Prolonged veno arterial extracorporeal bypass (50-80% of cardiac output) was evaluated in normal, unanesthetized sheep. The evaluation protocol included serial measurements of hemodynamics, pulmonary and renal function, serum enzymes to detect organ damage, and detailed studies of coagulation and platelets. Blood exposure surfaces were primarily polyvinyl chloride and silicone rubber. Gas interfaces were carefully excluded with the exception of four experiments utilizing bubble oxygenators. Heparin dose was titrated to maintain activated clotting to two to three times baseline. Characteristics of 48 hour uncomplicated extracorporeal circulation in 8 sheep included normal hemodynamics, mild respiratory alkolosis negligable hemolysis, slight gradual increase in heart, liver, and muscle enzymes. The most significant changes occurred in coagulation and platelets characterized by an initial reduction in coagulation factors with a continued reduction in platelet count and return to normal clotting factors during extracorporeal circulation. This is followed by a two times normal increase in platelets and fibrinogen following extracorporeal circulation.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- BLIX S. Studies on the fibrinolytic system in the euglobulin fraction of human plasma. A. Methodological study. B. Application of the methods. Scand J Clin Lab Invest. 1961;13 (Suppl 58):3–19. [PubMed] [Google Scholar]
- Bartlett R. H., Drinker P. A., Burns N. E., Fong S. W., Hyans T. The toroidal membrane oxygenator: design, performance, and prolonged bypass testing of a clinical model. Trans Am Soc Artif Intern Organs. 1972;18(0):369–374. [PubMed] [Google Scholar]
- Bartlett R. H., Isherwood J., Moss R. A., Olszewski W. L., Polet H., Drinker P. A. A toroidal flow membrane oxygenator: four day partial bypass in dogs. Surg Forum. 1969;20:152–153. [PubMed] [Google Scholar]
- GALLETTI P. M. LABORATORY EXPERIENCE WITH 24 HOUR PARTIAL HEART-LUNG BYPASS. J Surg Res. 1965 Mar;5:97–104. doi: 10.1016/s0022-4804(65)80001-4. [DOI] [PubMed] [Google Scholar]
- Gajewski J., Povar M. L. Blood coagulation values of sheep. Am J Vet Res. 1971 Mar;32(3):405–409. [PubMed] [Google Scholar]
- Gazzaniga A. B., Byrd C. L., Stewart D. R., Gross R. E. Effects of dexamethasone and chlorpromazine on skeletal muscle surface hydrogen ion concentration during cardiopulmonary bypass: experimental and clinical results. Ann Surg. 1972 Dec;176(6):757–760. doi: 10.1097/00000658-197212000-00015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hanson E. L., Bartlett R. H., Burns N. E., Shults M. C., LaCava E. J., Polet H., Drinker P. A. Prolonged use of a membrane oxygenator in air-breathing and hypoxic lambs. I. Venovenous bypass. Surgery. 1973 Feb;73(2):284–298. [PubMed] [Google Scholar]
- Hardisty R. M., Hutton R. A. Platelet aggregation and the availability of platelet factor 3. Br J Haematol. 1966 Nov;12(6):764–776. doi: 10.1111/j.1365-2141.1966.tb00164.x. [DOI] [PubMed] [Google Scholar]
- Hicks R. E., Dutton R. C., Ries C. A., Price D. C., Edmunds L. H., Jr Production and fate of platelet aggregate emboli during venovenous perfusion. Surg Forum. 1973;24:250–252. [PubMed] [Google Scholar]
- Hill J. D. Extracorporeal oxygenation for acute respiratory insufficiency: clinical experience. Mt Sinai J Med. 1973 Mar-Apr;40(2):189–198. [PubMed] [Google Scholar]
- Hill J. D., O'Brien T. G., Murray J. J., Dontigny L., Bramson M. L., Osborn J. J., Gerbode F. Prolonged extracorporeal oxygenation for acute post-traumatic respiratory failure (shock-lung syndrome). Use of the Bramson membrane lung. N Engl J Med. 1972 Mar 23;286(12):629–634. doi: 10.1056/NEJM197203232861204. [DOI] [PubMed] [Google Scholar]
- Peirce E. C., 2nd A comparison of the Landé-Edwards, the Peirce, and the General Electric-Peirce membrane lungs. Trans Am Soc Artif Intern Organs. 1970;16:358–364. [PubMed] [Google Scholar]
- SALZMAN E. W. MEASUREMENT OF PLATELET ADHESIVENESS. A SIMPLE IN VITRO TECHNIQUE DEMONSTRATING AN ABNORMALITY IN VON WILLEBRAND'S DISEASE. J Lab Clin Med. 1963 Nov;62:724–735. [PubMed] [Google Scholar]
- Soeter J. R., Mamiya R. T., Sprague A. Y., McNamara J. J. Prolonged extracorporeal oxygenation for cardiorespiratory failure after tetralogy correction. J Thorac Cardiovasc Surg. 1973 Aug;66(2):214–218. [PubMed] [Google Scholar]
- Stiehm E. R., Clatanoff D. V. Split products of fibrin in the serum of newborns. Pediatrics. 1969 May;43(5):770–780. [PubMed] [Google Scholar]
- Welbourn N., Melrose D. G., Moss D. W. Changes in serum enzyme levels accompanying cardiac surgery with extracorporeal circulation. J Clin Pathol. 1966 May;19(3):220–232. doi: 10.1136/jcp.19.3.220. [DOI] [PMC free article] [PubMed] [Google Scholar]
- de Leval M., Hill J. D., Mielke H., Bramson M. L., Smith C., Gerbode F. Platelet kinetics during extracorporeal circulation. Trans Am Soc Artif Intern Organs. 1972;18(0):355–358. doi: 10.1097/00002480-197201000-00088. [DOI] [PubMed] [Google Scholar]