Skip to main content
Lippincott Open Access logoLink to Lippincott Open Access
. 2026 Jan 19;68(7):577–586. doi: 10.1097/JOM.0000000000003670

Predictors of Serum Per- and Polyfluoroalkyl Substances (PFAS) Levels Among US Career Firefighters

Reagan Conner 1, James Hollister 1, Karen Lutrick 1, Shawn C Beitel 1, Floris C Wardenaar 1, Cynthia Porter 1, Olivia Healy 1, Krystal J Kern 1, John J Gulotta 1, Eric A Valliere 1, Orion J Godfrey, AS 1, Melissa Furlong 1, Jefferey L Burgess 1,✉
PMCID: PMC13290036  PMID: 41556841

Abstract

Objective:

To identify potential predictors of serum concentrations of per- and polyfluoroalkyl substances (PFAS) among a cohort of US firefighters.

Methods:

Serum PFAS concentrations were measured in 2056 US structural firefighters between July 2023 and October 2024. Data on demographics, lifestyle behaviors, occupational exposures, and fire agency policies were collected through individual and fire agency surveys and evaluated for associations with serum PFAS concentrations.

Results:

Plasma and/or blood donation, drinking water source, military service, post-fire on-scene decontamination, turnout gear storage and transportation, rank, using aqueous film-forming foam, and carpet in fire station living quarters were all significant predictors of at least one PFAS chemical (P ≤ 0.05).

Conclusions:

Both individual and departmental predictors of serum PFAS concentrations were identified. These findings can help guide the selection of PFAS exposure reduction activities by firefighters.

Keywords: firefighters, exposure reduction, intervention, turnout gear, drinking water, plasma and blood donation


Serum PFAS concentrations were associated with occupational and non-occupational behaviors, practices, and exposures among over 2000 firefighters, including department policies, gear decontamination practices, drinking water variables, and donating blood or plasma. These findings provide supportive evidence for fire service exposure reduction practices and interventions.


graphic file with name joem-68-0577-g001.jpg


LEARNING OUTCOMES.

  • Readers are able to describe individual-level predictors of serum PFAS concentrations in firefighters.

  • Readers are able to describe fire agency-level predictors of serum PFAS concentrations in firefighters.

Per- and polyfluoroalkyl substances (PFAS) are synthetic substances widely used in industrial and commercial manufacturing due to their strong grease and water repelling properties.1–3 These substances also have a strong resistance to degradation over time and are often referred to as “forever chemicals.” Common products made with PFAS include Class B aqueous film-forming foams (AFFF), packaging materials, cookware, adhesives, and textiles. Use of these products has allowed PFAS to contaminate soil, air, drinking water, and food, and thereby expose humans through routes of ingestion, inhalation, and potentially dermal exposure.1,4 These chemicals accumulate in various human tissues, with the estimated mean half-lives of perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) being 2.7, 3.4, and 5.3 years, respectively.5 Additionally, a study using data from the National Health and Nutrition Examination Survey (NHANES) found that 95% of participants had detectable levels of perfluorononanoic acid (PFNA), PFOS, PFOA, and PFHxS.6 Therefore, the concern with PFAS exposure is not if it is occurring, but rather the extent of exposure, particularly for populations with additional exposure sources such as firefighters.

Exposure to PFAS has been linked to numerous adverse health effects, including but not limited to cardiovascular disease risk, endocrine disruption, accelerated epigenetic aging, widespread alterations to microRNA, and certain cancers.7–12 In November of 2023, the International Agency for Research on Cancer classified PFOA and PFOS as Group 1 and Group 2B carcinogens, respectively.11 Some occupational groups, such as structural and aircraft rescue firefighters, are more exposed to PFAS compared to the general population through use of Class B AFFF and combustible materials.13 A 2022 study comparing serum PFAS levels of structural firefighters in four US fire agencies to NHANES found increased levels of PFHxS, branched isomers of PFOS (Sm-PFOS), linear PFOS (n-PFOS), linear PFOA (n-PFOA), and PFNA in a least two departments.14 Two of these, PFOA and PFOS, were associated with accelerated epigenetic age among a sample of US firefighters.10 Given this information, it is a priority to understand sources and predictors of serum PFAS levels among the fire service.

Increased PFAS exposure among firefighters has been primarily linked to usage of AFFF and inhalation of PFAS-contaminated smoke from burning structural materials.13,15,16 Additionally, as smoke cools, it settles into dust in the area surrounding the fire and on equipment and personal protective gear.16,17 There is also limited evidence to suggest exposure to PFAS from materials used in personal protective gear.18,19 Other factors among firefighters that have been previously associated with increased serum PFAS levels include length of firefighting career (positive), female sex (negative), blood donation (negative), and plasma donation (negative).15,20–24 Predictors of serum PFAS concentrations among firefighters and the general population is still a limited area of research. To provide more information on this topic, we conducted an exploratory analysis of survey data on demographics, lifestyle behaviors, firefighting practices, and self-reported exposures, and serum PFAS concentrations among firefighter participants in the Fire Fighter Cancer Cohort Study (FFCCS).

METHODS

Study Participants

This study included 2056 active career firefighters enrolled in the FFCCS. The FFCCS began enrolling participants in 2016 and is a national 30-year prospective cohort study aimed at understanding and preventing firefighter exposures by collecting survey data and biomarkers. The primary inclusion criterion for enrollment in the FFCCS is active duty as a firefighter. Enrollment into the FFCCS involves an in-person informed consent process, a blood and urine collection, and completion of a comprehensive baseline survey, along with annual survey follow-ups and biological collection approximately every 2 years. Additional details of the FFCCS protocol have been described elsewhere.25 Participants included in these analyses provided a blood specimen between July of 2023 and October of 2024 during FFCCS enrollment or follow-up visits. These participants were active career firefighters employed at a fire service agency in one of seven US states: Arizona, California, Idaho, Massachusetts, Oregon, Virginia, and Washington. All study activities and materials were approved by the University of Arizona Human Subjects Institutional Review Board (IRB) (FWA: 00004218, IRB Number: IRB00000291).

Surveys

The baseline survey gathered information on demographics, general health history and access, lifestyle behaviors, exposures outside of the fire service, occupational exposures, and firefighter career history. Additionally, an agency-level survey was administered to each liaison from participating agencies. These liaisons are employees of their respective fire agencies, often in positions of leadership, who help coordinate between the study team and the study participants in their respective agencies. The agency-level survey aimed to capture information that individual participants may not otherwise know, such as agency policies and resources. All surveys were completed on an electronic device, and responses were recorded in REDCap, an electronic database.26

Biological Specimens (and Laboratory Methods)

Up to 50 mL of blood was collected from each participant. Blood intended for PFAS testing was collected in 10-mL serum tubes and held at room temperature for 30–60 minutes to allow the blood to clot. Blood specimens were maintained at 2°C–8°C on ice packs and transported within 24 hours to the University of Arizona laboratory for processing. Serum tubes were centrifuged at 1300g for 15 minutes, and then serum was aliquoted into polypropylene cryovials and then stored at −80°C until they could be shipped frozen on dry ice to the New Jersey Department of Health for quantification of PFAS. The method referenced for PFAS testing of serum samples was CDC method no. 6304.09. All serum samples were tested for 20 PFAS analytes. These analytes and their limit of detection (LOD) are listed in Supplementary Table 1 (http://links.lww.com/JOM/C370). The individual concentrations of the branched and linear isomers of PFOS and PFOA were quantified, and then the respective isomers were summed to calculate the total PFOS and PFOA concentrations.

Statistical Analyses

To describe our analytic set, we reported the mean and standard deviation (SD) for relevant continuous variables, and frequencies for relevant categorical variables. To assess the relationship between demographics, lifestyle, and occupational variables, and serum PFAS concentration, we fit several regression models for each of the predictors and for each of the eight PFAS analytes in which at least 75% of study participants had a concentration above the LOD. For all models, we natural log-transformed serum PFAS concentration due to the expected right skewness and imputed concentrations below the LOD by the LOD divided by the square root of 2.27 For variables from the individual-level survey, we fit linear regression models adjusted for age, sex at birth, and fire agency, except for variables related to agency characteristics, such as agency drinking water source, which were not adjusted by fire agency. For variables from the agency-level survey, we fit linear mixed models with a random intercept for fire agency, and age, sex at birth, race/ethnicity, and prior military service were included as fixed effects. Then, for all models, we reported the percent change in geometric mean serum PFAS concentration as compared to the reference level for categorical variables, or as compared to a unit change for continuous variables. This percent change is defined as (exp(β^)−1)*100, where β^ represents the coefficient estimated from the regression model. We also reported the 95% confidence intervals (95% CIs) for each percent change, with the null hypothesis equal to a 0% change. For the linear mixed-effect models, we estimated confidence intervals using the Kenward-Roger approach.28

For the four PFAS analytes with 15% to 74% of concentrations above the LOD, we considered fitting logistic regression models, with our outcome being a binary variable indicating above or below the LOD. However, most models failed to converge when including fire agency in the model. Therefore, for the two PFAS analytes in which approximately 70% of individuals had a serum concentration above the LOD, we similarly fit adjusted regression models to the PFAS specified continuously, but we limited these results to the supplemental material as an additional exploratory analysis. The other two PFAS analytes with approximately 20% detection frequencies were excluded. All analyses were conducted using R Statistical Software (v4.4.0).29

RESULTS

Participants were primarily White, non-Hispanic (72%) males (93%), with an average age of 40.4 (SD = 9.0) years (Table 1). The largest percentage of firefighters was from agencies in Arizona (44%), as the study initially focused only on Arizona firefighters before it was later expanded to include the other states. The average number of years served as a career firefighter was 14.2, with the average number of fire responses in the past year being 12. Geometric mean concentrations of eight PFAS analytes (where at least 75% of individuals had concentrations above the LOD) are also displayed, with total PFOS being the highest at 3.55 ng/mL. Full descriptions of PFAS distributions are reported in the supplemental materials (Table S1, http://links.lww.com/JOM/C370)

TABLE 1.

