Abstract
To address the limitations of existing approachestargeted next-generation sequencing (NGS) and simplex droplet digital PCR (ddPCR) assaysfor circulating tumor DNA (ctDNA) detection in uveal melanoma (UM), we developed and validated mutation-agnostic multiplex drop-off ddPCR assays at the targeted loci as a novel strategy. Two multiplex drop-off ddPCR assays covering hotspot mutations in GNAQ p.Q209, GNA11 p.Q209, p.R183, SF3B1 p.R625, PLCB4 p.D630, and CYSLTR2 p.L129Q were developed. Analytical sensitivity and specificity were determined. Clinical validation was performed using DNA from tumor tissue and plasma samples from a prospective cohort of Metastatic UM (MUM) (ALCINA, NCT02866149) or archived clinical samples. The multiplex assays demonstrated high sensitivity, with detection limits ranging from 0.06% to 0.13%, comparable to those of simplex ddPCR assays. Somatic mutations in tumor DNA (N = 12) were successfully identified using the multiplex assays, and all were confirmed by NGS. ctDNA was detected in 62.8% of 43 plasma samples, with a median mutant allele frequency (MAF) of 2.9% (interquartile range [IQR] 0.6–7.4%). Strong concordance with simplex ddPCR results was observed (r = 0.98, p < 0.0001 for multiplex 1, N = 32; r = 0.97, p < 0.0001 for multiplex 2, N = 11), further supporting the accuracy of the multiplex assays. Our mutation-agnostic multiplex drop-off ddPCR assays provide a sensitive, specific, and cost-effective alternative to targeted NGS and simplex ddPCR for ctDNA monitoring in UM. By minimizing reliance on prior knowledge of tumor genotype with NGS, these assays enable broader clinical applicability for real-time treatment monitoring in UM.


Introduction
Circulating tumor DNA (ctDNA) has emerged as a promising biomarker for predicting and monitoring treatment response across a wide range of cancer types. − However, due to its low abundance in circulation and the substantial background of nontumor-derived DNA, ctDNA detection requires highly sensitive and specific methodologies. Currently, targeted next-generation sequencing (NGS) and droplet digital PCR (ddPCR) are the two most widely used platforms for ctDNA analysis, each offering distinct strengths and limitations. As a result, the choice of technique often depends on the study objectives, available resources, and expected genetic landscape of the tumor.
Uveal melanoma (UM), the most common primary intraocular malignancy in adults, has an annual incidence of 2–8 cases per million. Despite effective local control of the primary tumor, up to 50% of patients ultimately develop metastatic diseasemost frequently in the liver (∼90% of cases)with a median progression-free survival (PFS) of 3–4 months and a median overall survival (OS) of 10–16 months. UM is genetically distinct from many other solid tumors, including cutaneous melanoma, and is characterized by a low tumor mutational burden and a narrow spectrum of recurrent hotspot mutations. Activating mutations in GNAQ and GNA11 are most common (∼85–94%), while PLCB4 and CYSLTR2 mutations occur less frequently (∼2.5–4% and ∼2–4%, respectively), with all four genes being mutated in a mutually exclusive manner. ,
Given this well-defined mutational landscape, ddPCR offers practical advantages for ctDNA analysis in UM: it is cost-effective, rapid, and requires no bioinformatics support. Conventional droplet digital PCR is a highly sensitive and quantitative technology for detecting rare nucleic acid variants. Different from bulk PCR, ddPCR partitions DNA molecules and the necessary PCR reagents into thousands of nanoliter-sized droplets, each acting as an independent microreaction. Each droplet ideally contains either zero or one DNA molecule. Following PCR amplification, droplets containing the target sequence generate a fluorescent signal, while negative droplets remain nonfluorescent. This technology provides high sensitivity for detecting rare variants and low-frequency mutations, making it particularly suitable for ctDNA analysis.
However, conventional ddPCR assays are mutation-specific, necessitating prior tumor genotypingtypically via NGSfor assay design. In contrast, targeted NGS allows mutation-agnostic profiling and can detect rare variants and copy-number alterations, but it is generally more resource-intensive and time-consuming. To overcome these limitations, drop-off ddPCR assays were developed. This approach uses two adjacent hydrolysis probes complementary to the template: one targeting the hotspot mutation region and the other targeting a nearby reference region. Any nucleotide change within the hotspot region disrupts the binding of the mutation probe, resulting in loss of its signal while the reference probe continues to bind and generate fluorescence. , This design allows the detection of any variant within the targeted hotspot region without prior knowledge of the exact mutation. Given the limited mutational spectrum of UM, different from other solid tumors, a small set of multiplex drop-off ddPCR assays can cover the majority of clinically relevant hotspot mutations, enabling mutation-agnostic ctDNA detection at the defined loci.
Although our group and others have demonstrated the clinical utility of ctDNA for monitoring treatment response in metastatic UM (MUM) using both targeted NGS and conventional ddPCR, − there remains a need for a more practical, efficient, and clinically accessible ctDNA detection strategy tailored to the unique genetic features of UM. In this study, we developed two multiplex drop-off ddPCR assays to detect key UM hotspot mutations at the defined loci in a mutation-agnostic manner. We evaluated the analytical performance and clinical utility of these novel assays for ctDNA detection in patients with MUM. Our findings demonstrate that this approach is sensitive, efficient, scalable, and mutation-agnostic at the targeted loci, making it well-suited for real-time disease monitoring and highly promising for integration into routine clinical practice.
