Abstract
Objective
Surgical arrhythmia ablation is challenging as a result of arrhythmia induction and mapping limitations in the operating room. We hypothesized that a novel preoperative workflow involving artificial intelligence (AI) electrocardiographic (ECG) and computed tomography (CT) analysis to localize arrhythmia sources and identifying myocardial scar would facilitate surgical arrhythmia ablation.
Methods
We conducted a feasibility study at 2 institutions under institutional review board–approved protocols. ECG recordings of target arrhythmias were analyzed to localize ventricular tachycardia (VT) and premature ventricular complex (PVC) sources. Concurrently, cardiac CT studies underwent AI analysis to identify myocardial scar. The results were combined into a 3-dimensional model for surgical ablation planning. The primary end point was the composite of death from any cause, VT storm, sustained VT, appropriate implantable cardioverter-defibrillator shock, and (for patients who underwent PVC ablation) PVC burden reduction less than 50% at 1-year follow-up.
Results
Of the 13 patients enrolled (9 PVC ablation and 4 VT ablation procedures), concomitant surgeries included mitral valve repair (4 patients, 31%), left ventricular assist device implantation (n, 3, 23%), and bypass surgery (n, 2, 15%). At a median of 1-year follow-up, 11 of 13 (84.6%) patients were free from the primary end point. PVC burden decreased from an average of 22.1 ± 15.9% to 2.6 ± 2.30% (P = .008). In patients with VT, implantable cardioverter-defibrillator shocks decreased from 9.2 ± 5.2 per month to 0 ± 0 per month (P = .012). Complications were not increased compared with a weighted average from prior published studies.
Conclusions
AI-based cardiac CT analysis and ECG arrhythmia mapping are feasible and facilitate surgical arrhythmia ablation, yielding significant reductions in arrhythmia burden compared with baseline. Additional studies are required to validate these findings in larger populations.
Key Words: ventricular tachycardia, PVCs, cardiothoracic surgery, catheter ablation, surgical ablation, ECG, electroanatomic mapping

Integrating an AI-based CT scar model with forward-solution ECG mapping to guide surgical ablation.
Central Message.
A novel noninvasive AI-based arrhythmia mapping workflow can safely and effectively enable and guide surgical ventricular arrhythmia ablation.
Perspective.
Ventricular arrhythmias are challenging to map in the surgical OR. Current methods require induction of the arrhythmia and mapping, which is time-consuming and pose increased risk of clinical decompensation. Our novel method of noninvasive mapping can be easily integrated into the surgical workflow and can expand catheter ablation therapy to a wider range of patients.
Ventricular arrhythmias (VAs), including ventricular tachycardia (VT) and premature ventricular contractions (PVCs), are associated with significant morbidity and mortality1,2 and can be challenging to treat, particularly in patients requiring cardiothoracic surgical management. In addition, some patients with VA have end-stage heart failure, active coronary or valvular heart disease, or other conditions that limit the ability to perform catheter ablation in the electrophysiology laboratory.3
For these patients, surgical ablation either in addition to the indicated surgical procedure or as the primary intervention is an option at specialized centers,4 but significant limitations to the intraoperative mapping process are often present. In the surgical operating room, it is frequently difficult to localize the origination sites and sustaining substrate of VAs.5 Furthermore, even if electroanatomic mapping equipment is available, it may be suboptimal because of impedance and anatomic changes during surgical access and manipulation of the heart during surgery, limited and nonstandard electrocardiographic (ECG) and patch electrode positions because of sternotomy, and inability to induce arrhythmia during cardioplegic cardiac arrest during aortic crossclamping.
Previous work has described an artificial intelligence (AI) mapping algorithm that has been shown to localize VA origins using 12-lead ECG data.6 The ECG mapping algorithm has been validated to accurately localize VT and PVC origination sites6, 7, 8 in nonsurgical ablation procedures. However, the utility of this technology to assist in surgical arrhythmia ablation is uncertain.
Separately, a deep learning cardiac computed tomography (CT) wall-thinning analysis algorithm has been developed9 to visualize the extent and distribution of wall thinning as a surrogate of scar10 and fibrosis. However, the utility of this technology and the ability to fuse patient-specific anatomy and noninvasive arrhythmia mapping onto a combined 3-dimensional model has not been demonstrated. We hypothesized that the prospective use of AI-enabled ECG and CT analysis could facilitate surgical planning and guide targeted surgical VA ablation in patients undergoing indicated cardiac surgery or primary surgical arrhythmia ablation.
Methods
Patient Enrollment
Consecutive patients undergoing cardiac surgery with clinically significant VT or PVCs or undergoing primary surgical arrhythmia ablation were prospectively enrolled at 2 centers. The institutional review board approved the study protocol and publication of data (protocol no. 171964; approval date: November 2017; renewed October 15, 2025, University of California San Diego). Patients provided informed written consent for the publication of the study data.
