Table 5.
Statistics of wall heat flux and total heat transfer in 40 cases of nasal cavity model.
| Group | Average area m2 | Average heat flux W/m2 | Gross heat (W) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Zone1 | Zone2 | Zone3 | Zone4 | Zone1 | Zone2 | Zone3 | Zone4 |
|
||
| a1 | 0.00132 | 0.00569 | 0.00737 | 0.00219 | 437.84 | 140.07 | 89.06 | 51.6 | 127.6 | 2.11 |
| a2 | 0.00113 | 0.00635 | 0.00831 | 0.00205 | 535.98 | 174.10 | 70.87 | 39.1 | 128.2 | 2.28 |
| a3 | 0.00129 | 0.00528 | 0.00786 | 0.00185 | 540.6 | 221.3 | 91.3 | 60.9 | 172.4 | 2.80 |
| b1 | 0.00126 | 0.00584 | 0.00822 | 0.0020 | 509.35 | 199.04 | 78.92 | 45.5 | 147.3 | 2.55 |
| b2 | 0.00109 | 0.00634 | 0.00784 | 0.0021 | 520.90 | 144.15 | 75.93 | 44.6 | 123.7 | 2.14 |
| c1 | 0.00089 | 0.0055 | 0.00684 | 0.00222 | 664.141 | 152.08 | 82.23 | 47.4 | 136.7 | 2.11 |
| c2 | 0.00123 | 0.00597 | 0.00777 | 0.00202 | 501.446 | 185.49 | 80.7 | 45.8 | 139.9 | 2.37 |
| c3 | 0.00136 | 0.00685 | 0.01034 | 0.00195 | 434.79 | 167.67 | 62.08 | 40.6 | 117.9 | 2.41 |
| d1 | 0.00116 | 0.00652 | 0.00830 | 0.00187 | 538.01 | 159.9 | 71.05 | 43.5 | 128.2 | 2.28 |
| d2 | 0.00122 | 0.00551 | 0.00779 | 0.00224 | 540.09 | 195.01 | 85.16 | 47.1 | 143.7 | 2.40 |
| all | 0.00119 | 0.00604 | 0.00806 | 0.00204 | 519.478 | 176.44 | 77.69 | 45.1 | 137.7 | 2.39 |