Experimental Section
Development of Multiplex Drop-Off ddPCR Assays
As previously reported, , drop-off ddPCR design includes two hydrolysis probes within the same PCR fragment: a reference probe (REF), which binds to a nonvariable region, and an adjacent target probe (drop-off), which specifically binds to the wild-type (WT) sequence at a hotspot mutation site. In the presence of a WT allele, both the REF and drop-off probes hybridize evenly, generating a dual fluorescence signal (VIC+/FAM+, Cy5+/Cy5.5+, or ROX+/ATTO590+). In contrast, if a variant allele (such as a mutation, insertion, or deletion) is present, the drop-off probe fails to hybridize, resulting in loss of its corresponding signal, while the REF signal remains detectable.
Prior to constructing the multiplex assays, we designed and validated simplex drop-off ddPCR assays targeting GNAQ p.Q209, GNA11 p.Q209, GNA11 p.R183, SF3B1 p.R625, and PLCB4 p.D630 positions and a conventional simplex ddPCR assay targeting CYSLTR2 p.L129Q c.386T>A mutation. Assay design followed standard principles for ddPCR assays. Primers and probes were designed to avoid sequence interactions and to produce amplicons of comparable lengths to maintain a consistent amplification efficiency. Multiplex 1 composed with 3 drop-off ddPCR assays targets clustered hotspot mutations in GNAQ p.Q209, GNA11 p.Q209, and GNA11 p.R183 positions with six different fluorophores (VIC, FAM, Cy5, Cy5.5, ROX, and ATTO590). Multiplex 2 composed with 2 drop-off ddPCR assays and one simplex ddPCR assay targets clustered hotspot mutations in SF3B1 p.R625 and PLCB4 p.D630 positions and CYSLTR2 p.L129Q c.386T>A mutation, respectively, with also six different fluorophores (VIC, FAM, Cy5, Cy5.5, ROX, and ATTO590) (Figure A,B).
1.
Multiplex ddPCR assays targeting clustered hotspot mutations in different genes associated with UM. (A) Schematic representation of the principle of the multiplex assay (example shown: multiplex 1). (B) Multiplex 1 consists of three drop-off ddPCR assays targeting clustered hotspot mutations at GNAQ p.Q209, GNA11 p.Q209, and GNA11 p.R183, using six distinct fluorophores (VIC, FAM, Cy5, Cy5.5, ROX, and ATTO590). (C) Multiplex 2 consists of two drop-off ddPCR assays and one conventional simplex ddPCR assay, targeting hotspot mutations at SF3B1 p.R625, PLCB4 p.D630, and the CYSLTR2 p.L129Q (c.386T>A) mutation, also using six fluorophores (VIC, FAM, Cy5, Cy5.5, ROX, and ATTO590).
Following assay design, gradient temperature experiments were performed with the multiplex drop-off ddPCR assays to determine the optimal annealing temperature for all assays within the same multiplex (Figure S1).
Validation of Multiplex ddPCR Assays
To validate these assays, DNA from cell lines including OMM2.3 (GNAQ p.Q209P c.626A>C), MP46 (GNAQ p.Q209L c.626A>T), and OMM1 (GNA11 p.Q209L c.626A>T), tumor tissues carrying mutations such as GNAQ c.626A>G, GNAQ c.625_626delCAinsTT, GNA11 c.547C>T, SF3B1 c.1874G>A, and SF3B1 c.1873C>T, or synthetic oligonucleotides containing specific mutations (PLCB4 c.1888G>A, PLCB4 c.1888G>T, and CYSLTR2 c.386T>A) was used as positive controls. Genomic DNA from healthy donors procured from Promega (Madison, WI, USA) served as negative controls. The multiplex ddPCR assays were performed using the BioRad QX600 system (BioRad Laboratories, Hercules, CA, USA) with 900 nM of each primer, 400 nM of each probe, under the following conditions: amplification conditions included an initial cycle at 95 °C for 10 min, followed by 40 cycles at 94 °C for 30 s and hybridization at 62 °C for multiplex 1 and 61 °C for multiplex 2 for 60 s, concluding with a cycle at 98 °C for 10 min. Droplets were generated using Bio-Rad QX200 Droplet Generators (BioRad Laboratories, Hercules, CA, USA). Successful droplet generation required the formation of more than 10,000 droplets per sample. Cluster thresholding, quantification, and signal interpretation were performed with QX Manager 2.1 software following the manufacturer’s recommendations. Spectral crosstalk and channel interference are automatically corrected by the QX600 system and QX Manager 2.1 software.
Droplets were manually assigned as WT or mutant (MUT) based on their fluorescence amplitude: WT: VIC+/FAM+, Cy5+/Cy5.5+, or ROX+/ATTO590+, MUT: FAM+/VIC–/low, Cy5.5+/Cy5–/low, or ATTO590+/ROX–/low for multiplex 1 and FAM+/VIC–/low, Cy5+/Cy5.5–/low, or ROX+/ATTO590–/low for multiplex 2.
The MAFs were calculated as follows: copy numbers of MUT/(copy numbers of WT + copy numbers of MUT). All experiments met the digital MIQE for digital PCR data publication. Primers and probes are listed in Table S1.
In Vitro Performance of Multiplex ddPCR Assays
The false-positive rate for each assay was estimated using ≥ 26 replicates of WT DNA, as previously described. , The limit of blank (LOB) was defined as the upper 95% confidence limit of mean false-positive measurements and was calculated using Formula 1: , where is the mean events in blank samples, SDblank is the standard deviation, and n is the number of blank measurements. Analytical sensitivity was determined using serial dilutions of mutation-carrying DNA in WT DNA (total input DNA: 15 ng), with MAFs ranging from 5 to 0.01%. The limit of detection (LOD) was defined as the lowest mutant ratio reliably distinguishable from the LOB value. Analytical sensitivity and specificity has been evaluated using cell line, tumor-derived, or synthetic oligonucleotides containing specific mutations (GNAQ c.626A>C, c.626A>T c.626A>G, and c.625_626delCAinsTT, GNA11 c.626A>T, GNA11 c.547C>T for multiplex 1, and PLCB4 c.1888G>T and c.1888G>A, CYSLTR2 c.386T>A, SF3B1 c.1874G>A and c.1873C>T for multiplex 2) and genomic DNA from healthy donors.
