Mass conversion efficiency, Energy reduction, heat recovery and preheating temperature of the current investigation.

Plasma temperature in ⁰C Feedstock rate in kg/h Mass conversion efficiency in % Energy reduction in % Recovered heat in kJ/h Preheating temperature in ⁰C
1500 15 60 45.1 16,236 902
2000 15 69.82 53.4 19,224 1068
2500 15 78.58 60.3 21,708 1206