Abstract
Objective
To evaluate the reliability of physical examination tests used for assessing hip flexor flexibility, including the Modified Thomas Test (MTT), Thomas Test, Reactive Hip Flexor Test, Swing Test, and Falcon Test.
Literature Survey
A systematic search was conducted across multiple databases (PubMed, CINAHL, SPORTDiscus, Scopus, Web of Science, and Rehabilitation & Sports Medicine Source) up to March 2024.
Methodology
Studies were included if they reported intra‐ or interrater reliability outcomes for clinical tests assessing hip flexor flexibility, using recognized statistical measures such as the intraclass correlation coefficient (ICC), SEM, minimal detectable change, or Bland–Altman plots. The methodological quality of included studies was assessed using the Quality Appraisal of Reliability Studies checklist. Meta‐analyses were performed using random‐effects models to calculate pooled ICC values for intra‐ and interrater reliability, with subgroup analyses based on the type of flexibility test.
Synthesis
The meta‐analysis included 27 studies, comprising 1056 participants. The overall pooled intrarater ICC was 0.90 (95% CI, 0.85–0.95) in 888 participants, indicating excellent reliability, and the interrater ICC was 0.80 (95% CI, 0.71–0.88) in 665 participants, reflecting good reliability. However, substantial heterogeneity was observed for both intrarater (I2 = 99%) and inte‐rater (I2 = 98.3%) analyses, particularly for the MTT and Thomas Test. In contrast, the Thomas Test demonstrated the lowest interrater reliability (ICC, 0.62 [95% CI, 0.46–0.78]) with significant between‐study variability.
Conclusions
Physical examination tests for hip flexor flexibility demonstrate generally high intra‐ and interrater reliability. However, considerable methodological variability was identified, particularly for the MTT and Thomas Test, suggesting a need for standardized protocols. Newer tests, such as the Falcon and Swing Tests, showed excellent reliability but require further validation.
INTRODUCTION
The hip joint is fundamental in facilitating a wide range of movement essential for daily activities and athletic performance. 1 Central to its function are the hip flexor muscles, including the iliopsoas, rectus femoris, and sartorius, which enable flexion of the thigh toward the torso. 2 Maintaining optimal flexibility of these muscles may be beneficial, as tightness or shortening can lead to altered biomechanics, diminished performance, and an increased risk of musculoskeletal injuries, particularly in the lower back, hips, and knees. 2 , 3 , 4 Accurate assessment of hip flexor flexibility is, therefore, imperative for clinicians and researchers aiming to diagnose limitations, develop effective intervention strategies, and monitor rehabilitation progress. 4
Several clinical tests have been developed to evaluate hip flexor flexibility, with the Modified Thomas Test (MTT) being among the most employed. 5 , 6 , 7 , 8 The MTT involves positioning the patient supine at the edge of an examination table, allowing one leg to hang freely while the other is flexed toward the chest. The angle of the hanging leg provides an indication of hip flexor length. 9 Despite its widespread use, the reliability of the MTT has been a subject of debate. Factors such as inconsistent pelvic stabilization and variations in contralateral hip positioning have been identified as potential sources of measurement error, leading to conflicting reports regarding its intra‐ and interrater reliability. For instance, uncontrolled pelvic tilt during the MTT can result in an overestimation of hip extension, thereby compromising the test's accuracy. 10 , 11 To address these concerns, some studies have emphasized the importance of controlling pelvic tilt to enhance the test's reliability. 11
In addition to the MTT, other assessment tools, such as goniometric measurements, have been used to quantify hip flexor flexibility. 12 , 13 Goniometers provide angular measurements of joint motion and are commonly used in clinical settings due to their simplicity and cost‐effectiveness. The reliability of goniometric measurements in assessing hip flexor length has also been explored, with some studies reporting good‐to‐excellent reliability. 13 , 14 However, like the MTT, variations in measurement techniques and examiner experience can influence the outcomes, underscoring the need for standardized protocols. Recently, alternative tests such as the Reactive Hip Flexor (RHF) Test, Swing Test, or Falcon Test have been introduced to assess hip flexor flexibility. 6 , 7 , 15 These emerging assessments may provide more dynamic and functionally relevant evaluations of hip flexor flexibility. Specifically, the RHF, Swing, and Falcon tests evaluate the interaction between both lower limbs during a simultaneous movement pattern (hip and knee flexion on one side and hip extension on the contralateral limb). This mimics the reciprocal limb coordination seen during gait or running.
Reliability is crucial in assessing hip flexor flexibility, ensuring that measurement tools produce consistent and reproducible results. Key statistical indices such as the intraclass correlation coefficient (ICC), 16 SEM, Minimal Detectable Change (MDC), and percentage change help quantify measurement accuracy and clinical significance. 17 , 18 , 19 These metrics are essential in determining the reliability of both traditional and emerging hip flexor flexibility assessments, guiding their application in clinical and research settings.
To date, no systematic review has comprehensively evaluated the reliability of physical examination tests for assessing hip flexor flexibility. Given the emergence of new research and assessment techniques, there is a need to systematically summarize and critically appraise the reliability of these tests. Therefore, the objective of this systematic review is to evaluate the reliability of physical examination tests used for the assessment of hip flexor flexibility, providing clinicians with evidence‐based recommendations for practice.
METHODS
Study design
This systematic review with meta‐analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines. 20 Electronic databases were systematically searched up to March 2024, including PubMed, CINAHL, SPORTDiscus, Scopus, Web of Science, and Rehabilitation & Sports Medicine Source (International Prospective Register of Systematic Reviews ID: CRD420251007117).