Identification of Trackable Somatic Mutations in Tumor DNA
Archived tumor samples (N = 12), either from the primary tumor or a metastatic deposit, were retrieved from the Pathology department. Tumor DNA was extracted from macrodissected tumor tissue (Macherey-Nagel NucleoSpin Tissue kit) and subjected to whole exome sequencing (WES) or a large amplicon-based targeted NGS panel developed at Institut Curie, covering 483 genes (Qiagen Qiaseq) or tested with multiplex drop-off ddPCR assays.
Validation in Clinical Plasma Samples
Forty-three plasma samples were analyzed in this study. Fifteen samples were obtained from the prospective ALCINA study (NCT02866149), and twenty-eight were archived clinical plasma samples from the Genetics Unit of the Curie Institute. All plasma samples were from MUM patients receiving tebentafusp and were collected at various time points, either before or after treatment. Written informed consent was obtained from all patients.
DNA extraction from plasma samples was performed using the QIAmp Circulating Nucleic Acid Kit (Qiagen, Hilden, Germany) following the manufacturer’s instructions. The quantification of extracted DNA was conducted using the dsDNA HS Assay on a Qubit 2.0 fluorometer (Invitrogen, Carlsbad, CA, USA). Extracted DNA samples were stored at −20 °C until further analysis.
These samples were analyzed using multiplex ddPCR assays in parallel with conventional simplex droplet digital PCR assays. Primers and probes of conventional simplex ddPCR assays are previously described.
Data Analysis
Samples were considered positive when the MAF exceeded the LOD, with specific positive droplet counts required per mutation type: more than 5 positive droplets for GNAQ p.Q209, GNA11 p.Q209, GNA11 p.R183, and SF3B1 R625, 4 positive droplets for PLCB4 D630 position, and 1 positive droplet for CYSLTR2 L129Q c.386T>A per analysis. The following Formula 2 was used for the calculation, where λFP is the ratio of the number of false-positive droplets to the number of tests for the assay:
Statistical Analyses
Pearson coefficient was used for assessing correlations. Statistical analyses were conducted using GraphPad Prism (version 8.0).
Results and Discussion
Development and Optimization of Mutation-Agnostic Multiplex Drop-Off ddPCR Assays
A major advantage of drop-off ddPCR assays is their ability to detect all mutations occurring at a given positionwhether insertions, deletions, or point mutationswithout prior knowledge of the specific alteration. , The decision to use a simplex assay for CYSLTR2 p.L129Q was based on its single predominant hotspot mutation, making a drop-off approach unnecessary. SF3B1 p.R625 mutations occur in approximately 15–25% of cases and are associated with a more favorable prognosis. Thus, a drop-off assay for p.R625 was included in multiplex 2. Despite the well-established role of BAP1 as a tumor suppressor gene associated with poor prognosis in UM, its deleterious mutations are distributed across the gene, making them unsuitable for ddPCR detection. However, the absence of a BAP1-targeted assay does not compromise the overall efficacy of our multiplex approach for ctDNA detection, as BAP1 mutations co-occur with mutations in GNAQ or GNA11, which are reliably detectable. GNAQ p.R183 was excluded from the multiplex due to primer and probe competition. Given its low mutation frequency (approximately 4%), a simplex ddPCR assay was developed for GNAQ p.R183, which can be utilized when no mutations are detected with multiplex assays.
Following the assay design, temperature gradient experiments were performed to determine the optimal annealing temperatures for the two multiplex assays. As shown in Figure S1, the optimal annealing temperature was defined as 62 °C for multiplex 1 and 61 °C for multiplex 2. To further improve cluster separation in multiplex assays, different primer and probe concentrations were tested; however, no improvement was observed (data not shown). For multiplex 1, DNA from cell lines or tumor tissues carrying the following mutations: GNAQ c.626A > C, GNAQ c.626A > T, GNAQ c.626A > G, GNAQ: c.625_626delCAinsTT, GNA11 c.626A > T, and GNA11 c.547C>T was used as positive controls. As shown in Figures A and S2A, a clear separation was observed between WT clusters (VIC+/FAM+ for GNAQ mutations, Cy5+/Cy5.5+ for GNA11 c.626A>T, and ROX+/ATTO590+ for GNA11 c.547C>T mutations) and MUT clusters (FAM+/VIC–/low for GNAQ mutations; Cy5.5+/Cy5–/low for GNA11 c.626A>T; and ATTO590+/ROX–/low for GNA11 c.547C>T mutations). Although the intensity of WT and MUT clusters for GNA11 c.547C>T was close to that of negative clusters, three distinct clusters were still clearly observed.
2.
Representative 2D scatter plots from multiplex 1 (A) and multiplex 2 (B) drop-off ddPCR assays. (A) DNA from tumors or cell lines harboring known mutations (GNA11 c.626A > T, GNAQ c.626A > C, or GNA11 c.547C>T) was used as positive controls, while wild-type (WT) genomic DNA served as a negative control. Droplet clusters corresponding to WT alleles, mutant (MUT) alleles, and no DNA template are shown in different colors: VIC-FAM assays: WT (blue), MUT (green), no template (gray). Cy5.5-Cy5 assays: WT (purple), MUT (red), no template (gray); ROX-ATTO590 assays: WT (light blue), MUT (dark red), no template (gray). (B) DNA from tumors or synthetic oligonucleotides carrying SF3B1 c.1874G>A, CYSLTR2 c.386T>A, or PLCB4 c.1888G>T mutations was used as positive controls; WT genomic DNA was used as a negative control. Droplet clusters corresponding to WT alleles, mutant (MUT) alleles, and no DNA template are shown in different colors: VIC-FAM assays: WT (blue), MUT (green), no template (gray). Cy5.5-Cy5 assays: WT (purple), MUT (red), no template (gray); ROX-ATTO590 assays: WT (dark red), MUT (light blue), no template (gray).
