. 2026 Aug 18;41(1):192. doi: 10.1007/s10103-026-04993-3

Patient-reported satisfaction and experience of a novel 40.68 MHz radiofrequency therapy: a retrospective real-world study

Hui Shao 1,#, Qiang Chen 1,#, Lu Wang 1, Yilong Wang 1, Ruijia Dong 1, Jieying Tang 1, Lujia Chen 1, Jianmin Yang 1, Shihong Zhang 1, Weiwei LI 1,✉
PMCID: PMC13486067  PMID: 42611337

Abstract

Radiofrequency (RF) therapy is a well-established non-invasive approach for skin rejuvenation. However, patient-reported outcomes (PROs)— including satisfaction, treatment experience, and tolerability—remain underreported in newer RF devices. This retrospective real-world study aimed to evaluate patient-reported outcomes (PROs) following a single treatment with a novel 40.68 MHz monopolar RF device for facial skin tightening and contouring. We specifically assessed treatment experience, satisfaction drivers, patient-perceived improvement, and tolerability from the patient’s perspective. 76 patients who received a single full-face treatment were enrolled in this retrospective, cross-sectional survey study. A structured questionnaire was administered at the 3-month follow-up to assess global aesthetic improvement, domain-specific satisfaction, treatment experience, and tolerability. Physician assessment of standardized photographs at 3 months was also performed as a supportive measure. High overall satisfaction was reported, with 86.84% (95% CI: 77.5% to 92.7%) of patients being “satisfied” or “very satisfied.” The greatest improvements were observed in skin tightening/lifting and facial contour, particularly in the jawline (50% (38/76) identified it as the most improved area). The procedure was well-tolerated: 88.16% (67/76, 95% CI: 79.2% to 93.6%) reported intraoperative pain ≤ 3 on a 10-point VAS, 94.74% (72/76, 95% CI: 87.6% to 97.8%) experienced no significant side effects, and 80.26% (61/76) had no or less than 1 day of downtime. Notably, 98.68% (75/76, 95% CI: 93.5% to 99.8%) expressed willingness to undergo repeat treatment. Physician assessment at 3 months also showed improvement in 92.11% (70/76, 95% CI: 83.6% to 96.3%) of patients, similar to the patient-reported improvement rate of 94.74% (72/76). Patients in this real-world study reported high satisfaction, perceived improvement, and good tolerability with the novel 40.68 MHz RF treatment, along with minimal downtime and a strong willingness to repeat treatment. No device-related adverse events were reported by patients in the survey.

Supplementary Information

The online version contains supplementary material available at 10.1007/s10103-026-04993-3.

Keywords: Monopolar radiofrequency, 40.68 MHz, Patient satisfaction, Patient-reported outcomes, Tolerability

Introduction

With the growing public pursuit of aesthetic enhancement, there has been a concurrent rise in the demand for skin rejuvenation treatments. Wrinkles, as the most visible sign of skin aging, have become a primary factor in perceiving an individual’s age [1]. The formation is closely associated with the degradation of collagen and elastin fibers within the dermis. The progressive loss of these structural proteins markedly compromises dermal support and elasticity, ultimately leading to skin laxity and wrinkle formation [2]. Although traditional rhytidectomy can partially address facial sagging, its clinical adoption remains limited due to significant invasiveness, prolonged recovery, risks of nerve injury, and potential complications such as hematoma [3]. In this context, non-invasive rejuvenation technologies have rapidly emerged alongside advancements in energy-based devices. Among them, radiofrequency (RF) technology has become a research focus in recent years due to its favorable clinical outcomes and tolerable profile [4].

RF delivers high-frequency alternating current into the tissue, where electrical impedance converts energy into thermal energy, primarily tightening the dermis and subcutaneous layers [5]. Its mechanism of action includes immediate collagen fiber contraction followed by a wound-healing cascade triggered by controlled thermal injury. This process upregulates type I collagen mRNA expression and stimulates neocollagenesis, culminating in dermal remodeling. Monopolar RF, in particular, is widely regarded as an effective option for non-invasive skin tightening due to its deeper penetration depth compared with bipolar or multipolar configurations.