Search Strategy
The search strategy was developed to be comprehensive and systematic. It combined controlled vocabulary (eg, Medical Subject Heading terms) and free‐text keywords related to three main domains: (1) the target anatomical structures (eg, hip flexors, iliopsoas, rectus femoris), (2) measurement properties (eg, intrarater reliability, test–retest reliability, measurement error), and (3) the type of assessment (eg, clinical test, physical examination). Boolean operators and truncations were used to maximize both sensitivity and specificity of the search strategy across databases. No restrictions were applied regarding publication date or language. In addition, reference lists of included studies and relevant reviews were manually screened to identify any additional eligible articles. The full search strategies for each database are provided in Appendix 1.
Inclusion and exclusion criteria
This review included studies based on the following predefined eligibility criteria:
Studies involving human participants of any age, gender, or activity level were eligible. Both healthy individuals and those with musculoskeletal conditions were considered, provided that intrarater reliability outcomes were reported separately for each subgroup, where applicable.
Eligible studies evaluated clinical tests designed to assess hip flexor flexibility, including but not limited to the Thomas Test, Modified Thomas Test, Passive Hip Extension Test, or any other standardized physical examination procedure targeting the hip flexor muscle group (eg, iliopsoas, rectus femoris, tensor fasciae latae).
Observational studies (cross‐sectional, prospective, or retrospective) that reported intra‐rater or interrater reliability outcomes using recognized statistical measures such as the ICC, Cohen's or Fleiss' Kappa, SEM, MDC, or Bland–Altman plots.
Studies were excluded if they (1) did not assess clinical tests specifically intended to measure hip flexor flexibility, (2) did not report numerical reliability outcomes, or (3) were not original research (eg, reviews, conference abstracts, expert opinions, or case studies). No restrictions were applied regarding the clinical or research setting in which the tests were performed (eg, hospitals, rehabilitation centers, sports science laboratories). Only studies published in peer‐reviewed journals were considered, with no restrictions on language or year of publication. Regarding the methods, no restrictions were applied concerning the ICC calculation approach, the number of raters involved, or the minimum sample size of participants.
Study selection and data extraction
Title and abstract screening were performed independently by two reviewers, followed by full‐text review of potentially eligible studies according to the predefined inclusion and exclusion criteria. Disagreements were resolved through discussion and consensus.
From each included study, the following data were extracted using a standardized form: first author, year of publication, sample size, participant characteristics (eg, healthy or clinical population), type of hip flexor flexibility test, and reported ICC values, along with 95% confidence intervals (CIs), SEM, and MDC when available. In cases where multiple ICC values were reported for different raters, limbs, or testing procedures within the same study, each value was extracted and treated as an independent data point in the analysis.
Quality assessment
The methodological quality of the included studies was assessed independently by two reviewers using the Quality Appraisal for Reliability Studies (QAREL) checklist. 21 The QAREL checklist consists of 11 items, specifically designed to evaluate potential sources of bias and methodological rigor in reliability studies. These items address key aspects such as examiner blinding, examiner independence, appropriate intervals between assessments, adequacy of sample selection, detailed descriptions of test procedures, standardized methods of administration, and appropriate statistical analyses. Each item is rated as “yes,” “no,” or “unclear,” facilitating an objective evaluation of study quality. Disagreements between reviewers were resolved through consensus or consultation with a third reviewer when necessary. For the agreement between reviewers in the QAREL assessment, Cohen's kappa coefficient was calculated to quantify interrater reliability.
Statistical analysis
The meta‐analysis was performed using a random‐effects model due to anticipated methodological and clinical heterogeneity across studies. ICC values and their 95% CIs were pooled to calculate overall intra and interrater reliability estimates. The interpretation of ICC values in this review followed established guidelines proposed by Koo and Li, 16 whereby ICC values <0.50 were considered to indicate poor reliability, values between 0.50 and 0.75 indicated moderate reliability, values between 0.75 and 0.90 were considered good reliability, and values >0.90 indicated excellent reliability. Heterogeneity between studies was quantified using Cochran's Q test and I2 statistic, where values of 25%, 50%, and 75% indicated low, moderate, and high heterogeneity, respectively. Subgroup analyses were conducted based on the type of hip flexor flexibility test utilized (Modified Thomas Test, Reactive Hip Flexor Test, Thomas Test, Swing Test, and Falcon Test). Publication bias was visually assessed using funnel plots. All analyses were conducted using the R statistical software (version 4.3.3) with the meta package. Statistical significance was set at a p value <.05. 22 , 23 , 24
RESULTS
A total of 502 records were identified from database searches. After removing duplicates (n = 270), 232 studies were screened based on titles and abstracts. Of these, 191 studies were excluded for not meeting initial eligibility criteria. Forty‐one full‐text articles were assessed, resulting in the exclusion of 14 articles that did not evaluate hip flexor flexibility tests. Consequently, 27 studies were included in the qualitative synthesis, and 21 of these provided adequate data for inclusion in the quantitative meta‐analysis (Figure 1).
FIGURE 1.

Preferred Reporting Items for Systematic Reviews and Meta‐Analyses flow diagram. WOS, Web of Science.
Descriptive data
A total of 27 studies were included in this systematic review, assessing five different hip flexor flexibility tests: the MTT (14 studies), Thomas Test (7 studies), RHF Test (1 study), Swing Test (1 study), and Falcon Test (1 study). Collectively, these studies involved 1056 participants, distributed as follows: MTT (726 participants), Thomas Test (241 participants), Falcon Test (53 participants), RHF Test (26 participants), and Swing Test (10 participants). Regarding participant characteristics, the majority of studies (23 studies) involved healthy participants, and 5 studies included participants with specific pathologies: cerebral palsy (4 studies), osteoarthritis (1 study), and groin pain (1 study); one study included more than one pathology group. Various methods were used to assess hip flexor flexibility across the included studies, with goniometry (11 studies) and inclinometry (5 studies) being the most frequent. Other reported methods were video or motion analysis software (5 studies), smartphone digital goniometry (1 study), manual palpation combined with orthopedic testing (1 study), dynamometry (1 study), inertial motion capture with tape measurement (1 study), and digital imaging (1 study). Several studies employed more than one evaluation method (Table 1).