Demographic Information for Predictors of PFAS Analytic Set (N = 2056)

Variable Total (N = 2056)
Department state, n (%)
 Arizona 900 (43.8)
 California 525 (25.5)
 Idaho 140 (6.8)
 Massachusetts 291 (14.2)
 Oregon 28 (1.4)
 Virginia 132 (6.4)
 Washington 40 (1.9)
Sex, n (%)
 Male 1,917 (93.2)
 Female 139 (6.8)
Race/Ethnicity, n (%)
 White, non-Hispanic 1,479 (71.9)
 Hispanic 312 (15.2)
 Black or African American 50 (2.4)
 Other 143 (7.0)
 Missing 72 (3.5)
Age (yr), Mean (SD) 40.4 (9.0)
Number of fires in past year, mean (SD) 11.8 (30.2)
Career firefighting years, mean (SD) 14.2 (9.0)
Serum PFAS concentration (ng/mL),a mean (SD)
 Total PFOS, GM (GSD) 3.55 (1.72)
 Sm-PFOS, GM (GSD) 1.52 (1.80)
 n-PFOS, GM (GSD) 1.99 (1.71)
 Total PFOA, GM (GSD) 1.05 (1.66)
 n-PFOA, GM (GSD) 1.00 (1.64)
 PFHxS, GM (GSD) 1.13 (1.98)
 PFNA, GM (GSD) 0.28 (1.64)
 PFHpS, GM (GSD) 0.10 (2.35)
a

Concentrations below the limit of detection (LOD) imputed by LOD/sqrt(2). See Table S1, http://links.lww.com/JOM/C370, for LOD values and percentage of samples above the LOD.

GM, geometric mean; GSD, geometric standard deviation; n, linear isomer; PFAS, per- and polyfluoroalkyl substances; PFHpS, perfluorodecanoic acid; PFHxS, perfluorohexanesulfonic acid; PFNA, perfluorononanoic acid; PFOS, perfluorooctanesulfonic acid; PFOA, perfluorooctanoic acid; Sm, branched isomers.

Results of adjusted linear regression models of non-occupational variables and serum PFAS concentrations are displayed in Table 2. A significant positive association with age was observed across all eight PFAS analytes. Female sex compared to male sex was significantly associated with lower serum concentrations of all eight PFAS analytes. Compared to White, non-Hispanic ethnicity, Black race was significantly associated with lower serum concentrations of total PFOA and n-PFOA, but higher serum concentrations of n-PFOS, whereas Hispanic ethnicity was significantly associated with lower serum concentrations of total PFOA, n-PFOA, and PFHxS. Compared to firefighters with a BMI <25 kg/m2, firefighters with a BMI ≥30 kg/m2 had significantly lower concentrations of n-PFOS, total PFOA, n-PFOA, and PFHxS. Compared to firefighters not reporting donation of blood or plasma, those donating blood had significantly lower concentrations of Sm-PFOS and PFHpS; those donating blood and plasma had significantly lower concentrations of total PFOS, Sm-PFOS, n-PFOS, PFHxS, PFNA, and PFHpS; and those donating plasma had significantly lower concentrations of all eight PFAS analytes except PFNA. Compared to firefighters with a municipal water system for their home drinking water, those primarily drinking bottled water had significantly lower concentrations of total PFOA, n-PFOA, and PFNA. Those primarily drinking well water, compared to those with a municipal water system, had significantly higher concentrations of total PFOS, Sm-PFOS, n-PFOS, PFNA, and PFHpS. Also compared to those with a municipal water system, those primarily drinking other sources, such as pitcher water filters, had significantly lower concentrations of n-PFOS, and PFNA. Eating pizza more frequently, compared to 0 times in 3 months, was associated with significantly lower concentrations of multiple PFAS types (1–3 times per month: total PFOS, n-PFOS, total PFOA, n-PFOA, and PFHxS; 1 or more times per week: n-PFOS, total PFOA, n-PFOA, PFHxS, and PFNA). Similarly, eating fast food more frequently, compared to 0 times in 3 months, was significantly associated with lower concentrations of some PFAS types (1–3 times per month: total PFOA and n-PFOA; 1 or more times per week: total PFOA, n-PFOA, and PFNA). Smoke exposure at home was significantly associated with lower concentrations of total PFOA, n-PFOA, and PFHxS. However, smoking at least 100 cigarettes in their lifetime and living near an airport were not significantly associated with any PFAS analytes. Similarly, eating microwave popcorn, eating food from paper packaging, drinking filtered water at home, and having reverse osmosis filtered water at home were not significantly associated with any PFAS analyte.

TABLE 2.

Non-occupational Associations With Serum PFAS Concentrations (Percent Change and 95% Confidence Intervals) in Firefighters (N = 2056)

