High-impact forces during jump landing pose a risk for lower limb injuries, highlighting the importance of shoe midsole cushioning, where the effectiveness of midsole hardness remains controversial. This study evaluated the biomechanical performance of three-dimensional auxetic lattice structure midsoles during jump landing, examining their cushioning mechanisms and stability. Four midsoles were tested: two auxetic lattices (A60 and A75), a non-auxetic structure (N90), and a traditional polyurethane (PU) midsole, using plantar pressure measurements (Pedar‑X system) and finite element simulations. Results showed that auxetic midsoles significantly improved overall performance, reducing peak plantar pressure and impact loading rate compared to non-auxetic designs. Specifically, A60 provided optimal forefoot pressure reduction, while A75 offered superior stability, with both enhancing pressure distribution uniformity through increased foot-shoe contact area. These findings demonstrate that auxetic lattice structures enhance jump landing cushioning in healthy young males. The angle-dependent performance trade-offs—forefoot pressure reduction for A60 and enhanced stability for A75—offer initial evidence for zoned midsole design concepts, warranting further sport-specific validation.
Supplementary Information
The online version contains supplementary material available at https://doi.org/10.1038/s41598-026-62549-5.
Keywords: Auxetic lattice structures, Athletic footwear midsoles, Cushioning, Stability, Jump landing biomechanics
Subject terms: Engineering, Health care
Introduction
Jump landing is typical for athletes, requiring maximum vertical jumping in place. Frequent jump landing activities involve various sports, such as volleyball, basketball, and handball. The combination of high-impact forces during the landing phase and the short time to reach the peak increases the mechanical demand on the lower limbs1 and elevates the risk of knee anterior cruciate ligament injuries2 and knee articular injuries3. Additionally, jump landing tasks are adopted in the final stage of rehabilitation programs after ligament injuries4. Research on footwear products in jump scenarios has primarily investigated the effects of footwear characteristics on foot-ground impact characteristics, such as time to peak force (TPF) and vertical impact loading rate (VILR). Findings on the impact of midsole hardness on plantar cushioning have been inconsistent. Some studies suggest that softer midsoles can reduce VILR in repetitive activities requiring multiple impacts, such as running5 and skipping rope6. Lam et al.7 reported better rearfoot cushioning but worse forefoot cushioning with soft midsoles. However, Nin et al.8 proposed that midsole hardness had no significant effect on plantar cushioning. These discrepancies may stem from differences in sports. Zhang et al.9 designed a bionic forefoot cushioning midsole based on the shock absorption mechanism of ostrich toe pads to improve impact absorption. Kangoo Jumps® uses spring structures to dissipate impact forces and prolong the TPF10.
The advantages of auxetic materials in terms of surface conformity and energy dissipation have led to their recent utilization in personal protective equipment and shock absorption pads11,12. Auxetic materials display zero/negative Poisson’s ratios, expanding sideways during tension and compacting during compression13. Unlike standard seat structures, auxetic-configurated frames demonstrate reduced pressure concentration during body contact, directly enhancing ergonomic comfort14. According to Yang et al.15, auxetic materials represent an optimal solution for impact-protective gear, offering injury prevention for vulnerable populations including seniors, industrial laborers, security forces, military personnel, and sports competitors without sacrificing comfort. Impact testing reveals auxetic materials attenuate peak acceleration magnitudes to one-sixth of those observed in conventional foam absorbers16. Beyond energy absorption and dissipation, auxetic materials also feature excellent properties meeting footwear requirements, such as fatigue toughness17, lightweight characteristics18 and fracture resistance19. Therefore, auxetic materials demonstrates extensive potential for application in the field of sport.
Emerging systematic evidence has consolidated the understanding of 3D-printed footwear biomechanics across three key domains: injury prevention, comfort, and athletic performance20. Additive manufacturing has enabled the fabrication of customized footwear with lightweight cellular structures, offering enhanced biomechanical performance while optimizing material efficiency21. Within this rapidly evolving landscape, parametric lattice structures have emerged as a promising design approach—studies have demonstrated that parameterized lattice insoles, optimized through finite element and machine learning methods, can reduce plantar pressure by up to 44.45% by increasing foot-shoe contact22. Similarly, 3D-printed cellular shoe soles have been shown to drastically reduce plantar pressure during running23. However, the majority of existing investigations have focused on walking and running scenarios24, with limited experimental evidence concerning the biomechanical performance of auxetic lattice midsoles during high-impact activities such as jump landing—a movement pattern critically relevant to injury risk in sports. Recent computational studies have established quantitative relationships between lattice structural parameters and plantar pressure responses using finite element and machine learning methods22,25. While these studies underscore the potential of data-driven optimization in lattice-based footwear design, they remain predominantly computational in nature and focus on walking or static loading, leaving the experimental biomechanical performance of auxetic lattice structures during dynamic high-impact activities largely unexplored. As parametric tools and additive processes permeate shoe production, researchers continuously assess the ergonomic implications of unit cell topology and mechanical behavior in auxetic-structured shoe components. Ford et al.26 applied mass-tunable auxetic geometry to shoe midsoles to reduce peak ground reaction forces and mitigate foot injury risks during intense exercise. Auxetic soles with negative Poisson’s ratio exhibit higher strain energy and energy absorption capacity than traditional soles, contributing to reducing spinal fatigue during walking27,28 and enhancing wearing comfort during walking or running29. Leung et al.30 designed auxetic re-entrant honeycomb structured round heel pads, which reduced peak contact force and average pressure in the heel compared to traditional PU foam heel pads. During vertical drop jumps, auxetic shoes may reduce the anterior-posterior distance between the ground reaction force center of pressure (CoP) and the heel, thereby decreasing the required external flexor moment and lumbosacral compression force at the lumbosacral joint, aiding in lumbar protection31. The mediolateral deviation of the plantar CoP is closely related to gait stability during jumping activities32.