Inclusion criteria included either (1) recurrent VT requiring defibrillation or implantable cardioverter-defibrillator (ICD) therapies or (2) symptomatic or high-burden PVCs (>10%) in patients undergoing any of the following: cardiac surgery for coronary artery bypass grafting for severe coronary artery disease; valvular repair or replacement for severe valvular heart disease; left ventricular assist device (LVAD) for end-stage heart failure; coronary artery unroofing for congenital anomalous coronary arteries; pulmonary thromboendarterectomy; thoracic aortic repair; or primary surgical VA ablation in patients with no viable option for catheter ablation.
Exclusion criteria included the absence of a 12-lead ECG recording of the arrhythmia, poor ECG data quality precluding AI analysis, absence of high-resolution cardiac imaging, poor imaging quality precluding AI analysis, dextrocardia, and complex adult congenital heart disease, defined by the absence of the interventricular septum.
Study End Points
The primary end point was a composite of death from any cause, VT storm, appropriate ICD shock, sustained VT treated by medical intervention, and (for patients who underwent PVC ablation) PVC burden reduction less than 50%.
AI 12-Lead ECG Mapping Protocol
The AI ECG mapping algorithm for VA is based on a forward-solution arrhythmia simulation library consisting of more than half a million VA simulations generated in computational heart models with and without simulated scar, dilatation, and hypertrophy as described in previous work.6 The algorithm provides single-beat VT and PVC mapping. The probability distribution of VA origin is then displayed on a 3-dimensional model for consideration by the physician.
12-Lead ECG VA Recording
Standard American Heart Association 12-lead ECG configurations were used in all patients. For PVCs and VT, a 12-lead ECG capturing at least 1 beat of each clinical PVC(s) or 6 seconds of VF was obtained in the outpatient clinic, emergency department, inpatient room, or intensive care unit.
Noninvasive Programmed Stimulation Protocol
If no spontaneous VT was captured, then the patient underwent a preoperative, noninvasive programmed stimulation study using an ICD with anesthesiology support for sedation if required. VT was induced according to a previously described protocol.11,12 Once clinical VT was induced and recorded, overdrive pacing or cardioversion was performed to terminate VT. Digitized ECG data were then downloaded to a USB memory device and uploaded to the AI ECG mapping software for analysis, as discussed previously.
Deep Learning Cardiac CT Wall-Thinning Algorithm
High-resolution cardiac CT data were then processed using a deep learning tool that extracted cardiac anatomical information from the DICOM image data.9 The left ventricular anatomical information then underwent further analysis to identify regions with wall thinning as a surrogate for myocardial scar. This analysis was communicated as a color-coded surface mesh projected on a patient-specific anatomical model.
Concomitant Surgical Ablation Workflow
The AI ECG and CT analyses were then shared with the attending cardiothoracic surgeon, who then developed a surgical plan for each patient. Surgical ablation was performed at the identified region per standard protocol using either a radiofrequency ablation (Aquamantys, Medtronic) or a cryoablation catheter (Freezor, Medtronic). End points of ablation included suppression of cardiac ectopy and completion of ablation delivery to targeted regions according to the preplanned ablation strategy as determined by the attending surgeon.
Figure 1 demonstrates a sample workflow incorporating the noninvasive 12-lead ECG mapping of electrical VA foci as well as the AI-based CT wall-thinning algorithm localizing scar substrate in a 73-year-old patient with VT undergoing concomitant LVAD implantation.
Figure 1.
Integrating an artificial intelligence (AI)–based computed tomography (CT) scar model with forward-solution electrocardiographic (ECG) arrhythmia mapping to guide concomitant surgical ablation. A, Forward solution 12-lead ECG mapping localizes the electrical substrate to the midapical inferoseptum of the left ventricle (LV). B, AI CT wall-thinning scar model localizes a channel of scar substrate of interest. C, Using both of these noninvasive mapping tools, surgical ablation was guided to the midapical inferosetpal LV during left ventricular assist device (LVAD) implantation. The darker patches on heart indicate regions of scar. D, Histology sample of LV core removed during LVAD implantation confirmed presence of dense fibrosis consistent with old, organized scar tissue.
Clinical Follow-up
All patients were followed for at least 1 year by remote monitoring of an implantable device (an implantable loop recorder was implanted if no ICD was present). VT detection or therapy zones were unchanged from preablation or set 20 beats per minute below the slowest VT cycle length. Antiarrhythmic medications were discontinued according to clinical context and operator discretion.
Assessment of Complications and Comparison With the Published Literature
All complications were recorded and classified them into major and minor complications according to current Society of Thoracic Surgeons (STS) criteria. We then determined the expected rate of major complications on the basis of a literature review for each procedure type in the study. We then calculated a weighted average on the basis of the number of patients for each surgery type to estimate an overall study-expected complication rate on the basis of surgical procedure types to allow comparison of the observed versus expected complication rates.
Statistical Analysis
For continuous variables, non-normal distributed samples were compared with the Mann-Whitney U test or paired samples using the Wilcoxon signed rank test. Nominal or categorical variables were compared with the Fisher exact test.
