Skip to main content
. 2025 Sep 15;76(4):332–338. doi: 10.1007/s13224-025-02234-1

Table 3.

Comparison of normal and abnormal echocardiographic parameters in Preeclamptic women (Group I)

SN Parameters Normal Echocardiographic findings (n = 41) Abnormal Echocardiographic findings (n = 38) Statistical significance
Mean SD Mean SD ‘t’ ‘p’
I- Systolic parameters
1- LV ESV (ml) 41.89 4.92 59.57 16.92 − 6.406 < 0.001
2- LV EDV (ml) 94.19 7.99 114.09 19.66 − 5.975 < 0.001
3- LV Dias diam (cm) 4.06 0.15 4.49 0.37 − 6.824 < 0.001
4- LV Sys diam (cm) 2.43 0.44 2.94 0.52 − 4.695 < 0.001
5- LV Sys Mass (gm) 85.81 4.11 97.19 12.59 − 5.485 < 0.001
6- Ejection fraction (%) 62.45 2.80 47.82 13.12 6.975 < 0.001
II- Diastolic parameters
7- E wave (m/s) 0.74 0.12 1.00 0.28 − 5.481 < 0.001
8- A wave (m/s) 0.74 0.14 0.92 0.13 − 6.199 < 0.001
9- E/A ratio 1.02 0.22 1.10 0.33 − 1.174 0.244