For multiplex 2, DNA from tumor tissues carrying SF3B1 c.1874G>A and SF3B1 c.1873C>T mutations and synthetic oligonucleotides carrying PLCB4 c.1888G>A, PLCB4 c.1888G>T, and CYSLTR2 c.386T>A mutations was used as positive controls. As shown in Figures B and S2B, a clear separation of WT and MUT clusters was also observed for multiplex 2. No or limited MUT droplets were detected in the negative control.
Analytical Performance of the Developed Multiplex Drop-Off ddPCR Assays
We further estimated the sensitivity and specificity of the two multiplex ddPCR assays by analyzing replicates of WT DNA and serial dilutions of cell lines, tumor-derived DNA, or synthetic oligonucleotides carrying the frequent hotspot mutations recapitulating MAF from 5 to 0.01%. For multiplex 1, DNA carrying the following mutationsGNAQ c.626A>C, c.626A>T, c.626A>G, c.625_626delCAinsTT, GNA11 c.626A>T, and GNA11 c.547C>Twas used separately as starting material for the serial dilutions (Figures A and S3A). For multiplex 2, DNA carrying PLCB4 c.1888G>T, c.1888G>A, CYSLTR2 c.386T>A, SF3B1 c.1874G>A, and c.1873C>T was used similarly (Figures B and S3B). The expected MAFs correspond to the theoretical allele fractions after each serial dilution. Knowing the MAF of the first dilution, subsequent dilutions were prepared using the same concentration of genomic DNA (gDNA), allowing for calculation of the theoretical MAF for each dilution step. The observed MAFs represent the values measured by ddPCR in our experiments (Figures and S3). The LOB was determined as follows: 0.05% for GNAQ p.Q209, GNA11 p.Q209, and GNA11 p.R183, 0.04% for SF3B1 p.R625, 0.03% for PLCB4 p.D630, and 0.00% for CYSLTR2 p.L129Q c.386T>A. The LOD was estimated at 0.06% for GNAQ c.626A>C, GNA11 c.626A>T, and SF3B1 c.1874G>A, 0.13% for GNA11 c.547C>T, and 0.03% for PLCB4 c.1888G>T and CYSLTR2 p.L129Q c.386T>A (Figure ). The LODs assessed using DNA carrying other mutations are described in Figure S3. For all these assays, the Pearson’s correlations were more than 0.99% between the expected and observed MAFs, suggesting an accurate quantification of mutations at a wide range of allelic frequencies.
3.
In vitro performance of the multiplex 1 (A) and multiplex 2 (B) ddPCR assays. The limit of detection (LOD) was estimated as the lowest mutant ratio that could be reliably distinguished from the LOB value. For multiplex 1, DNA carrying GNAQ c.626A>C, GNA11 c.626A>T, or GNA11 c.547C>T was used for positive controls for the estimation of LOD; for multiplex 2, DNA carrying PLCB4 c.1888G>T, CYSLTR2 c.386T>A, and SF3B1 1874G>A was used for positive controls for the estimation of LOD. N indicates the number of replicates performed for each dilution. To limit the total number of tests, fewer replicates (N = 1 or 6) were performed for higher MAF samples (e.g., 5%, 0.5%, and 0.25%), where measurement variability is lower. For lower MAF levels, more replicates (N = 8) were performed to improve the measurement reliability. Tests failing quality control criteria were excluded from the analysis.
The detection efficiency of the multiplex assay was evaluated by using DNA samples carrying different mutations. As shown in Figure S4, for multiplex 1, no differences were observed among the GNAQ mutations c.626A>C, c.626A>T, c.626A>G, and c.625_626delCAinsTT when the expected mutant allele frequency (MAF) was 0.13%. However, a difference was observed between the GNAQ c.626A>T and c.626A>G mutations at a higher expected MAF of 0.25%. Notably, multiplex 1 was able to detect all of these GNAQ mutations at the same limit of detection (LOD) (Figures and S3). Similar results were observed for multiplex 2 (Figures and S3 and S4).
Based on all tested mutations, when used in a mutation-agnostic manner, the applied LODs for multiplex 1 were 0.06% for GNAQ p.Q209 and GNA11 p.Q209 and 0.13% for GNA11 p.R183. For multiplex 2, the LODs were 0.06% for SF3B1 p.R625 and 0.03% for PLCB4 p.D630 and CYSLTR2 c.386T>A. Our results demonstrated a LOD of the multiplex drop-off ddPCR assays comparable to conventional simplex ddPCR assays.
Performance of Multiplex Drop-Off ddPCR Assays for Identification of Somatic Mutations in Tumor DNA
DNA from archived tumor tissue samples was analyzed by using targeted NGS and multiplex ddPCR assays to identify mutations for subsequent circulating tumor DNA (ctDNA) detection. As shown in Table , the multiplex ddPCR assays identified the same mutant genes as those detected by targeted NGS. However, the drop-off assays do not provide information on the exact nucleotide changes.