For the clinical outcome analysis, Cox regression survival analysis was used to analyze the clinical end points of this cohort. Variance was expressed as interquartile range and CI as 0.95. Statistical calculations were performed using SPSS, version 29 (IBM Corp) and R statistical software, version 4.4.1 (R Foundation for Statistical Computing).
Results
Patient Characteristics
We enrolled 13 patients undergoing surgical VT (4 patients, 30.8%) and PVC ablation (9 patients, 69.2%), with characteristics summarized in Table 1. Patients were aged 62.9 ± 15.0 years, 85% were male, 61.5% had ischemic cardiomyopathy, with an average left ventricular ejection fraction of 45.0 ± 20.3%. Most patients had 1 or more atherosclerotic cardiovascular diseases or risk factors including hypertension (53.8%), history of myocardial infarction (46.2%), and history of heart failure hospitalization (46.2%). All 4 patients who underwent VT ablation had an ICD implantation before ablation. None of the patients in the PVC ablation cohort had a previous ICD implantation. No patients were lost to follow-up.
Table 1.
Study patients
| Patient characteristics | PVC ablation (n = 9) | VT ablation (n = 4) | P value |
|---|---|---|---|
| Age, y ± SD | 61.2 ± 16.4 | 66.8 ± 13.1 | .82 |
| Sex, % (n) | |||
| Male | 77.8% (n = 7) | 100% (n = 4) | 1.00 |
| Female | 22.2% (n = 2) | 0% (n = 0) | 1.00 |
| LVEF, % ± SD | 52.2% ± 17.5% | 30% ± 19.6% | .09 |
| Ischemic CMP, % (n) | 33.3% (n = 3) | 75% (n = 3) | .27 |
| Nonischemic CMP, % (n) | 22.2% (n = 2) | 50% (n = 2) | .53 |
| Medical history, % (n) | |||
| Myocardial infarction | 33.3% (n = 3) | 75% (n = 3) | .27 |
| Stroke | |||
| Diabetes mellitus | 22.2% (n = 2) | 25% (n = 1) | 1.00 |
| Hypertension | 66.7% (n = 6) | 25% (n = 1) | .27 |
| Hyperlipidemia | 55.6% (n = 5) | 75% (n = 3) | 1.00 |
| Heart failure hospitalization | 22.2% (n = 2) | 100% (n = 4) | .02 |
| Atrial fibrillation | 12.5% (n = 1) | 100% (n = 4) | .001 |
| Previous ICD implantation | 0% (n = 9) | 100% (n = 4) | .001 |
| Medications, % (n) | |||
| Aspirin | 55.6% (n = 5) | 75% (n = 3) | 1.00 |
| P2Y12 inhibitor | 0% (n = 0) | 25% (n = 1) | .31 |
| Beta-blocker | 33.3% (n = 3) | 100% (n = 4) | .07 |
| ACE/ARB/ARNI | 22.2% (n = 2) | 75% (n = 3) | .09 |
| MRA | 11.1% (n = 1) | 0% (n = 0) | 1.00 |
| Statin | 55.6% (n = 5) | 75% (n = 3) | 1.00 |
| Antiarrhythmic meds, % (n) | |||
| Class I AAD | 22.2% (n = 2) | 50% (n = 2) | .53 |
| Class III AAD except amiodarone | 0% (n = 0) | 25% (n = 1) | 1.00 |
| Amiodarone | 33% (n = 3) | 75% (n = 3) | .27 |
PVC, Premature ventricular complex; VT, ventricular tachycardia; SD, standard deviation; LVEF, left ventricular ejection fraction; CMP, cardiomyopathy; ICD, implantable cardioverter-defibrillator; ACE, angiotensin receptor blocker; ARB, angiotensin receptor blocker; ARNI, angiotensin receptor and neprilysin inhibitor; MRA, mineralocorticoid receptor antagonist; AAD, antiarrhythmic drug.
Surgery and Ablation Characteristics
The study protocol was used in a variety of surgical cases (Table 2); the greatest proportion of these included mitral valve repair (31%, n = 4), durable left-ventricular assist device implantation (23%, n = 3), or coronary artery bypass graft surgery (15.4%, n = 2). In addition, the study protocol was used in anomalous coronary artery repair (n = 1), thoracic aorta repair (n = 1), pulmonary thromboendarterectomy (n = 1), as well as a primary surgical epicardial ablation (n = 1). Concomitant left atrial appendage exclusion was performed in 4 patients (30.1%), because few patients had history of atrial fibrillation at time of surgery.
Table 2.