However, much of the existing evidence relies heavily on physician-assessed outcomes or histological endpoints. While surveys have captured the physician’s perspective on RF treatment, systematic data focusing on the patient’s subjective experience—including satisfaction drivers, treatment comfort, and perceived value—remain scarce. To address this gap, this study conducted a multidimensional questionnaire-based follow-up with 76 patients treated with a novel 40.68 MHz monopolar RF device. The primary aim was to systematically evaluate patient-reported outcomes (PROs), capturing detailed insights into treatment experience, satisfaction, and tolerability. We aimed to provide clinicians with actionable data to better understand patient priorities, manage expectations, and ultimately enhance the treatment experience in clinical practice.

Materials and methods

Treatment regimen

This was a single-center, retrospective cross-sectional survey study. Patients received a single full-face treatment with the novel 40.68 MHz monopolar RF device (LW USW01-I, Guizhou Lewo Medical Device Co., Ltd, China, Fig. 1). The study utilized two parallel assessment components: (1) a patient-reported questionnaire administered at the 3-month follow-up; (2) physician assessment of standardized clinical photographs taken at baseline, 1 month, and 3 months post-treatment. All analyses were performed using Excel software for data management, and SPSS 26.0 version for statistical computations. Data were analyzed in aggregate to protect participant anonymity.

Fig. 1.

Fig. 1

The novel 40.68 MHz radiofrequency device with two handpieces

Treatment protocol

All patients received a single full-face treatment using the novel 40.68 MHz monopolar RF device (LW USW01-I). The procedure followed a standardized three‑stage “low‑high‑low” energy modulation strategy. In stage 1 (preheating), a circular handpiece was moved in an overlapping spiral trajectory over the entire face for 2–3 passes, delivering continuous low‑energy pulses to raise skin temperature to 39–42 °C. In stage 2 (spot treatment), a square handpiece was applied to predefined facial zones (jawline, cheeks, peri‑ocular area, nasolabial folds, forehead) and delivered a single high‑energy short pulse per contact point before moving to the next area. In stage 3 (consolidation), the circular handpiece was used again with low energy to cover delicate areas (periorbital, alar regions) and provide a final mild pass over the whole face. Total treatment duration was 55–65 min. No skin cooling or anesthesia was used. Experienced operators performed all treatments following a standardized training protocol. Each handpiece can deliver up to 1000 pulses; the actual number of pulses delivered to each patient was individualized based on the patient’s tolerance and clinical endpoint.

In our clinical protocol, energy levels were typically set between 5 and 8 for the face, with lower ranges (4–7) applied to the peri‑ocular area, and submental region. Output duration was generally 0.8–1.2 s, extending to 1.3–1.5 s for thicker tissue areas. Pulse counts per session were approximately 600–700 for the full face, 200–300 for the peri‑ocular area, and 100–200 for the submental region. The target skin temperature was set at 42 °C and adjusted according to individual patient thermal sensation and tolerance.

Follow-up and questionnaire distribution

Patients were treated between November 2025 and December 2025. All patients returned for follow-up visits at 1 month and 3 months post‑treatment. The 3‑month follow‑up survey was conducted during a scheduled clinic visit (with a window of ± 2 weeks from the exact 3‑month date for each patient), and the questionnaire was distributed electronically via an anonymous online link (WeChat to the Wenjuanxing® platform). Eligibility was restricted to adult patients who had undergone a single treatment with the novel 40.68 MHz monopolar RF device (“Shiguang Maji”, LW USW01-I, Guizhou Lewo Medical Device Co., Ltd, China, Fig. 1) for mild-to-moderate facial skin laxity and/or submental fat accumulation. To ensure the assessment reflected only the effects of the RF treatment, respondents were excluded if they had received any other concurrent aesthetic procedures or those within six months prior to the study that could alter wrinkle depth, skin laxity, texture, or fat volume. This remote and anonymous data collection method was chosen to encourage candid responses and minimize potential bias associated with in-person administration in a clinical setting.

