Comparison of ResNES predictions with FEM and experimental results

Grid density Sample number Frequency order ResNES predictions (Hz) FEM Results (Hz) Deviation Between ResNES and FEM Experimental Results (Hz) Deviation Between ResNES and Experiment
8 × 8 1 First-order 255.4 249.1 2.53% 243.1 5.06%
Second-order 327.2 321.2 1.87% 314.9 3.91%
2 First-order 432.8 424.3 2.00% 453.0 -4.46%
Second-order 595.2 598.3 -0.52% 620.2 -4.03%
10 × 10 3 First-order 832.4 844.5 -1.43% 814.1 2.25%
Second-order 1573.2 1550.9 1.44% 1645.2 -4.38%
4 First-order 865.0 872.7 -0.88% 908.7 -4.81%
Second-order 2163.8 2207.3 -1.97% 2260.8 -4.29%
12 × 12 5 First-order 942.5 957.3 -1.55% 963.8 -2.21%
Second-order 1620.3 1650.9 -1.85% 1665.1 -2.69%
6 First-order 1890.3 1857.1 1.79% 1823.5 3.66%
Second-order 4589.4 4501.2 1.96% 4338.3 5.79%