Surgical metrics
| Characteristics | PVC ablation (n = 9) | VT ablation (n = 4) | P value |
|---|---|---|---|
| Surgical procedure | |||
| Mitral valve repair | 3 | 1 | 1.00 |
| LVAD implantation | 1 | 2 | .20 |
| CABG surgery | 2 | 0 | 1.00 |
| Anomalous coronary artery repair | 1 | 0 | 1.00 |
| Aortic repair | 1 | 0 | 1.00 |
| Pulmonary thromboendarterectomy | 1 | 0 | 1.00 |
| Primary surgical ablation | 0 | 1 | .31 |
| Left atrial appendage exclusion | 3 | 1 | 1.00 |
| STS risk | |||
| Operative mortality, %, median | 1.9% | 13.3% | |
| Operative mortality, %, mean ± SD | 3.46 ± 4.8% | 15.3% ± 13.8% | .24 |
| 90-d morbidity and mortality, %, median | 9.9% | 52.8% | |
| 90-d morbidity and mortality, %, mean ± SD | 15.0% ± 16% | 48.5% ± 16% | .15 |
| Surgical metric | |||
| Case duration, min, min, mean ± SD | 367 ± 116 | 374 ± 204 | .83 |
| Cardiopulmonary bypass time, min, mean ± SD | 167 ± 60 | 192.5 ± 144 | .70 |
PVC, Premature ventricular complex; VT, ventricular tachycardia; LVAD, left ventricular assist device; CABG, coronary artery bypass graft; STS, Society of Thoracic Surgeons; SD, standard deviation.
In our cohort, only 1 patient had VA within 24 hours of the surgical ablation. The remainder of patients were in normal sinus rhythm at the time of surgery. Shown in Table 2, the median and mean STS risk of death in patients who received PVC ablation were 1.9% and 3.46%, respectively. The VT ablation group was at greater risk, with median and mean risk of death 13.3% and 15.3%, respectively. Total surgical case duration was 369 ± 139 minutes. Patients were on cardiopulmonary bypass for 175 ± 88 minutes. Noninvasive mapping was done preoperatively and did not impact cardiopulmonary bypass time.
Arrhythmia Source Locations
Mapped arrhythmia source locations included the endocardial surface of the left ventricle inclusive of the papillary muscles (n = 6, 46.2%); the epicardial left ventricular summit (n = 5, 38.5%); the left ventricular outflow tract (n = 1, 7.7%); the right ventricular outflow tract (n = 1, 7.7%); and the anteroseptal right ventricle (n = 1, 7.7%). Ablation characteristics are shown in Table 3.
Table 3.
Arrhythmia and ablation characteristics
| Ablation type | |
|---|---|
| Endocardial | 53.8% (n = 7) |
| Epicardial | 38.5% (n = 5) |
| Combined | 7.7% (n = 1) |
| VT ablation percentage | 30.1% (n = 4) |
| PVC ablation percentage | 69.9% (n = 9) |
| VT average cycle length, ms | 423 ± 127 |
| PVC/VT origins | |
| Outflow tract | 15.4% (n = 2) |
| LV chamber | 46.2% (n = 6) |
| RV chamber | 7.7% (n = 1) |
| Epicardial | 38.5% (n = 5) |
| Energy source | |
| Cryoablation | 76.9% (n = 10) |
| Radiofrequency | 23.1% (n = 3) |
VT, Ventricular tachycardia; PVC, premature ventricular complex; LV, left ventricular; RV, right ventricular.
Endocardial Versus Epicardial Ablation
In the cohort, 53.8% (n = 7) of cases were for endocardial ablation, 38.5% (n= 5) were for epicardial ablation, and 7.7% (n = 1) a combined epicardial/endocardial ablation.
Ablation Energy
In total, 76.9% (n = 11) of the cases used cryoablation as the energy source of ablation, and 23.1% (n = 3) of cases used radiofrequency ablation.
Clinical Outcomes
At minimum 1-year follow-up (median follow-up 24 months), 84.6% of patients were free from the primary study end point (see Figure 2). For patients who underwent PVC ablation, the mean PVC burden was reduced from average 20.6% to 2.8% (P = .009). Figure 3 demonstrates the PVC burden for each patient in the cohort before and after the surgical ablation. Every patient in the PVC ablation cohort had reduction of 50% or greater PVC burden at 1 year. In addition, patient ejection fraction in postoperative follow-up remained stable in both the VT ablation and PVC ablation cohorts (see Table E1).
Figure 2.
Primary end-point Kaplan-Meier curve during 3-month and 1-year follow-up. Kaplan-Meier curve of the surgical ablation cohort when looking at the combined primary end point of death, ventricular tachycardia (VT) storm, recurrence of ventricular arrhythmias, or a postablation premature ventricular complex (PVC) burden of >50% compared with previous baseline. In total, 84.6% of patients were free of the primary outcome at 1-year follow-up (95% CI)
Figure 3.
Comparison of premature ventricular complex (PVC) burden before and 1 year after ablation. In total, when using artificial intelligence–based electrocardiographic and computed tomography scar mapping, 100% of the patients had reduction of PVC burden 1 year postablation. Average PVC burden decreased from 20.6% to 2.8% (P = .009). Each individual patient had PVC burden reduction of 50% or greater at 1 year follow-up.