Variable Total PFOS Sm-PFOS n-PFOS Total PFOA n-PFOA PFHxS PFNA PFHpS
Age (yr) 19 (16, 21)* 22 (19–25)* 16 (13–19)* 5 (3–8)* 5 (3–8)* 8 (5–11)* 10 (7–12)* 26 (21–30)*
Sex (reference: male, n = 1,917)
 Female (n = 139) −47 (−51, −42)* −53 (−57, −49)* −42 (−47, −37)* −21 (−27, −14)* −21 (−27, −14)* −56 (−60, −51)* −22 (−28, −15)* −73 (−76, −69)*
Race/ethnicity (reference: NH White, n = 1477)
 Black or Afr. Am. (n = 50) 14 (0, 32) 6 (−8, 23) 21 (5, 39)* −14 (−24, −1)* −14 (−24, −1)* −10 (−25, 8) 14 (0, 30) −7 (−25, 15)
 Hispanic (n = 311) −4 (−10, 2) −3 (−9, 3) −4 (−10, 2) −6 (−12, −1)* −6 (−12, −1)* −11 (−18, −4)* −2 (−7, 4) −8 (−16, 0)
 Other (n = 143) 2 (−6, 11) −2 (−10, 8) 4 (−4, 14) 5 (−3, 14) 5 (−3, 14) 0 (−10, 12) 9 (1, 18)* 3 (−10, 17)
BMI (kg/m2) (reference: underweight/normal <25.0, n = 349)
 Overweight 25.0–29.9 (n = 1,117) 0 (−6, 7) 2 (−4, 9) −1 (−7, 5) −5 (−11, 0) −5 (−11, 0) 0 (−8, 8) −3 (−8, 3) 4 (−5, 14)
 Obese ≥30 (n = 484) −6 (−12, 1) −3 (−9, 5) −8 (−15, −2)* −10 (−16, −4)* −10 (−16, −4)* −11 (−19, −3)* −5 (−11, 1) −4 (−13, 7)
History of blood/plasma donation (reference: never donated blood or plasma, n = 613)
 Yes, blood (n = 886) −5 (−10, 0) −6 (−11, −1)* −4 (−9, 1) −1 (−6, 4) −1 (−6, 4) −6 (−12, 0) −4 (−9, 0) −10 (−16, −3)*
 Yes, blood and plasma (n = 271) −10 (−16, −3)* −11 (−17, −4)* −8 (−14, −1)* −4 (−10, 3) −4 (−10, 3) −13 (−20, −4)* −9 (−15, −3)* −15 (−24, −6)*
 Yes, plasma (n = 35) −22 (−35, −8)* −31 (−43, −17)* −17 (−30, −1)* −17 (−29, −2)* −17 (−29, −2)* −32 (−46, −16)* −9 (−23, 7) −40 (−54, −23)*
Smoked 100 cigarettes (reference: no, n = 1,641)
 Yes (n = 303) −5 (−10, 1) −5 (−11, 2) −5 (−10, 2) 5 (−1, 11) 5 (−1, 11) 3 (−5, 11) 3 (−3, 9) −4 (−12, 6)
Smoke exposure at home (reference: no, n = 1,964)
 Yes (n = 31) −9 (−23, 8) −13 (−27, 5) −7 (−22, 11) −22 (−34, −8)* −22 (−34, −8)* −23 (−39, −4)* −10 (−24, 6) −22 (−40, 1)
Live near airport (reference: no, n = 1,580)
 Yes (n = 364) 1 (−4, 7) 2 (−4, 9) 1 (−5, 7) −2 (−7, 3) −2 (−7, 3) 1 (−6, 9) −1 (−6, 5) −1 (−9, 8)
Eats pizza (reference: 0 times in 3 mo, n = 290)
 1–3 times per month (n = 1,282) −7 (−13, −1)* −4 (−10, 3) −9 (−15, −3)* −7 (−12, −1)* −7 (−12, −1)* −12 (−19, −5)* −5 (−10, 1) −6 (−14, 3)
 ≥1 time/week (n = 175) −9 (−17, 0) −4 (−13, 7) −13 (−21, −4)* −10 (−18, −2)* −10 (−18, −2)* −14 (−24, −3)* −13 (−20, −5)* −10 (−22, 3)
Eats fast food (reference: 0 times in 3 mo, n = 141)
 1–3 times per month (n = 1,059) −1 (−10, 8) 1 (−8, 11) −3 (−11, 6) −11 (−18, −3)* −11 (−18, −3)* −6 (−16, 5) −7 (−15, 0) −2 (−14, 11)
 ≥1 time/week (n = 562) 0 (−9, 10) 4 (−6, 15) −3 (−12, 7) −11 (−19, −3)* −11 (−19, −3)* −5 (−16, 7) −9 (−17, −1)* 3 (−11, 18)
Eats popcorn (reference: 0 times in 3 mo, n = 1,199)
 1–3 times per month (n = 467) 3 (−2, 9) 6 (0, 12) 2 (−4, 7) 1 (−4, 7) 1 (−4, 7) 4 (−3, 12) 2 (−3, 7) 4 (−4, 12)
 ≥1 time/week (n = 76) −3 (−14, 9) −1 (−13, 12) −6 (−16, 6) 0 (−11, 11) 0 (−11, 11) −11 (−23, 4) −3 (−13, 8) −11 (−25, 6)
Food in paper package (reference: 0 times in 3 mo, n = 554)
 1–3 times per month (n = 870) −1 (−6, 4) 2 (−4, 8) −4 (−9, 2) 1 (−4, 7) 1 (−4, 7) −1 (−7, 6) −4 (−8, 1) 0 (−8, 8)
 ≥1 time/week (n = 309) −3 (−10, 4) 1 (−6, 9) −7 (−13, 0) 2 (−5, 9) 2 (−5, 9) −5 (−13, 4) −6 (−12, 1) −1 (−11, 10)
Home filtered drinking water (reference: No, n = 297)
 Yes (n = 1,267) −3 (−9, 3) −4 (−10, 3) −3 (−9, 4) −5 (−11, 1) −5 (−11, 1) −3 (−11, 5) −4 (−9, 2) −6 (−15, 3)
Home reverse osmosis (reference: no, n = 1,154)
 Yes (n = 353) 0 (−6, 6) −1 (−7, 6) 0 (−6, 7) −3 (−9, 3) −3 (−9, 3) −6 (−13, 2) 1 (−4, 7) −4 (−12, 5)
Home drinking water source (reference: municipal/public water supply, n = 986)
 Bottled (n = 355) −5 (−11, 1) −4 (−11, 2) −5 (−11, 1) −8 (−13, −2)* −8 (−13, −2)* −6 (−13, 2) −9 (−14, −3)* −7 (−16, 2)
 Other (n = 97) −10 (−19, 0) −8 (−17, 3) −11 (−20, −1)* −3 (−12, 7) −3 (−12, 7) −3 (−15, 11) −11 (−19, −2)* −7 (−20, 9)
 Well (n = 124) 19 (8, 31)* 12 (1, 25)* 24 (12, 37)* 3 (−6, 13) 3 (−6, 13) 2 (−10, 16) 17 (7, 28)* 19 (3, 37)*

Age and sex models adjusted for fire agency. Age is represented in units of 10 years. All other models adjusted for age, sex, and fire agency, unless otherwise noted. All predictor variables are aggregate results from the individual participant survey responses.

*

Statistically significant at alpha = 0.05.

Displayed in Table 3 are the results of linear regression models of occupational variables (measured by the individual baseline survey) and serum PFAS concentrations. Career firefighter years of service was positively associated with all PFAS analytes, except for PFOA. Individuals with previous or active military service had significantly higher concentrations of total PFOS, n-PFOS, and PFHxS, compared to individuals with no military service. For rank/role, compared to firefighters, captains and driver/operators had significantly higher concentrations of total PFOS, Sm-PFOS, n-PFOS, PFHxS, and PFHpS. Current use of AFFF was positively associated with total PFOA and n-PFOA, compared to no use of AFFF in the past 5 years. Significantly lower concentrations of all eight PFAS analytes were associated with drinking primarily bottled water at the station, compared to drinking primarily tap water. Additionally, drinking primarily “other” sources of water at the station, such as pitcher-style water filters, was significantly associated with lower concentrations of all PFAS analytes, except total PFOA and n-PFOA.

TABLE 3.

Occupational Associations With Serum PFAS Concentrations in Firefighters (Percent Change and 95% Confidence Intervals), Individual Survey Responses (N = 2056)

Variable Total PFOS Sm-PFOS n-PFOS Total PFOA n-PFOA PFHxS PFNA PFHpS
Age, yr 19 (16, 21)* 22 (19, 25)* 16 (13, 19)* 5 (3, 8)* 5 (3, 8)* 8 (5, 11)* 10 (7, 12)* 26 (21, 30)*
Career firefighter (FF) years 9 (4, 15)* 7 (2, 12)* 11 (6, 16)* 0 (−4, 4) 0 (−4, 4) 8 (2, 15)* 5 (1, 10)* 14 (6, 22)*
Sex (reference: male, n = 1,917)
 Female (n = 139) −47 (−51, −42)* −53 (−57, −49)* −42 (−47, −37)* −21 (−27, −14)* −21 (−27, −14)* −56 (−60, −51)* −22 (−28, −15)* −73 (−76, −69)*
Military service (reference: no, n = 1,512)
 Yes (n = 401) 8 (2, 16)* 6 (−1, 13) 11 (4, 18)* 2 (−4, 9) 2 (−4, 9) 21 (11, 32)* −2 (−8, 4) 9 (−1, 20)
Current rank (reference: FF, n = 396)
 Battalion/deputy chief (n = 111) 10 (−1, 23) 10 (−2, 24) 10 (−2, 23) 7 (−4, 19) 7 (−4, 19) 14 (−2, 31) 2 (−8, 13) 17 (−2, 38)
 Captain (n = 488) 10 (2, 18)* 9 (1, 18)* 10 (2, 18)* 6 (−1, 14) 6 (−1, 14) 13 (3, 25)* 4 (−3, 11) 14 (1, 27)*
 Driver operator (n = 316) 12 (3, 21)* 11 (2, 21)* 11 (3, 21)* 6 (−1, 15) 6 (−1, 15) 15 (4, 28)* 7 (−1, 15) 18 (5, 33)*
 FF/paramedic/EMT (n = 499) 3 (−4, 10) 4 (−3, 12) 2 (−5, 9) 6 (−1, 13) 6 (−1, 13) 5 (−4, 15) 2 (−4, 9) 1 (−9, 11)
 Other (n = 185) 1 (−8, 10) 0 (−9, 10) 1 (−8, 10) 8 (−1, 17) 8 (−1, 17) 0 (−11, 12) 1 (−8, 9) −3 (−15, 11)
Times donned gear (past year) (reference: 0–10, n = 192)
 11 to 250 (n = 1195) 8 (0, 17) 7 (−1, 17) 8 (0, 17) 2 (−5, 10) 2 (−5, 10) 9 (−2, 20) 3 (−4, 11) 7 (−5, 20)
 >250 (n = 387) 9 (−1, 20) 11 (0, 22) 8 (−2, 19) 7 (−2, 17) 7 (−2, 17) 10 (−2, 24) 2 (−6, 12) 9 (−5, 26)
No. of fires with gear (past year)
 No. fires (continuous) 0 (−2, 2) 0 (−3, 2) 0 (−2, 3) 0 (−2, 2) 0 (−2, 2) 0 (−3, 2) 1 (0, 3) 0 (−3, 3)
Second set of gear (reference: yes, n = 1,584)
 No (n = 190) −11 (−20, −1)* −11 (−21, −1)* −11 (−20, −1)* −4 (−13, 6) −4 (−13, 6) −2 (−14, 13) −4 (−13, 6) −17 (−29, −3)*
On-scene decontamination (reference: none of the above, n = 194)
 Dry brush only (n = 47) 19 (2, 39)* 19 (1, 40)* 19 (1, 39)* 2 (−13, 18) 2 (−13, 18) 21 (−1, 48) 6 (−9, 22) 13 (−10, 43)
 Other (n = 18) −2 (−23, 24) −4 (−25, 24) −2 (−23, 25) −24 (−40, −5)* −24 (−40, −5)* −5 (−30, 28) 12 (−11, 40) −3 (−32, 38)
 Rinse only (n = 588) 1 (−8, 10) −1 (−9, 9) 1 (−8, 10) −11 (−18, −3)* −11 (−18, −3)* −10 (−20, 0) 3 (−5, 12) −4 (−16, 9)
 Soap/brush/rinse (n = 846) 0 (−8, 9) −1 (−9, 9) 0 (−8, 9) −9 (−16, −1)* −9 (−16, −1)* −10 (−20, 0) 2 (−6, 11) −6 (−18, 6)
AFFF use (any use in past 5 yr) (reference: no, n = 288)
 Past 5 yr, not currently (n = 637) 1 (−7, 9) 2 (−6, 10) 0 (−7, 8) 5 (−3, 13) 5 (−3, 13) 6 (−3, 17) 2 (−5, 10) 6 (−5, 19)
 Currently use/have AFFF (n = 262) 5 (−4, 15) 4 (−6, 14) 6 (−3, 16) 11 (2, 21)* 11 (2, 21)* 11 (0, 25) 5 (−4, 15) 10 (−4, 26)
Agency hood swap/weekly clean programa (reference: no, n = 1,040)
 Yes (n = 1006) 3 (−1, 7) 4 (−1, 9) 2 (−2, 7) −8 (−12, −4)* −8 (−12, −4)* 6 (0, 12) −3 (−7, 1) 10 (3, 17)*
Agency drinking water sourcea (reference: tap water, n = 638)
 Bottled (n = 606) −14 (−19, −9)* −13 (−18, −8)* −14 (−19, −9)* −11 (−16, −6)* −11 (−16, −6)* −21 (−27, −15)* −11 (−16, −6)* −15 (−22, −8)*
 Other (n = 291) −11 (−17, −5)* −8 (−15, −1)* −13 (−19, −7)* −4 (−10, 3) −4 (−10, 3) −13 (−20, −5)* −15 (−20, −9)* −16 (−24, −7)*