Stability and comfort are fundamental functional requirements for footwear to meet sports needs and ensure foot protection33. Highly cushioned shoes are designed to increase shock absorption upon impact, theoretically reducing injury risks associated with VILR34. A sports shoe primarily consists of an outsole, midsole, insole, upper, and several reinforcements. As the main supporting structure of the shoe, the midsole acts on various plantar regions, and designers/engineers can optimize the overall pressure reduction and cushioning performance by adjusting the midsole design to prevent injuries in high-intensity sports like jumping. This research introduces a novel midsole architecture utilizing 3D re-entrant auxetic lattices synthesized from cross-stacked 2D concave hexagonal honeycombs featuring sub-90° internal angles. Through controlled angular variation of lattice units, three midsole variants were engineered and validated: two auxetic configurations with distinct acute angles and one non-auxetic benchmark. The study investigates the stability and pressure reduction cushioning performance of auxetic lattice midsoles during jump landings, addressing the following research questions: (1) Effects of different midsole types on plantar pressures; (2) Effects of different midsole types on VILR; (3) Effects of different midsole types on total mediolateral CoP deviation; (4) Effects of different midsole types on contact area.
The study combines in-shoe pressure system testing with supplementary finite element analysis (FEA) to investigate the biomechanical performance of auxetic midsoles during jump landing. A common existing polyurethane (PU) sole was used as a control in actual plantar pressure testing to verify whether auxetic lattice-structured soles contribute to pressure reduction and cushioning during jumping. Biomechanical evaluation of the interaction between the foot and shoe under jump landing conditions, analyzing the impact of shoe design characteristics on foot variables, also helps identify optimization directions for jump-cushioning footwear design. Shoe midsoles with this special cushioning structure may help prevent injuries caused by high plantar impact forces during fatigue or unconscious states.
Materials and methods
Experimental shoe midsoles design
The 3D re-entrant hexagonal lattice structure proposed by Evans et al.35 is a typical auxetic structure exhibiting negative Poisson’s ratios when loaded in all three orthogonal directions. For biomechanical benchmarking, midsoles with re-entrant auxetic lattices (60° and 75° internal angles) and a conventional lattice (90°) were designed and engineered, contrasting with a standard PU midsole control. All four midsoles were size 42. Since midsole thickness may affect ground reaction force and VILR, all experimental midsoles were ensured to have the same thickness. Each lattice-structured midsole had two layers of uniformly arranged lattice units in the longitudinal direction.
The 3D structure and geometric characteristics of lattice units for the three designed midsole types are shown in Fig. 1. Each lattice unit featured ribs with a diameter of 2.4 mm and a height of 12 mm. Based on multiple attempts at sample fabrication, it is determined that setting the rib height of the lattice unit to 12 mm provides sufficient space for lattice deformation when the shoe midsole is under compression. To isolate structural effects, the three lattice midsoles maintained near-identical material volumes (125 ± 0.88 cm³) and constant volume occupancy ratios, effectively controlling relative density variables. Specimens were digitally modeled via parametric algorithms in Rhino 7® with Grasshopper® 3.5, then additively manufactured using Tiertime UP300 FDM equipment (Beijing, China). Fabrication employed elastic thermoplastic polyurethane (TPU 95 A) under precise deposition control—achieving nozzle positioning accuracies of (x, y,z) = (2,2,0.5) µm and 0.1 mm layer resolution.
Fig. 1.

Three lattice midsole designs (A–C) and a PU midsole control (D): (A) Auxetic 60° (A60) midsole. (B) Auxetic 75° (A75) midsole. (C) Non-auxetic 75° (N90) midsole. (D) PU midsole.
Research Process
The study performed plantar pressure system testing from January 4th to 14th, 2026, to obtain real plantar biomechanical parameters, including CoP displacement, impact force, contact area, and plantar pressure. To complement the experimental measurements, FEA was performed to provide a mechanical interpretation of the observed plantar pressure trends under controlled boundary conditions, independent of inter-individual motor variability36. Ethical approval of this study was obtained from the Academic Ethics and Scientific Technology Ethics Special Committee of Guangdong University of Technology. This study strictly adhered to the ethical guidelines of the Declaration of Helsinki. All participants voluntarily signed informed consent forms after fully understanding the purpose, procedures, potential risks, and benefits of the study. They were explicitly informed of their right to withdraw unconditionally at any stage of the research without incurring any unfair treatment or loss.
Wear Trial of Proposed Midsoles
Participants
Twenty healthy male subjects (mean age: 21 ± 1.3 years) wearing standardized EU-42 footwear were enrolled based on stringent inclusion criteria: (1) no prior lower-extremity orthopedic interventions or fractures; (2) pain-free locomotion; (3) absence of musculoskeletal deformities (hallux valgus, pes planus, genu varum); (4) physiologically normal gait patterns; and (5) non-athlete status with no specialized motor training. Based on these criteria, participants aged 19–23 years had an average height of (169 ± 1.9) cm, average mass of (69 ± 4.6) kg, and foot length of (253 ± 2.0) mm.
Biomechanical experiments
Regional plantar loading analysis provides a validated methodology for assessing footwear cushioning performance37. This investigation employed the Pedar-X system (Novel GmbH, Munich, Germany) to quantify in-shoe biomechanical parameters across midsole variants. The instrumented insoles incorporate 99 capacitive sensors with 1.9 mm thickness, operating at 50 Hz sampling frequency within a 15-1200 kPa measurement range. An EU size 42/43 Pedar insole was selected for the experiment. The pressure measurement system divided the plantar foot into seven regions: hallux, toes 2–5, metatarsal heads (MTH 1, MTH 2, MTH 3–5), midfoot, and hindfoot (Fig. 2). According to F Alirezaei Noghondar and E Bressel38, participants were required to warm up and perform vertical jump-reach activities to familiarize themselves with the vertical jumping motion before starting pressure testing for each midsole. The jump landing protocol was standardized as follows. Participants performed maximal vertical jumps from a standing position, with bilateral take-off and bilateral landing on a designated force-measuring area. The right foot was analyzed for all participants. For each midsole condition, participants completed five valid trials, from which the middle three trials were averaged for statistical analysis. A trial was considered valid if the participant landed with both feet within the designated area, maintained a stable posture for at least 2 s after landing, and demonstrated no visible loss of balance. Trials with obvious foot placement outside the target area or with visible balance loss were excluded and repeated. The order of the four midsole conditions was randomized using a Latin square design to minimize order effects. A 3-minute rest period was provided between conditions to mitigate fatigue, and participants were instructed to maintain consistent effort throughout all trials.
Fig. 2.

Instrumented plantar zones for peak pressure and contact area analysis. (A) Hallux. (B) Second–fifth toe (Toes 2–5). (C) First metatarsal head (MTH 1). (D) Second metatarsal head (MTH 2). (E) Third–fifth metatarsal head (MTH 3–5). (F) Midfoot. (G) Hindfoot.
