Evaluation of the Seating of Crowns After Adjusting Proximal Contacts Using Different Materials

Mitali Ashwin Jain 1, Krishna Prasad D 1,✉
PMCID: PMC13471955  PMID: 42104713

ABSTRACT

Objective

Achieving physiologic proximal contact is essential for complete crown seating and long‐term periodontal health. Improper adjustment can result in tight or open contacts, leading to incomplete seating, marginal discrepancies, food impaction, and discomfort. This study evaluated the seating accuracy of posterior single‐unit porcelain fused to metal (PFM) crowns after proximal contact adjustment using different contact‐indicating methods.

Clinical Considerations

In this prospective randomized clinical study, 124 patients requiring posterior single‐unit PFM crowns were randomly allocated into four groups (n = 31 each): Artifol (8 μm), articulating paper (40 μm), Arti‐Spot (3 μm), and visual acuity alone. Proximal contacts were adjusted during laboratory procedures according to the assigned method. At clinical try‐in, seating was considered “perfect” if no further proximal adjustment was required. Intraoral periapical radiographs confirmed crown seating. Data were analyzed using Fisher's exact tests (p < 0.05).

Conclusion

A significant association was observed between adjustment method and crown seating (p = 0.000). Arti‐Spot demonstrated the highest number of perfectly seated crowns (29/31), whereas visual assessment showed the poorest results. Thin contact‐indicating materials demonstrated more consistent outcomes in immediate chairside proximal contact assessment compared to other methods.

1. Introduction

The interproximal relationship refers to the association between adjacent teeth within the same dental arch, specifically describing the contact and spatial relationship between the mesial surface of one tooth and the distal surface of the neighboring tooth. These contact points play a crucial role in maintaining health, function, and comfort of the stomatognathic system of the patient. Proper contacts are critical for various reasons such as preventing food impaction, maintaining alignment of teeth within the arch and additionally, supporting the health of the periodontium [1].

While often overlooked in routine practice, the integrity of these contact points is essential for preventing a cascade of clinical complications. During crown fabrication and delivery, achieving ideal proximal contact remains a clinical challenge. Inadequate or improper contacts, whether excessively tight or open, can lead to clinical complications such as marginal discrepancies, incomplete seating of crowns, gingival inflammation, caries in adjacent teeth, and patient discomfort [2]. Despite their clinical significance, there is no universally accepted quantitative definition of “ideal” proximal contact tightness, and clinicians largely rely on subjective methods during chairside evaluation. Several methods are commonly employed to assess and adjust proximal contacts, including dental floss, shimstock foil, articulating paper, articulating films such as Arti‐Spot, diamond strips, and visual inspection [3]. However, studies have demonstrated that floss, although widely used, is unreliable and inconsistent in detecting contact discrepancies, particularly those that interfere with complete crown seating. More objective materials such as shimstock and articulating films have been shown to provide greater accuracy and reproducibility in evaluating proximal contact strength [3]. Dental floss “snaps” through contacts to assess tension, while shimstock checks resistance and marks tight spots. Articulating paper or Arti‐Spot reveal contact points via visible marks on proximal surfaces. Previous investigations have highlighted the clinical consequences of faulty proximal contacts. One study demonstrated that proximal contact strength varies significantly between teeth, arches, and functional conditions, making clinical assessment challenging [4]. Other studies have reported a high prevalence of unacceptable proximal contacts in fixed prostheses, with tight contacts being more common than open ones and frequently associated with over‐contoured restorations, compromised oral hygiene, and increased caries risk.

Despite available evidence, there remains limited consensus regarding the most reliable material or method for proximal contact adjustment that ensures optimal crown seating. Most existing studies focus on contact evaluation rather than the direct effect of different adjustment materials on crown seating. Therefore, this study aims to evaluate the seating of crowns after proximal contact adjustment using different materials, thereby providing clinically relevant data to guide prosthodontic practice and improve the long‐term success of single‐unit fixed restorations.

2. Aim

To evaluate the seating of the crowns after adjusting proximal contacts using different materials.

3. Objectives

  • To evaluate the seating of the crown after adjusting proximal contacts using different materials.

  • Compare the accuracy of different materials in adjusting proximal contacts.