TABLE 1.
Descriptive summary of included studies.
| Study | N | Population | Test method | Intrarater (ICC, SEM, MDC) | Interrater (ICC, SEM, MDC) | Kappa intra | Kappa inter | Bland–Altman |
|---|---|---|---|---|---|---|---|---|
| Modified Thomas Test | ||||||||
| Kim et al. 11 | 13 | Healthy | Video and software angle measurement |
General: ICC = 0.97 (0.91–0.99); SEM = 1.51; MDC = 4.17 Active: ICC = 0.99 (0.98–0.99); SEM = 0.95; MDC = 2.35 Passive: ICC = 0.98 (0.95–0.99); SEM = 1.34; MDC = 3.70 |
Not reported | – | – | No |
| Peeler et al. 5 | 57 | Healthy | Goniometer | ICC = 0.67 (0.55–0.76); SEM = 7 | ICC = 0.50 (0.40–0.60) | Kappa = 0.40 | Kappa = 0.33 | Yes |
| Wakefield et al. 29 | 22 | Healthy | Goniometer and trigonometric |
Examiner 1: ICC = 0.51 (−0.19–0.80); SEM = 4 Examiner 2: ICC = 0.54 (−0.05–0.80); SEM = 4 |
Examiner 1: ICC = 0.65 (0.20–0.85); SEM = 3 Examiner 2: ICC = 0.30 (−0.75–0.71); SEM = 5 |
– | – | Yes |
| Eimiller et al. 13 | 64 | Healthy | Video analysis | Left ICC = 0.899; Right ICC = 0.923 | Left ICC = 0.871; Right ICC = 0.831; SEM = 2.85 | – | – | Yes |
| Cady et al. 32 | 20 | Healthy | Digital imaging | Not reported | Not reported | – | – | No |
| Peeler et al. 36 | 28 | Healthy | Dynamometer |
Experienced ICC = 0.98 (0.97–0.99); SEM = 0.35 Inexperienced ICC = 0.98 (0.97–0.99); SEM = 0.40 |
ICC = 0.97 (0.96–0.98) | – | – | Yes |
| Dennis et al. 37 | 36 | Healthy | Goniometer and Videos | MTT hip extension ICC = 0.97 (0.84, 0.99); SEM = 1.3/MTT hip abduction ICC = 0.83 (0.21, 0.92); SEM = 1.3. | MTT hip extension ICC = 0.27 (0.00, 0.76); SEM = 6.6; no MDC/MTT hip abduction ICC = 0.29 (0.00, 0.71); SEM = 2.5. | – | – | No |
| Ferber et al. 38 | 300 (600 limbs) | Healthy participants (50) and lower limb injury (250) | Inclinometer | IT band flexibility: SEM = 0.42°/iliopsoas flexibility: SEM = 0.55° | Not reported | – | – | No |
| Fraeulin et al. 39 | 22 | Healthy | Inertial motion capture‐digital inclinometer‐tape measure | Digital inclinometer: Rater 1 left ICC = 0.976 (0.95, 0.99); SEM = 0.9; right ICC = 0.987 (0.97, 0.99); SEM = 0.9/inertial motion capture: Rater 1 left ICC = 0.996 (0.99, 1); SEM = 0.; right ICC = 0.990 (0.98, 1); SEM = 0.7. | Digital inclinometer: left ICC = 0.87 (0.77, 0.96)/right ICC = 0.72 (0.55, 0.85). inertial motion capture: left ICC = 0.86 (0.69, 0.94)/right ICC = 0.78 (0.55, 0.90). | – | – | No |
| Sainz de Baranda et al. 40 | 20 | Healthy | Inclinometer | ICC = 0.90; no SEM; no MDC | Not reported | – | – | No |
| Cejudo et al. 41 | 90 | Healthy | Inclinometer | Testing session 2‐Testing session 1. ICC = 0.87; SEM = 2.8; MDC = 7.8/Testing session 3‐Testing session 2. ICC = 0.91; SEM = 2.2; MDC = 6.1 | Not reported | – | – | No |
| Vigotsky et al. 10 | 29 | Healthy | Infrared camera with benchmarks and motion analysis software | Not reported | Not reported | – | – | Yes |
| Hölmich et al. 25 | 18 | Groin Pain | Visual inspection | Not reported | Not reported | Right 0.83 left 0.66 mean 0.74 | Right 0.29 left 0.17 mean 0.23 | Mean of left and right side 86.4 |
| Whyte et al. 42 | 17 | Healthy | Digital goniometer on smartphone | Expert: ICC = 0.94 (0.88–0.97); SEM = 1.81; MDC = 5.0/novice: ICC = 0.94 (0.87–0.97); SEM = 1.87; MDC = 5.2 | ICC = 0.98 (0.97–0.99); SEM = 1.05; MDC = 2.9 | – | – | No |
| Clapis et al. 14 | 42 | Healthy | Goniometer and inclinometer | Examiner 1: ICC = 0.93; SEM = 1.8/Examiner 2: ICC = 0.91; SEM = 1.9. | Goniometer: ICC = 0.92; SEM = 1.9; no MDC/inclinometer ICC = 0.89; SEM = 2.1. | – | – | Yes |
| Rose‐Dulcina et al. 7 | 10 | Healthy | Goniometer and cameras for motion analysis | Within‐day: ICC = 0.937 (0.902–0.962); SEM = 2.77; MDC = 7.68/between‐day: ICC = 0.673 (0.033–0.887); SEM = 7.64; MDC = 8.45 | Within‐day: ICC = 0.939 (0.821–0.979); SEM = 2.82; MDC = 7.83 | – | – | No |
| Harvey et al. 9 | 117 | Healthy | Goniometer | ICC range = 0.91–0.94 | Not reported | – | – | No |
| Thomas test | ||||||||
| Glanzman et al. 30 | 25 | CP | Goniometer |
Rater 1: ICC = 0.977 Rater 2: ICC = 0.980 |
Not reported | – | – | No |
| Lee et al. 27 | 30 | CP | Goniometer | ICC = 0.742 (0.552–0.860); SEM = 0.590–0.830 | Not reported | – | – | No |
| Lee et al. 28 | 36 | CP | Goniometer | Patient: ICC = 0.501 (0.294–0.687); Control: ICC = 0.207 (0.021–0.423) | Not reported | – | – | No |
| Mutlu et al. 12 | 38 | CP | Goniometer | ICC = 0.926 | ICC = 0.95; ICC = 0.92 | – | – | No |
| McWhirck & Glanzman 2006 31 | 25 | CP | Goniometer | Not reported | ICC = 0.582 | – | – | No |
| Kilgour et al. 33 | 50 | CP and healthy | Goniometer | Healthy: ICC = 0.5 (0.09–0.91); CP: ICC = 0.415 (0.17–0.66) | Not reported | – | – | No |