Through plantar pressure measurement experiments, peak pressure in each plantar region, the maximum foot-shoe contact area, VILR and the CoP displacement were obtained. The VILR was calculated as the maximal slope of the vertical ground reaction force-time curve from initial foot-ground contact to the first (passive) impact peak. Prior to VILR calculation, the raw force signal was processed using a fourth-order, zero-lag Butterworth low-pass filter with a cutoff frequency of 50 Hz. The VILR was then determined as the maximum positive derivative of the filtered force signal following initial contact (defined as vertical force exceeding a 5 N threshold), and expressed in N/ms39. All 3D-printed midsoles maintained structural integrity through 100 consecutive jump tests without permanent deformation, demonstrating compressive durability and impact resistance. Written informed consent was acquired from all experimental participants prior to biomechanical assessments. Additionally, based on the CoP displacement trajectory during jump landing obtained from plantar pressure measurement experiments, the total mediolateral CoP deviation was derived using the calculation method of Leong et al.40. First, the origin Xi was defined as the most posterior point of the CoP trajectory. Next, the mediolateral deviation was determined in relation to the x-axis, which is perpendicular to the longitudinal foot axis. The x coordinates (mediolateral locations of CoP) throughout the stance phase of the selected jump landing steps were extracted. The total CoP mediolateral deviation was then calculated by summing the absolute differences between the x coordinates and the CoP path, i.e., |X2 − X1|+|X3 − X2|+.+|Xi − Xi−1|.
Finite element analysis
Preparation
Mechanical characterization of 3D-printed TPU specimens was conducted using an Inspekt Table Blue 5KN universal testing system (Hegewald & Peschke, Germany). Tensile and compressive behaviors were evaluated following ASTM D638-14 and D395-03 standard test methods, respectively. Uniaxial testing yielded stress-strain data for hyperelastic material modeling.
A digital foot model was developed from 3D scans of a male subject (height: 175 cm, shoe size: EU 42) acquired using an eFoot 350 medical scanner (Stereo3D Technology, China; accuracy: ±0.5 mm). To enhance anatomical fidelity, a bone model matching the foot dimensions was integrated into the soft tissue reconstruction. Footwear interaction dynamics were simulated during motion, with kinematic data captured at 300 Hz using a NOKOV Mars 9 H optical system. Reflective markers were positioned at key anatomical landmarks (heel, toe, medial/lateral malleoli, abdomen, and hip) to track center of mass trajectory during jump landing, calculated as 40% of the abdomen-hip distance per W Erdman41.
Simulation analysis
Material mechanical properties, foot models, and motion trajectory data collected above were imported into ABAQUS FEA software (Dassault, France, version 2021) for simulation and mechanical analysis of the foot–footwear interface. The finite element model (FEM) consisted of five parts: foot soft tissue, bones, insole, midsole, and ground. The position of each component in the FEM is shown in Fig. 3A. ABAQUS processed the 3D models by meshing them into grids with a finite number of ‘elements’ with the mesh size set to 2 mm. The hyperelastic constitutive model for TPU midsole components in mechanical simulation was based on the Yeoh formulation42:
![]() |
1 |
Fig. 3.

Finite element analysis. (A) Finite element model implementation for foot-shoe interaction analysis. (B) The body weight and the center of gravity. (C) Demonstrative simulation results.
Table 1 details material properties and element formulations for each FEM component. The ground surface was subjected to rigid constraints with complete translational/rotational fixation. A tie interface connected the foot and insole domains, while midsole-floor interaction employed frictional contact. Model kinematics were driven by motion-captured y-axis nodal displacements, with coordinate updates at 10 ms intervals during dynamic simulation. A body weight force of 69.8 kg was applied as a concentrated load at the center of gravity of the human body FEM, with a gravitational acceleration of 9.8 m/s² defined globally as Fig. 3B. The FEM assumed a rigid connection between the center of mass and the ankle. Based on this setup, the impact force and extreme pressure on the plantar during jump landing were simulated and predicted as Fig. 3C showed.
Table 1.
Material properties and element types of different parts of the FEM.
| Components | Young’s modulus (E) | Poisson’s ratio (µ) | Formulation | Element types | References |
|---|---|---|---|---|---|
| Hard tissue (bones) | 7300 | 0.3 | Linear | Three dimensional tetrahedral | 43 |
| Encapsulated soft tissue | 1.15 | 0.49 | |||
| Insole | 2 | 0.35 | |||
| 3D-printed TPU | Hyperelastic | - | Non-linear | ||
| Ground support | ∞ | - | Rigid element | Quadrilateral |
TPU thermoplastic polyurethane.
Data analysis
Given the within-subject design (all 20 participants completed tests under all four midsole conditions), data were analyzed using a repeated-measures ANOVA (RM-ANOVA), with midsole condition (A60, A75, N90, PU) as the within-subject fixed factor and participant as the repeated-measures subject variable. Mauchly’s test was used to evaluate the sphericity assumption; because this assumption was violated for most dependent variables (p < 0.05), the Greenhouse–Geisser correction was applied to adjust the degrees of freedom. For post-hoc pairwise comparisons, the Bonferroni correction was employed to control for Type I error. All statistical analyses were performed using SPSS 23.0 (IBM Corp., USA), with significance level set at p < 0.05.
Results: the impact of midsole structure on plantar biomechanics
Peak plantar pressures
Figure 4 compares the PPPs in different plantar regions when wearing various midsoles during jumping. The experiment verified the influence of midsole types on plantar pressure in different regions by examining differences in data between groups (A60, A75, N90, and PU). The F-value, a key statistic in ANOVA, represents the ratio of between-group variance to within-group variance. F-values surpassing the critical threshold (F₀=2.70) denoted significant inter-group differences, with magnitude directly proportional to effect size. RM-ANOVA revealed that midsole design significantly influenced peak landing pressures across all plantar regions (p < 0.001): hallux [F(1.000, 19.000) = 6178.860, p < 0.001], toes 2–5 [F(1.000, 19.000) = 6677.335, p < 0.001], MTH 1 [F(1.000, 19.000) = 7000.370, p < 0.001], MTH 2 [F(1.000, 19.000) = 2852.531, p < 0.001], MTH 3–5 [F(1.000, 19.000) = 1060.427, p < 0.001], midfoot [F(1.000, 19.000) = 9085.152, p < 0.001], and hindfoot [F(1.000, 19.000) = 7927.324, p < 0.001]. Bonferroni-adjusted post-hoc comparisons confirmed both auxetic configurations (A60, A75) generated significantly lower regional pressures versus the non-auxetic N90 reference (p < 0.05).