1. Identification of Somatic Mutations in Tumor DNA Using Multiplex Drop-Off ddPCR Assays.
| targeted
NGS |
multiplex
ddPCR assays |
|||||
|---|---|---|---|---|---|---|
| patients ID | DNA sources | mutations identified | MAF (%) | DNA sources | mutations identified | MAF (%) |
| P1 | eye | GNAQ c.626A>C p.Q209P | 36.4 | eye | GNAQ p.Q209 | 40.4 |
| P2 | liver met. | GNA11 c.547C>T p.R183C | 14.0 | liver met. | GNA11 p.R183 | 15.0 |
| P3 | liver met. | GNAQ c.625_626delCAinsTT p.Q209L | 47.0 | liver met. | GNAQ p.Q209 | 46.1 |
| P4 | liver met. | GNA11 c.626A>T p.Q209L | 25.2 | liver met. | GNA11 p.Q209 | 25.3 |
| P5 | liver met. | GNA11 c.626A>T p.Q209L | 26.0 | liver met. | GNA11 p.Q209 | 37.2 |
| P6 | eye | GNAQ c.626A>T p.Q209L | 40.2 | eye | GNAQ p.Q209 | 47.1 |
| P7 | eye | GNAQ c.626A>T p.Q209L | 18.8 | liver met. | GNAQ p.Q209 | 40.2 |
| P8 | eye | GNAQ c.626A>C p.Q209P | 7.0 | liver met. | GNAQ p.Q209 | 39.7 |
| P9 | eye | GNAQ c.626A>C p.Q209P | 40.2 | liver met. | GNAQ p.Q209 | 29.8 |
| P10 | liver met. | GNA11 c.626A>T p.Q209L | 16.8 | eye | GNA11 p.Q209 | 7.7 |
| P11 | liver met. | GNAQ c.626A>C p.Q209P | 41.6 | eye | GNAQ p.Q209 | 2.9 |
| P12 | liver met. | GNAQ c.626A>C p.Q209P | 55.9 | stomach met. | GNAQ p.Q209 | 35.9 |
For samples in which the same DNA from a single tumor source was analyzed using both methods (P1–P6), similar MAFs were observed (Table ). In cases where insufficient DNA was available for both analyses (P7 to P12), DNA was extracted either from the primary tumor or from metastatic sites. In these samples, the same mutationsor the same mutated geneswere detected, however, with different MAFs, as expected when analyzing different samplings of a tumor. Based on the identification of mutation-carrying genomic regions in tumor DNA using the multiplex ddPCR assays, the same assays could subsequently be applied for ctDNA detection in plasma samples.
Validation of Multiplex Drop-Off ddPCR Assays in Clinical Plasma Samples for Diagnostic Use
To assess the clinical performance of the multiplex drop-off ddPCR assays for ctDNA detection, we analyzed 43 plasma samples from patients with MUM. All samples were tested in parallel using conventional simplex ddPCR assays.
As shown in Figure A and Table S2, ctDNA was detected in 62.8% of plasma samples with a median MAF of 2.9% (IQR 0.6–7.4%). Multiplex assay 1 successfully detected ctDNA harboring GNA11 c.626A>T and GNAQ c.626A>C mutations, except for one sample with a low MAF (0.21%) that was detected only by simplex ddPCR. A strong correlation was observed for ctDNA detection by multiplex assay 1 and simplex ddPCR (r = 0.98, p < 0.0001, N = 32) (Figure B and Table S2), confirming the high accuracy of the assay.
4.
ctDNA levels (MAF) in ctDNA positive samples using multiplex (A) and comparison of performance between simplex and multiplex 1 (B) and multiplex 2 (C) ddPCR assays on detecting ctDNA from patients’ plasma. (A) N = 27, median = 2.9% (IQR = 0.6–7.4%). Errors bars are presented as median ± IQR. (B): Simplex ddPCR assays targeting specifically GNA11 p.Q209L c.626A>T and GNAQ p.Q209P c.626A>C were used. (C) Simplex SF3B1 p.R625 drop-off ddPCR assay was used for targeting different hotspot mutations in SF3B1.
As CYSLTR2 c.386T>A or PLCB4 p.D630 mutations are very rare in UM, no plasma samples carrying these alterations were available in our laboratory; the performance of multiplex assay 2 for ctDNA detection was validated using plasma samples harboring SF3B1 p.R625 mutation. As shown in Figure C and Table S2, ctDNA levels measured by multiplex assay 2 also correlated strongly with simplex ddPCR results (r = 0.97, p < 0.0001, N = 11), further supporting its reliability for ctDNA detection.
These results revealed a strong correlation between ctDNA detection using multiplex ddPCR and conventional simplex ddPCR assays. However, given the limited number of clinical samples tested and the absence of samples harboring the PLCB4 p.D630 and CYSLTR2 c.386T>A mutations, further validation is warranted.
Conclusions
To address the need for a mutation-agnostic, easily implementable, cost-effective, and rapid approach for ctDNA detection in MUM, we developed two multiplex drop-off ddPCR assays targeting the prevalent hotspot mutations in MUM. This study validates their analytical and clinical performance, demonstrating their efficacy in overcoming the limitations of existing ctDNA detection methods.
Exploratory analyses from the phase 2 IMCgp100–10213 and phase 3 IMCgp100–20214 tebentafusp clinical trials have utilized multiplex PCR-based targeted NGS panels for ctDNA detection. These studies demonstrated ctDNA as an early predictive biomarker of tebentafusp efficacy. While targeted NGS is advantageous for detecting a broad range of mutations in heterogeneous tumors, UM is characterized by specific, frequent hotspot mutations, primarily in GNAQ and GNA11 (mutated in ∼85–94% of cases). , This makes UM particularly well-suited for ctDNA detection via ddPCR. In our previous study, as well as in other studies, , different conventional simplex ddPCR assays were employed for ctDNA detection, demonstrating the feasibility and advantages of ddPCR in patients with UM. The conventional workflow requires initial tumor sequencing via targeted NGS to identify somatic mutations, followed by highly sensitive ddPCR-based ctDNA monitoring. While effective, this approach is dependent on NGS, limiting its widespread clinical implementation. Our newly developed multiplex drop-off ddPCR assays address this limitation by enabling a mutation-agnostic approach at the targeted loci, thus making ddPCR-based ctDNA monitoring more accessible and scalable.