| Cibere et al. 26 | 6 | OA | Goniometer and tape | Not reported | Hip extension ICC = 0.86 | – | – | No |
| Peeler et al. 8 | 57 | Healthy | Goniometer | ICC = 0.52; SEM = 1 | ICC = 0.60; SEM = 1 | Kappa = 0.47 | Kappa = 0.39 | Yes |
| Reactive Hip Flexor test | ||||||||
| González de la Flor et al. 6 | 26 | Healthy | Digital inclinometer |
Rater 1: ICC = 0.95; SEM = 2.01; MDC = 5.57 Rater 2: ICC = 0.97; SEM = 1.52; MDC = 4.23 |
ICC = 0.96; SEM = 1.74; MDC = 4.83 | – | – | Yes |
| Swing test | ||||||||
| Rose‐Dulcina et al. 7 | 10 | Healthy | Goniometer & Camera |
Within‐day swing ext: ICC = 0.989; SEM = 0.95; MDC = 2.65 Between‐day: ICC = 0.918; SEM = 3.05; MDC = 8.45 |
Swing ext: ICC = 0.954; SEM = 2.14; MDC = 5.95 | – | – | No |
| Falcon test | ||||||||
| Cibulka et al. 15 | 53 | Healthy | Goniometer | ICC = 0.99 (0.98–0.99) | ICC = 0.96 (0.92–0.98) | – | – | No |
Abbreviations: CP, cerebral palsy; ICC, intraclass correlation coefficient; MDC, minimal detectable change; MTT, Modified Thomas Test; OA, osteoarthritis.
Regarding reliability statistics, ICC with corresponding 95% CIs were reported in 18 studies, whereas 6 studies reported ICC without CIs. The SEM was documented in 16 studies, and MDC was reported in 11 studies. Additionally, nine studies presented Bland–Altman analysis, three studies reported percentage agreement, and four studies included Kappa or Fleiss Kappa coefficients (Table 1).
Methodological quality
Assessment of methodological quality for all included studies using the QAREL checklist is summarized in Table 2. Methodological quality ranged from 5/11 total positive ratings 11 to 11/11. 25 The mean total score across all 27 studies was 8.7/11, with a median of 9/11.
TABLE 2.
QAREL checklist risk of bias scores.
| Study | QAREL Items | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | Total | |
| Kim et al. 11 | No | Yes | Unclear | Unclear | Not applicable | Unclear | Unclear | Yes | Yes | Yes | Yes | 5 |
| Peeler et al. 5 | Yes | Yes | Yes | Yes | Unclear | Unclear | Yes | Yes | Yes | Yes | Yes | 9 |
| Wakefield et al. 29 | Yes | Yes | Yes | Yes | Not applicable | Unclear | Unclear | Yes | Yes | Yes | Yes | 8 |
| Eimiller et al. 13 | Unclear | Yes | Yes | Yes | Not applicable | Yes | Yes | No | Unclear | Yes | Yes | 7 |
| González de la Flor et al. 6 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Cibere et al. 26 | Yes | Yes | Yes | Yes | No | Unclear | Unclear | Yes | Yes | Yes | Yes | 8 |
| Cady et al. 32 | Yes | Yes | Yes | Yes | Not applicable | Unclear | Yes | Yes | Yes | Yes | Yes | 9 |
| Peeler et al. 36 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Dennis et al. 37 | Yes | Yes | Yes | Unclear | Not applicable | Unclear | Yes | Yes | Yes | Yes | Yes | 8 |
| Ferber et al. 38 | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Unclear | Yes | Yes | 10 |
| Glanzman et al. 30 | Yes | Yes | Yes | Yes | No | Unclear | Yes | No | Unclear | Yes | Yes | 7 |
| Lee et al. 27 | Yes | Yes | Yes | Yes | No | Unclear | Yes | Unclear | Unclear | Yes | Yes | 6 |
| Lee et al. 28 | Yes | Yes | Yes | Yes | No | Yes | Yes | Unclear | Unclear | Yes | Yes | 8 |
| Cibulka et al. 15 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Unclear | Yes | Yes | Yes | 9 |
| Fraeulin et al. 39 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Sainz de Baranda et al. 40 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Cejudo et al. 41 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Rose‐Dulcina et al. 7 | Yes | Yes | Yes | Unclear | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 9 |
| Peeler et al. 8 | Yes | Yes | Yes | Yes | Not applicable | Yes | Unclear | Yes | Yes | Yes | Yes | 9 |
| Vigotsky et al. 10 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | No | 9 |
| Hölmich et al. 25 | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | 11 |
| Whyte et al. 42 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | Yes | Yes | Yes | Yes | 10 |
| Clapis et al. 14 | Yes | Yes | Yes | Yes | Not applicable | Yes | Yes | No | Unclear | Yes | Yes | 8 |
| Mutlu et al. 12 | Yes | Yes | Yes | Yes | No | Yes | Yes | Unclear | Yes | Yes | Yes | 9 |
| McWhirck and Glanzman 2006 31 | Yes | Yes | Yes | Unclear | No | Yes | Yes | Unclear | Yes | Yes | Yes | 9 |
| Kilgour et al. 33 | Yes | Yes | Yes | Yes | No | Yes | Yes | No | Yes | Yes | Yes | 9 |
| Harvey et al. 9 | Yes | Yes | Unclear | Unclear | Not Applicable | Yes | Unclear | Yes | Yes | Yes | Yes | 7 |