Fig. 4.

PPPs in different plantar regions with four different types of shoe midsoles.
Table 2 compares the mean peak pressures of different midsoles in each plantar region and calculates the mean differences. The p-values indicate the significance of pairwise comparisons of sample means. The percentages in brackets in Table 2 represent the extent to which pressure in the first sample decreases compared to the second sample in paired comparisons. According to Table 2, 3D-printed lattice midsoles with auxetic structures significantly reduced peak pressure in all plantar regions and optimized foot pressure distribution during jump landing compared to non-auxetic midsoles. The comparison also revealed that the A60 midsole showed better forefoot pressure reduction than the A75, while the A75 midsole exhibited better pressure reduction in the midfoot and heel regions than the A60. The FEA predicted peak pressures of 472 kPa, 477 kPa, and 481 kPa for A60, A75, and N90, respectively, showing the same ranking order (A60 < A75 < N90) as the experimental measurements. The absolute values differed between FEA and experiments, which is attributable to simplifications in material modeling and boundary conditions30. Nonetheless, the consistent ranking trend provides supplementary mechanical support for the observed experimental differences between auxetic and non-auxetic structures.
Table 2.
Mean difference in PPPs between four different types of shoe midsoles.
| Variable | A60-N90 | A75-N90 | A60-PU | A75-PU | N90-PU |
|---|---|---|---|---|---|
| Hallux | -108.790*** | -50.778*** | -141.092*** | -83.080*** | -32.302*** |
| (66.62%) | (31.09%) | (72.13%) | (42.47%) | (16.51%) | |
| Toes 2–5 | -94.164*** | -15.952*** | -86.747*** | -8.535*** | 7.417*** |
| (51.89%) | (8.79%) | (49.84%) | (4.90%) | (4.26%) | |
| MTH 1 | -78.602*** | -28.023*** | -90.967*** | -40.388*** | -12.365*** |
| (39.86%) | (14.21%) | (43.41%) | (19.27%) | (5.90%) | |
| MTH 2 | -99.878*** | -51.315*** | -8.667*** | 39.896*** | 91.211*** |
| (38.46%) | (19.76%) | (5.14%) | (23.68%) | (54.15%) | |
| MTH 3–5 | -106.145*** | -94.278*** | -51.470*** | -39.603*** | 54.675*** |
| (47.60%) | (42.28%) | (30.58%) | (23.53%) | (32.48%) | |
| Midfoot | -13.369*** | -18.719*** | -11.974*** | -17.324*** | 1.395*** |
| (11.73%) | (16.42%) | (10.63%) | (15.39%) | (1.24%) | |
| Hindfoot | -70.239*** | -106.609*** | 15.769*** | -20.601*** | 86.008*** |
| (30.52%) | (46.33%) | (10.94%) | (14.30%) | (59.69%) |
The p-values for pairwise comparisons were obtained from repeated-measures ANOVA with Bonferroni-adjusted post-hoc tests.
*p < 0.05, **p < 0.01, ***p < 0.001.
Table 3.
Peak impact force, time to peak force, and vertical impact loading rate during landing after jumping for different shoe midsole types.
| Midsole type | Peak impact force (N) | Time to peak force (ms) | VILR (N/ms) | |||
|---|---|---|---|---|---|---|
| ave | std | ave | std | ave | std | |
| A60 | 893.00 | 138.65 | 96.0 | 12.7 | 9.3 | 1.2 |
| A75 | 947.97 | 145.87 | 89.5 | 7.6 | 10.6 | 1.2 |
| N90 | 998.22 | 153.60 | 87.5 | 6.4 | 11.4 | 1.5 |
| PU | 928.08 | 184.52 | 76.5 | 13.5 | 12.3 | 2.3 |
Vertical impact loading rate
Figure 5A and B separately show the TPF and VILR of the plantar after landing from jumps while wearing different midsole types. RM-ANOVA results further showed that midsole type had a significant effect on TPF [F(2.033, 38.628) = 30.820, p < 0.001] and VILR [F(3, 57) = 11.013, p < 0.001] during jump landing. Post hoc comparisons showed that 3D-printed midsoles significantly prolonged the time to peak plantar impact force compared to the PU midsole. Among them, auxetic lattice midsoles A60 and A75 showed significantly lower VILRs than PU, indicating more effective cushioning of auxetic lattice midsoles. Table 3 shows the means of peak impact force (PIF), TPF, and VILR. Although there were slight differences in the mean PIF values under the four midsole conditions, ANOVA verified that PIF did not significantly affect TPF and VILR.
Fig. 5.

The vertical impact loading parameters between four different types of shoe midsoles. (A) Time to peak force. (B) Vertical impact loading rate.
During jump landing, the vertical ground reaction force typically exhibits a bimodal pattern: an initial passive impact peak occurring shortly after foot contact, followed by a larger active peak associated with body deceleration. The VILR values reported in Table 3 were calculated based on the force-time slope from initial contact to the passive impact peak, as this initial transient is most directly related to midsole cushioning performance.
Center of pressure mediolateral deviation
Figure 6 presents the total mediolateral CoP deviation during jump landing across the four midsole conditions. RM-ANOVA results indicated that midsole type had a significant effect on CoP mediolateral deviation during jump landing [F(3, 57) = 29.211, p < 0.001]. Post hoc comparisons showed that the total mediolateral CoP deviations of A75 and N90 among 3D-printed midsoles were significantly smaller than that of A60 and PU midsoles. Among 3D-printed auxetic midsoles, the CoP displacement of A75 was significantly smaller than that of A60.
Fig. 6.

Comparison of CoP mediolateral deviations during landing after jumping for different shoe midsole types.