Null Hypothesis

There is no significant difference in seating of crown after adjusting proximal contacts using different materials.

Alternative Hypothesis

There is significant difference in seating of crown after adjusting proximal contacts using different materials.

4. Materials and Method

The present study is designed as an in vivo randomized comparative prospective study to evaluate the seating of posterior single‐unit porcelain fused to metal (PFM) crowns after proximal contact adjustment using different methods. A total of 124 patients reporting to the outpatient Department of Prosthodontics and Crown & Bridge of Nitte (Deemed to be university), AB Shetty Memorial Institute of Dental Sciences, Mangaluru, Karnataka, India and requiring replacement of a single posterior molar tooth with a PFM crown were selected for the study. Written informed consent was obtained from all participants prior to their inclusion in this institutional review board approved study. (Ref no. ETHICS/ABSMIDS/599/2025).

4.1. Sample Size Estimation

Sample size estimation was performed using G*Power software (version 3.1.9.4), based on 5% level of significance, effect size 0.3, power: 80% for four materials and outcome recorded “SEATED OR NOT SEATED” for 3 degrees of freedom. Accordingly, a sample size of 124 was considered, with 31 in each group.

4.2. Inclusion Criteria

  • Patients aged 18 years and above

  • Patients with good oral hygiene and healthy periodontium.

  • Patients requiring single‐unit PFM crown in the molar region with intact adjacent teeth on both anterior and posterior aspects.

  • Adjacent teeth (mesial and distal) free from caries and restorations

  • Opposing tooth free from caries and prosthesis.

  • Patients are willing to comply with the treatment protocol and provide informed consent.

4.3. Exclusion Criteria

  • Absence of adjacent or opposing teeth.

  • Adjacent teeth with existing prosthesis or caries.

  • Malaligned adjacent teeth.

  • Generalized spacing.

  • Patients with compromised periodontal health.

4.4. Methodology

The selected subjects were randomly allocated into four groups (n = 31 per group) based on the method used for proximal contact adjustment during crown fabrication. The baseline characteristics of the study participants are presented in Table 1, and the study design is illustrated in Figure 1.

  • Group I: Bausch Artispot (3 μm thickness).

  • Group II: Bausch Artifol (8 μm thickness).

  • Group III: Bausch Articulating paper (40 μm thickness).

  • Group IV: Visual acuity (operator judgment alone).

TABLE 1.

Baseline characteristics of the study participants.

Visual acuity Artispot Artifol Articulating paper
Number of Patients 31 31 31 31
Age 18–64 years 18–53 years 19‐55 years 20‐59 years
Gender

Males‐20

Females‐11

Males‐18

Females‐13

Males‐12

Females‐19

Males‐9

Females‐22

Arch

mandibular arch‐15

maxillary arch‐16

mandibular arch‐8

maxillary arch‐23

mandibular arch‐21

maxillary arch‐10

mandibular arch‐12

maxillary arch‐19

Intact Anterior and Posterior Tooth Yes Yes Yes Yes

FIGURE 1.

FIGURE 1

Flowchart for the study design.

Participants were randomly assigned to four groups using a computer‐generated randomization sequence generated with an online software named Research Randomizer. The sequence was prepared prior to the commencement of the study and exported as an Excel sheet specifying group allocation for each participant. At the time of patient recruitment, the operator referred to this list to determine group assignment. As the allocation sequence was accessible during enrollment, allocation concealment was not performed. All proximal contact adjustments were carried out in the laboratory by the primary investigator according to the assigned group. However, the seating of the crown and adequacy of proximal contacts were evaluated by a second independent clinician who was blinded to the group allocation and the material used, thereby minimizing assessment bias.

Tooth preparation of the selected tooth was carried out following the standardized biomechanical principles. It was ensured that no adjacent tooth was nicked during the tooth preparation. Gingival retraction was performed as required. Final impression was recorded using elastomeric impression material and temporization of the tooth was done. Following this Porcelain fused to metal (PFM) crown was fabricated using standardized laboratory protocols to minimize variability.