Note: QAREL items: 1. Was the test evaluated in a sample of patients who were representative of those to whom the authors intended the results to be applied? 2. Was the test performed by raters who were representative of those to whom the authors intended the results to be applied? 3. Were raters blinded to the findings of other raters during the study? 4. Were raters blinded to their own prior findings of the test under evaluation? 5. Were raters blinded to the results of the reference standard for the target disorder (or variable) being evaluated? 6. Were raters blinded to clinical information that was not intended to be provided as part of the testing procedure or study design? 7. Were raters blinded to additional cues that were not part of the test? 8. Was the order of examination varied? 9. Was the time interval between repeated measurements compatible with the stability (or theoretical stability) of the variable being measured? 10. Was the test applied correctly and interpreted appropriately? 11. Were appropriate statistical measures of agreement used. Abbreviation: QAREL, Quality Appraisal of Reliability Studies.
Blinding of raters to the findings of other raters (QAREL item 3) was rated as “unclear” in 7 of the 27 included studies. 9 , 11 , 13 , 14 , 26 , 27 , 28 Blinding of raters to their own prior findings (item 4) was unclear in 6 studies. 9 , 11 , 14 , 29 , 30 , 31 Blinding to additional clinical information (item 6) was judged as “unclear” in 9 of the 27 studies. 5 , 9 , 11 , 26 , 27 , 28 , 29 , 30 , 32
The item related to variation in the order of examination (item 8) was rated “no” in 3 studies, 13 , 30 , 31 and as “unclear” in 6 others. 9 , 11 , 26 , 27 , 28 , 33 Only one study received a “no” rating on the use of appropriate statistical methods to assess agreement (item 11). 10
Percentage agreement among reviewers regarding the rating of methodological quality using QAREL ranged across items from 74% to 100%. The overall agreement yielded a Cohen's kappa of 0.70, indicating substantial interrater reliability. Total percentage agreement between reviewers was 89.7%.
META‐ANALYSIS RESULTS
Intrarater reliability of hip flexor flexibility tests
A random‐effects model was applied to pool the ICC and corresponding 95% CIs. The overall pooled ICC was 0.90 (95% CI, 0.85–0.95) in 888 participants, indicating excellent intrarater reliability across all the included hip flexor flexibility tests. Subgroup analyses revealed variability in ICC values among specific tests. The MTT demonstrated excellent reliability (ICC, 0.92 [95% CI, 0.89–0.95]) but exhibited substantial heterogeneity (I2 = 99%). The RHF Test showed similarly high reliability (ICC, 0.95 [95% CI, 0.92–0.98]); however, this result was based on a single study. Conversely, the Thomas Test yielded a lower ICC (0.76 [95% CI, 0.51–1.00]) accompanied by considerable heterogeneity (I2 = 100%). The Swing Test (ICC, 0.99 [95% CI, 0.98–0.99]) and Falcon Test (ICC, 0.99 [95% CI, 0.98–1.00]) also indicated excellent reliability, though each was supported by only one study. The test for subgroup differences was statistically significant (χ2 = 25.03, df = 4, p < .001), indicating that the reliability of intrarater assessments varied depending on the test used. The MTT and newer approaches like the Swing and Falcon Tests demonstrated the highest reliability. Conversely, the Thomas Test showed a lower pooled ICC and high between‐study variability, potentially reflecting methodological inconsistencies or population differences (Figure 2).
FIGURE 2.

Forest plot for intrarater ICC of hip flexor flexibility tests. CI, confidence interval; ICC, intraclass correlation coefficient.
The funnel plot (Figure 3) showed a mild asymmetry, with most studies concentrated around the overall pooled ICC value, but a few studies appeared scattered toward lower ICC values with higher SEs.
FIGURE 3.

Funnel plot for intrarater ICC of hip flexor flexibility tests. ICC, intraclass correlation coefficient.
Interrater reliability of hip flexor flexibility tests
A random‐effects model was performed to pool the ICC with corresponding 95% CI. The overall pooled ICC was 0.80 (95% CI, 0.71–0.88) in 665 participants, indicating good interrater reliability across the included tests. Subgroup analyses revealed relevant differences among specific tests. The MTT showed good reliability, with a pooled ICC of 0.86 (95% CI, 0.79–0.94). However, heterogeneity was high (I2 = 98.3%). The Thomas Test showed a pooled ICC of 0.62 (95% CI, 0.46–0.78) and considerable heterogeneity (I2 = 96.3%). The RHF Test, based on a single study, showed excellent interrater reliability (ICC, 0.96 [95% CI, 0.94–0.98]). The Swing Test also indicated excellent reliability (ICC, 0.95 [95% CI, 0.90–1.00]), supported by one study. The Falcon Test demonstrated similarly high reliability, with an ICC of 0.96 (95% CI, 0.93–0.99).
