Skip to main content
. 2006 Jan 6;103(3):511–518. doi: 10.1073/pnas.0510113103

Table 1. Cardiac function in WT and RyR2-S2808A mice at 4 weeks after MI.

WT (20) S2808A (17)
Age, months 5.0 ± 0.3 4.8 ± 0.3
Body weight, g 24.99 ± 0.67 25.11 ± 0.89
Infarct size, % 36.50 ± 3.10 36.05 ± 3.27
HW/BW ratio 7.65 ± 0.39 8.32 ± 0.43
Echocardiography
    Ejection fraction, % 33.76 ± 3.67 50.43 ± 3.29*
    Fractional shortening, % 14.86 ± 1.93 22.73 ± 2.00**
    Stroke volume, μl 87.6 ± 0.74 112.6 ± 0.75*
    LVPW, mm 0.84 ± 0.01 0.78 ± 0.02**
    EDD, mm 5.21 ± 0.13 4.70 ± 0.13*
    ESD, mm 3.98 ± 0.16 3.51 ± 0.15*
Cardiac catheterization
    dP/dt, mmHg/s 5,641 ± 304 6,810 ± 397*
    -dP/dt, mmHg/s -4,804 ± 275 -5,917 ± 412*
    MAP 75.85 ± 2.30 80.30 ± 3.91

Analysis of in vivo cardiac size and function by echocardiography and cardiac catheterization in wild-type and RyR2-S2808A mice. Number in parentheses represents number of mice. LVPW, left ventricular posterior wall thickness; EDD, end-diastolic diameter; ESD, end-systolic diameter; dP/dt, slope of the maximal derivative of change in pressure over time; -dP/dt, slope of the maximal negative derivative of change in pressure over time; MAP, mean arterial blood pressure. *, P < 0.05; **, P < 0.01.