Patient questionnaire

The full questionnaire (original Chinese and English translation) is provided as Supplementary Material 1.

A structured, self-administered questionnaire was developed to evaluate patient-reported outcomes (PROs), encompassing the following four domains:

  1. Patient Global Aesthetic Improvement and Satisfaction: Assessed using the 5-point Global Aesthetic Improvement Scale (PGAIS) and a 5-point overall satisfaction scale.The PGAIS uses the same 5‑point scale as the physician GAIS: 1 = very much improved, 2 = much improved, 3 = improved, 4 = no change, 5 = worse.

  2. Specific Clinical Improvements: Evaluated satisfaction levels across five key aspects—skin tightening/lifting, skin smoothness/texture, skin glow/tone, wrinkle reduction, and facial contour improvement—using 5-point Likert scales. Participants also identified the single facial area of greatest satisfaction.

  3. Treatment Experience and Tolerability: Captured intraoperative pain on a 10-point Visual Analog Scale (VAS), documented the incidence and duration of common adverse events (e.g., redness, swelling), and recorded the duration of social downtime.

  4. Long-term Outcomes and Future Intentions: Elicited the time to first noticeable improvement, time to peak effect, likelihood of recommending the treatment to others, and willingness to undergo repeat treatment.

This questionnaire was developed by the authors for this study and has not been assessed for reliability and validity.

Physician assessment of photographs

Standardized clinical photographs were taken for all patients at three time points: at baseline (pre‑treatment), at 1 month post‑treatment, and at the 3‑month follow-up visit. Photographs were captured under consistent lighting and patient positioning (frontal, left oblique, right oblique, and lateral views) using a digital camera (Canon EOS, Tokyo, Japan).

Two independent physician assessors evaluated the images. The assessors were blinded to patient identity and to patient-reported outcomes. However, because the photographs were presented in chronological order (baseline, 1 month, 3 months) for each patient, the assessors were not blinded to the time point. For each patient, the assessors rated global improvement in facial skin laxity and contour using the 5-point Global Aesthetic Improvement Scale (GAIS) : 1 = very much improved, 2 = much improved, 3 = improved, 4 = no change, 5 = worse. This scale was applied to the overall face and secondarily to five specific subregions: jawline/lower face, cheeks/mid‑face, peri‑ocular area, nasolabial folds, and forehead. In case of disagreement between the two assessors, a consensus score was reached by discussion. The physician‑assessed scores were used as a supportive endpoint to complement the patient‑reported outcomes.

Statistical analysis

Descriptive statistics were used to summarize the data. Categorical variables are presented as numbers and percentages. The 95% confidence intervals for key proportions were calculated using the Wilson score method. For the comparison of physician‑assessed improvement between 1 month and 3 months, McNemar’s test for paired proportions was applied. A p‑value < 0.05 was considered statistically significant. All analyses were performed using SPSS version 26.0 (IBM Corp., Armonk, NY, USA).

Results

Participant characteristics

A total of 102 questionnaires were distributed between March 1 and March 31, 2026. Of these, 76 were completed and deemed valid for analysis, yielding a response rate of 74.5%. During the study period, 112 patients underwent the RF treatment. Ten patients were excluded because they did not meet the eligibility criteria (e.g., received other concurrent aesthetic procedures within six months prior to the study), leaving 102 eligible patients who were invited to complete the survey. The cohort consisted of 65 (85.5%) female and 11 (14.5%) male patients, with a mean age of 43.2 ± 8.7 years (range: 28–62). All participants were of Han Chinese ethnicity. Based on the Fitzpatrick scale, skin types were distributed as follows: Type III (65.8%, n = 50), Type IV (31.6%, n = 24), and Type V (2.6%, n = 2). According to the treating physician’s assessment prior to treatment, facial skin laxity was graded as mild in 59.2% (n = 45) and moderate in 40.8% (n = 31) of participants.

A representative clinical example is shown in Fig. 2.