All age and sex models adjusted for fire agency. Age is represented in units of 10 years. All other models adjusted for age, sex, and fire department, unless otherwise noted.

a

Variable not adjusted for fire department.

*

Statistically significant at alpha = 0.05.

Compared to firefighters who reported not performing on-scene decontamination, also known as on-scene washdown, those who reported using soap/brush/rinse, rinse only, or another method had significantly lower concentrations of total PFOA and n-PFOA. Firefighters who reported participating in an agency hood swap or weekly clean program had significantly lower concentrations of total PFOA and n-PFOA, but significantly higher concentrations of PFHpS. Compared to firefighters who reported having two sets of gear to rotate between, those with only one set of gear had significantly lower concentrations of total PFOS, Sm-PFOS, n-PFOS, and PFHpS. Lastly, number of fires with turnout gear in the past year and times donned turnout gear in the past year were not significantly associated with any PFAS analytes.

The geometric mean ratios describing percent change with variables from the agency-level predictor hierarchical models are displayed in Table 4. An agency policy requiring firefighters to wash gear prior to storing it and having an automatic closing door for the room designated for turnout gear storage were significantly associated with lower concentrations of total PFOA, compared to agencies without this policy. An agency policy to decontaminate the interior of fire apparatuses was significantly associated with lower concentrations of PFHpS compared to those without this agency policy. At agencies where all employees are supplied with a gear bag, we observed significantly lower concentrations of total PFOA and n-PFOA. A similar association was observed for agencies where station living quarters are dusted at least once per week compared to monthly or never. Dusting of station living quarters at least weekly was significantly associated with lower concentrations of total PFOA and n-PFOA. Having reverse osmosis filters in fire stations was associated with significantly lower concentrations of PFNA.

TABLE 4.

Associations of Agency-Level Variables With Serum PFAS Concentrations (Percent Changes and 95% Confidence Intervals)