Antiarrhythmic pharmacotherapy was discontinued in 10 patients (76.9%), with 3 patients restarted on antiarrhythmic therapy. One patient was continued on sotalol because of a high risk of VT recurrence and rare symptomatic PVCs in a patient with Lamin A/C cardiomyopathy. Two patients were restarted on low-dose amiodarone 200 mg once a day after developing postoperative atrial fibrillation. In addition, 5 patients required ongoing long-term anticoagulation for greater than 1 year after their ablations for various indications (1 for chronic thromboembolic pulmonary hypertension, 3 for durable LVAD, 1 for atrial fibrillation and stroke prevention). One of the patients who had an LVAD eventually patient had anticoagulation discontinued 30 months after ablation due to receiving a heart transplant.
Complications
There were 2 major (15.4%) postoperative complications in our study, by STS guidelines.13 This included 1 patient who was admitted for VT storm and cardiogenic shock who required emergent surgery despite elevated STS risk >10% and 48% risk of 30-day morbidity and mortality. The patient developed severe coagulopathy intraoperatively during weaning of cardiopulmonary bypass and required multiple blood transfusions for hemorrhagic shock. The patient was then noted to have worsening cardiogenic shock requiring insertion of an intra-aortic balloon pump. Although postoperatively the patient eventually was able to be weaned off inotropes and mechanical circulatory support, the patient subsequently developed a series of hospital-acquired infections leading to refractory shock, renal failure, and severe metabolic encephalopathy. The patient eventually transitioned to comfort care and died.
There were 6 minor (46.2%) complications, including 4 patients (30.8%) with bleeding requiring transfusion and 2 patients (15.4%) with postoperative atrial fibrillation lasting less than 48 hours in duration and no recurrence during follow-up. The bleeding complications were involved considered either a complex surgery (ie, redo sternotomy) or greater risk with STS risk >10% for 90 day morbidity and mortality. There were no complications in the primary surgical arrhythmia ablation case. Table 4 summarizes surgical complications.
Table 4.
Study complications
| Type | PVC ablation (n = 9) | VT ablation (n = 4) | P value |
|---|---|---|---|
| Major | |||
| Death (within 30 d) | 0% (n = 0) | 25% (n = 1) | 1.00 |
| Stroke | 11.1% (n = 1) | 0% (n = 0) | 1.00 |
| Cardiogenic shock requiring hemodynamic support | 0% (n = 0) | 25% (n = 1) | 1.00 |
| Minor | |||
| Bleeding requiring transfusion | 22.2% (n = 2) | 50% (n = 2) | .53 |
| Postoperative AF | 22.2% (n = 2) | 0% (n = 0) | 1.00 |
PVC, Premature ventricular complex; VT, ventricular tachycardia; AF, atrial fibrillation.
Comparison of Complications With the Published Literature
We calculated that the expected rate for major complications in this study was 20.8% (Table E2). Our observed rate of major complications (15.4%) was lower than this rate; the small sample size precludes statistical comparison.
Discussion
There are 3 key takeaways from this research study. First, combining AI ECG mapping and CT wall-thinning analysis is feasible and facilitates surgical arrhythmia ablation, most commonly as an adjunctive procedure during clinically indicated cardiothoracic surgery. Second, knowledge of the arrhythmia-sustaining source location, patient-specific anatomy, and the distribution of myocardial scar led to high arrhythmia ablation success rate. Third, concomitant surgical arrhythmia ablation did not increase complications compared with the expected rate on the basis of the primary surgical procedures.
Challenges of Surgical Arrhythmia Ablation
Early VA ablation procedures in the 1970s were surgical and consisted of endocardial resection to remove proarrhythmic scar.14 Since then, technological advances have introduced cryoablation15 and radiofrequency ablation16 to the operative management of cardiac arrhythmias. Even so, there were challenges in arrhythmia induction and maintenance during cardioplegia and barriers to arrhythmia mapping to localize the origins and arrhythmia-sustaining substrate for VT and PVCs.5
With the advent of catheter technologies17,18 and the advantages of a minimally invasive approach, it has led to catheter ablation as the primary treatment option for VT ablation.4 However, there remains a substantial proportion of patients in whom surgical arrhythmia is either the preferred or only therapeutic option for refractory VAs. This feasibility study was designed to explore emerging AI technologies that may assist this approach, increasing patient access to surgical arrhythmia ablation.
AI ECG and CT Analysis Facilitate Surgical Arrhythmia Ablation Planning and Execution
AI ECG and CT analysis allows patient-specific arrhythmia source localization7 and detailed anatomical assessment.9 In previous work, the AI ECG mapping process provided an average spatial accuracy for VT and PVCs of 13 mm and 11 mm, respectively.7 Mapping accuracy in this study was sufficient for the surgical ablation process to eliminate PVCs and VT in all patients in this cohort, with no evidence of ablation failure at a median of 3 months of follow-up.
In addition to arrhythmia source localization, the AI CT analysis provides both patient-specific anatomical information and regional wall thickness analysis.9 In previous work, regions of left ventricular wall thinning correlated with regions of scar and border-zone tissue.19 However, scar localization is often nonspecific, frequently being widespread in patients with advanced structural heart disease.
