Table 2.

Summary of articles included in the systematic review on virtual facebow techniques

Author & Year Type of Study Aim Sample Study Group Scan Method/Type Articulator Type Anatomical References Alignment System Mounting Process CAD Software Program to Alignment Conclusion
Kalman, 2016 [28] Clinical technique Develop a digital alternative and arbitrary mounting to address the shortcomings of the traditional facebow and provide additional clinical information. 2 separate sets of models poured in Microstone by each clinician technique

Clinician A

Timed analog facebow (AF)

Conventional: CounterFit impression material & Quick Bite N/A Analog facebow & wax bite registration Analog facebow & wax bite Number of occluding teeth checked with 8 μm shim stock. Mobile technology- application The efficiency, accuracy, cost, and comfort of the VF provide the clinician with an alternative tool for records and essential technician communication.

Clinician B

Virtual facebow (VF)

Semi-adjustable articulator Whip Mix Virtual facebow application & record Face and dentition capture with reference grid and gyroscope
Lam, 2018 [5] Clinical technique Present a digital workflow for registering the patient’s horizontal plane in natural head position (NHP) on a virtual articulator. 1 patient 5 attempts of scans were done for the same patient

Stereophotogrammetry (SP) device (3dMDface, 3dMD Inc) used to scan the face.

Teeth scanned with intraoral scanner (True definition; 3 M). Another SP scan with virtual facebow in position.

Denar Mark II articulator, Whip Mix Buccal relationship of maxillary teeth & virtual facebow, 3D facial photograph, full-face cone beam computed tomography (CBCT). Orientation reference board calibrates a stereophotogrammetry device and a 3D facial photograph of patient in NHP. Load virtual patient model into Exocad, match THA to condylar element of the virtual articulator. Exocad; GmBH Casts mounted with NHP techniques have higher position in the articulator than those mounted with anatomic facebow technique.
Maveli, 2018 [29] In vitro Evaluate the coronal and sagittal orientation of the occlusal plane on maxillary casts mounted with an electronic application facebow system onto a semiadjustable arcon articulator. Sample size: 30, 2 groups Control group: 15 impressions of maxillary typodont Polyvinyl siloxane impression material used to take impression of maxillary typodont attached to phantom mannequin head that has anterior landmarks (infraorbital rim & foramina). Semi- Adjustable arcon Whip Mix Model 3040 Articulator Frankfort horizontal plane and occlusal plane (OP) Tablet calibration tool used, casts positioned on the stand with central incisors to a specific line. After alignment, another photograph was made and overlaid with the photograph of the phantom head. Overlay of photograph of the phantom head aligned to central incisors MaxAlign LabStand; Whip Mix Corp

MaxAlign system transferred the OP orientation more accurately for the sagittal plane than the coronal plane.

Significant variation in coronal OP between test and control group that could have significant esthetic and functional implications.

No significant differences were found in the sagittal orientation of the OP.

Test group: 15 records using MaxAlign system (Whip Mix Corp) digital application on tablet Tablet was placed on a stand and calibrated, 23 cm away and parallel to phantom head, photograph was taken from the application.
Amezua, 2022 [11] In vitro Analyze the influence of the facial scanning method on the accuracy with which a maxillary digital scan is transferred to a 3D face scan in a virtual facebow technique. 2 groups, 21 pairs of maxillary digital scans

Structured white light (SWL)

technology (10 scans).

Maxillary digital scan (industrial reference scanner), and 3D face scan N/A Maxillary digital scan and standard virtual patient

Virtual facebow transfer (VFT) by

intraoral transfer element (IOTE) kept in during face scans, removed, scanned with the impression material inside it, and another face scan without IOTE placed.

N/A Geomagic Studio 2013, closest point algorithm/iterative closest point (ICP)

The accuracy with which a maxillary scan is transferred to a 3D face scan in a virtual facebow technique is strongly influenced by the facial scanner.

Inaccuracies have been introduced when transferring a maxillary digital scan to a 3D face scan.

Significant differences among trueness values when using different facial scanning methods with a very large effect size.

Trueness of 0.138 mm and precision of 0.022 mm obtained by using SWL compared to trueness of 0.416 mm and precision of 0.095 mm was acquired from SFM scanning method.

Structure-from-motion (SFM) technology (10 scans).