After the fabrication, proximal contacts were adjusted in the laboratory on a cast by a single operator, a senior postgraduate resident in Prosthodontics with prior clinical experience in fixed prosthodontic procedures as per the allocated groups. All adjustments were performed following a standardized protocol to minimize operator related bias:

  • Bausch Arti‐Spot: A highspot‐indicator which can be applied with brush, is a solvent that evaporates in seconds, leaving a thin film 3 μm thick as shown in Figure 2A. High points can be easily detected as it destroys the color skin exactly at the point of contact as illustrated in Figure 2B. Contact points were adjusted based on precise spot markings. The adjusted crown on the cast is shown in Figure 2C.

  • Bausch Artifol (Articulating film ultra‐thin‐8 μm): Contacts adjusted until artifol passes with slight resistance.

    Artifol is a polyester articulating film of 8‐μm thickness. If artifol bound or torn during withdrawal, the contact was deemed excessively tight and unacceptable. If it passed freely without contacting adjacent teeth, the contact was considered open and unacceptable. Contacts that allowed passage with slight resistance, without binding, were classified as acceptable as illustrated in Figure 3.

  • Bausch Articulating paper (Articheck micro‐thin 40‐μm): Contacts adjusted based on marking intensity. Small, sharp point indicated ideal and precise contact. Bullseye mark, larger and darker marks implied heavier contacts. No mark of the dye on the crown or adjacent tooth indicated open contact. Assessment of proximal contacts using articulating paper is shown in Figure 4.

  • Visual acuity: Contacts adjusted solely by technician's visual judgment. Proximal contact assessment on the cast demonstrated complete seating of the crown in the laboratory as depicted in Figure 5A, while its evaluation in the oral cavity demonstrated tight proximal contacts leading to an unseated crown exhibiting marginal discrepancy as shown in Figure 5B.

FIGURE 2.

FIGURE 2

(A) Represents application of Artispot on the proximal surface of crown using a brush. (B) The arrow in the figure indicates the highspot marked by the indicator on the proximal surface of the crown. (C) The image shows a crown adjusted by Artispot in the laboratory on a cast.

FIGURE 3.

FIGURE 3

Evaluation of proximal contacts using Artifol.

FIGURE 4.

FIGURE 4

Evaluation of proximal contacts using Articulating paper.

FIGURE 5.

FIGURE 5

(A) Evaluation of the proximal contact by visual acuity on cast showing complete seating of the crown in laboratory. (B) Evaluation of the proximal contact by visual acuity in the oral cavity of the same crown shows tight proximal contacts leading to unseated crown.

Once the proximal contact adjustment was done, at the clinical try‐in appointment, crown seating was evaluated before final cementation. The following parameters were assessed during the try‐in:

  • The crown seated completely without resistance.

  • Proximal contacts were ideally tight.

  • No additional proximal trimming or ceramic addition was required.

  • Overextending margins or casting blebs are not present.

  • No rocking of crown due to binding to the prepared tooth.

  • No marks on the internal surface of the crown verified using disclosing wax or aerosol sprays to check if the crown is binding.

If the crown seated fully without any need for proximal modification, it was considered “perfectly seated” and marked as a successful outcome. Improper proximal contact, whether excessively tight or inadequately loose, serves as an indicator that the crown is not fully or correctly seated. If the crown was too tight, proximal trimming was performed. If the crown was too loose, ceramic was added, and the crown was re‐adjusted. But the contact status was recorded before corrective modification.

Following clinical seating, an intraoral periapical radiograph (IOPA) was taken for each crown. Before cementation of the single crown, an IOPA was evaluated for complete seating of the crown, ensuring no radiolucent gap exists between the restoration and tooth; marginal adaptation, with margins appearing continuous and well‐adapted without open gaps or overhangs and over contoured proximal contacts/contours, to rule out improper contact causing seating issues. Additionally, the underlying tooth should be assessed for residual caries or structural defects, and the periapical status must be checked for a healthy periodontal ligament space, intact lamina dura, and absence of pathology. Two intraoral periapical radiographs are shown in Figure 6A,B. The arrow marked as 1 in Figure 6A indicates an excessive proximal contouring with a proximal overhang. In Figure 6B, the arrow marked as 1 shows open interproximal contacts, the arrow marked as 2 indicates an incompletely seated crown with resultant marginal misfit, and the arrow marked as 3 shows periradicular pathology. The primary outcome measured was the number of crowns that seated perfectly without requiring any proximal adjustment before corrective modification.