Variable Agency N (Individual N) Total PFOS Sm-PFOS n-PFOS Total PFOA n-PFOA PFHxS PFNA PFHpS
Automatic door: Does the room designated for turnout gear storage have an automatic closing door? (reference: no, n = 12 [1280])
 Yes 21 (698) 1.7 (−8.1, 12.6) −0.9 (−11.6, 11.0) 3.7 (−7.0, 15.6) −13.0 (−23.7, −0.8)* −11.5 (−21.9, 0.4) 12.3 (−5.9, 34.0) −9.4 (−19.9, 2.5) −0.9 (−17.6, 19.0)
Carpet: Do any of your stations have carpet flooring in any part of the living quarters? (reference: no, n = 15 [732])
 Yes 18 (1246) 8.9 (−1.2, 19.9) 7.5 (−3.7, 19.9) 9.9 (−1.0, 21.9) 7.7 (−5.9, 23.3) 6.7 (−6.2, 21.3) 1.1 (−15.6, 21.1) 8.7 (−3.8, 22.9) 24.0 (5.4, 45.9)*
Dust frequency: How frequently are stations instructed to Dust INSIDE living quarters? If policies vary by station, please indicate the frequency that is most common among most stations. (n = 1 [17] were missing and excluded; reference: monthly or never, n = 15 [1,020])
 ≥1×/week 13 (745) 3.7 (−7.3, 16.0) 3.0 (−9.1, 16.7) 4.7 (−7.2, 18.1) −14.2 (−25.6, −1.1)* −12.9 (−24.0, −0.2)* 14.0 (−6.3, 38.6) −8.1 (−19.6, 5.1) 9.8 (−8.0, 31.0)
 Every 2 wk 4 (187) 6.1 (−9.7, 24.8) 5.8 (−11.7, 26.8) 7.2 (−10.0, 27.6) −3.6 (−21.7, 18.6) −0.8 (−18.7, 20.9) −1.0 (−25.5, 31.7) 3.2 (−19.6, 5.1) 45.9 (13.1, 88.2)*
Turnout wash policy: Does your department have a policy requiring turnout gear to be washed prior to storing it? (reference: no, n = 8 [776])
 Yes 25 (1202) 5.9 (−5.4, 18.5) 6.2 (−6.3, 20.4) 5.2 (−7.0, 19.0) −15.7 (−26.9, −2.7)* −11.9 (−23.5, 1.5) −3.5 (−21.6, 18.8) −7.3 (−19.6, 6.8) −6.0 (−23.6, 15.6)
Marked zones: Does your department have marked zones in each station to indicate the levels of contamination (eg, red = highly contaminated, yellow = contaminated/transition zone, green = safe)? (reference: no, n = 25 [1415])
 Yes 8 (563) 4.4 (−6.6, 16.6) 4.3 (−7.8, 18.1) 4.5 (−7.3, 17.8) −1.2 (−15.5, 15.6) 0.2 (−13.6, 16.3) 21.7 (0.9, 46.7)* −4.5 (−17.1, 10.1) 3.8 (−15.3, 27.1)
NFPA gear requirement: Please select the option that best describes your department's compliance with the NFPA 1851 requirement for advanced cleaning and inspection (reference: >2 annual cleanings, n = 8 [758])
 <2 annual cleanings 14 (607) −0.5 (−12.0, 12.6) −6.7 (−18.6, 6.9) 4.4 (−8.5, 19.0) 11.2 (−6.0, 31.5) 8.5 (−7.6, 27.4) −7.4 (−25.9, 15.8) 8.8 (−6.8, 27.0) −1.4 (−21.3, 23.5)
 2 annual cleanings 11 (613) −4.2 (−16.0, 9.2) −6.6 (−19.2, 8.0) −2.1 (−14.9, 12.6) 5.4 (−11.8, 26.0) 6.0 (−10.6, 25.7) −11.1 (−29.9, 12.6) 3.3 (−12.4, 21.7) −2.1 (−23.0, 24.4)
Gear bag policy: Does your department supply a gear bag for employees for transporting gear? (reference: no, n = 4 [398]; n = 1 [3] were missing and excluded)
 Yes 28 (1577) −6.0 (−18.7, 8.7) −3.2 (−17.8, 14.0) −8.5 (−21.7, 7.0) −26.1 (−37.7, −12.3)* −20.1 (−33.0, −4.7)* −15.7 (−34.9, 9.1) −9.7 (−24.8, 8.5) −14.4 (−34.1, 11.1)
Decontaminate policy: Does your department have a policy for decontaminating fire apparatus interior after fires? (reference: no, n = 19 [1,119])
 Yes 14 (859) 5.7 (−4.3, 16.8) 7.1 (−4.1, 19.6) 4.9 (−5.8, 16.9) −5.0 (−17.1, 8.9) −3.0 (−14.9, 10.5) 12.5 (−5.7, 34.1) −7.4 (−18.1, 4.6) −16.2 (−29.4, −0.5)*
Reverse osmosis: Do any of your department's fire stations use a reverse osmosis water filtration system? (reference: no, n = 13 [803]; n = 3 [262] were missing and excluded)
 Yes 17 (781) −2.3 (−12.2, 8.7) 0.8 (−10.5, 13.4) −4.8 (−15.2, 7.0) −11.3 (−22.3, 1.2) −9.2 (−19.6, 2.7) −2.6 (−17.7, 15.3) −11.2 (−21.0, −0.2)* 0.2 (−18.0, 22.3)
Primary gear locker: Do firefighters store their primary set of turnout gear in a personal locker at the station? (reference: no, n = 5 [136])
 Yes 28 (1842) −3.4 (−17.1, 12.7) 0.3 (−15.4, 18.9) −6.2 (−20.4, 10.5) 9.1 (−10.8, 33.6) 9.6 (−9.5, 32.8) −11.5 (−31.9, 15.0) 0.0 (−17.1, 20.6) 2.1 (−22.1, 33.9)
Ventilation: Does the room designated for turnout gear storage have its own ventilation system (separate from the rest of the station)? (reference: no, n = 16 [1,066])
 Yes 17 (912) 2.4 (−7.4, 13.3) 4.9 (−6.1, 17.2) 0.7 (−9.7, 12.3) −11.9 (−22.4, 0.0) −11.0 (−21.1, 0.4) 15.0 (−3.5, 37.1) −6.9 (−17.6, 5.1) 2.2 (−14.6, 22.4)
HEPA air filters: Are HEPA air filters installed in any of your fire stations? (reference: no, n = 18 [1,418])
 Yes 15 (560) −3.2 (−12.6, 7.3) −2.6 (−13.1, 9.0) −3.8 (−13.8, 7.4) −10.5 (−21.5, 2.1) −9.2 (−20.0, 2.9) −2.5 (−18.6, 16.7) −10.9 (−20.9, 0.2) −8.2 (−23.3, 9.9)
Doff requirement: Does your department require members to doff all firefighter gear prior to getting back on apparatus when returning to quarters after a fire? (reference: no, n = 8 [869])
 Yes 25 (1,109) 2.9 (−8.2, 15.3) 5.3 (−7.1, 19.4) 1.1 (−10.7, 14.5) −8.4 (−21.6, 7.0) −10.0 (−22.2, 4.0) 6.5 (−13.1, 30.7) −14.6 (−25.1, −2.5) −0.1 (−18.8, 22.8)
Extraction location: Does your department have extraction washer(s) available at each station or at a centralized location? (reference: at a centralized station, n = 16 [1,056])
 At each station 17 (922) 6.5 (−3.6, 17.6) 10.4 (−0.9, 22.9) 3.9 (−6.8, 15.8) 2.5 (−10.7, 17.6) 5.2 (−7.6, 19.8) 13.6 (−4.4, 35.1) −1.3 (−13.0, 11.9) −12.8 (−26.7, 3.8)
Gear drying: After rinsing or washing turnout gear, how is the turnout gear dried? (reference: air dry, n = 19 [776]; n = 3 [210] were missing/excluded)
 Turnout dryer 11 (992) −2.0 (−12.1, 9.2) −1.7 (−13.0, 11.1) −2.0 (−12.7, 10.0) 2.2 (−11.6, 18.2) 5.6 (−7.8, 21.0) −11.6 (−26.2, 5.9) 3.7 (−8.6, 17.6) 2.0 (−16.1, 23.9)
Contamination policy: Does your department have a policy forbidding members to take contaminated clothes and/or PPE home, or store them in a personal vehicle? (reference: no, n = 15 [878])
 Yes 18 (1,100) 4.9 (−5.1, 15.9) 6.5 (−4.6, 18.8) 3.3 (−7.3, 15.2) −2.0 (−14.6, 12.6) 0.1 (−12.2, 14.2) 19.5 (0.8, 41.6) 0.6 (−11.4, 14.2) −15.4 (−28.9, 0.7)
Decontaminate kit: Does every piece of apparatus and every fire department structure, including training facilities, have a gross decontamination kit with body wipes and a stiff brush for turnout gear? (reference: no, n = 10 [664])
 Yes 23 (1314) 9.2 (−2.1, 21.8) 10.6 (−2.0, 24.9) 8.3 (−3.8, 21.9) −11.4 (−23.4, 2.3) −8.2 (−20.2, 5.7) 8.2 (−11.2, 31.8) −9.6 (−21.0, 3.3) 9.1 (−10.7, 33.2)

Results represent change in serum PFAS concentrations, with estimates from a linear mixed model with a random intercept for fire department. Confidence intervals calculated using a Kenward-Roger approximation. All models include age, sex, race/ethnicity, and prior military service.

Although lower concentrations were observed for weekly dusting of station living quarters, we found that dusting every 2 weeks was associated with significantly higher concentrations of PFHpS. Carpet in station living quarters was also significantly associated with higher concentrations of PFHpS. Among agencies where stations have marked zones to indicate levels of contamination, significantly higher concentrations of PFHxS were observed. Agency-level variables that were not significantly associated with any PFAS analytes include those related to turnout gear storage location, air filtration, doffing contaminated turnout gear, having gross decontamination kits on each apparatus, extractor location, adherence to NFPA 1851 for advanced cleaning of turnout gear, and method of drying turnout gear (Table 4).

Lastly, the results of the exploratory analysis with adjusted regression models for the two PFAS analytes in which 25% to 74% of individuals had a serum concentration above the LOD (PFDA and PFUnA) are reported in supplementary tables. The non-occupational predictors with significant associations with PFDA and/or PFUnA include age (positive), female sex (negative), race (Black or African American and Other, negative), history of blood and plasma donation (negative), living near an airport (negative), eating pizza more frequently (negative), eating fast food more frequently (negative), eating food from a paper package more frequently (negative), and home drinking water source (bottled and other: negative PFDA; well: positive association with PFDA and PFUnA). Occupational predictors significantly associated with PFDA and/or PFUnA include career firefighter years (positive), rank (captains and driver/operators: positive), and gear bag policy (negative association with PFUnA). The geometric mean ratios and confidence intervals are included in the supplementary material (Supplementary Table 2A-C, http://links.lww.com/JOM/C371).

DISCUSSION

In our firefighter population, serum PFAS measured above the LOD in 75% or more of the study participants included total PFOS, Sm-PFOS, n-PFOS, total PFOA, n-PFOA, PFHxS, PFNA, and PFHpS, whereas PFUnA was detected in 74% and PFDA 25% of individuals tested. We observed significant positive and negative associations between these serum PFAS concentrations in firefighters and both non-occupational and occupational predictors, findings that support potential workplace and personal interventions to reduce PFAS exposure.

Positive Associations With Serum PFAS Concentrations

Black/African American race, age, career firefighter years, captain and engineer firefighter rank, military service, AFFF use, and drinking well water were positively associated with at least one PFAS analyte in the primary analysis. Higher n-PFOS concentrations were observed among Black/African American firefighters, but this may be explained by similar findings of exposure disparities of n-PFOS among Black/African American individuals in a previous study.30 Similar to the general population, age was highly correlated with higher concentrations of all eight PFAS analytes among firefighters in our study.31 Consistent with our findings, a positive association between years as a firefighter and serum PFOS and PFHxS has been reported, and unadjusted models in another study revealed an association with PFNA.15,20 Higher concentrations of PFHpS associated with years as a firefighter were also observed, but may be a reflection of the positive temporal association seen in the general population.32 To our knowledge, our study is the first to find significantly different PFAS concentrations by rank. Our findings of higher PFAS concentrations among captains and engineers compared to firefighters may be explained by increased years of service with higher rank. A previous study identifying greater increases in urinary post-fire polycyclic aromatic hydrocarbons (PAH) metabolites in firefighters compared with engineers and captains suggests that differences in acute fireground exposures by rank are not a likely explanation for our findings.33

A major contributor to serum PFAS concentrations is contaminated drinking water.34 In our results, bottled water and reverse osmosis (at stations) were negatively associated with some serum PFAS concentrations, whereas well water was positively associated with some serum PFAS concentrations. Our bottled water findings are consistent with studies summarized in a recent review showing lower average PFAS (PFOS, PFOA, PFHxS, and PFDA) in bottled water compared to tap water.35 We also observed significantly lower concentrations of PFNA associated with reverse osmosis filtration systems being installed at fire stations, which would be expected if some of the fire station untreated drinking water sources were contaminated with PFAS, as reverse osmosis is effective in removing long-chain PFAS chemicals.36,37 There are limited data on concentrations of PFAS in well water; however, those previous studies found that PFAS concentrations measured in private well water were comparable to concentrations in the local public water supply.38,39 Thirteen percent of the US population relies on private well water, but it is not frequently tested as the burden of maintenance and hygiene is placed on the individual owners.40,41 This could mean that individuals who rely on well water could have increased PFAS exposure because they may not know if their water is contaminated or know of ways to remove PFAS chemicals.