Thus, the combination of AI arrhythmia mapping, patient-specific anatomy, and substrate localization facilitated the creation of a surgical arrhythmia ablation plan to address cardiac arrhythmias in all enrolled patients for this study. It also permitted establishment of a surgical arrhythmia ablation program at the University of California San Diego and Veterans Affairs Medical Center San Diego, increasing patient access to concomitant surgical ablation in patients at both centers with a clinically significant VA burden undergoing cardiothoracic surgery procedures.
Surgical Arrhythmia Ablation Demonstrates a High Procedural Success Rate
Data from these first 13 cases from the surgical ablation program demonstrate a high procedural success, with 84.6% patients achieving the primary end point at a minimum of 1 year follow-up. Reasons for the high success rate include the fact that surgical ablation is highly effective in accomplishing ablation due to direct visualization of target tissue and the surrounding substrate along with better catheter contact with the targeted site throughout ablation application. This reduces suboptimal ablation due to limitations in catheter contact and stability inherent in catheter ablation procedures.20 Importantly, the surgeon was able to assess ablation effectiveness by direct assessment of characteristic changes in myocardial appearance from ablation, have fewer constraints in ablation target access, and enhancing the continuity and completeness of ablation.21
We also highlight that as a result of the noninvasive CT mapping workflow, there was no additional mapping time added to the cardiopulmonary bypass time. The technology was incorporated into the workflow of 6 different surgeons, demonstrating the adaptability and ease-of-use for this workflow as well.
The excellent clinical results should be evaluated in the context of the small size of the study and a possible selection bias for the first few cases for the surgical ablation program. As such, the surgical ablation population studied here may be different than larger catheter-based trials22; these results should therefore be considered hypothesis-generating.
No Significant Increase in Procedural Complications
The excellent ablation results were achieved, whereas the rate of major complications (15.4%) was lower than the weighted average derived from available surgical literature,23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 which would be expected from the baseline surgical procedures alone (20.8%). The full list of complications risk is listed in Table 4. These data suggest that the risk/benefit profile of concomitant surgical ablation within indicated cardiothoracic surgery procedures is favorable, encouraging ongoing analysis of this approach.
It should be noted that minor complications were not compared with the published literature, given the heterogeneous nature of minor complication definitions, reporting, and data availability. Future studies in larger populations are required to better define the rates of both major and minor complications and provide more detailed comparisons to published data.
Limitations
Limitations to this study included a small sample size. Because of this, study analyses and comparisons should be considered hypothesis-generating. Larger, multicenter studies are required to more definitively assess surgical ablation efficacy and risks.
Second, there was no control arm in this study, because a routine surgical ablation program did not exist at the study institutions before the introduction of the AI ECG and CT analysis technologies. Future randomized studies may consider a control arm of patients with indicated cardiac surgery undergoing separate surgical management and separate catheter-based ablation.
Conclusions
AI ECG and CT analysis provides noninvasive information regarding arrhythmia source location, patient-specific anatomy, and localization of arrhythmia-sustaining substrate, which facilitated surgical arrhythmia ablation. Surgical ablation guided by combined ECG and CT analysis demonstrated a high procedural success at 1 year and did not increase the complication rate above the rate expected from published literature.
Conflict of Interest Statement
Dr Krummen reported consulting and equity in Vektor Medical Inc. Dr Ho reported founder shares in Vektor Inc and consulting for Kestra Inc. All other authors reported no conflicts of interest.
The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest.
Footnotes
This work was supported by the ACC/Merck Research Fellowship Award (to K.S.); American Heart Association (AHA 19CDA34760021), National Institutes of Health (NIH 1KL2TR001444), and Muggleton Family via the Artificial Intelligence Arrhythmia Research Fund at UC San Diego Health (to G.H.); and a grant from the UCSD Galvanizing Engineering in Medicine Foundation (to D.E.K).
Appendix E1
Table E1.
Postablation follow-up results
| Ejection fraction/arrhythmia burden | Preablation | 1 month | 1 year |
|---|---|---|---|
| Ejection fraction % | |||
| PVC (n = 9) | 52.2 ± 17.5% | 44.8 ± 17.0% (P = .31) | 52.3 ± 16.4% (P = .8) |
| VT (n = 4 at 1 mo, n = 3 at 1 y) | 30 ± 19.6% | 26 ± 11.3% (P = .8) | 32 ± 12.1% (P = .82) |
| PVC burden | 20.6 ± 15.9% | 2.6 ± 2.3% (P < .01) | 2.8 ± 2.6% (P < .01) |
| ICD shocks | 1.5 ± 2.6 shocks | 0 | 0 |
PVC, Premature ventricular contraction; ICD, implantable cardioverter-defibrillator.
Table E2.
Calculation of comparison rate of major complications using weighted rates from the published literature
| Surgery type | Number of study patients | Average literature-reported major complication rate |
|---|---|---|
| Mitral valve repair32,33 | 4 | 12% |
| Durable LVAD implantation30,31 | 3 | 45% |
| CABG Surgery28,29 | 2 | 11% |
| Pulmonary thromboendarterectomy26,27 | 1 | 15% |
| Thoracic aorta repair24,25 | 1 | 20% |
| Anomalous coronary artery repair23 | 1 | 10% |
| (Primary surgical arrhythmia ablation) | (1) | (excluded from analysis) |
| Weighted average for patients undergoing concomitant surgical arrhythmia ablation (expected complication rate for study) | 12 | 20.8% |
LVAD, Left ventricular assist device; CABG, coronary artery bypass graft surgery.