FIGURE 6.

FIGURE 6

Shows two intraoral periapical radiographs (A) The arrow marked as 1 shows an over‐contoured proximal contact and overhangs in the crown. (B) The arrow marked as 1 shows open proximal contacts, the arrow marked as 2 shows an unseated crown at the margins leading to open gaps, and the arrow marked 3 shows a periapical pathology.

Final verification of crown seating was performed using dental floss; a distinct ‘snap’ upon passage through the contact was considered indicative of optimal proximal contact and complete seating, whereas resistance (tight contact) or free passage (open contact) was deemed unacceptable.

4.5. Statistical Analysis

Statistical software SPSS version 29 was used to analyze the data. Fisher's exact test was used to assess the crown fit and p < 0.05 was considered statistically significant. Fisher's exact test is used for small sample sizes or when > 20% of expected cell counts are < 5, providing an exact p‐value based on hypergeometric distribution. Chi‐square tests are preferred for larger sample sizes. Hence Fisher's exact test was chosen.

5. Results

A total of 124 contacts were evaluated using four methods: visual acuity, Artispot, Artifol, and articulating paper (31 samples per group). A significant association was observed between the methods of evaluation. The distribution of crown seating outcomes across study groups is presented in Table 2.

TABLE 2.

Shows distribution of crown seating outcomes across study groups.

Contact * Group crosstabulation
Count
Groups Total
Visual acuity Artispot Artifol Articulating paper
Contacts Not seated (Tight proximal contacts) 16a 2b 5b 6b 29
Not seated (Open proximal contacts) 7a 0b 3a,b 8a 18
Perfectly seated 8a 29b 23c 17c 77
Total 31 31 31 31 124

Each subscript letter denotes a subset of Group categories whose column proportions do not differ significantly from each other at the 0.05 level.

Overall, there is a statistically significant difference between all the four groups in detecting the contacts. The association between contact status and study groups analyzed using Fisher's exact test is presented in Table 3.

  1. “Tight” Contacts
    • Visual Acuity: This method identified a significantly higher number of “Tight” contacts (16 out of 31) compared to all other methods.
    • The Aids (Artispot, Artifol, Articulating Paper): These scored 2, 5, and 6 respectively.
    • There is a significant difference between Visual Acuity and the three aids in detecting open contacts.
    • There is no statistically significant difference between Artispot, Artifol, and Articulating Paper.
  2. “Open” Contacts
    • Artispot: Identify zero open contacts. There is a statistically different from Visual Acuity and Artispot.
    • Visual Acuity and Articulating Paper: There is no statistically significant difference in detecting open contacts.
    • Artifol: There is no statistically significant difference between Artifol, visual acuity, and Articulating Paper in detecting open contacts.
  3. “Perfect” Contacts
    • Visual Acuity: Identified the fewest “Perfect” contacts. There is a significant difference from all other groups.
    • Artispot: Identified the highest number of “Perfect” contacts (29 out of 31). There is a statistically significant difference between Artispot and all other groups in detecting perfect contacts.
    • Artifol: In detecting perfect contacts, there was a statistically significant difference between Artifol and Visual acuity as well as Artispot. There was no statistically significant difference between Artifol and Articulating Paper.

TABLE 3.

Shows statistical significance of association between contact status and study groups using Fisher's exact test.

Value Exact Sig. (2‐sided)
Fisher's Exact Test 36.890 p < 0.001

6. Discussion

The success of single‐unit posterior crowns depends not only on marginal accuracy but also on the establishment of physiologic proximal contacts that permit complete seating without additional chairside modification [5]. Despite the routine clinical importance of proximal contact adjustment, considerable variability exists in both assessment techniques and adjustment materials, often leading to tight or open contacts that compromise crown seating and long‐term periodontal health.

The present prospective randomized clinical study was therefore undertaken to evaluate crown seating following proximal contact adjustment using four commonly employed methods: artifol, articulating paper, Arti‐Spot, and visual acuity alone. The findings demonstrated a statistically significant association between the adjustment method and contact quality, thereby indicating that contact evaluation is highly method dependent and emphasizing the limitations of relying on a single assessment technique.