We observed a positive association between military service and PFOS and PFHxS concentrations. This may be a direct result of AFFF use, or indirect AFFF exposure while in the military such as consumption of contaminated drinking water.13,42 Consistent findings across other studies have linked AFFF use with increased PFAS concentrations.15,21,43 Unexpectedly, current AFFF use as a firefighter was not significantly associated with PFOS or PFHxS, but instead with PFOA. Ansulite AFFF, a common fluorinated Class B foam choice for firefighting, has fluorotelomer sulfonic acids, which can potentially degrade to PFOA.22 As many departments are transitioning toward fluorine-free foams, they may still have the fluorinated foam, such as Ansulite, at their stations, which is degrading while awaiting disposal. However, this may also be a result of contaminated drinking water.34

Our findings also revealed that carpet in station living quarters was associated with higher serum concentrations of PFHpS. In a study measuring PFAS concentrations in consumer products and building materials, the highest concentrations of a mixture of perfluoroalkyl acids (PFAAs) were detected in textiles.44 However, more information is required in our study to conclude whether carpet is the source of PFHpS or if it holds contamination from other sources. This appears inconsistent with the findings of another study, which did not find a significant association with percentage of carpet in fire station living quarters and PFAS concentrations measured in fire station dust.45

Negative Associations With Serum PFAS Concentrations

Hispanic ethnicity and Black/African American race, female sex, and history of blood and plasma donation were some of the non-occupational variables associated with lower concentrations of at least one PFAS analyte. We observed lower PFOA and PFHxS concentrations among Hispanic individuals compared to White, non-Hispanic individuals, similar to trends from the National Health and Nutrition Examination Survey (NHANES). Unlike our findings showing lower PFOA concentrations among Hispanic and Black/African American individuals, no significant association was observed among these NHANES groups.46 Our results revealed that female sex was associated with significantly lower concentrations of all eight PFAS analytes, similar to previous studies of the general population46–48 and a previous study of firefighters,49 with the exception of PFHpS, which was not found in previous studies to be significantly lower in women in the general population or the fire service.31,46–49 Lower serum PFAS concentrations among females is likely the result of menstrual blood loss,47,48 which strengthens our findings related to blood and plasma donation. A key finding of our study is the significant association between lower concentrations of multiple PFAS analytes and a history of donating blood and/or plasma, with plasma donation showing an association with a greater reduction in PFAS compared to a history of not donating blood or plasma. This finding aligns with the results of a previous randomized-controlled trial among Australian firefighters.24 For-profit plasma donation centers send their product to fractionators, where the separation and purification process includes ethanol washes and pH changes,50 which likely remove some of the PFAS bound to the protein, as PFAS-protein binding capacity is disrupted by pH changes51,52 and in the presence of solvents.53 These steps are followed by pore-based filtration, which likely removes additional PFAS. Although not formally tested, the purification process may mitigate some of the ethical concerns about PFAS exposure to plasma product recipients. Additionally, destruction of the plasma product with high PFAS loads has also been proposed.

Performing on-scene decontamination, having an agency policy to wash gear prior to storing it, having a gear bag, having agency hood swap/weekly clean programs, having an agency policy to decontaminate the fire apparatus, and dusting in the stations were some of the occupational variables associated with lower concentrations of at least one PFAS analyte. A significant finding of our study is the association between lower PFOA concentrations and on-scene decontamination (rinse only and soap/brush/rinse). This may be supported with findings from a previous study among responders to the World Trade Center disaster on September 11, 2001, which measured higher concentrations of PFOA, PFNA, and PFHxS related to significant smoke and dust exposure.16 Additionally, a study of decontamination procedures found that the soap/brush/rinse method was the most effective for reducing PAHs,54 and another study found that the rinse only method was not effective in reducing PAHs.55 Furthermore, our previous study of on-scene decontamination found a significant 36.2% reduction in post-fire urinary PAH metabolite concentrations compared to a historical reference group that did not do on-scene decontamination.56 Although our findings support both rinse only and soap/brush/rinse for reducing PFAS exposure, the “gold standard” seems to be the soap/brush/rinse method.

A policy to wash turnout gear prior to storing it was associated with significantly lower concentrations of total PFOA, and agencies where all employees are provided with a gear bag for transporting turnout gear were associated with lower concentrations of total and n-PFOA. Both findings align with our on-scene decontamination results. Another finding from our study was lower concentrations of PFOA associated with participating in an agency hood swap or weekly cleaning program. Although hood swap or weekly cleaning has not been evaluated for reducing PFAS exposure, previous studies have found lower urinary PAH-OHs associated with a greater frequency of laundering hoods.33,57 A policy to decontaminate apparatus interiors after a fire was significantly associated with lower concentrations of PFHpS, which may suggest that this PFAS type may be found in vehicle upholstery or cleaning products, or that should be further evaluated in fireground products of combustion. Lastly, we found a significant association between lower PFOA concentrations and frequently dusting the fire station living quarters (at least once per week). Another study measuring fluorine in fire station dust found high concentrations in fire station living room dust of N-EtFOSAA, which has been associated with consumer products, including carpet, and known to degrade to PFAAs.17

Other Associations With Serum PFAS Concentrations

We observed a significantly higher concentration of PFHpS associated with participating in an agency hood swap or weekly cleaning program, which we are unable to explain. The association between dusting every 2 weeks and higher concentrations of PFHpS was also unexpected and difficult to explain. Another unexpected finding was the association between station marked contamination zones and higher PFHxS concentrations. To our knowledge, this has not been evaluated in other studies, but these zones are intended to act as an administrative control to help reduce the amount of contaminated material that enters station living quarters.

As for other variables related to turnout gear, we did not find an association between PFAS concentrations and the number of times a firefighter has donned their gear in the past year. We did, however, observe lower concentrations of PFOS and PFHpS associated with not having a second set of gear to rotate between. We hypothesized that having a second set of gear would be beneficial for reducing exposure, but this finding suggests that having a second set of turnout gear could either be a potential source of exposure for these PFAS analytes or correlated with other variables associated with increased PFAS exposure. Our null findings related to advanced cleaning and inspection were unexpected given previous findings where lower serum concentrations of PFOA and PFNA were associated with having turnout gear sent for professional decontamination within the past 12 months.58

Lastly, our results revealed a negative association between firefighters with a BMI ≥30 kg/m2, and n-PFOS, total and n-PFOA, and PFHxS, contrary to evidence from other studies suggesting a link between PFAS concentrations and weight gain.59,60 Notably, among firefighters, who generally have more muscle mass, BMI may not accurately reflect fat composition, which has been seen among young athletes.61 Contrary to other reports, we also found lower serum PFAS concentrations associated with a higher frequency of eating pizza, fast food, and food from paper packaging, and we are unable to explain this finding.62

Strengths and Limitations

To our knowledge, our study had the largest population of firefighters with measured PFAS concentrations to date. Our study participants also represented seven US states, from the Southwest, Northwest, and Northeast regions, which increases the generalizability of our study findings. Additionally, our ability to collect agency-specific information from fire service liaisons allowed us to have more consistent and reliable agency-specific data. A major limitation of this study is that it was cross-sectional and not able to demonstrate that the significant associations were causative in nature. However, upon conclusion of the ongoing RCT, we will be able to evaluate the impact of interventions, such as blood and plasma donation, to reduce serum PFAS concentrations. Additionally, the interpretation of each survey question may have varied across participants and agency liaisons, leading to inconsistent responses.

CONCLUSION

The findings from this study provide evidence to support potential interventions or changes that can be implemented to reduce PFAS exposure among firefighters. Our results provide evidence to suggest that differences in PFAS concentrations may exist between lifestyle factors. Some factors that may be associated with lower serum PFAS concentrations include donating plasma or blood, checking drinking water for PFAS contamination and, if present, installing reverse osmosis filtration systems at home and at fire stations, or drinking bottled water instead of tap water. Other key findings from our study support occupational practices and policies to reduce PFAS exposure, including but not limited to performing on-scene decontamination (soap/brush/rinse) of turnout gear, weekly hood swap or cleaning programs, washing turnout gear prior to storing it, and removing carpeting from residential areas of fire stations. Future research to test the effectiveness of implementing these changes and policies is needed.