27 digital photographs of the mannequin’s face at different positions and angles. Photos uploaded to digital image-processing & 3D data-generation software program (Agisoft).

Li, 2022 [30] Clinical technique To investigate the trueness and precision of virtual facebow records using a smartphone as a 3D face scanner. 2 subjects 10 repeated virtual facebow records for each subject Intraoral scan of maxillary arch (TRIOS), 3D facial scan with smartphone application (Hege 3D scanner). Not mentioned 3 points: mesh spheres with diameter of 0.5 mm added to mesial buccal cusps of the left #14, right #3, and the mesial incisor angle of #9. Facebow fork placed, and scan taken with it N/A Blender, version 2.8 and DentalCAD software (Exocad 2.2) Virtual records made using smart-phone scans can capture maxilla position with high trueness and precision. Deviation anticipated to be around 1 mm in linear distance and 1º in angulation.
Inoue, 2024 [4] Pilot clinical study To determine differences in measurements among casts mounted virtually by using the average values of the Bonwill triangle and the Balkwill angle, casts mounted by using facebow records, and casts mounted from 3D facial scans. 10 participants (3 men, 7 women) with complete maxillary and mandibular dentitions Facebow preservation group (FPG) Intraoral scans, 3D printed models, face bow record (Artex Rotofix; Amann Girrbach AG), desktop scanner (Freedom HD; Degree of Freedom Inc) used to preserve the mounting Semi-adjustable arcon articulator- (Artex CR; Amann Girrbach AG) Right & left external auditory meatus, point at 42 mm inferior to nasal locator of the facebow Facebow (Artex Rotofix; Amann Girrbach) All mounted with same maxillomandibular relationship ExodCAD; exocad GmbH, distances were measured from mesiobuccal tip of mandibular first molar to center of left condyle with incisal pin at 0 mm, 3 mm, and 5 mm.

1.Accuracies of FPG & FSG were comparable without statistical differences

2.AMG produced lower accuracy than FPG & FSG; however, increase in vertical dimension up to 5 mm was not significantly different

3.Use of 3D facial scanner to virtually mount dental casts provides a suitable option for the restorative dentist

-Both anterior and posterior condylar measurements between the FPG & AMG were found to be sig different, while comparisons between the FPG & FSG were found not sig different.

-All changes in vertical dimension were found not to be sig different with respect to both anterior & posterior measurements.

Average mounting group (AMG) Intraoral digital scans mounted virtually with Bonwill triangle and Balkwill angle concepts Incisal edge of mandibular central incisor (anterior reference) and mesiobuccal cusp tips of mandibular first molars (posterior reference) Average values of Bonwill triangle & Balkwill angle
Facial scan group (FSG) Casts digitized and superimposed on facial scans using a target system Bergstrom point, glabella, and orbitale Target facebow fork system with a facial scanner used to superimpose facial scans with STL files
Revilla-León, 2024 [26] (a) In vitro Compare the accuracy of the maxillary cast transfer into the virtual semi-adjustable articulator by using analog and digital methods.

3 groups

n=10

Conventional facebow (CNV)

Reference scan; Industrial scanner (Gom ATOS Q3D 12 M). Study group: Max typodont; T170;Medit),

Digitized facebow record

Panadent PCH Articulator, exocad GmbH Reference glasses 3.0; Kois Center +Kois dentofacial analyzer system + LazrTrak Reference platform (Kois adjustable platform) (DentalCAD) Digitized facebow superimposed with the virtual reference Kois table (Kois Platform; exocad GmbH) Dental CAD Software, v3.1 Rijeka, exocad GmbH

P group demonstrated best trueness & precision values. The maxillary cast transfer accuracy ranged from 137 ±44 μm to 453 ±176 μm among techniques.

Midline evaluation a no trueness & precision.

Significant posterior right anterior, posterior left, and overall trueness discrepancies among the groups.

P group obtained best posterior R & L and overall precision and trueness.

P & FS groups demonstrated best anterior trueness but no anterior precision discrepancies were found.