Fig. 2.

Fig. 2

A 39-year-old female received the novel 40.68 MHz RF device treatment. (A, D, G) baseline. (B, E, H) 1 month post-treatment. (C, F, I) 3 months post-treatment

Physician-assessed improvement

Two independent physician assessors evaluated standardized photographs at 1 and 3 months post‑treatment relative to baseline using the 5‑point GAIS (1 = very much improved, 5 = worse). At 1 month, 88.16% (67/76) of patients were rated as showing at least mild improvement (combining “very much improved”,“much improved”, and “improved”), and 40.79% (31/76) were rated as showing moderate or marked improvement (i.e., GAIS scores 2 or 1). At 3 months, the overall improvement rate increased to 92.11% (70/76), with 64.48% (49/76) achieving moderate or marked improvement.

Table 1 presents the proportion of patients achieving moderate or marked improvement for the overall face and for each subregion at 1 and 3 months. The overall face showed a significant increase from 40.79% at 1 month to 64.48% at 3 months (P < 0.001). Among subregions, the jawline/lower face demonstrated the highest improvement rate at both time points (42.11% at 1 month, 60.53% at 3 months), followed by the cheeks/mid‑face (31.58% and 44.74%). Significant increases from 1 to 3 months were observed for the jawline/lower face (P = 0.004), cheeks/mid‑face (P = 0.031), and nasolabial folds (P = 0.022).

Table 1.

Physician‑assessed moderate or marked improvement at 1 and 3 months post‑treatment (5-point GAIS, % of patients, n = 76)

Region/subregion 1 month(%,n/N) 3 months(%,n/N) P values
Overall face 40.79% (31/76) 64.48% (49/76) < 0.001
Jawline/lower face 42.11% (32/76) 60.53% (46/76) 0.004
Cheeks/mid-face 31.58% (24/76) 44.74% (34/76) 0.031
Nasolabial folds 23.68% (18/76) 35.53% (27/76) 0.022
Peri-ocular area 15.79% (12/76) 22.37% (17/76) 0.332
Forehead 9.21% (7/76) 13.16% (10/76) 0.549

P values are for increase from 1 month to 3 months

Patient-reported global aesthetic improvement and satisfaction

PGAIS assessment demonstrated that 94.74% (72/76, 95% CI: 87.6% to 97.8%) of respondents reported an improvement in their appearance: 15.79% (12/76, 95% CI: 9.2% to 25.0%) “Very Much Improved,” 55.26% (42/76, 95% CI: 44.2% to 65.9%)“Much Improved,” and 23.68% (18/76, 95% CI: 15.4% to 34.5%) “Improved”, while 5.27% (4/76, 95% CI: 2.1% to 12.5%) perceived “No Change” (Fig. 3A). Consistent with these findings, the overall satisfaction survey revealed that 86.84% (95% CI: 77.5% to 92.7%) of subjects were satisfied with the treatment results: 28.95% (22/76, 95% CI: 19.8% to 40.0%) “Very Satisfied” and 57.89% (44/76, 95% CI: 46.6% to 68.5%) “Satisfied.” Neutral ratings accounted for 13.16% (10/76, 95% CI: 7.3% to 22.5%) (Fig. 3B).

Fig. 3.

Fig. 3

Patient‑reported global aesthetic improvement, satisfaction, and specific clinical benefits at 3 months post‑treatment

Specific clinical improvements

Satisfaction analysis revealed the predominant strengths of the radiofrequency treatment. Subjects reported the highest satisfaction level with “Skin Tightening/Lifting” accounting for 93.42% (71/76, 95% CI: 85.9% to 97.1%) when combining “Very Satisfied” and “Satisfied”) responses, followed by “Facial Contour Improvement” (82.89%, 95% CI: 73.0% to 89.8%) and“Skin Smoothness/Texture” at 76.31%(58/76, 95% CI: 65.8% to 84.4%) (Fig. 3C). When inquiring about the “Most Satisfied Area,” the jawline/lower face was the most recognized region for improvement at 50% (38/76, 95% CI: 39.2% to 60.8%), followed by the cheeks/mid-face (42.11%, 95% CI: 31.6% to 53.3%) and the peri-ocular area at 7.89% (6/76, 95% CI: 3.7% to 16.2%) (Fig. 3D).