Visual acuity demonstrated a significantly higher incidence of tight contacts and the lowest number of ideally seated crowns, indicating a systematic tendency toward over‐contoured proximal surfaces when adjustment relies solely on visual judgment as depicted in Figure 5A,B. As evaluation was performed on casts under optimal visibility, this finding likely reflects the intrinsic limitation of visual assessment in quantifying contact resistance rather than viewing constraints. Proximal contact tightness is a force‐dependent parameter that cannot be accurately inferred from surface appearance alone; minor convexities or microscopic irregularities, imperceptible visually, may generate excessive friction during clinical seating. In addition, operators may intentionally preserve fuller contacts to avoid open contacts, introducing a conservative bias toward tightness. These observations are consistent with previous reports demonstrating poor accuracy of subjective contact evaluation and emphasizing the superiority of calibrated adjunctive methods such as artifol and articulating films for reliable proximal assessment [4, 6]. Consequently, visual acuity appears to lack sensitivity for precise contact evaluation, reinforcing the need for adjunctive aids in routine clinical practice. Although commonly used due to convenience, it is prone to subjective bias and limited diagnostic resolution.

Artispot identified the highest number of perfect contacts and failed to detect any open contacts. Artispot, a solvent‐based liquid applied by brush to restorations, drying to a 3 μm film, formulated to identify contact interferences that prevent accurate seating of the dental restorations. Various studies reveal that such thin film‐based methods for proximal contact evaluation provide superior precision in dental contact assessment by marking only true interferences without false positives [7, 8]. Thinner films conform better to tooth morphology, registering exact occlusal or proximal contacts within thicker film areas, reducing unnecessary adjustments. They avoid over‐marking from bulk, ensuring accurate high‐spot localization on restorations [9]. While this may initially suggest superior performance, it also raises concern regarding potential overestimation of optimal contacts.

Artifol and articulating paper demonstrated similar performance patterns across all contact categories, with no statistically significant difference observed between them. Artifol is an ultra‐thin articulating film (typically 8 μm). The findings of the present study may further be interpreted in light of the observations by Malta Barbosa et al., who demonstrated that the actual thickness of articulating papers and foils frequently differs from the manufacturer's reported values. Their study revealed that only certain ultrathin foils exhibited true thicknesses ≤ 21 μm, while several materials were significantly thicker than claimed [10]. This discrepancy is clinically relevant, as thicker marking media may artificially separate adjacent teeth and produce false‐positive proximal contacts, potentially interfering with complete crown seating. In the present study, the relatively lower percentage of perfectly seated crowns in the articulating paper group may be partly attributed to the greater thickness of the material (40 μm), which could have exaggerated contact intensity and led to over‐adjustment or incomplete seating. Therefore, prosthodontically the message is unmistakable: precision in proximal contact adjustment is not a minor technical detail; it is the fulcrum upon which biological health, mechanical stability, and restorative longevity pivot. The statistically significant differences observed in this study affirm that the choice of marking medium directly influences clinical outcomes. These findings advocate for a deliberate shift toward refined, ultrathin, and objective marking systems such as Arti‐Spot, particularly in posterior regions where access, visibility, and tolerance for error are minimal.

7. Clinical Significance

Subtle binding points, marginal discrepancies, or internal friction areas often go undetected, leading to incomplete seating that may silently sabotage the restoration through marginal gaps, cement dissolution, occlusal imbalance, or long‐term periodontal consequences. In essence, this study highlights a simple yet powerful principle: the fine line of fit is governed by the precision of the method used to reveal it. Therefore, accurate detection of contact quality is essential for long‐term restorative success. Based on the present results, incorporating adjunctive aids, particularly Artispot, Artifol, or articulating paper alongside visual inspection, is recommended to improve clinical accuracy.

8. Limitation

The present study was limited to single‐unit posterior porcelain‐fused‐to‐metal crown. As the operator performing proximal contact adjustments was aware of group allocation, the possibility of operator bias cannot be completely excluded. However, all procedures were standardized and the final assessment was performed by a blinded independent clinician to minimize subjective bias. Future studies incorporating larger sample sizes, multiple operators, and digital contact analysis are recommended to strengthen the evidence base.