Contact area
RM-ANOVA demonstrated significant effects of midsole design on plantar contact area across multiple regions (p < 0.001): hallux [F(1.462, 27.787) = 134.194, p < 0.001], toes 2–5 [F(1.263, 24.000) = 354.427, p < 0.001], MTH 1 [F(1.004, 19.084) = 12.774, p < 0.001], MTH 3–5 [F(1.099, 20.885) = 17.473, p < 0.001], midfoot [F(1.000, 19.000) = 1487.033, p < 0.001], and hindfoot [F(1.000, 19.000) = 1467.382, p < 0.001]. Table 4 compares the mean contact areas of different midsole types in each plantar region, calculates the mean differences, and provides p-values indicating the significance of pairwise comparisons of sample means. In terms of mean values, auxetic midsoles (A60 and A75) had larger contact areas in all plantar regions than non-auxetic midsoles (N90 and PU), especially in the toes, MTH 1, midfoot, and heel. The auxetic midsole A60 had significantly larger contact areas in almost all plantar regions than non-auxetic midsoles (N90 and PU), except for the MTH 2 region. During jump landing, the 60° internal angle of the auxetic lattice caused more midsole deformation and a significantly larger plantar contact area.
Table 4.
Mean difference in contact areas (cm2) between four different types of shoe midsoles.
| Variable | A60-N90 | A75-N90 | A60-PU | A75-PU | N90-PU |
|---|---|---|---|---|---|
| Hallux | 3.394*** | 2.850*** | 1.607*** | 1.064*** | -1.787*** |
| (67.22%) | (1.75%) | (23.51%) | (0.54%) | (0.91%) | |
| Toes 2–5 | 5.493*** | 4.310*** | 3.383*** | 2.200*** | -2.110*** |
| (33.25%) | (2.37%) | (18.16%) | (1.26%) | (1.21%) | |
| MTH 1 | 1.038*** | 0.857*** | 0.586*** | 0.404*** | -0.453*** |
| (8.52%) | (0.43%) | (4.63%) | (0.19%) | (0.22%) | |
| MTH 2 | 0.043 | 0.040 | 0.026 | 0.023 | -0.017 |
| (0.31%) | (0.02%) | (0.19%) | (0.01%) | (0.01%) | |
| MTH 3–5 | 1.265*** | 0.351*** | 0.892*** | -0.022 | -0.373*** |
| (9.08%) | (0.16%) | (6.24%) | (0.01%) | (0.22%) | |
| Midfoot | 9.559*** | 4.990*** | 10.889*** | 6.319*** | 1.330*** |
| (34.25%) | (4.38%) | (40.97%) | (5.61%) | (1.18%) | |
| Hindfoot | 9.852*** | 5.020*** | 10.649*** | 5.818*** | 0.797*** |
| (30.85%) | (2.18%) | (34.20%) | (4.04%) | (0.55%) |
The p-values for pairwise comparisons were obtained from repeated-measures ANOVA with Bonferroni-adjusted post-hoc tests.
*p < 0.05, **p < 0.01, ***p < 0.001.
Discussion
The present findings extend the current understanding of 3D-printed footwear biomechanics by providing experimental evidence specific to jump landing scenarios. Based on the experimental results, auxetic lattice-structured midsoles (A60 and A75) exhibited more substantial pressure reduction and cushioning performance during jump landing compared to non-auxetic (N90) or PU midsoles. According to Tables 2 and 4, statistical significance (p < 0.01) was observed for the comparison between PPPs and contact area across various plantar regions. A75 significantly reduced plantar pressure by 8.79% to 46.33% and increased plantar contact area by 0.43% to 4.38% compared to the non-auxetic lattice-structured midsole N90; A60 significantly reduced plantar pressure by 11.73% to 66.62% and increased contact area by 8.52% to 67.22%. Compared to the control PU sole, A75 significantly reduced plantar pressure by 4.90% to 42.47% and increased contact area by 0.54% to 5.61%; A60 significantly reduced plantar pressure by 5.14% to 72.13% and increased contact area by 4.63% to 40.97%. During jump landing, auxetic lattice-structured midsoles effectively reduced peak pressure in different plantar regions, and the closer fit between the foot and shoe resulted in a more uniform distribution of foot pressure. The results are consistent with existing studies on the pressure reduction characteristics of auxetic materials44. The reduction in unit load in each plantar region is related to the increase in plantar contact area45,46 because auxetic materials can conform to curved surfaces such as the human body by forming synclastic curvatures47. The reduction in plantar extreme pressure helps improve shoe comfort during jumping and reduce plantar tissue damage from impacts29. According to Fig. 5A, compared to non-auxetic lattice midsoles (N90 and PU), auxetic lattice midsoles (A60 and A75) significantly or non-significantly prolonged the time to PIF. The attenuation of VILRs corroborates established findings on the energy-dissipating characteristics of auxetic structures. These lattice-based midsoles collectively attenuated plantar pressure and enhanced impact cushioning during landing maneuvers, with the A60 configuration exhibiting optimal cushioning performance.
The present study distinguishes itself from recent parametric optimization investigations in several key respects. While Lu et al. and other computational studies have employed FE and ML methods to identify optimal lattice parameters for pressure reduction22,26, their findings are primarily derived from computational models and walking/static loading conditions. In contrast, the current work provides experimental biomechanical evidence specific to jump landing—a high-impact movement pattern that imposes substantially different mechanical demands on the midsole. Moreover, rather than searching for a global optimal parameter combination, the present study compares discrete lattice angles (60°, 75°, and 90°) to elucidate the structure-function relationship between auxetic geometry and biomechanical outcomes. The finding that different angles confer distinct advantages—with 60° optimizing forefoot cushioning and 75° enhancing stability—offers a complementary perspective to parametric optimization studies, providing experimentally validated design principles that can inform and ground future computational models.
However, experimental results showed that A60 exhibited the largest mediolateral CoP deviation among all midsole types. This observation is consistent with the finding of Leong et al.40 that softer midsoles are associated with larger CoP deviations. Notably, the CoP trajectory during jump landing is influenced by whole-body postural control. The present data therefore indicate an association between midsole type and CoP deviation rather than a direct causal relationship. Accordingly, CoP deviation is best interpreted as a biomechanical indicator that differed significantly across midsole conditions. The 75° internal angle lattice structure was relatively stable, and its auxetic structure provided conformability, resulting in the minor CoP deviation for A75 among all midsole types. CoP deviation is a widely used stability-related biomechanical indicator32, but it is not equivalent to a comprehensive measure of dynamic stability. Within this framework, the significantly smaller CoP deviation observed with the A75 midsole suggests favorable stability characteristics relative to the other conditions. A more complete assessment would require whole-body kinematic and kinetic measurements, as well as analysis of the relationship between the CoP and the center of mass. Nonetheless, based on the plantar-pressure-derived CoP data, the A75 midsole demonstrated the most favorable stability-related profile among the four conditions.