Although drop-off ddPCR assays do not allow for precise mutation characterization within driver genes, such detailed information is not essential for tracking ctDNA levels when monitoring the treatment efficacy. Our newly developed multiplex ddPCR assays offer significant advantages over existing methods, including high sensitivity, ease of implementation, cost-effectiveness, rapid turnaround time, and a mutation-agnostic profile (Table ). While they are not designed to detect every rare mutation within these driver genes, they provide broad and robust coverage of the most clinically relevant variants. We therefore propose a stepwise workflow: initially, multiplex 1 is used to identify mutations in tumor DNA. If no mutation is detected, then multiplex 2 is subsequently applied. Finally, if needed, a simplex ddPCR assay targeting GNAQ p.R183 is employed. Once mutations are identified, ctDNA detection in plasma is carried out using the corresponding multiplex ddPCR assay. This streamlined approach maximizes the likelihood of mutation detection and supports efficient ctDNA monitoring. We strongly recommend this workflow as a preferred strategy for routine ctDNA monitoring in patients with metastatic uveal melanoma (MUM). Future challenges for clinical translation include the following: first, standardization of preanalytical conditionsincluding sample collection, processing, and storageis critical to ensure reproducible ctDNA measurements across laboratories; second, regulatory validation is required to demonstrate clinical utility and compliance with relevant guidelines; and finally, prospective studies with larger patient cohorts are needed to confirm the predictive and monitoring capabilities of these assays across diverse treatment settings. Notably, an ongoing clinical trial investigating the efficacy and safety of pembrolizumab in combination with lenvatinib in patients with MUM (PLUME, NCT05282901) incorporates these multiplex ddPCR assays for ctDNA monitoring, providing an opportunity for prospective clinical validation.
2. Advantages and Disadvantages of Different Approaches for ctDNA Detection.
| advantages | disadvantages | |
|---|---|---|
| gene panel NGS | 1. mutation-agnostic approach | 1. takes more time, slow |
| 2. expensive | ||
| 3. necessity of informatics expert support | ||
| simplex ddPCR | 1. easy to use | 1. need to know the target in advance |
| 2. fast | ||
| 3. no need of informatics expert support | ||
| 4. cost-effective | ||
| multiplex drop-off ddPCR | 1. easy to use | 1. does not provide information on the exact nucleotide changes |
| 2. fast | ||
| 3. no need of informatics expert support | ||
| 4. less expensive | ||
| 5. mutation agnostic at the defined loci |
Overall, our study demonstrates that multiplex drop-off ddPCR assays offer a robust and mutation-agnostic approach for ctDNA detection at the targeted loci in MUM. These assays provide a cost-effective and easily implementable alternative to targeted NGS and simplex ddPCR, reducing reliance on NGS while preserving high sensitivity and specificity. Their integration into clinical workflows, including ongoing clinical trials, will further validate their value in personalized patient management and treatment monitoring for the MUM.
Supplementary Material
Acknowledgments
The authors would like to thank Agathe Garcia for her invaluable assistance with patient data.
The clinical data of the patients are not publicly available due to patient privacy. Other data generated in this study are available within the article and its Supporting Information files.
The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.6c00476.
Additional information supporting assay development and validation, including 2D amplitude scatter plots from temperature gradient optimization, representative multiplex drop-off assays, and in vitro performance evaluations with detection efficiency analyses using DNA samples harboring distinct mutations, and primer and probe sequences, as well as quantitative ctDNA detection resultsMAF and copies per mL of plasmaobtained using both simplex and multiplex ddPCR approaches (PDF)
M.H.S and S.R. designed the study. S.R. wrote the manuscript. A.R. performed the ddPCR experiments. A.R. and S.R. analyzed the data. M.R., N.C., A.M., E.J., I.B., and A.V.S. collected the clinical samples and data. S.R.R. secured part of the financial support. F.C.B., M.H.S., M.R., and S.R. reviewed the manuscript. All authors read and approved the final manuscript.
This work was supported by SIRIC 3 Curie (grant SIRIC Curie/INCa-DGOS-Inserm-ITMO Cancer_18000) and funding from Immunocore. MR was supported by an Interface INSERM grant.
Ethics approval and consent to participate: All patients provided written informed consent.
Consent for publication: All participants provided informed consent for the publication. No identifying personal details are disclosed in the manuscript.
The authors declare the following competing financial interest(s): M.R. reports speakers bureau for Immunocore and received research funding from Merck Sharp & Dohme. M-H.S. and S.R. received research support from Immunocore. AM reports speakers fee from Immunocore. The remaining authors declare no competing interests.