9. Conclusion

Within the limitations of this study, it can be concluded that the method used for proximal contact adjustment significantly affects crown seating. Visual acuity alone resulted in a higher number of tight contacts and fewer perfectly seated crowns, indicating its limited reliability. Among the methods evaluated, Arti‐Spot demonstrated superior precision, enabling the highest rate of accurate crown seating. Its ultrathin film (≈3 μm) acts almost like a “truth serum” for the clinician, revealing contact discrepancies without distorting the seating path. In contrast, articulating paper, with its significantly greater thickness, behaves more like a blunt diagnostic instrument prone to smudging, overmarking, and creating false guidance, especially within deep or constricted proximal embrasures.

Author Contributions

Mitali Ashwin Jain: conceptualization, methodology, data collection, statistical analysis. Krishna Prasad D.: manuscript drafting, Literature review, critical revision.

Funding

The authors have nothing to report.

Conflicts of Interest

The author declares no conflicts of interest.

Acknowledgments

The authors would like to acknowledge the Department of Prosthodontics and Crown & Bridge and the institutional research facilities for their support.

Jain M. A. and D. K. P., “Evaluation of the Seating of Crowns After Adjusting Proximal Contacts Using Different Materials,” Journal of Esthetic and Restorative Dentistry 38, no. 9 (2026): 1832–1839, 10.1111/jerd.70158.

This manuscript has not been published previously and is not under consideration elsewhere.

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

References

  • 1. Harper K. A. and Setchell D. J., “The Use of Shimstock to Assess Occlusal Contacts: A Laboratory Study,” International Journal of Prosthodontics 15, no. 4 (2002): 347–352. [PubMed] [Google Scholar]
  • 2. Kim D. and Rothchild D., “Simplifying Accurate Evaluation: Adjustment of Proximal Contacts,” Dentistry Today 1, no. 1 (2010): 146–147. [PubMed] [Google Scholar]
  • 3. Truong V. M., Kim S., Yi Y. J., and Park Y. S., “Food Impaction in Dentistry: Revisited,” Oral Health & Preventive Dentistry 21 (2023): 229–242. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Hansen P. A., Atwood A., Shanahan M., and Beatty M., “The Accuracy of Clinician Evaluation of Interproximal Contacts Using Different Methods,” Journal of Prosthetic Dentistry 123, no. 2 (2020): 284–289. [DOI] [PubMed] [Google Scholar]
  • 5. Kim D. S., Lau L. N., Kim J. W., and Yeo I. S., “Measurement of Proximal Contact of Single Crowns to Assess Interproximal Relief: A Pilot Study,” Heliyon 9, no. 10 (2023): e20403. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Dörfer C. E., Von Bethlenfalvy E. R., Staehle H. J., and Pioch T., “Factors Influencing Proximal Dental Contact Strengths,” European Journal of Oral Sciences 108, no. 5 (2000): 368–377. [DOI] [PubMed] [Google Scholar]
  • 7. Kim D. S., Yoo S. Y., Kim J. H., Shin D. J., and Park J. M., “A Comparison of Stone‐Based and Diamond Strip Approaches for Adjusting Proximal Contact Tightness in Zirconia and PFM Crowns,” BMC Oral Health 25, no. 1 (2025): 630. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Prasadh S. S., “A Novel Technique Using Arti‐Spot Coated on Fleximeter Strips to Determine the Clearance During Tooth Preparation in Fixed Partial Denture,” Journal of the Indian Prosthodontic Society 15, no. 1 (2015): 14–16. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9. Bozhkova T., Musurlieva N., Slavchev D., Dimitrova M., and Rimalovska S., “Occlusal Indicators Used in Dental Practice: A Survey Study,” BioMed Research International 2021 (2021): 2177385. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Malta Barbosa J., Urtula A. B., Hirata R., and Caramês J., “Thickness Evaluation of Articulating Papers and Foils,” Journal of Esthetic and Restorative Dentistry 30, no. 1 (2018): 70–72. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.


Articles from Journal of Esthetic and Restorative Dentistry are provided here courtesy of Wiley

RESOURCES