The pressure distribution patterns observed in this study offer preliminary insights for footwear design in sports involving frequent jump landing maneuvers. The superior forefoot pressure reduction of A60, for instance, aligns with the suggestion by Lam et al.48 that softer forefoot materials may help reduce high plantar loads. Similarly, the enhanced mediolateral stability of A75 may be relevant to activities demanding postural control49,50. However, direct translation of these findings into sport-specific recommendations—particularly for competitive athletes, female populations, or individuals with different foot sizes—requires confirmatory studies employing sport-specific protocols and diverse participant cohorts. Footwear for sports emphasizing balance and stability is recommended to adopt the A75 lattice structure design. Although A75 has slightly lower cushioning than A60, it exhibits more substantial pressure reduction in the midfoot and heel regions. In particular, compared to other midsoles, including A60, A75 has a significantly smaller CoP offset and more stable jump landing, making it suitable for sports requiring dynamic postural stability, like single-leg jump landings.
This research examines midsole structural impacts on jump landing biomechanics independent of shoe categorization. The physical characteristics of auxetic lattice designs demonstrated herein provide preliminary mechanical references for sports footwear innovation. These findings highlight the potential for angle-specific lattice designs to address distinct biomechanical demands—forefoot cushioning for A60 and mediolateral stability for A75. Further studies are needed to translate these mechanical principles into injury mitigation outcomes in real-world athletic settings.
Nevertheless, methodological considerations should be acknowledged when interpreting these findings. The recruitment of a homogeneous cohort of healthy young males (aged 19–23, non-athletes) was intentional, serving to minimize confounding influences from sex-related anatomical differences, age-dependent neuromuscular adaptations, and training-induced biomechanical variability. This design prioritizes internal validity, ensuring that the observed effects are robustly attributable to the midsole lattice geometry rather than to population heterogeneity. Concurrently, this demographic specificity circumscribes direct extrapolation to other populations (e.g., females, older adults, or elite athletes). Although no a priori sample size calculation was performed, post-hoc power analyses based on the observed large effect sizes indicated that the current sample of 20 participants provided > 0.8 statistical power to detect the main effects under the repeated-measures framework. Future research incorporating diverse populations and pre-registered sample size estimations will further strengthen external validity. Additionally, while comfort perception was not directly measured, the biomechanical parameters assessed—peak pressure, contact area, loading rate, and CoP deviation—constitute well-established objective proxies for footwear comfort and stability27,33,40.
A further methodological consideration concerns the measurement of VILR. The Pedar-X system employed in this study operates at a sampling rate of 50 Hz. While this rate is adequate for plantar pressure distribution and contact area analysis, it is lower than the sampling frequencies typically recommended for accurate capture of impact transients. Recent evidence indicates that a minimum of 62 Hz is required to achieve 90% accuracy of impact force during bilateral landing, and 192 Hz for average loading rate. Consequently, the absolute VILR values reported herein should be interpreted as relative estimates rather than exact quantitative measures. Crucially, however, because all four midsole conditions were subject to the identical measurement limitations, the comparative ranking and statistical significance of the differences among conditions remain robust. Future studies employing higher sampling rate force platforms (≥ 1000 Hz) are warranted to validate the absolute VILR values observed in the present work.
The FEA serves as a supplementary mechanical interpretation, not a quantitative validation of the experiments. The model incorporated simplifications—a generic foot geometry, homogeneous material properties, idealized contacts, rigid COM-ankle connection, and y-direction loading—that limit the accuracy of absolute pressure predictions. Nevertheless, the FEA reproduced the experimental ranking (A60 < A75 < N90), supporting the trend that auxetic structures reduce peak pressures. This ranking consistency, rather than the absolute values, is the primary contribution of the simulation.
The auxetic effect of the A60 and A75 structures was inferred from their geometric configurations rather than directly verified through mechanical testing. Notably, the observed increases in contact area and reductions in peak pressure are consistent with the expected deformation behavior of auxetic materials27,44. Direct measurements of local compressive stiffness and negative Poisson‘s ratio would provide more definitive evidence. Future studies should incorporate systematic mechanical characterization—including stress-strain curves and lateral strain measurement—to establish a direct link between geometric parameters, mechanical properties, and biomechanical outcomes.
Conclusions
This study confirms that auxetic lattice-structured midsoles effectively enhance cushioning performance during jump landing. Their negative Poisson ratio and deformation adaptability significantly increase foot-shoe contact area and disperse impact loads. Furthermore, the study reveals the regulatory mechanism of lattice angles on function—smaller angles (60°) enhance forefoot cushioning, while larger angles (75°) balance cushioning and stability. In midsole design, a zonal application strategy is proposed based on sports scenario requirements. Within the population studied, the mechanical advantages identified—forefoot pressure dissipation for the 60° lattice and enhanced stability for the 75° lattice—provide a mechanical basis for zoned midsole design concepts. These principles offer preliminary design guidance for athletic footwear, with the understanding that translation to specific sports (e.g., basketball, volleyball, dance) or other populations requires confirmatory studies. These findings contribute initial experimental evidence to the growing body of research on auxetic structures in footwear applications. These conclusions should be interpreted within a deliberately controlled experimental framework. The homogeneous sample provides a robust mechanical benchmark, yet extension to broader populations remains a logical next step. The comparative ranking of VILR data is reliable, though higher-fidelity instrumentation would refine absolute values. The FEA offers supplementary trend support, and subsequent mechanical testing could further validate the auxetic interpretation. Future work integrating diverse cohorts, refined measurements, and experimental-computational synergy will be essential to translate these findings into broader footwear applications.
Supplementary Information
Below is the link to the electronic supplementary material.
Acknowledgements
The authors extend their sincere gratitude to Prof. Huang of Guangzhou Sport University for supplying the plantar pressure measurement system and offering technical guidance on its operation. Appreciation is also extended to the Experimental Center of the School of Art and Design and the Instrumental Analysis Center at Guangdong University of Technology for their valuable support.
Author contributions
Jifa Zhang: Conceptualization, Methodology, Formal analysis, Investigation, Writing – Original Draft. Runhua Huang: Software, Validation, Data Curation, Visualization. Yibing Chen: Supervision, Funding acquisition, Project administration, Resources, Writing – Review & Editing. Yangbo He: Formal analysis, Software, Visualization. Qi Wu: Investigation, Resources. Yadie Yang: Methodology, Validation, Writing – Review & Editing.
