Abstract

A microbial evaluation was made of adhesive plastic surgical drapes and cloth surgical drapes. These studies were done both during surgery and in the laboratory. The plastic drape does not allow bacterial penetration, lateral migration does not occur, skin bacteria do not multiply under the drape within the time periods studied and the patient drapes are held in place with their use. When wet, cloth drapes showed profuse bacterial penetration. Dry cloth showed less bacterial penetration as compared to wet cloth. Lateral migration under cloth drapes was not possible to assess due to a high level of penetration. The surface of cloth showed a higher level of bacterial contamination during the surgical procedures. Deep wound cultures collected just prior to closing showed 60% contamination when cloth was used compared to 6% when plastic was employed. The micro-organisms recovered from the various sites sampled were identified. Finally, in addition to the positive aseptic benefits afforded by plastic adhesive drapes, aesthetic features such as a more delineated operative field and elimination of towel clips make this product a useful adjunct to the surgeon's armamentarium.

Full text

PDF
49

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BECK W. C., CARLSON W. W. ASEPTIC BARRIERS. Arch Surg. 1963 Aug;87:288–296. doi: 10.1001/archsurg.1963.01310140096017. [DOI] [PubMed] [Google Scholar]
  2. Dineen P. Penetration of surgical draping material by bacteria. Hospitals. 1969 Oct 1;43(19):82–85. [PubMed] [Google Scholar]
  3. HALL L. B., HARTNETT M. J. MEASUREMENT OF THE BACTERIAL CONTAMINATION ON SURFACES IN HOSPITALS. Public Health Rep. 1964 Nov;79:1021–1024. [PMC free article] [PubMed] [Google Scholar]
  4. Hart J. B., French M. L., Eitzen H. E., Ritter M. A. Rodac plate-holding device for sampling surfaces during surgery. Appl Microbiol. 1973 Sep;26(3):417–418. doi: 10.1128/am.26.3.417-418.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Stephenson D. V., Jr, Schelble J. F., Davis W. C., Weber C. L. A new nonporous surgical drape. Surg Gynecol Obstet. 1969 Aug;129(2):353–356. [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins