Skip to main content
. Author manuscript; available in PMC: 2006 Jan 25.
Published in final edited form as: Anesth Analg. 2004 Mar;98(3):858–contents. doi: 10.1213/01.ane.0000100741.46539.6b

Table 2.

Intubating Laryngeal Mask Airway (ILMA) Insertion and Intubation Data.

Lateral position (n=50) Supine position (n=50)
ILMA insertion time; seconds 24(10) 22(6)
Intubation time; seconds 22 (23) 28 (30)
Total intubation time; seconds 44 (24) 50 (30)
ILMA insertion attempts
1 47 (94) 47 (94)
2 3(6) 3(6)
Grade of ILMA ventilation
Adequate 43 (86) 46 (92)
Possible 4(8) 4(8)
Impossible 3(6) 0 (0)
Intubation attempts
1 41(82) 36 (72)
2 3(6) 8 (16)
3 3(6) 3(6)
4 1(2) 3(6)
5 2(4) 0 (0)
Overall intubation success 48 (96) 48 (96)
Adjusting maneuvers*
None 41 (82) 36 (72)
ILMA size change 3(6) 6(12)
Up-down 7(12) 5(8)
Optimization 10 (16) 10 (16)
Extension 0 (0) 2(4)
*

Some patients required more than more than one adjusting maneuver. Data presented as mean (SD) or number of patients (%).