Skip to main content
. 2026 Jul 29;8:1900115. doi: 10.3389/fdgth.2026.1900115

Table 7.

Effect of SVEB-aware calibration on classification performance.

Decision rule Accuracy Macro-F1 SVEB precision SVEB recall SVEB F1
Argmax baseline 94.14% 72.52% 48.80% 34.42% 40.37%
SVEB-calibrated 94.15% 74.53% 48.50% 43.95% 46.11%

Calibration parameters were selected on the validation set and evaluated on the held-out test set.

Bold values indicate the metrics that improved after applying the selected SVEB-aware calibration compared with the argmax baseline.