The test for subgroup differences was statistically significant (χ2 = 21.28, df = 4, p < .001), indicating that the reliability of interrater assessments varied depending on the test applied (Figure 4).
FIGURE 4.

Forest plot for interrater ICC of hip flexor flexibility tests. CI, confidence interval; ICC, intraclass correlation coefficient.
The funnel plot (Figure 5) showed moderate asymmetry. Although most studies clustered around higher ICC values, particularly near 0.90–1.00, several studies with lower precision (higher SEs) reported substantially lower ICC values.
FIGURE 5.

Funnel plot for interrater ICC of hip flexor flexibility tests. ICC, intraclass correlation coefficient.
DISCUSSION
Main findings
This systematic review and meta‐analysis included 27 studies evaluating the reliability of physical examination tests for assessing hip flexor flexibility. A total of 21 studies provided sufficient data for quantitative synthesis, comprising 18 (21 data) intrarater and 19 (24 data) interrater reliability estimates across five different tests: MTT, Thomas Test, RHF Test, Swing Test, and Falcon Test.
Meta‐analytic findings demonstrated overall excellent intrarater reliability (pooled ICC, 0.90 [95% CI, 0.85–0.95]) and good interrater reliability (pooled ICC, 0.80 [95% CI, 0.71–0.88]) across all tests. However, considerable heterogeneity was observed in both analyses (I2 > 95%), indicating significant variability across studies. Subgroup analyses revealed that newer tests such as the Falcon and Swing Tests demonstrated the highest reliability (ICC ≥0.95), although each was evaluated in a single study. The MTT, despite being the most frequently studied, exhibited variable reliability estimates and high heterogeneity, suggesting methodological inconsistencies in its application. Conversely, the Thomas Test showed the lowest pooled ICCs, raising concerns regarding its reproducibility in clinical settings.
The funnel plot for interrater data revealed moderate asymmetry, with a concentration of studies around high ICC values but a spread of smaller studies with lower precision and lower ICCs, suggesting potential small‐study effects or publication bias.
Methodological considerations and generalizability of results
Although many studies showed high ICC values, critical appraisal using the QAREL checklist revealed methodological limitations. The average quality score was 8.6/11, with a range from 5 to 11. Frequent issues included unclear reporting of examiners blinding to other raters (6/24 studies) and to their own previous ratings (5/24 studies), as well as inadequate reporting of blinding to additional clinical information (9/24 studies). Variation in the order of testing (item 8) was not consistently addressed, and only one study failed to use appropriate statistical measures (item 11).
High heterogeneity observed in the meta‐analyses, particularly for the MTT and Thomas Test, suggests differences in examiner training, test execution, population characteristics, or statistical methodology. 34 Additionally, although most studies employed validated tools such as goniometers or inclinometers, procedural inconsistencies likely contributed to variability in reliability estimates.
Only a small number of studies clearly reported blinding procedures, rater experience, or standardization protocols, factors known to influence reliability outcomes. Furthermore, none of the studies conducted a priori sample size calculations, which limits the statistical power and interpretability of their findings.
Although high ICC values suggest strong reproducibility, this does not inherently confirm the validity of the tests. A reliable test may consistently reproduce measurements yet still fail to measure the true flexibility of the hip flexors if it is influenced by confounding variables such as pelvic tilt or contralateral limb control. 10 Hence, results should be interpreted with caution, particularly for tests like the Thomas Test, where methodological challenges are more prominent.
Implications for clinical practice and future research
This review highlights the need for improved standardization and methodological rigor in the evaluation of hip flexor flexibility tests. Clinicians should be cautious when interpreting results from tests with known sources of variability, such as the MTT and Thomas Test, and consider using more standardized or recently developed tests (eg, Falcon Test) when feasible. Future studies should focus on multicenter designs with standardized training protocols, rigorous blinding, and prospective trial registration. The use of tools like Guidelines for Reporting Reliability and Agreement Studies is strongly encouraged to enhance transparency and reproducibility. 35
It is also recommended that future studies include a priori sample size calculations and report full reliability statistics, including SEM and MDC, to allow for better interpretation of clinical relevance. Finally, the clinical utility of flexibility tests should be explored in the context of validity studies and their association with performance or injury risk, especially in athletic or symptomatic populations.
Limitations
The findings of this review must be interpreted considering certain limitations. High between‐study heterogeneity may have inflated or obscured pooled ICC estimates. The inclusion of studies with unclear blinding may have affected reliability estimates. Finally, although no language restrictions were applied, gray literature and unpublished data were not included, raising the possibility of publication bias.
CONCLUSION
This systematic review and meta‐analysis provide a comprehensive synthesis of the reliability of physical examination tests used to assess hip flexor flexibility. Overall, these tests demonstrated good‐to‐excellent intrarater and interrater reliability, with pooled ICCs of 0.90 and 0.80, respectively. However, substantial methodological heterogeneity was present, particularly in the application and interpretation of the MTT and Thomas Test. Newer assessments such as the RHF, Falcon, and Swing Tests showed high reliability, although further validation is warranted.
FUNDING INFORMATION
This research received no specific grant from any funding agency in the public, commercial, or not‐for‐profit sectors. The authors have not received any financial support for the conduct of this study or preparation of this manuscript.
DISCLOSURE
The authors declare no conflicts of interest related to the content of this manuscript. The authors have no financial or personal relationships with individuals or organizations that could have influenced the work reported in this paper.