References
- 1.Sadjadieh G., Sajadieh A. Prognosis after finding incidental ventricular tachycardia on ambulatory electrocardiogram-recording. Am J Cardiol. 2021;150:60–64. doi: 10.1016/j.amjcard.2021.03.049. [DOI] [PubMed] [Google Scholar]
- 2.Dukes J.W., Dewland T.A., Vittinghoff E., et al. Ventricular ectopy as a predictor of heart failure and death. J Am Coll Cardiol. 2015;66(2):101–109. doi: 10.1016/j.jacc.2015.04.062. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Turagam M.K., Vuddanda V., Atkins D., et al. Hemodynamic support in ventricular tachycardia ablation: an international VT ablation center collaborative group study. JACC Clin Electrophysiol. 2017;3(13):1534–1543. doi: 10.1016/j.jacep.2017.07.005. [DOI] [PubMed] [Google Scholar]
- 4.Cronin E.M., Bogun F.M., Maury P., et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm. 2020;17(1):e2–e154. doi: 10.1016/j.hrthm.2019.03.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Bhavani S.S., Tchou P., Chung M., Fahmy T., Gillinov A.M. Intraoperative electro-anatomical mapping and beating heart ablation of ventricular tachycardia. Ann Thorac Surg. 2006;82(3):1091–1093. doi: 10.1016/j.athoracsur.2005.12.042. [DOI] [PubMed] [Google Scholar]
- 6.Krummen D.E., Villongco C.T., Ho G., et al. Forward-solution noninvasive computational arrhythmia mapping: the VMAP study. Circ Arrhythm Electrophysiol. Sep 2022;15(9) doi: 10.1161/CIRCEP.122.010857. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Fox S.R., Toomu A., Gu K., et al. Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use. J Cardiovasc Electrophysiol. 2024;35(5):916–928. doi: 10.1111/jce.16237. [DOI] [PubMed] [Google Scholar]
- 8.Ho G., Atwood T.F., Bruggeman A.R., et al. Computational ECG mapping and respiratory gating to optimize stereotactic ablative radiotherapy workflow for refractory ventricular tachycardia. Heart Rhythm O2. 2021;2(5):511–520. doi: 10.1016/j.hroo.2021.09.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Ho G., Villongco C.T., Han F.T., et al. Non-invasive co-localization of ventricular tachycardia isthmuses and scar using integrated artificial intelligence-based CT and ECG analysis. Heart Rhythm. 2024;21(5):S628. doi: 10.1016/j.hrthm.2024.03.1563. [DOI] [Google Scholar]
- 10.Englert F., Bahlke F., Erhard N., et al. VT ablation based on CT imaging substrate visualization: results from a large cohort of ischemic and non-ischemic cardiomyopathy patients. Clin Res Cardiol. 2024;113(10):1478–1484. doi: 10.1007/s00392-023-02321-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Buxton A.E., Lee K.L., Fisher J.D., Josephson M.E., Prystowsky E.N., Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease. multicenter unsustained tachycardia trial investigators. N Engl J Med. 1999;341(25):1882–1890. doi: 10.1056/NEJM199912163412503. [DOI] [PubMed] [Google Scholar]
- 12.Keyt L.K., Atwood T., Bruggeman A., et al. Successful noninvasive 12-lead ECG mapping-guided radiotherapy of inaccessible ventricular tachycardia substrate due to mechanical valves. JACC Case Rep. 2023;15 doi: 10.1016/j.jaccas.2023.101870. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Shahian D.M., Jacobs J.P., Badhwar V., et al. The society of thoracic surgeons 2018 adult cardiac surgery risk models: part 1—background, design considerations, and model development. Ann Thorac Surg. 2018;105(5):1411–1418. doi: 10.1016/j.athoracsur.2018.03.002. [DOI] [PubMed] [Google Scholar]
- 14.Josephson M.E., Harken A.H., Horowitz L.N. Endocardial excision: a new surgical technique for the treatment of recurrent ventricular tachycardia. Circulation. 1979;60(7):1430–1439. doi: 10.1161/01.cir.60.7.1430. [DOI] [PubMed] [Google Scholar]
- 15.Choi E.K., Nagashima K., Lin K.Y., et al. Surgical cryoablation for ventricular tachyarrhythmia arising from the left ventricular outflow tract region. Heart Rhythm. 2015;12(6):1128–1136. doi: 10.1016/j.hrthm.2015.02.016. [DOI] [PubMed] [Google Scholar]
- 16.Anter E., Hutchinson M.D., Deo R., et al. Surgical ablation of refractory ventricular tachycardia in patients with nonischemic cardiomyopathy. Circ Arrhythm Electrophysiol. 2011;4(4):494–500. doi: 10.1161/CIRCEP.111.962555. [DOI] [PubMed] [Google Scholar]