Treatment experience and tolerability

In the assessment of pain/discomfort levels using VAS, 88.16% (67/76, 95% CI: 79.2% to 93.6%) of subjects reported scores ≤ 3: 28.95% (22/76, 95% CI: 19.8% to 40.0%) reported “no pain at all” and 59.21% (45/76, 95% CI: 47.9% to 69.7%) reported “mild, easily tolerable”, indicating that the procedure was generally well-tolerated (Fig. 4E). Post-treatment recovery outcomes were similarly favorable. 94.74% (72/76, 95% CI: 87.6% to 97.8%) of subjects reported “no significant side effects” (Fig. 4F). Among the transient side effects reported, “redness (resolved within 24 hours)” was noted in 3.95% (3/76, 95% CI: 1.4% to 10.7%) and “Tenderness to touch” in 1.32% (1/76, 95% CI: 0.2% to 7.1%) were the most common. Consequently, 80.26% (61/76, 95% CI: 70.3% to 87.5%) of subjects experienced “no downtime or downtime less than 1 day,” highlighting the significant “no-downtime” advantage of this technology (Fig. 4G).

Fig. 4.

Fig. 4

Treatment experience and tolerability

Perceived timing of effect and future intentions

Regarding the time to noticeable effect, 71.05% (54/76, 95% CI: 60.1% to 80.0%) of subjects first observed visible improvement “immediately after (within the first week)” (Fig. 5H). A significant proportion of subjects: 80.26% (61/76, 95% CI: 70.3% to 87.5%) reported that “the results are still improving” at the 3-month mark, while 15.79% (12/76, 95% CI: 9.2% to 25.0%) perceived their results peaked within 1–3 months (Fig. 5I). Exceptionally high patient loyalty was demonstrated, with 77.63% (59/76, 95% CI: 67.2% to 85.4%) of subjects being “very likely” to recommend this treatment to friends or family (Fig. 5J). More importantly, 98.68% (75/76, 95% CI: 93.5% to 99.8%) explicitly expressed willingness to undergo the treatment again (Fig. 5K).

Fig. 5.

Fig. 5

Perceived timing of effect and future intentions

Discussion

Over the past two decades, RF technology has emerged as one of the mainstream options for non-invasive skin rejuvenation, owing to its favorable safety profile, demonstrated efficacy, and broad applicability across all skin types. However, in the clinical decision-making process of aesthetic medicine, patients are often presented with a variety of treatment options. The ultimate success and widespread adoption of a technology are determined by objective metrics, while patient-reported outcomes (PROs) also play a critical role in the evaluation [6]. These encompass the patient’s subjective perception of efficacy, comfort during treatment, and tolerability—factors that collectively determine satisfaction and treatment adherence. In our study, PROs indicated that 80.26% of participants reported sustained improvement at the 3-month follow-up, a timeline consistent with the expected duration of active dermal remodeling and neocollagenesis following RF treatment. Notably, this favorable experience likely contributed to the strong treatment acceptance, with 98.68% of subjects expressing willingness to undergo repeat sessions. Importantly, physician assessment of standardized photographs at 3 months also showed improvement in 92.11% of patients, which was comparable to PGAIS.

