Skip to main content
. 2026 Jul 13;16:1867715. doi: 10.3389/fonc.2026.1867715

Table 2.

Comparison of preoperative and postoperative dosimetry parameters.

Parameter 120–140 Gy 140–160 Gy
Preoperative Postoperative P* Preoperative Postoperative P*
D90 (Gy) 129.2 (120.0–138.4) 128.8 (114.6–139.2) 0.465 150.0 (140.7–174.0) 149.3 (140.0–179.4) 0.546
V100 (%) 91.8 ± 1.2 91.7 ± 1.2 0.438 92.3 ± 1.5 92.2 ± 1.8 0.743
CI 0.76 (0.63–0.81) 0.76 (0.62–0.81) 0.265 0.75 (0.61–0.84) 0.75 (0.61–0.83) 0.442
EI (%) 21.1 (7.0–31.5) 21.8 (6.8–38.9) 0.223 22.0 (5.3–36.0) 23.2 (4.9–38.2) 0.272

Data are presented as median (range) for non-normally distributed variables and mean ± SD for normally distributed variables.