- 17.Hadjis A., Frontera A., Limite L.R., et al. Complete electroanatomic imaging of the diastolic pathway is associated with improved freedom from ventricular tachycardia recurrence. Circ Arrhythm Electrophysiol. 2020;13(9) doi: 10.1161/CIRCEP.120.008651. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Jiang R., Beaser A.D., Aziz Z., Upadhyay G.A., Nayak H.M., Tung R. High-density grid catheter for detailed mapping of sinus rhythm and scar-related ventricular tachycardia: comparison with a linear duodecapolar catheter. JACC Clin Electrophysiol. 2020;6(3):311–323. doi: 10.1016/j.jacep.2019.11.007. [DOI] [PubMed] [Google Scholar]
- 19.Yamashita S., Sacher F., Hooks D.A., et al. Myocardial wall thinning predicts transmural substrate in patients with scar-related ventricular tachycardia. Heart Rhythm. 2017;14(2):155–163. doi: 10.1016/j.hrthm.2016.11.012. [DOI] [PubMed] [Google Scholar]
- 20.Subramanian M., Atreya A.R., Saggu D.K., Yalagudri S., Calambur N. Catheter ablation of ventricular tachycardia: strategies to improve outcomes. Front Cardiovasc Med. 2023;10 doi: 10.3389/fcvm.2023.966634. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Sosa E., Scanavacca M., d'Avila A., Pilleggi F. A new technique to perform epicardial mapping in the electrophysiology laboratory. J Cardiovasc Electrophysiol. 1996;7(6):531–536. doi: 10.1111/j.1540-8167.1996.tb00559.x. [DOI] [PubMed] [Google Scholar]
- 22.Sapp J.L., Tang A.S.L., Parkash R., et al. Catheter ablation or antiarrhythmic drugs for ventricular tachycardia. N Engl J Med. 2025;392(8):737–747. doi: 10.1056/NEJMoa2409501. [DOI] [PubMed] [Google Scholar]
- 23.Gentile F., Castiglione V., De Caterina R. Coronary artery anomalies. Circulation. 2021;144(12):983–996. doi: 10.1161/CIRCULATIONAHA.121.055347. [DOI] [PubMed] [Google Scholar]
- 24.Daye D., Walker T.G. Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management. Cardiovasc Diagn Ther. 2018;8(suppl 1):S138–S156. doi: 10.21037/cdt.2017.09.17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.De Paulis S., Arlotta G., Calabrese M., et al. Postoperative intensive care management of aortic repair. J Pers Med. 2022;12(8):1351. doi: 10.3390/jpm12081351. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Delcroix M., Pepke-Zaba J., D'Armini A.M., et al. Worldwide CTEPH registry: long-term outcomes with pulmonary endarterectomy, balloon pulmonary angioplasty, and medical therapy. Circulation. 2024;150(17):1354–1365. doi: 10.1161/CIRCULATIONAHA.124.068610. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Brookes J.D.L., Li C., Chung S.T.W., et al. Pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension: a systematic review. Ann Cardiothorac Surg. 2022;11(2):68–81. doi: 10.21037/acs-2021-pte-25. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Lawton J.S., Tamis-Holland J.E., Bangalore S., et al. 2021 ACC/AHA/SCAI guideline for coronary artery revascularization: a report of the American College of Cardiology/American Heart Association Joint Committee on clinical practice guidelines. Circulation. 2022;145(3):e18–e114. doi: 10.1161/CIR.0000000000001038. [DOI] [PubMed] [Google Scholar]
- 29.Jawitz O.K., Gulack B.C., Brennan J.M., et al. Association of postoperative complications and outcomes following coronary artery bypass grafting. Am Heart J. 2020;222:220–228. doi: 10.1016/j.ahj.2020.02.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Tedford R.J., Leacche M., Lorts A., Drakos S.G., Pagani F.D., Cowger J. Durable mechanical circulatory support: JACC scientific statement. J Am Coll Cardiol. 2023;82(14):1464–1481. doi: 10.1016/j.jacc.2023.07.019. [DOI] [PubMed] [Google Scholar]
- 31.Shah P., Yuzefpolskaya M., Hickey G.W., et al. Twelfth interagency registry for mechanically assisted circulatory support report: readmissions after left ventricular assist device. Ann Thorac Surg. 2022;113(3):722–737. doi: 10.1016/j.athoracsur.2021.12.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Oh N.A., Kampaktsis P.N., Gallo M., et al. An updated meta-analysis of MitraClip versus surgery for mitral regurgitation. Ann Cardiothorac Surg. 2021;10(1):1–14. doi: 10.21037/acs-2020-mv-24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Ko K., de Kroon T.L., Post M.C., et al. Minimally invasive mitral valve surgery: a systematic safety analysis. Open Heart. 2020;7(2) doi: 10.1136/openhrt-2020-001393. [DOI] [PMC free article] [PubMed] [Google Scholar]