PERMISSION TO REPRODUCE MATERIAL FROM OTHER SOURCES
All third‐party material used in this manuscript has been appropriately cited and credited. No copyrighted material was reproduced without the necessary permissions.
Supporting information
Appendix: Supporting Information.
DATA AVAILABILITY STATEMENT
The data supporting the findings of this study are available within the article and its supplementary materials. Additional data, including extracted datasets for the meta‐analysis, can be made available upon reasonable request to the corresponding author.
REFERENCES
- 1. Reiman MP, Thorborg K. Clinical examination and physical assessment of hip joint‐related pain in athletes. Int J Sports Phys Ther. 2014;9:737‐755. [PMC free article] [PubMed] [Google Scholar]
- 2. Neumann DA. Kinesiology of the hip: A focus on muscular actions. J Orthop Sports Phys Ther. 2010;40:82‐94. doi: 10.2519/jospt.2010.3025 [DOI] [PubMed] [Google Scholar]
- 3. Mills M, Frank B, Goto S, et al. Effect of restricted hip flexor muscle length on hip extensor muscle activity and lower extremity biomechanics in college‐aged female soccer players. Int J Sports Phys Ther. 2015;10(7):946‐954. [PMC free article] [PubMed] [Google Scholar]
- 4. Konrad A, Močnik R, Titze S, Nakamura M, Tilp M. The influence of stretching the hip flexor muscles on performance parameters. A systematic review with meta‐analysis. Int J Environ Res Public Health. 2021;18(4):1936. doi: 10.3390/IJERPH18041936 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Peeler JD, Anderson JE. Reliability limits of the modified Thomas test for assessing rectus femoris muscle flexibility about the knee joint. J Athl Train. 2008;43:470‐476. doi: 10.4085/1062-6050-43.5.470 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. González‐de‐la‐Flor Á, García‐Pérez‐de‐Sevilla G, Domínguez‐Balmaseda D, del‐Blanco‐Muñiz JÁ. Validity and reliability of a new hip flexor muscles flexibility assessment tool: the reactive hip flexor (RHF) test. Phys Ther Sport. 2023;64:41‐47. doi: 10.1016/j.ptsp.2023.09.002 [DOI] [PubMed] [Google Scholar]
- 7. Rose‐Dulcina K, Vassant C, Lauper N, Dominguez DE, Armand S. The SWING test: A more reliable test than passive clinical tests for assessing sagittal plane hip mobility. Gait Posture. 2022;92:77‐82. doi: 10.1016/j.gaitpost.2021.11.014 [DOI] [PubMed] [Google Scholar]
- 8. Peeler J, Anderson JE. Reliability of the Thomas test for assessing range of motion about the hip. Phys Ther Sport. 2007;8:14‐21. doi: 10.1016/j.ptsp.2006.09.023 [DOI] [Google Scholar]
- 9. Harvey D. Assessment of the flexibility of elite athletes using the modified Thomas test. Br J Sports Med. 1998;32:68‐70. doi: 10.1136/bjsm.32.1.68 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Vigotsky AD, Lehman GJ, Beardsley C, Contreras B, Chung B, Feser EH. The modified Thomas test is not a valid measure of hip extension unless pelvic tilt is controlled. PeerJ. 2016;4:e2325. doi: 10.7717/peerj.2325 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Kim G‐M, Ha S‐M. Reliability of the modified Thomas test using a lumbo‐plevic stabilization. J Phys Ther Sci. 2015;27:447‐449. doi: 10.1589/jpts.27.447 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Mutlu A, Livanelioglu A, Gunel MK. Reliability of goniometric measurements in children with spastic cerebral palsy. Med Sci Monit. 2007;13:CR323‐CR329. [PubMed] [Google Scholar]
- 13. Eimiller K, Stoddard E, Janes B, Smith M, Vincek A. Reliability of goniometric techniques for measuring hip flexor length using the Modified Thomas Test. Int J Sports Phys Ther. 2024;19:997‐1002. doi: 10.26603/001c.120899 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Clapis PA, Davis SM, Davis RO. Reliability of inclinometer and goniometric measurements of hip extension flexibility using the modified Thomas test. Physiother Theory Pract. 2008;24:135‐141. doi: 10.1080/09593980701378256 [DOI] [PubMed] [Google Scholar]
- 15. Cibulka MT, Wunderlich P, Klockenga H, Reed A, Sandman J. The falcon test: an observer agreement study in subjects with and without anterior knee pain. Int J Sports Phys Ther. 2023;18:368‐374. doi: 10.26603/001c.73190 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155‐163. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Mokkink LB, Terwee CB, Patrick DL, et al. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010;19:539‐549. doi: 10.1007/s11136-010-9606-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Hopkins WG. Measures of reliability in sports medicine and science. Sports Med. 2000;30:1‐15. doi: 10.2165/00007256-200030010-00001 [DOI] [PubMed] [Google Scholar]
- 19. Hopkins WG, Marshall SW, Batterham AM, Hanin J. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. 2009;41:3‐12. doi: 10.1249/MSS.0b013e31818cb278 [DOI] [PubMed] [Google Scholar]
- 20. Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. doi: 10.1136/bmj.n71 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Lucas NP, Macaskill P, Irwig L, Bogduk N. The development of a quality appraisal tool for studies of diagnostic reliability (QAREL). J Clin Epidemiol. 2010;63:854‐861. doi: 10.1016/j.jclinepi.2009.10.002 [DOI] [PubMed] [Google Scholar]
- 22. Deeks JJ, Higgins JP, Altman DG, Cochrane Statistical Methods Group . Analysing data and undertaking meta‐analyses. Cochrane Handbook for Systematic Reviews of Interventions. Wiley; 2019:241‐284. [Google Scholar]