The device evaluated operates at 40.68 MHz, substantially higher than conventional RF systems (e.g., 6.78 MHz). From a biophysical standpoint, higher frequencies alter electromagnetic field distribution and may enhance volumetric heating efficiency in deeper dermal and subcutaneous tissues. A study demonstrated that 40.68 MHz RF induced upregulation of type I collagen, TGF-β, and VEGF mRNA, alongside adipose tissue atrophy in murine skin, implying a dual mechanism of collagen regeneration and potential fat modulation [7]. Our PRO data revealed the highest satisfaction rates were observed in the lower face, a region rich in subcutaneous fat, with 50% of subjects identifying it as the most improved area. In contrast, the forehead, which has minimal fat layer, received the lowest satisfaction ratings. Based on these observations and previous animal findings, we hypothesize that adipose-rich regions might accumulate more thermal energy, which could theoretically play a role in the observed contour improvement; however, this hypothesis was not directly tested in our study and requires future investigation. Conversely, areas with thinner subcutaneous fat layers may exhibit a more limited remodeling response, likely due to reduced thermal effects, although this remains speculative. This regional difference was also observed in the physician assessments: the jawline/lower face was also rated as the most improved subregion (60.53% moderate or marked improvement), whereas the forehead showed the lowest improvement rate (13.16%).

Pain during RF treatment has consistently been a critical factor affecting patient experience and treatment compliance [8]. To improve treatment comfort, most current devices are equipped with epidermal cooling systems [9]. In our study, despite the absence of active cooling or anesthesia, patients reported low pain scores (88.16% with VAS ≤ 3). We attribute this favorable tolerability to the three‑stage “low‑high‑low” energy modulation strategy described in the Methods. Briefly, the initial low‑energy preheating phase gradually raises tissue temperature to 39–42 °C, which delays thermoreceptor activation and raises the pain threshold [10]. The subsequent high‑energy spot treatment delivers concentrated thermal energy to deeper layers, inducing controlled thermal injury and stimulating dermal remodeling [11], while the final low‑energy consolidation pass covers any gaps and enhances clinical outcomes without additional discomfort. This “low‑high‑low” approach is consistent with previous reports that fractionated, moderate‑energy regimens improve tolerability without compromising long‑term results, compared with single high‑fluence treatments [12, 13]. The primary objective of this study was to capture the subjective treatment experience of patients. As a real-world investigation, the design has inherent limitations: First, the retrospective, single-center, uncontrolled, and cross-sectional study design, combined with the use of a patient-reported questionnaire that had not undergone psychometric validation, limits causal inference and the generalizability of the findings to some extent. Recall bias and potential response bias may also affect the accuracy of the patient-reported outcomes (PROs). Although we could not formally compare responders and non-responders due to the anonymous survey design, the response rate of 74.5% is relatively high, which somewhat mitigates concerns about non-response bias. Second, the follow-up period was only three months, and the cohort was relatively homogeneous (all participants were Han Chinese, with Fitzpatrick skin types predominantly III–IV), which to some degree restricts the applicability of the conclusions to other populations and the assessment of long-term efficacy. Third, this study was limited to subjective assessments; objective outcome measures such as three‑dimensional imaging or elastometry were not employed [14]. Future investigations should incorporate both objective measurements and patient‑reported outcomes to provide more comprehensive evidence. Nevertheless, this study provides valuable real-world patient-reported data that can serve as an important reference for future clinical practice and related research.

Conclusion

In summary, this study indicates that treatment with the novel 40.68 MHz monopolar radiofrequency device is associated with high patient-reported improvement and satisfaction in mild-to-moderate facial skin laxity and contour. Physician assessment also showed improvement in 92.11% of patients at 3 months, with the jawline/lower face identified as the most responsive region by both patients and clinicians. Furthermore, the treatment was reported as well-tolerated with minimal downtime in this cohort, which correlates with strong patient willingness for retreatment. These findings support the potential of this technology as a well-tolerated, non-invasive option in aesthetic medicine and warrant further evaluation in randomized controlled trials.

Supplementary Information

Below is the link to the electronic supplementary material.

Author contributions

H.S. and Q.C. contributed equally to this work. H.S.: data analysis and original draft writing. Q.C.: data analysis and manuscript revision. W.L.: review and editing. All authors reviewed and approved the final manuscript.

Funding

No funding was received for conducting this study.

Data availability

Data are available on reasonable requests from the corresponding author.

Declarations

Ethical approval

This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Beijing Tsinghua Changgung Hospital (approval No. 26013-6-01).