ACKNOWLEDGMENTS

We would like to thank the participating firefighters, our fire service research liaisons, fire departments, and IAFF locals for their support for the research.

Supplementary Material

joem-68-0577-s001.pdf (123.9KB, pdf)
joem-68-0577-s002.pdf (525.6KB, pdf)

Footnotes

Funding Sources: The study was supported by grants from the Arizona Board of Regents to the University of Arizona and Arizona State University and by NIEHS P30 ES006694.

Conflicts of Interest: F.C.W. received grants from external partners that were not related to this project, including NSF, Arizona Parks & Trails, Pac-12 Health and Wellbeing Initiative, CSPDA, Standard Process Inc., Kraft Heinz Company, Unilever Corporation, and FrieslandCampina. All other authors declare no conflicts of interest.

Author Contributions: R.C. assisted in program coordination, firefighter enrollment, and follow-up, and wrote parts of the manuscript. J.H. carried out statistical analysis for the study, assisted with firefighter enrollment and follow-up, and wrote part of the manuscript. S.B. enrolled and followed up with study participants and directed all field research activities. C.P. assisted with data management and manuscript review. O.H. assisted with ethics approval and firefighter enrollment. K.J.K. assisted with data management and manuscript review. J.J.G. enrolled and followed up with study participants and served as a community liaison. E.A.V. and O.J.G. served as community liaisons. K.L., F.C.W., and M.F. co-led the study. J.L.B. supervised all study activities and assisted with firefighter enrollment and follow-up.

Data Availability: Study data are not publicly available, and final datasets are accessible by approved study staff.

AI was not utilized in any stages of the hypothesis, data collection, data evaluation, manuscript preparation, etc.

Ethical Considerations and Disclosure(s): This study was approved by the University of Arizona Human Subjects Institutional Review Board (IRB) (FWA: 00004218, IRB Number: IRB00000291). Informed consent was obtained from all study participants.

Supplemental digital contents are available for this article. Direct URL citation appears in the printed text and is provided in the HTML and PDF versions of this article on the journal’s Web site (www.joem.org).

Contributor Information

Reagan Conner, Email: rconner@arizona.edu.

James Hollister, Email: jameshollister@arizona.edu.

Karen Lutrick, Email: klutrick@gmail.com.

Shawn C. Beitel, Email: sbeitel@arizona.edu.

Floris C. Wardenaar, Email: floris.wardenaar@asu.edu.

Cynthia Porter, Email: cynthiaporter@arizona.edu.

Olivia Healy, Email: healyo@arizona.edu.

Krystal J. Kern, Email: krystalaz@arizona.edu.

John J. Gulotta, Email: firecatjohn@gmail.com.

Eric A. Valliere, Email: evalliere@scottsdaleaz.gov.

Orion J. Godfrey, AS, Email: ojgodfrey@gmail.com.

Melissa Furlong, Email: mfurlong@arizona.edu.

Jefferey L. Burgess, Email: jburgess@arizona.edu.

