery using Deep Learning [Internet]. arXiv; 2019 [cited Feb 8]. Available from: http://arxiv.org/abs/1901.03597
- 15.McGinty G. #DitchtheDisk. J Digit Imaging. 2022 Aug;35(4):737–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.American College of Radiology.(2019) ACR–AAPM–SIIM Practice Parameter for Electronic Medical Information Privacy and Security [Internet]. Jan. Available from: https://www.acr.org/-/media/ACR/Files/Practice-Parameters/Elec-Info-Privacy.pdf
- 17.United States Health and Human Services. The HIPAA Security Rule [Internet]. Available from: https://www.hhs.gov/hipaa/for-professionals/security/index.html
- 18.U.S. Code of Federal Regulations, Title 45, § 164.308: Administrative safeguards [Internet]. Available from: https://www.ecfr.gov/current/title-45/subtitle-A/subchapter-C/part-164/subpart-C/section-164.308
- 19.U.S. Code of Federal Regulations, Title 45, § 164.310: Physical Safeguards [Internet]. Available from: https://www.ecfr.gov/current/title-45/subtitle-A/subchapter-C/part-164/subpart-C/section-164.310
- 20.U.S. Code of Federal Regulations, Title 45, § 164.312: Technical Safeguards [Internet]. Available from: https://www.ecfr.gov/current/title-45/subtitle-A/subchapter-C/part-164/subpart-C/section-164.312
- 21.United States Health and Human Services. The HIPAA Privacy Rule [Internet]. Available from: https://www.hhs.gov/hipaa/for-professionals/privacy/index.html
- 22.U.S. Code of Federal Regulations, Title 21, § 11.10: Controls for closed systems [Internet]. Available from: https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-B/section-11.10
- 23.National Institute of Standards and Technology. NIST SPECIAL PUBLICATION 1800–26 [Internet]. [cited 2025 Apr 11]. Available from: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.1800-26.pdf
- 24.Office of Consumer Affairs and Business Regulation. 201 CMR 17.00: Standards for the Protection of Personal Information of Residents of the Commonwealth [Internet]. Nov, 2009. Available from: https://www.mass.gov/doc/201-cmr-17-standards-for-the-protection-of-personal-information-of-residents-of-the-commonwealth/download
- 25.Hady AA, Ghubaish A, Salman T, Unal D, Jain R. Intrusion Detection System for Healthcare Systems Using Medical and Network Data: A Comparison Study. IEEE Access. 2020;8:106576–84. [Google Scholar]
- 26.Nguyen XV, Petscavage-Thomas JM, Straus CM, Ikuta I. Cybersecurity in radiology: Cautionary Tales, Proactive Prevention, and What to do When You Get Hacked. Curr Probl Diagn Radiol. 2024 [DOI] [PubMed]
- 27.Eichelberg M, Kleber K, Kämmerer M. Cybersecurity in PACS and medical imaging: an overview. J Digit Imaging. 2020;33(6):1527–42. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.U.S. Food and Drug Administration. Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions, Guidance for Industry and Food and Drug Administration Staff [Internet]. 2023. Available from: https://www.fda.gov/media/119933/download
- 29.U.S. Department of Health and Human Services. Health Industry Cybersecurity Practices: Managing Threats and Protecting Patients (HICP) [Internet]. U.S. Department of Health and Human Services; 2023. Available from: https://405d.hhs.gov/Documents/HICP-Main-508.pdf
- 30.Health Information Technology for Economic and Clinical Health (HITECH) Act [Internet]. 2009. Available from: https://www.govinfo.gov/content/pkg/PLAW-111publ5/pdf/PLAW-111publ5.pdf
- 31.Office for Civil Rights, U.S. Department of Health and Human Services. Breach Notification Rule [Internet]. 2013. Available from: https://www.hhs.gov/hipaa/for-professionals/breach-notification/index.html
- 32.Federal Food, Drug, and Cosmetic Act, § 524B [Internet]. Available from: https://www.federalregister.gov/documents/2023/09/27/2023-20955/cybersecurity-in-medical-devices-quality-system-considerations-and-content-of-premarket-submissions
- 33.Larsen E, Hoffman D, Rivera C, Kleiner BM, Wernz C, Ratwani RM. Continuing Patient Care during Electronic Health Record Downtime. Appl Clin Inform. 2019 May;10(3):495–504. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Chen PH, Bodak R, Gandhi NS. Ransomware Recovery and Imaging Operations: Lessons Learned and Planning Considerations. J Digit Imaging. 2021 Jun;34(3):731–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Maggio LA, Dameff C, Kanter SL, Woods B, Tully J. (2020) Cybersecurity Challenges and the Academic Health Center: An Interactive Tabletop Simulation for Executives. Acad Med J Assoc Am Med Coll. 24 [DOI] [PubMed]
- 36.Federal Bureau of Investigation. (2016) Ransomware Prevention and Response for CISOs [Internet].Federal Bureau of Investigation. Available from: https://www.fbi.gov/file-repository/ransomware-prevention-and-response-for-cisos.pdf
- 37.Cichonski P, Millar T, Grance T, Scarfone K. (2012) Computer Security Incident Handling Guide : Recommendations of the National Institute of Standards and Technology [Internet]. National Institute of Standards and Technology; 2012 Aug [cited 2025 Apr 16] p. NIST SP 800–61r2. Report No. NIST SP 800–61r2. Available from: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-61r2.pdf
- 38.Centers for Medicare & Medicaid Services, U.S. (2025) Department of Health and Human Services. 42 CFR § 482.15: Condition of Participation: Emergency Preparedness [Internet]. Available from: https://www.ecfr.gov/current/title-42/chapter-IV/subchapter-G/part-482/subpart-B/section-482.15
- 39.Jalali MS, Kaiser JP. Cybersecurity in Hospitals: A Systematic, Organizational Perspective. J Med Internet Res. 2018 May 28;20(5):e10059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.ASPR TRACIE. Cyber Incident Response Checklist [Internet]. 2021. Available from: https://files.asprtracie.hhs.gov/documents/healthcare-system-cybersecurity-incident-response-checklist.pdf
- 41.ASPR TRACIE. (2020) Cyber Incident System Restoration Checklist [Internet]. Available from: https://files.asprtracie.hhs.gov/documents/healthcare-system-cybersecurity-incident-system-restoration-checklist.pdf
- 42.Ghayoomi H, Laskey K, Miller-Hooks E, Hooks C, Tariverdi M. Assessing resilience of hospitals to cyberattack. Digit Health. 2021;7:20552076211059366. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable. No data was analyzed.