- 23. Schwarzer G, Carpenter JR, Rücker G. Meta‐Analysis with R. Springer International Publishing; 2015. [Google Scholar]
- 24. Deeks J, Altman DG, Bradburn MJ. Statistical methods for examining heterogeneity and combining results from several studies in meta‐analysis. In: Egger M, Smith GD, Altman DG, eds. Systematic Reviews in Health Care. 2nd ed. BMJ Books; 2001. [Google Scholar]
- 25. Hölmich P, Hölmich LR, Bjerg AM. Clinical examination of athletes with groin pain: an intraobserver and interobserver reliability study. Br J Sports Med. 2004;38:446‐451. doi: 10.1136/bjsm.2003.004754 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Cibere J, Thorne A, Bellamy N, et al. Reliability of the hip examination in osteoarthritis: Effect of standardization. Arthritis Care Res. 2008;59:373‐381. doi: 10.1002/art.23310 [DOI] [PubMed] [Google Scholar]
- 27. Lee KM, Lee J, Chung CY, et al. Pitfalls and important issues in testing reliability using intraclass correlation coefficients in orthopaedic research. Clin Orthop Surg. 2012;4:149. doi: 10.4055/cios.2012.4.2.149 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. Lee KM, Chung CY, Kwon DG, Han HS, Choi IH, Park MS. Reliability of physical examination in the measurement of hip flexion contracture and correlation with gait parameters in cerebral palsy. J Bone Joint Surg Am. 2011;93(2):150‐158. doi: 10.2106/JBJSJ.00252 [DOI] [PubMed] [Google Scholar]
- 29. Wakefield CB, Halls A, Difilippo N, Cottrell GT. Reliability of goniometric and trigonometric techniques for measuring hip‐extension range of motion using the modified Thomas test. J Athl Train. 2015;50:460‐466. doi: 10.4085/1062-6050-50.2.05 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Glanzman AM, Swenson AE, Kim H. Intrarater range of motion reliability in cerebral palsy: A comparison of assessment methods. Pediatr Phys Ther. 2008;20:369‐372. doi: 10.1097/PEP.0b013e31818b7994 [DOI] [PubMed] [Google Scholar]
- 31. McWhirk LB, Glanzman AM. Within‐session inter‐rater realiability of goniometric measures in patients with spastic cerebral palsy. Pediatr Phys Ther. 2006;18:262‐265. doi: 10.1097/01.pep.0000234960.88761.97 [DOI] [PubMed] [Google Scholar]
- 32. Cady K, Powis M, Hopgood K. Intrarater and interrater reliability of the modified Thomas test. J Bodyw Mov Ther. 2022;29:86‐91. doi: 10.1016/j.jbmt.2021.09.014 [DOI] [PubMed] [Google Scholar]
- 33. Kilgour G, McNair P, Stott NS. Intrarater reliability of lower limb sagittal range‐of‐motion measures in children with spastic diplegia. Dev Med Child Neurol. 2003;45:391‐399. doi: 10.1111/j.1469-8749.2003.tb00418.x [DOI] [PubMed] [Google Scholar]
- 34. Higgins JPT, Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta‐analyses. BMJ. 2003;327:557‐560. doi: 10.1136/bmj.327.7414.557 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Kottner J, Audigé L, Brorson S, et al. Guidelines for reporting reliability and agreement studies (GRRAS) were proposed. J Clin Epidemiol. 2011;64:96‐106. doi: 10.1016/j.jclinepi.2010.03.002 [DOI] [PubMed] [Google Scholar]
- 36. Peeler J, Leiter J. Using digital photography to document rectus femoris flexibility: A reliability study of the modified Thomas test. Physiother Theory Pract. 2013;29:319‐327. doi: 10.3109/09593985.2012.731140 [DOI] [PubMed] [Google Scholar]
- 37. Dennis RJ, Finch CF, Elliott BC, Farhart PJ. The reliability of musculoskeletal screening tests used in cricket. Phys Ther Sport. 2008;9:25‐33. doi: 10.1016/j.ptsp.2007.09.004 [DOI] [PubMed] [Google Scholar]
- 38. Ferber R, Kendall KD, McElroy L. Normative and critical criteria for iliotibial Band and iliopsoas muscle flexibility. J Athl Train. 2010;45:344‐348. doi: 10.4085/1062-6050-45.4.344 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39. Fraeulin L, Holzgreve F, Brinkbäumer M, et al. Intra‐ and inter‐rater reliability of joint range of motion tests using tape measure, digital inclinometer and inertial motion capturing. PLoS One. 2020;15:e0243646. doi: 10.1371/journal.pone.0243646 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40. de Baranda PS, Cejudo A, Ayala F, Santonja F. Perfil óptimo de flexibilidad del miembro inferior en jugadoras de fútbol sala. Rev Int Med Cienc Act Fis Deporte. 2015;15(60):647‐662. doi: 10.15366/rimcafd2015.60.003 [DOI] [Google Scholar]
- 41. Cejudo A, Sainz de Baranda P, Ayala F, Santonja F. Test‐retest reliability of seven common clinical tests for assessing lower extremity muscle flexibility in futsal and handball players. Phys Ther Sport. 2015;16:107‐113. doi: 10.1016/j.ptsp.2014.05.004 [DOI] [PubMed] [Google Scholar]
- 42. Whyte E, Ó Doinn T, Downey M, O'Connor S. Reliability of a smartphone goniometric application in the measurement of hip range of motion among experienced and novice clinicians. J Sport Rehabil. 2021;30:969‐972. doi: 10.1123/JSR.2020-0165 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Appendix: Supporting Information.
Data Availability Statement
The data supporting the findings of this study are available within the article and its supplementary materials. Additional data, including extracted datasets for the meta‐analysis, can be made available upon reasonable request to the corresponding author.