REFERENCES

  • 1.Toxicological Profile for Perfluoroalkyls. Agency for Toxic Substances and Disease Registry; 2021: Available at: https://www.atsdr.cdc.gov/ToxProfiles/tp200.pdf. [PubMed] [Google Scholar]
  • 2.Lindstrom AB, Strynar MJ, Libelo EL. Polyfluorinated compounds: past, present, and future. Environ Sci Technol 2011;45:7954–7961. [DOI] [PubMed] [Google Scholar]
  • 3.Wang Z, DeWitt JC, Higgins CP, Cousins IT. A never-ending story of per- and polyfluoroalkyl substances (PFASs)? Environ Sci Technol 2017;51:2508–2518. [DOI] [PubMed] [Google Scholar]
  • 4.Buck RC, Franklin J, Berger U, et al. Perfluoroalkyl and polyfluoroalkyl substances in the environment: terminology, classification, and origins. Integr Environ Assess Manag 2011;7:513–541. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Li Y, Fletcher T, Mucs D, et al. Half-lives of PFOS, PFHxS and PFOA after end of exposure to contaminated drinking water. Occup Environ Med 2018;75:46–51. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kato K, Wong LY, Jia LT, Kuklenyik Z, Calafat AM. Trends in exposure to polyfluoroalkyl chemicals in the U.S. population: 1999–2008. Environ Sci Technol 2011;45:8037–8045. [DOI] [PubMed] [Google Scholar]
  • 7.Wen ZJ, Wei YJ, Zhang YF, Zhang YF. A review of cardiovascular effects and underlying mechanisms of legacy and emerging per- and polyfluoroalkyl substances (PFAS). Arch Toxicol 2023;97:1195–1245. [DOI] [PubMed] [Google Scholar]
  • 8.Margolis R, Sant KE. Associations between exposures to perfluoroalkyl substances and diabetes, hyperglycemia, or insulin resistance: a scoping review. J Xenobiot 2021;11:115–129. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Meneguzzi A, Fava C, Castelli M, Minuz P. Exposure to perfluoroalkyl chemicals and cardiovascular disease: experimental and epidemiological evidence. Front Endocrinol (Lausanne) 2021;12:706352. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Goodrich JM, Calkins MM, Caban-Martinez AJ, et al. Per- and polyfluoroalkyl substances, epigenetic age and DNA methylation: a cross-sectional study of firefighters. Epigenomics 2021;13:1619–1639. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Zahm S, Bonde JP, Chiu WA, et al. Carcinogenicity of perfluorooctanoic acid and perfluorooctanesulfonic acid. Lancet Oncol 2024;25:16–17. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Furlong MA, Liu T, Jung A, et al. Per- and polyfluoroalkyl substances (PFAS) and microRNA: an epigenome-wide association study in firefighters. Environ Res 2025;279(Pt 2):121766. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Rosenfeld PE, Spaeth KR, Remy LL, et al. Perfluoroalkyl substances exposure in firefighters: sources and implications. Environ Res 2023;220:115164. [DOI] [PubMed] [Google Scholar]
  • 14.Burgess JL, Fisher JM, Nematollahi A, et al. Serum per- and polyfluoroalkyl substance concentrations in four municipal US fire departments. Am J Ind Med 2023;66:411–423. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Rotander A, Toms LML, Aylward L, Kay M, Mueller JF. Elevated levels of PFOS and PFHxS in firefighters exposed to aqueous film forming foam (AFFF). Environ Int 2015;82:28–34. [DOI] [PubMed] [Google Scholar]
  • 16.Tao L, Kannan K, Aldous KM, Mauer MP, Eadon GA. Biomonitoring of perfluorochemicals in plasma of New York state personnel responding to the world trade center disaster. Environ Sci Technol 2008;42:3472–3478. [DOI] [PubMed] [Google Scholar]
  • 17.Young AS, Sparer-Fine EH, Pickard HM, Sunderland EM, Peaslee GF, Allen JG. Per- and polyfluoroalkyl substances (PFAS) and total fluorine in fire station dust. J Expo Sci Environ Epidemiol 2021;31:930–942. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Peaslee GF, Wilkinson JT, McGuinness SR, et al. Another pathway for firefighter exposure to per- and polyfluoroalkyl substances: firefighter textiles. Environ Sci Technol Lett 2020;7:594–599. [Google Scholar]
  • 19.Muensterman DJ, Titaley IA, Peaslee GF, et al. Disposition of fluorine on new firefighter turnout gear. Environ Sci Technol 2022;56:974–983. [DOI] [PubMed] [Google Scholar]
  • 20.Graber JM, Black TM, Shah NN, et al. Prevalence and predictors of per- and polyfluoroalkyl substances (PFAS) serum levels among members of a suburban US volunteer fire department. Int J Environ Res Public Health 2021;18:3730. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Nilsson S, Aylward L, Kay M, et al. Evaluation of Per- and Poly-Fluoroalkyl Substances (PFASs) in Airservices Australia's Aviation Rescue Fire Fighting Service (ARFFS) Staff—2018/2019. The University of Queensland; 2020: Available at: https://www.airservicesaustralia.com/wp-content/uploads/C02758-005_AirservicesExposureReport_Final.pdf. [Google Scholar]
  • 22.Nilsson S, Smurthwaite K, Aylward LL, et al. Serum concentration trends and apparent half-lives of per- and polyfluoroalkyl substances (PFAS) in Australian firefighters. Int J Hyg Environ Health 2022;246:114040. [DOI] [PubMed] [Google Scholar]
  • 23.Trowbridge J, Gerona RR, Lin T, et al. Exposure to perfluoroalkyl substances in a cohort of women firefighters and office workers in San Francisco. Environ Sci Technol 2020;54:3363–3374. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Gasiorowski R, Forbes MK, Silver G, et al. Effect of plasma and blood donations on levels of perfluoroalkyl and polyfluoroalkyl substances in firefighters in Australia: a randomized clinical trial. JAMA Netw Open 2022;5:e226257. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Burgess JL, Beitel SC, Calkins MM, et al. The fire fighter cancer cohort study: protocol for a longitudinal occupational cohort study. JMIR Res Protoc 2025;14:e70522. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Harris PA, Taylor R, Minor BL, et al. The REDCap consortium: building an international community of software platform partners. J Biomed Inform 2019;95:103208. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Hornung RW, Reed LD. Estimation of average concentration in the presence of nondetectable values. Appl Occup Environ Hyg 1990;5:46–51. [Google Scholar]
  • 28.Kenward MG, Roger JH. Small sample inference for fixed effects From restricted maximum likelihood. Biometrics 1997;53:983–997. [PubMed] [Google Scholar]
  • 29.R Core Team . R: a language and environment for statistical computing [published online 2022]. Available at: https://www.R-project.org/
  • 30.Liao M, Niu S, Fan W, Ma F, Dong Z. Increasing disparities in human exposure to perfluorooctanesulfonic acid: findings From per- and polyfluoroalkyl substance concentrations in 1999–2018 NHANES. Environ Technol Innov 2024;36:103824. [Google Scholar]
  • 31.Botelho JC, Kato K, Wong LY, Calafat AM. Per- and polyfluoroalkyl substances (PFAS) exposure in the U.S. population: NHANES 1999–March 2020. Environ Res 2025;270:120916. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Eriksson U, Mueller JF, Toms LML, Hobson P, Kärrman A. Temporal trends of PFSAs, PFCAs and selected precursors in Australian serum from 2002 to 2013. Environ Pollut 2017;220:168–177. [DOI] [PubMed] [Google Scholar]
  • 33.Hoppe-Jones C, Griffin SC, Gulotta JJ, et al. Evaluation of fireground exposures using urinary PAH metabolites. J Expo Sci Environ Epidemiol 2021;31:913–922. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Fillman T, Coffin S, Ta B, et al. Associations between PFAS in public water system drinking water and serum among Southern California adults [published online October 30, 2025]. J Expo Sci Environ Epidemiol. doi:10.1038/s41370-025-00817-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Teymoorian T, Munoz G, Vo Duy S, Liu J, Sauvé S. Tracking PFAS in drinking water: a review of analytical methods and worldwide occurrence trends in tap water and bottled water. ACS EST Water 2023;3:246–261. [Google Scholar]
  • 36.Liu C, Zhao X, Faria AF, et al. Evaluating the efficiency of nanofiltration and reverse osmosis membrane processes for the removal of per- and polyfluoroalkyl substances from water: a critical review. Sep Purif Technol 2022;302:122161. [Google Scholar]
  • 37.Thompson J, Eaglesham G, Reungoat J, et al. Removal of PFOS, PFOA and other perfluoroalkyl acids at water reclamation plants in South East Queensland Australia. Chemosphere 2011;82:9–17. [DOI] [PubMed] [Google Scholar]
  • 38.Hoffman K, Webster TF, Bartell SM, Weisskopf MG, Fletcher T, Vieira VM. Private drinking water wells as a source of exposure to perfluorooctanoic acid (PFOA) in communities surrounding a fluoropolymer production facility. Environ Health Perspect 2011;119:92–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Bradley PM, LeBlanc DR, Romanok KM, et al. Public and private tapwater: comparative analysis of contaminant exposure and potential risk, Cape Cod, Massachusetts, USA. Environ Int 2021;152:106487. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Cheryl, Maupin M, Caldwell R, et al. Estimated Use of Water in the United States in 2015. U.S. Geological Survey Circular 1441; 2018:65. https://doi.org/10.3133/cir1441. [Google Scholar]
  • 41.US EPA O . Private Drinking Water Wells. 2015. Available at: https://www.epa.gov/privatewells. Accessed August 28, 2025.
  • 42.Purdue MP, Rhee J, Denic-Roberts H, et al. A nested case-control study of serum per- and polyfluoroalkyl substances and testicular germ cell tumors among U.S. Air Force servicemen. Environ Health Perspect 2023;131:77007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Laitinen JA, Koponen J, Koikkalainen J, Kiviranta H. Firefighters' exposure to perfluoroalkyl acids and 2-butoxyethanol present in firefighting foams. Toxicol Lett 2014;231:227–232. [DOI] [PubMed] [Google Scholar]
  • 44.Bečanová J, Melymuk L, Vojta Š, Komprdová K, Klánová J. Screening for perfluoroalkyl acids in consumer products, building materials and wastes. Chemosphere 2016;164:322–329. [DOI] [PubMed] [Google Scholar]
  • 45.Hall SM, Patton S, Petreas M, et al. Per- and polyfluoroalkyl substances in dust collected from residential homes and fire stations in North America. Environ Sci Technol 2020;54:14558–14567. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Sonnenberg NK, Ojewole AE, Ojewole CO, Lucky OP, Kusi J. Trends in serum per- and polyfluoroalkyl substance (PFAS) concentrations in teenagers and adults, 1999–2018 NHANES. Int J Environ Res Public Health 2023;20:6984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Taylor KW, Hoffman K, Thayer KA, Daniels JL. Polyfluoroalkyl chemicals and menopause among women 20–65 years of age (NHANES). Environ Health Perspect 2014;122:145–150. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Wong F, MacLeod M, Mueller JF, Cousins IT. Enhanced elimination of perfluorooctane sulfonic acid by menstruating women: evidence from population-based pharmacokinetic modeling. Environ Sci Technol 2014;48:8807–8814. [DOI] [PubMed] [Google Scholar]
  • 49.Nematollahi AJ, Fisher JM, Furlong MA, et al. Comparison of serum per- and polyfluoroalkyl substances concentrations in incumbent and recruit firefighters and longitudinal assessment in recruits. J Occup Environ Med 2024;66:202–211. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Burnouf T. An overview of plasma fractionation. Ann Blood 2018;3. doi:10.21037/aob.2018.05.03. [Google Scholar]
  • 51.Bischel HN, MacManus-Spencer LA, Zhang C, Luthy RG. Strong associations of short-chain perfluoroalkyl acids with serum albumin and investigation of binding mechanisms. Environ Toxicol Chem 2011;30:2423–2430. [DOI] [PubMed] [Google Scholar]
  • 52.Gao Y, Kibbey TCG, Lee MJ, O’Carroll DM. Predicting salt effects on the binding of PFAS to protein. Environ Sci Technol 2025;59:26716–26728. [DOI] [PubMed] [Google Scholar]
  • 53.Perovani IS, Barbetta MFS, Duarte LO, de Oliveira ARM. Determination of polyfluoroalkyl substances in biological matrices by chromatography techniques: a review focused on the sample preparation techniques—review. J Chromatogr Open 2023;3:100082. [Google Scholar]
  • 54.Fent KW, Alexander B, Roberts J, et al. Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures. J Occup Environ Hyg 2017;14:801–814. [DOI] [PubMed] [Google Scholar]
  • 55.Calvillo A, Haynes E, Burkle J, et al. Pilot study on the efficiency of water-only decontamination for firefighters' turnout gear. J Occup Environ Hyg 2019;16:199–205. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Burgess JL, Hoppe-Jones C, Griffin SC, et al. Evaluation of interventions to reduce firefighter exposures. J Occup Environ Med 2020;62:279–288. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Mayer AC, Fent KW, Bertke S, et al. Firefighter hood contamination: efficiency of laundering to remove PAHs and FRs. J Occup Environ Hyg 2019;16:129–140. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Dobraca D, Israel L, McNeel S, et al. Biomonitoring in California firefighters: metals and perfluorinated chemicals. J Occup Environ Med 2015;57:88–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Cardenas A, Hauser R, Gold DR, et al. Association of perfluoroalkyl and polyfluoroalkyl substances with adiposity. JAMA Netw Open 2018;1:e181493. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Lewis N, Abdulkadir A, Kandel S, Rosby R, Hossain E. Per- and polyfluoroalkyl substances (PFAS) as emerging obesogens: mechanisms, epidemiological evidence, and regulatory challenges. Physiologia 2024;4:517–567. [Google Scholar]
  • 61.Kruschitz R, Wallner-Liebmann SJ, Hamlin MJ, et al. Detecting body fat—a weighty problem BMI versus subcutaneous fat patterns in athletes and non-athletes. PLoS One 2013;8:e72002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Susmann HP, Schaider LA, Rodgers KM, Rudel RA. Dietary habits related to food packaging and population exposure to PFASs. Environ Health Perspect 2019;127:107003. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

joem-68-0577-s001.pdf (123.9KB, pdf)
joem-68-0577-s002.pdf (525.6KB, pdf)

Articles from Journal of Occupational and Environmental Medicine are provided here courtesy of Wolters Kluwer Health

RESOURCES