Consent for publication

All patients provided written informed consent for the publication of their anonymized clinical photographs. No identifiable images of human participants are included in this article.

Consent to participate

All patients provided written informed consent for the treatment and for the use of their anonymized photographs and questionnaire data for research purposes.

Clinical trial number

Not applicable.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Hui Shao and Qiang Chen contributed equally to this work.

References

  • 1.Yang XX, Zhao MM, He YF et al (2022) Facial Skin Aging Stages in Chinese Females [J]. Front Med (Lausanne) 9:870926 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Chavoshnejad P, Foroughi AH, Dhandapani N et al (2021) Effect of collagen degradation on the mechanical behavior and wrinkling of skin [J]. Phys Rev E, 104(3 – 1): 034406 [DOI] [PubMed]
  • 3.Xie Y, Brenner MJ, Sand JP et al (2021) Adverse events in facial plastic surgery: data-driven insights into systems, standards, and self-assessment. Am J Otolaryngol 42(1) [DOI] [PubMed] [Google Scholar]
  • 4.Gold MH (2017) The Future of Non-Invasive Rejuvenation Technology: Devices [J]. J Drugs Dermatol 16(6):s104–s7 [PubMed] [Google Scholar]
  • 5.Goldman MP, Kilmer SL, Biesman B et al (2025) Monopolar Radiofrequency-Induced Fibroblast Stimulation for the Prevention and Improvement of Skin Laxity [J]. Dermatol Surg 51(9s):S38-s43 [DOI] [PubMed] [Google Scholar]
  • 6.Rhee JS, McMullin BT (2008) Outcome measures in facial plastic surgery: patient-reported and clinical efficacy measures [J]. Arch Facial Plast Surg 10(3):194–207 [DOI] [PubMed] [Google Scholar]
  • 7.Kim M, Kim KE, Jeong SW et al (2016) Effects of the ultra-high-frequency electrical field radiofrequency device on mouse skin: a histologic and molecular study. Plast Reconstr Surg 138(2):248e–55e [DOI] [PubMed] [Google Scholar]
  • 8.Suh DH, Hong ES, Kim HJ et al (2020) A survey on monopolar radiofrequency treatment: the latest update. Dermatol Ther 33(6) [DOI] [PubMed] [Google Scholar]
  • 9.Lee S, Hyun J, Shin Y et al (2024) Efficacy and safety of a novel monopolar radiofrequency device with a continuous water-cooling system in patients with age-related facial volume loss [J]. J Dermatolog Treat 35(1):2333028 [DOI] [PubMed] [Google Scholar]
  • 10.Zhu P, Xie C, Li K et al (2025) Selective and controllable mechanism of the temperature field in skin tissue under radiofrequency heating: finite element analysis and ex-vivo pig skin experiments. J Therm Biol 131 [DOI] [PubMed] [Google Scholar]
  • 11.Dams SD, de Liefde-van Beest M, Nuijs AM et al (2010) Pulsed heat shocks enhance procollagen type I and procollagen type III expression in human dermal fibroblasts. Skin Res Technol 16(3):354–64 [DOI] [PubMed] [Google Scholar]
  • 12.Kist D, Burns AJ, Sanner R et al (2006) Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment. Lasers Surg Med 38(2):150–4 [DOI] [PubMed] [Google Scholar]
  • 13.Dover JS, Zelickson B (2007) Results of a survey of 5,700 patient monopolar radiofrequency facial skin tightening treatments: assessment of a low-energy multiple-pass technique leading to a clinical end point algorithm [J]. Dermatol Surg 33(8):900–907 [DOI] [PubMed] [Google Scholar]
  • 14.Ponzo M, Lombardi M, Avvedimento S et al (2026) Efficacy and safety of poly-L-lactic acid for midface rejuvenation: a 12-month split-face controlled evaluation with 3D imaging and patient-reported outcomes. Aesthet Surg J 46(6):663–71 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

Data are available on reasonable requests from the corresponding author.


Articles from Lasers in Medical Science are provided here courtesy of Springer