Funding
This research is supported by funds from Guangdong Office of Philosophy and Social Science (GD22CYS01).
Data availability
The data that support the findings of this study are available from Guangzhou Sport University but restrictions apply to the availability of these data, which were used under license for the current study, and so are not publicly available. Data are however available from the authors upon reasonable request and with permission of Guangzhou Sport University.
Declarations
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Bates, N. A., Ford, K. R., Myer, G. D. & Hewett, T. E. Timing differences in the generation of ground reaction forces between the initial and secondary landing phases of the drop vertical jump. Clin. Biomech28(7), 796–799 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Ali, N., Robertson, D. G. E. & Rouhi, G. Sagittal Plane Body Kinematics and Kinetics During Single-Leg Landing from Increasing Vertical Heights and Horizontal Distances: Implications for Risk of Non-Contact Acl Injury. Knee21(1), 38–46 (2014). [DOI] [PubMed] [Google Scholar]
- 3.Morelli, V., Braxton, T. M. & Meniscal Plica, Patellar, and Patellofemoral Injuries of the Knee: Updates, Controversies and Advancements. Prim. Care: Clin. Office Pract.40(2), 357–382 (2013). [DOI] [PubMed] [Google Scholar]
- 4.Salem, G. J., Salinas, R. & Harding, F. V. Bilateral Kinematic and Kinetic Analysis of the Squat Exercise after Anterior Cruciate Ligament Reconstruction. Archives Phys. Med. rehabilitation. 84(8), 1211–1216 (2003). [DOI] [PubMed] [Google Scholar]
- 5.Sun, X., Lam, W. K., Zhang, X., Wang, J. & Fu, W. Systematic Review of the Role of Footwear Constructions in Running Biomechanics: Implications for Running-Related Injury and Performance. J. sports Sci. Med.19(1), 20 (2020). [PMC free article] [PubMed] [Google Scholar]
- 6.Yu, H. B. et al. Effects of Shoe Midsole Hardness on Lower Extremity Biomechanics During Jump Rope in Healthy Males. In Healthcare 1394 (MDPI, 2021). [DOI] [PMC free article] [PubMed]
- 7.Lam, W. K., Liu, H., Wu, G. Q., Liu, Z. L. & Sun, W. Effect of Shoe wearing time and midsole hardness on ground reaction forces, ankle stability and perceived comfort in basketball landing. 37(20), 2347–2355 (2019). [DOI] [PubMed]
- 8.Nin, D. Z., Lam, W. K. & Kong, P. W. Effect of Body Mass and Midsole Hardness on Kinetic and Perceptual Variables During Basketball Landing Manoeuvres. J. Sports Sci.34(8), 756–765 (2016). [DOI] [PubMed] [Google Scholar]
- 9.Zhang, R., Zhao, L., Kong, Q., Yu, G. & Yu, H. Multi-Objective Design and Optimization of High Cushioning Bionic Shoe Midsole under Limited Thickness of Forefoot. Compos. Struct.324, 117560 (2023). [Google Scholar]
- 10.De Britto, M. A. et al. Effects of a Rebound Shoe to Reduce Impact Forces in Jump-Landing Tasks. J. Bodyw. Mov. Ther.26, 77–83 (2021). [DOI] [PubMed] [Google Scholar]
- 11.Moroney, C., Alderson, A., Allen, T., Sanami, M. & Venkatraman, P. The Application of Auxetic Material for Protective Sports Apparel. In Proceedings: 2018 251 (MDPI, 2018).
- 12.Dong, Z. et al. Experimental and Numerical Studies on the Compressive Mechanical Properties of the Metallic Auxetic Reentrant Honeycomb. Mater. Des.182, 108036 (2019). [Google Scholar]
- 13.Prawoto, Y. Seeing Auxetic Materials from the Mechanics Point of View: A Structural Review on the Negative Poisson’s Ratio. Comput. Mater. Sci.58, 140–153 (2012). [Google Scholar]
- 14.Jasińska, D., Janus-Michalska, M. & Smardzewski, J. A Study on the Design of Auxetic Structure of Seat Skeleton. Mech. Control. 31(2), 72–76 (2012). [Google Scholar]
- 15.Yang, C., Vora, H. D. & Chang, Y. Behavior of Auxetic Structures under Compression and Impact Forces. Smart Mater. Struct.27(2), 025012 (2018). [Google Scholar]
- 16.Allen, T. et al. Low-Kinetic Energy Impact Response of Auxetic and Conventional Open‐Cell Polyurethane Foams. Phys. status solidi. 252(7), 1631–1639 (2015). [Google Scholar]
- 17.Michalski, J. & Strek, T. Fatigue Life of Auxetic Re-Entrant Honeycomb Structure. In Advances in Manufacturing II: Volume 4-Mechanical Engineering: 2019 50–60 (Springer, 2019).
- 18.Han, D. et al. Lightweight Auxetic Metamaterials: Design and Characteristic Study. Compos. Struct.293, 115706 (2022). [Google Scholar]
- 19.Zhang, Y. et al. Design and Analysis of an Auxetic Metamaterial with Tuneable Stiffness. Compos. Struct.281, 114997 (2022). [Google Scholar]
- 20.Lu, Z. et al. J.F.S. Will This Be the Next Step? A Systematic review of 3d printing in footwear biomechanics. 17(2), 127–142. (2025).
- 21.Novak, J. I. & Novak, A. R. Technology is additive manufacturing improving performance in sports? A systematic review. Journal of Sports Engineering235(3), 163–175 (2021).
- 22.Lu, Z. et al. Parametric cushioning lattice insole based on finite element method and machine learning: A preliminary computational analysis. J. Bomech.184, 112674 (2025). [DOI] [PubMed]
- 23.Baranowski, P., Kapusta, A., Płatek, P. & Sarzyński, M. J. B. Influence of 3d-Printed Cellular Shoe Soles on Plantar Pressure During Running– Experimental and Numerical Studies. Eng. B. 44(4), 858–873 (2024). [Google Scholar]
- 24.Sun, Y. et al. Design 3d printed sports shoe midsoles: enhancing comfort and performance through finite element analysis of negative Poisson’s Ratio structures. Mater. Des.245, 113292 (2024).
- 25.Lu, Z. et al. Computationally tuned dual-layer lattice pads adapted to gait-induced pressure distribution. Npj Adv. Manuf. 2 In. (2025).