References
- Tivey A., Church M., Rothwell D., Dive C., Cook N.. Circulating Tumour DNA - Looking beyond the Blood. Nat. Rev. Clin. Oncol. 2022;19:600–612. doi: 10.1038/s41571-022-00660-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Black J. R. M., Bartha G., Abbott C. W., Boyle S. M., Karasaki T., Li B., Chen R., Harris J., Veeriah S., Colopi M., Bakir M. A., Liu W. K., Lyle J., Navarro F. C. P., Northcott J., Pyke R. M., Hill M. S., Thol K., Huebner A., Bailey C., Colliver E. C., Martínez-Ruiz C., Grigoriadis K., Pawlik P., Moore D. A., Marinelli D., Shutkever O. G., Murphy C., Sivakumar M., TRACERx consortium, Shaw J. A., Hackshaw A., McGranahan N., Jamal-Hanjani M., Frankell A. M., Chen R. O., Swanton C.. Ultrasensitive CtDNA Detection for Preoperative Disease Stratification in Early-Stage Lung Adenocarcinoma. Nat. Med. 2025;31:70–76. doi: 10.1038/s41591-024-03216-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bidard F. C., Hardy-bessard A. C., Dalenc F., Bachelot T., Pierga J. Y., De La Motte Rouge T., Sabatier R., Dubot C., Frenel J. S., Ferrero J. M., Ladoire S., Levy C., Mouret-Reynier M. A., Lortholary A., Grenier J., Chakiba C., Stefani L., Plaza J. E., Clatot F., Teixeira L., D’hondt V., Vegas H., Derbel O., Garnier-Tixidre C., Canon J. L., Pistilli B., André F., Arnould L., Pradines A., Bièche I., Callens C., Lemonnier J., Berger F., Delaloge S.. et al. Switch to Fulvestrant and Palbociclib versus No Switch in Advanced Breast Cancer with Rising ESR1Mutation during Aromatase Inhibitor and Palbociclib Therapy (PADA-1): A Randomised, Open-Label, Multicentre, Phase 3 Trial. Lancet Oncol. 2022;23:1367–1377. doi: 10.1016/s1470-2045(22)00555-1. [DOI] [PubMed] [Google Scholar]
- Jager M. J., Shields C. L., Cebulla C. M., Abdel-Rahman M. H., Grossniklaus H. E., Stern M. H., Carvajal R. D., Belfort R. N., Jia R., Shields J. A., Damato B. E.. Uveal Melanoma. Nat. Rev. Dis. Primers. 2020;6:1–25. doi: 10.1038/s41572-020-0158-0. [DOI] [PubMed] [Google Scholar]
- Khoja L., Atenafu E. G., Suciu S., Leyvraz S., Sato T., Marshall E., Keilholz U., Zimmer L., Patel S. P., Piperno-Neumann S., Piulats J., Kivelä T. T., Pfoehler C., Bhatia S., Huppert P., Van Iersel L. B. J., De Vries I. J. M., Penel N., Vogl T., Cheng T., Fiorentini G., Mouriaux F., Tarhini A., Patel P. M., Carvajal R., Joshua A. M.. Meta-Analysis in Metastatic Uveal Melanoma to Determine Progression Free and Overall Survival Benchmarks: An International Rare Cancers Initiative (IRCI) Ocular Melanoma Study. Ann. Oncol. 2019;30:1370–1380. doi: 10.1093/annonc/mdz176. [DOI] [PubMed] [Google Scholar]
- Fuentes-Rodriguez A., Mitchell A., Guérin S. L., Landreville S.. Recent Advances in Molecular and Genetic Research on Uveal Melanoma. Cells. 2024;13:1–24. doi: 10.3390/cells13121023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Perkins G., Lu H., Garlan F., Taly V.. Droplet-Based Digital PCR: Application in Cancer Research. Adv. Clin. Chem. 2017;79:43–91. doi: 10.1016/bs.acc.2016.10.001. [DOI] [PubMed] [Google Scholar]
- Postel M., Roosen A., Laurent-Puig P., Taly V., Wang-Renault S. F.. Droplet-Based Digital PCR and next Generation Sequencing for Monitoring Circulating Tumor DNA: A Cancer Diagnostic Perspective. Expert Rev. Mol. Diagn. 2018;18:7–17. doi: 10.1080/14737159.2018.1400384. [DOI] [PubMed] [Google Scholar]
- Klouch K. Z., Stern M. H., Trabelsi-Grati O., Kiavue N., Cabel L., Silveira A. B., Hego C., Rampanou A., Popova T., Bataillon G., Nasr S., Proudhon C., Michel M., Renault V., Masliah Planchon J., Vincent-Salomon A., Pierga J. Y., Bieche I., Renault S., Bidard F. C.. Microsatellite Instability Detection in Breast Cancer Using Drop-off Droplet Digital PCR. Oncogene. 2022;41:5289–5297. doi: 10.1038/s41388-022-02504-6. [DOI] [PubMed] [Google Scholar]
- Silveira A. B., Bidard F. C., Kasperek A., Melaabi S., Tanguy M. L., Rodrigues M., Bataillon G., Cabel L., Buecher B., Pierga J. Y., Proudhon C., Stern M. H.. High-Accuracy Determination of Microsatellite Instability Compatible with Liquid Biopsies. Clin. Chem. 2020;66:606–613. doi: 10.1093/clinchem/hvaa013. [DOI] [PubMed] [Google Scholar]
- Mariani P., Bidard F. C., Rampanou A., Houy A., Servois V., Ramtohul T., Pierron G., Chevrier M., Renouf B., Lantz O., Gardrat S., Vincent-Salomon A., Roman-Roman S., Rodrigues M., Piperno-Neumann S., Cassoux N., Stern M. H., Renault S.. Circulating Tumor DNA as a Prognostic Factor in Patients With Resectable Hepatic Metastases of Uveal Melanoma. Ann. Surg. 2023;278:E827–E834. doi: 10.1097/sla.0000000000005822. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rodrigues M., Ramtohul T., Rampanou A., Sandoval J. L., Houy A., Servois V., Mailly-Giacchetti L., Pierron G., Vincent-Salomon A., Cassoux N., Mariani P., Dutriaux C., Pracht M., Ryckewaert T., Kurtz J. E., Roman-Roman S., Piperno-Neumann S., Bidard F. C., Stern M. H., Renault S.. Prospective Assessment of Circulating Tumor DNA in Patients with Metastatic Uveal Melanoma Treated with Tebentafusp. Nat. Commun. 