Table 2.

Table Characteristics of included studies.

Study ID and design Participants / Implants with Location,Intervention IOS system and digital analysis software Outcomes assessed and Comparator Major findings Limitations
Xiong et al. [9] prospective clinical study 16 / 16 anterior maxillaIntervention: IOS of peri-implant soft tissue with and without implant-supported provisional restoration (ISPR) TRIOS (3Shape, Copenhagen, Denmark)Software: Geomagic Control X (3D Systems, Rock Hill, USA) Peri-implant soft tissue deviation (µm) in 2D and 3D; accuracy of mucosal profile replicationComparator: conventional impression using ISPR as impression coping Removal of ISPR led to rapid peri-implant mucosal collapse. IOS with ISPR in place showed significantly higher accuracy than IOS without ISPR (mean 3D deviation: 230.6 ± 85.5 μm vs 414.7 ± 116.0 μm; p < .0001) Small sample size; limited to single implants on only anterior maxilla; short-term assessment; conventional impression may introduce material-related inaccuracies
da Silva Marques et al. [10] cross-over pilot clinical study 6 / 6 anterior maxillaIntervention: digital intraoral impression obtained immediately after removal of provisional crown and compared with conventional impression using customized implant impression coping (CIIC) TRIOS (3Shape, Copenhagen, Denmark)Software: Geomagic Design X (3D Systems, Rock Hill, USA) 3D trueness (RMS, μm) of hard and soft tissues, peri-implant emergence profile, effect size (Hedges’ g)Comparator: conventional polyvinyl siloxane impression with customized implant impression coping and extraoral scanning Digital impressions showed statistically significant differences in peri-implant soft tissue replication compared with CIIC (overall RMS ≈ 244 μm; large effect size), but discrepancies were below the clinically detectable threshold (1 mm) Small sample size; pilot design; limited to single implants on only anterior maxilla; no correlation analysis for implant depth, connection type, or gingival biotype; clinical impact on esthetic outcomes not assessed
Duran et al. [11] pilot clinical study 10 / 10 anterior maxillaIntervention: digital intraoral impression of peri-implant soft tissue immediately after removal of implant-supported fixed interim restoration (ISFIR); STL superimposition and linear cross-sectional measurements CEREC Omnicam (Sirona Dental Systems, Bensheim, Germany)Software: Cerec SW 4.4 (SironaDental System, Bensheim, Germany) Linear dimensional changes (mm) of peri-implant soft tissue profile in buccolingual and mesiodistal directions at coronal and mid-gingival levelsComparator: conventional polyvinyl siloxane impression using ISFIR as customized impression transfer, followed by stone cast fabrication and digital scanning Significant dimensional discrepancies were observed between the ISFIR emergence profile and unsupported peri-implant soft tissue captured by IOS, with deviations up to 1.35 mm buccolingually and 1.29 mm mesiodistally; digital impressions did not accurately reproduce soft tissue contours after ISFIR removal Small sample size; pilot design; only single implants in the anterior maxilla; absence of repeated measurements; only linear (2D) measurements performed; short observation period
Ling et al. [12] prospective clinical pilot study 14 / 20 anterior maxillaIntervention: comparison of direct versus indirect IOS techniques for duplicating peri-implant soft tissue contour during definitive crown delivery; STL superimposition before and after delivery TRIOS 3 (3Shape, Copenhagen, Denmark)Software: DentalDB (Exocad GmbH, Darmstadt, Germany) Linear deviations of peri-implant mucosa (labial and palatal gingival margin height, thickness); volumetric deviations of labial and palatal soft tissue; PESComparator: direct digital impression technique based on peri-implant soft tissue profile immediately after provisional crown removal Indirect technique resulted in significantly smaller labial and palatal tissue thickness deviations and lower labial soft-tissue volume changes compared with the direct technique; palatal tissue collapse occurred mainly with the direct technique; no significant differences in PES between techniques Pilot design; limited sample size; no conventional impression control; short-term evaluation only; limited to single implants on only anterior maxilla; long-term esthetic stability not assessed
Docampo-Vázquez et al. [13] pilot clinical trial 10 / 10 mandibleIntervention: free gingival graft performed to increase peri-implant keratinized tissue; serial digital IOS obtained preoperatively and at 1 week, 1, 3, and 6 months to assess healing True Definition (3M ESPE, Saint Paul, USA)Software: 3D Geomagic Capture Wrap (3D Systems, Rock Hill, USA) Volumetric changes (mm³) of peri-implant soft tissues at donor and recipient sites; linear width of keratinized tissue; repeatability and reproducibility (Gage R&R)Comparator: conventional clinical linear measurements (endodontic file with rubber stop) Digital technique demonstrated high repeatability and reproducibility (<10% variability); recipient sites showed significantly higher soft-tissue volume than donor sites at all follow-ups; no significant differences between digital and conventional methods for linear width, but conventional measurements lacked repeatability Pilot study with small sample size; limited to implants in overdenture patients; no comparison with other soft-tissue augmentation techniques or materials; volumetric assessment limited to implant sites only

2