Skip to main content
. 2026 Mar 28;20(1):96. doi: 10.1186/s13065-026-01780-7

Table 3.

Potentiometric selectivity of sensors 2 and 10 calculated according to IUPAC rules

Sensor 2 Sensor 10
Interfering ions log Inline graphic Inline graphic Interfering ions log Inline graphic Inline graphic
Cr+3 –1.05 8.91 × 10–2 Na+ –1.69 2.04 × 10–2
Cu2+ –1.35 4.47 × 10–2 Cu2+ –1.72 1.91 × 10–2
Al3+ –1.93 1.17 × 10–2 Sr2+ –1.83 1.45 × 10–2
Na+ –2.09 8.13 × 10–3 Pb2+ –1.89 1.29 × 10–2
Li+ –2.13 7.41 × 10–3 Al3+ –1.93 1.17 × 10–2
Ca2+ –2.14 7.24 × 10–3 In3+ –2.06 8.71 × 10–3
Cd2+ –2.26 5.49 × 10–3 Cd2+ –2.16 6.92 × 10–3
Ni2+ –2.36 4.36 × 10–3 Ni2+ –2.23 5.89 × 10–3
Pb2+ –2.54 2.88 × 10–3 Co2+ –2.24 5.75 × 10–3
Zn2+ –2.57 2.69 × 10–3 Ca2+ –2.33 4.68 × 10–3
Gd3+ –2.60 2.51 × 10–3 Gd3+ –2.67 2.14 × 10–3
Sr2+ –2.70 1.99 × 10–3 Mg2+ –2.68 2.09 × 10–3
Mg2+ –2.77 1.70 × 10–3 Cr+3 –2.91 1.23 × 10–3
Nd3+ –2.94 1.15 × 10–3 Li+ –2.94 1.15 × 10–3
Mn2+ –2.97 1.07 × 10–3 Zn2+ –3.14 7.24 × 10–4
Co2+ –3.04 9.12 × 10–4 Nd3+ –3.28 5.25 × 10–4
In3+ –4.74 1.82 × 10–5 Mn2+ –3.58 2.63 × 10–4
K+ –5.51 3.10 × 10–6 K+ –4.05 8.91 × 10–5