. 2026 Mar 21;9:367. doi: 10.1038/s41746-026-02558-w

Table 4.

Comparison of simulated and reference hemodynamic values at 72–96 h in non-cooled neonates58

GA (wk) Source CO (L/min) CI (L/min/m2) HR (bpm) SV (mL)
≤28 Our study 0.24± 0.02 2.62± 0.26 148± 8.5 1.64± 0.14
Reference 0.23± 0.03 2.31± 0.26 149± 11.4 1.56± 0.28
29–30 Our study 0.25± 0.01 2.51± 0.12 145± 15.4 1.73± 0.16
Reference 0.29± 0.06 2.45± 0.24 145± 8.7 1.99± 0.44
31–32 Our study 0.33± 0.03 2.69± 0.25 142± 10.7 2.35± 0.19
Reference 0.35± 0.07 2.69± 0.36 142± 8.9 2.53± 0.47
33–34 Our study 0.35± 0.07 2.54± 0.31 142± 7.5 2.48± 0.50
Reference 0.35± 0.07 2.54± 0.32 142± 15.7 2.49± 0.60
35–36 Our study 0.40± 0.05 2.64± 0.32 136± 10.6 2.96± 0.24
Reference 0.43± 0.08 2.64± 0.33 136± 13.5 3.22± 0.70
37–38 Our study 0.46± 0.11 2.49± 0.19 131± 10.0 3.50± 0.88
Reference 0.47± 0.10 2.49± 0.39 131± 11.9 3.67± 0.72
39–41 Our study 0.61± 0.07 2.60± 0.30 126± 12.8 4.87± 0.43
Reference 0.53± 0.14 2.60± 0.54 126± 12.1 4.24± 0.89

Reported values are mean± standard deviation.