- 26.Ford, R. R., Misra, M., Mohanty, A. K. & Brandon, S. C. Effect of Simulated Mass-Tunable Auxetic Midsole on Vertical Ground Reaction Force. J. Biomech. Eng.144(11), 111007 (2022). [DOI] [PubMed] [Google Scholar]
- 27.Honarvar, S., Nourani, A., Yarandi, A. & Ghehi, F. F. Three-dimensional finite element modeling of the shoe sole to investigate the impact of various geometries on foot heel stresses and energy absorption. In 2022 29th National and 7th International Iranian Conference on Biomedical Engineering (ICBME) 340–345 (IEEE, 2022).
- 28.Nourani, A., Daei, M. D. & Honarmand, M. Comparison of energy absorption in conventional and auxetic shoes: Gait analysis and finite element modeling. J. Des. Against Fatigue. 1(2). 10.62676/jz62m929 (2023). [DOI]
- 29.Zhang, J. et al. Efficacy of Auxetic Lattice Structured Shoe Sole in Advancing Footwear Comfort—from the Perspective of Plantar Pressure and Contact Area. Front. public. health. 12, 1412518 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Leung, M. S., Yick, K., Sun, Y. & Chow, L. Ng S.-p. 3d Printed Auxetic Heel Pads for Patients with Diabetic Mellitus. Computers Biology Med.146, 105582 (2022). [DOI] [PubMed] [Google Scholar]
- 31.Dehaghani, M. R., Nourani, A. & Arjmand, N. Effects of Auxetic Shoe on Lumbar Spine Kinematics and Kinetics During Gait and Drop Vertical Jump by a Combined in Vivo and Modeling Investigation. Sci. Rep.12(1), 18326 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Fort, A., Romero, D., Bagur, C. & Guerra, M. Effects of Whole-Body Vibration Training on Explosive Strength and Postural Control in Young Female Athletes. J. Strength. Conditioning Res.26(4), 926–936 (2012). [DOI] [PubMed] [Google Scholar]
- 33.Zhang, X. et al. Shoe Cushioning Effects on Foot Loading and Comfort Perception During Typical Basketball Maneuvers. Appl. Sci.9(18), 3893 (2019). [Google Scholar]
- 34.Ruder, M., Atimetin, P., Futrell, E. & Davis, I. Effect of Highly Cushioned Shoes on Ground Reaction Forces During Running. Med. Sci. Sports Exerc.47(5S), 293–294 (2015). [Google Scholar]
- 35.Evans, K. E., Nkansah, M. & Hutchinson, I. Auxetic Foams: Modelling Negative Poisson’s Ratios. Acta Metall. Mater.42(4), 1289–1294 (1994). [Google Scholar]
- 36.Krauss, P. T. G. Improving Vertical Jump Performance with Biomechanical Feedback (California State University, 2017).
- 37.Orendurff, M. S., Rohr, E. S., Segal, A. D., Medley, J. W. & Green, J. R. III Kadel N.J. Regional Foot Pressure During Running, Cutting, Jumping, and Landing. Am. J. Sports Med.36(3), 566–571 (2008). [DOI] [PubMed] [Google Scholar]
- 38.Alirezaei Noghondar, F. & Bressel, E. Effect of Shoe Insole Density on Impact Characteristics and Performance During a Jump-Landing Task. Footwear Sci.9(2), 95–101 (2017). [Google Scholar]
- 39.Van Alsenoy, K., Ryu, J. H. & Girard, O. The Effect of Eva and Tpu Custom Foot Orthoses on Running Economy, Running Mechanics, and Comfort. Front. sports Act. living. 1, 34 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Leong, H. F., Lam, W. K., Ng, W. X. & Kong, P. W. Center of Pressure and Perceived Stability in Basketball Shoes with Soft and Hard Midsoles. J. Appl. Biomech.34(4), 284–290 (2018). [DOI] [PubMed] [Google Scholar]
- 41.Erdman, W. Center of mass of the human body helps in analysis of balance and movement. MOJ Appl. Bionics Biomech.2(2) (2018).
- 42.Shahzad, M., Kamran, A., Siddiqui, M. Z. & Farhan, M. Mechanical Characterization and Fe Modelling of a Hyperelastic Material. Mater. Res.18(5), 918–924 (2015). [Google Scholar]
- 43.Zhang, J. et al. Pressure-Reducing Design of 3d-Printed Diabetic Shoe Midsole Utilizing Auxetic Lattice Structure. Appl. Sci.14(12), 5291 (2024). [Google Scholar]
- 44.Critchley, R. et al. Blast Mitigation Using Polymeric 3d Printed Auxetic Re-Entrant Honeycomb Structures: A Preliminary Study. Int. J. Protective Struct.13(3), 469–486 (2022). [Google Scholar]
- 45.Tawk, C., Mutlu, R. & Alici, G. A 3d Printed Modular Soft Gripper Integrated with Metamaterials for Conformal Grasping. Front. Rob. AI. 8, 799230 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Fernández-Seguín, L. M. et al. Comparison of Plantar Pressures and Contact Area between Normal and Cavus Foot. Gait posture. 39(2), 789–792 (2014). [DOI] [PubMed] [Google Scholar]
- 47.Wallbanks, M., Khan, M. F., Bodaghi, M., Triantaphyllou, A. & Serjouei, A. On the Design Workflow of Auxetic Metamaterials for Structural Applications. Smart Mater. Struct.31(2), 023002 (2021). [Google Scholar]
- 48.Lam, W. K., Ng, W. X. & Kong, P. W. Influence of Shoe Midsole Hardness on Plantar Pressure Distribution in Four Basketball-Related Movements. Res. Sports Med.25(1), 37–47 (2017). [DOI] [PubMed] [Google Scholar]
- 49.Wyon, M. A., Cloak, R., Lucas, J. & Clarke, F. Effect of Midsole Thickness of Dance Shoes on Dynamic Postural Stability. Med. Probl. Perform. Artist.28(4), 195–198 (2013). [PubMed] [Google Scholar]
- 50.Bowser, B. J. et al. Effect of Footwear on Dynamic Stability During Single-Leg Jump Landings. Int. J. Sports Med.38(06), 481–486 (2017). [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from Guangzhou Sport University but restrictions apply to the availability of these data, which were used under license for the current study, and so are not publicly available. Data are however available from the authors upon reasonable request and with permission of Guangzhou Sport University.