Digital photograph (P group) 10 digital photographs (jpeg) with a DSLR D780, Marcolens 105 mm, and maxillary scan Photographs with levelled Kois reference glasses Rescaled photograph, maxillary scan positioned on Kois reference table & aligned with photo
Facial scanning with a 3D extraoral scan body (FS) Facial scan (Instarisa 3.0 Facial Scanner) with extraoral scan body in place on mannequin; exported as PLY, without scan body, mannequin scanned with laboratory scanner (Gom ATOS Q3D 12 M), Facial scan with a 3D extraoral scan body with grid Digitized extraoral scan body with Kois reference table
Revilla-León, 2024 (b) [31] In vitro Compare the accuracy of maxillary cast transfer into the virtual semi-adjustable articulator by using an analog and digital standardized photography technique 2 groups Conventional facebow (CNV) Laboratory scanner (T710; Medit) scan of maxillary dentate cast with a magnet, mannequin positioned in a tripod, reference scan of the assembled mannequin obtained with facial scanner Panadent PCH Articulator; exocad GmbH

CNV group:

Kois disposable tray in the facebow of the dentofacial analyzer system (Kois, Panadent), facebow acquired, digitized with same laboratory scanner

Digitized facebow superimposed with virtual reference Kois table of semi-adjustable by using disposable index as common information N/A DentalCAD, v.3.1 Rijeka; Exocad GmbH

Facebow record methods impacted trueness and precision of maxillary cast transfer into virtual semi-adjustable articulator.

Photo group obtained better trueness in midline transfer compared to CNV. CNV obtained better trueness in anterior, posterior right & left, overall discrepancy compared to P group. P group obtained better precision in midline, posterior right & left, anterior and overall discrepancy of maxillary cast transfer compared to CNV.

Overall discrepancy measured in CNV group was 0.620 ± 0.396 mm, in P group was 1.282 ± 0.118 mm.

Sig trueness differences found in midline, anterior, posterior right, posterior left, and overall discrepancy between CNV & P groups.

P group: 10 digital photos with levelled Kois reference glasses Photographs rescaled, aligned with maxillary scan
Villanueva et al. 2025 [27] Clinical dental technique describes a digital technique for virtual mounting in a semi-adjustable articulator by integrating CBCT and intraoral and facial scans Single patient

intraoral scans of the maxillary and

mandibular arches

+ CBCT

+

facial scan

maxillary intraoral scan (reference scan)

CBCT

Facial scan

1. Mesiobuccal cusps of the bilateral first molars and the distoincisal angles of the maxillary lateral incisors as craniofacial reference points to establish a stable 4-point registration (align CBCT to intraoral scan)

2. Reference points on the cusp

tips of both maxillary canines and the midpoint of

the central incisors (align face scan to intraoral scan)

best-fit algorithm to refine

the superimposition coincides

at the defined reference points and along the occlusal plane ensuring

symmetry with the facial midline and interpupillary line

aligning the Frankfort

horizontal plane with the articulator reference

plane using digital semi-adjustable articulator (BioArt

A7 Plus)

Exocad; GmBH

By eliminating analog transfers, it improves accuracy, reduces

variability, and enhances communication among specialists

Kim, 2025 [32] In vivo Compare accuracy of a novel virtual facebow transfer (VM) technique based on CBCT with that of conventional mounting (CM) technique using a facebow. 5 repeated mountings for with each technique for 15 participants Conventional mounting technique CBCT, preliminary impressions à Casts, one cast was digitalizedà STL Hanau Modular Articulator System, WhipMix Corp scanned with 5 cube shaped markers with an industrial scanner as the reference articulator (RA-STL). Anatomical Frankfort horizontal plane, infraorbital notch.

For CM group

(Hanau Springbow; WhipMix Corp)

Mounted conventionally with facebow, then with cast on articulator, industrial scanner scan it all; TEMPLATE Geomagic Control X v2018.0.1; 3D Systems

Significant differences found between 2 groups, VM more precise technique.

Position of maxillary right central incisor indicated VM casts were positioned ahead of CM casts.

Occlusal plane angle tended to be steeper in CM casts than VM casts.

Mean distance between target points was significantly greater in the CM group than VM.

Standard deviation between target points was sig greater in CM group than VM.

Virtual facebow transfer technique References from the skull: Bilateral porions, condyle, external acoustic meatuses, orbit, midline, sagittal suture, & spine

For VM group:

CBCT, STL files of their skulls were obtained

Superimposing the scans with the CBCT.