2024;15:1–10. doi: 10.1038/s41467-024-53145-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Carvajal R. D., Butler M. O., Shoushtari A. N., Hassel J. C., Ikeguchi A., Hernandez-Aya L., Nathan P., Hamid O., Piulats J. M., Rioth M., Johnson D. B., Luke J. J., Espinosa E., Leyvraz S., Collins L., Goodall H. M., Ranade K., Holland C., Abdullah S. E., Sacco J. J., Sato T.. Clinical and Molecular Response to Tebentafusp in Previously Treated Patients with Metastatic Uveal Melanoma: A Phase 2 Trial. Nat. Med. 2022;28:2364–2373. doi: 10.1038/s41591-022-02015-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hassel J. C., Piperno-Neumann S., Rutkowski P., Baurain J.-F., Schlaak M., Butler M. O., Sullivan R. J., Dummer R., Kirkwood J. M., Orloff M., Sacco J. J., Ochsenreither S., Joshua A. M., Gastaud L., Curti B., Piulats J. M., Salama A. K. S., Shoushtari A. N., Demidov L., Milhem M., Chmielowski B., Kim K. B., Carvajal R. D., Hamid O., Collins L., Ranade K., Holland C., Pfeiffer C., Nathan P.. Three-Year Overall Survival with Tebentafusp in Metastatic Uveal Melanoma. N. Engl. J. Med. 2023;389:2256–2266. doi: 10.1056/NEJMoa2304753. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Amirouchene-Angelozzi N., Nemati F., Gentien D., Nicolas A., Dumont A., Carita G., Camonis J., Desjardins L., Cassoux N., Piperno-Neumann S., Mariani P., Sastre X., Decaudin D., Roman-Roman S.. Establishment of Novel Cell Lines Recapitulating the Genetic Landscape of Uveal Melanoma and Preclinical Validation of MTOR as a Therapeutic Target. Mol. Oncol. 2014;8:1508–1520. doi: 10.1016/j.molonc.2014.06.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- dMIQE Group, Huggett J. F.. The Digital MIQE Guidelines Update: Minimum Information for Publication of Quantitative Digital PCR Experiments for 2020. Clin. Chem. 2020;66:1012–1029. doi: 10.1093/clinchem/hvaa125. [DOI] [PubMed] [Google Scholar]
- Jeannot E., Darrigues L., Michel M., Stern M. H., Pierga J. Y., Rampanou A., Melaabi S., Benoist C., Bièche I., Vincent-Salomon A., El Ayachy R., Noret A., Epaillard N., Cabel L., Bidard F. C., Proudhon C.. A Single Droplet Digital PCR for ESR1 Activating Mutations Detection in Plasma. Oncogene. 2020;39:2987–2995. doi: 10.1038/s41388-020-1174-y. [DOI] [PubMed] [Google Scholar]
- Zonta E., Garlan F., Pécuchet N., Perez-Toralla K., Caen O., Milbury C., Didelot A., Fabre E., Blons H., Laurent-Puig P., Taly V.. Multiplex Detection of Rare Mutations by Picoliter Droplet Based Digital PCR: Sensitivity and Specificity Considerations. PLoS One. 2016;11:1–20. doi: 10.1371/journal.pone.0159094. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nell R. J., Versluis M., Cats D., Mei H., Verdijk R. M., Kroes W. G. M., Luyten G. P. M., Jager M. J., van der Velden P. A.. Identification of Diagnostic and Prognostic Genetic Alterations in Uveal Melanoma Using RNA Sequencing. Sci. Rep. 2025;15:1–23. doi: 10.1038/s41598-025-90122-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Robertson A. G., Shih J., Yau C., Gibb E. A., Oba J., Mungall K. L., Hess J. M., Uzunangelov V., Walter V., Danilova L., Lichtenberg T. M., Kucherlapati M., Kimes P. K., Tang M., Penson A., Babur O., Akbani R., Bristow C. A., Hoadley K. A., Iype L., Chang M. T., TCGA Research Network, Cherniack A. D., Benz C., Mills G. B., Verhaak R. G. W., Griewank K. G., Felau I., Zenklusen J. C., Gershenwald J. E., Schoenfield L., Lazar A. J., Abdel-Rahman M. H., Roman-Roman S., Stern M. H., Cebulla C. M., Williams M. D., Jager M. J., Coupland S. E., Esmaeli B., Kandoth C., Woodman S. E.. Integrative Analysis Identifies Four Molecular and Clinical Subsets in Uveal Melanoma. Cancer Cell. 2017;32:204–220.e15. doi: 10.1016/j.ccell.2017.07.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Machiraju D., Ziener C. H., Clementi E., García-Asencio F., Hüllein J., Richter J., Lenoir B., Wiecken M., Hübschmann D., Jäger D., Hassel J. C.. Monitoring Soluble CMET and CtDNA in Metastatic Uveal Melanoma Patients to Track Early Disease Progression on Immunotherapies. J. Exp. Clin. Cancer Res. 2025;44:1–16. doi: 10.1186/s13046-025-03451-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bustamante P., Tsering T., Coblentz J., Mastromonaco C., Abdouh M., Fonseca C., Proença R. P., Blanchard N., Dugé C. L., Andujar R. A. S., Youhnovska E., Burnier M. N., Callejo S. A., Burnier J. V.. Circulating Tumor DNA Tracking through Driver Mutations as a Liquid Biopsy-Based Biomarker for Uveal Melanoma. J. Exp. Clin. Cancer Res. 2021;40:1–16. doi: 10.1186/s13046-021-01984-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The clinical data of the patients are not publicly available due to patient privacy. Other data generated in this study are available within the article and its Supporting Information files.




